Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Preparation and physical properties of antiperovskite-type compounds CdNCo{sub 3-z}Ni{sub z} (0{<=}z{<=}3)

A series of CdNCo{sub 3-z}Ni{sub z} (0{<=}z{<=}3) samples were prepared from CdO and metal powders under NH{sub 3} atmosphere at 743 K. The structural and physical properties were investigated by means of X-ray powder diffraction, temperature dependent resistivity and magnetic measurements. X-ray powder diffraction results show that CdNCo{sub 3} is a new ternary nitride with antiperovskite structure, and it can form a complete solid solution series with CdNNi{sub 3}. Both CdNCo{sub 3} and CdNNi{sub 3} samples show metallic temperature dependent resistivity and exhibit a Fermi liquid behavior below 50 K. All samples are ferromagnetic, and their coercivity and remanence decrease as the Ni content increases. The temperature dependence of the magnetization of the CdNCo{sub 3-z}Ni{sub z} samples can be well fitted to the combination of a Bloch term and a Curie-Weiss term. The CdNCo{sub 3} sample is ferromagnet with coercivity of 240 Oe at room-temperature. In contrast to the paramagnetism previously reported, our CdNNi{sub 3} sample exhibits very soft and weak ferromagnetism. - Graphical Abstract: CdNCo{sub 3} is a new ternary nitride with antiperovskite structure, and it can form a complete solid solution series with CdNNi{sub 3}. Highlights: > CdNCo{sub 3-z}Ni{sub z} (0{<=}z{<=}3) samples were synthesized by solid-gas reactions. > CdNCo{sub 3} is a new ternary antiperovskite nitride, and it can form a complete solid solution series with CdNNi{sub 3}. > Both CdNCo{sub 3} and CdNNi{sub 3} samples show metallic behavior and exhibit a Fermi liquid behavior below 50 K. > Magnetic measurements show that CdNCo{sub 3} and CdNNi{sub 3} exhibit ferromagnetic and weak ferromagnetic behavior, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfluidic liquid sheets as large-area targets for high repetition XFELs

The high intensity of X-ray free electron lasers (XFELs) can damage solution-phase samples on every scale, ranging from the molecular or electronic structure of a sample to the macroscopic structure of a liquid microjet. By using a large surface area liquid sheet microjet as a sample target instead of a standard cylindrical microjet, the incident X-ray spot size can be increased such that the incident intensity falls below the damage threshold. This capability is becoming particularly important for high repetition rate XFELs, where destroying a target with each pulse would require prohibitively large volumes of sample. We present here a study of microfluidic liquid sheet dimensions as a function of liquid flow rate. Sheet lengths, widths and thickness gradients are shown for three styles of nozzles fabricated from isotropically etched glass. In-vacuum operation and sample recirculation using these nozzles is demonstrated. The effects of intense XFEL pulses on the structure of a liquid sheet are also briefly examined.

47 OTHER INSTRUMENTATION↗

Plastic waste to liquid oil through catalytic pyrolysis using natural and synthetic zeolite catalysts

Highlights: • Liquid fuel was produced from plastic waste through catalytic pyrolysis. • Pyrolysis of polystyrene plastic produced highest liquid oil yield of 54% using natural zeolite. • Pyrolysis liquid oil mainly consisted of aromatic hydrocarbons with a few aliphatic compounds. • Primary compounds in liquid oil were styrene, ethylbenzene, benzene, azulene, and naphthalene. • Liquid oil had high heating values (HHV) of 40.2–45 MJ/kg. - Abstract: This study aims to examine the catalytic pyrolysis of various plastic wastes in the presence of natural and synthetic zeolite catalysts. A small pilot scale reactor was commissioned to carry out the catalytic pyrolysis of polystyrene (PS), polypropylene (PP), polyethylene (PE) and their mixtures in different ratios at 450 °C and 75 min. PS plastic waste resulted in the highest liquid oil yield of 54% using natural zeolite and 50% using synthetic zeolite catalysts. Mixing of PS with other plastic wastes lowered the liquid oil yield whereas all mixtures of PP and PE resulted in higher liquid oil yield than the individual plastic feedstocks using both catalysts. The GC–MS analysis revealed that the pyrolysis liquid oils from all samples mainly consisted of aromatic hydrocarbons with a few aliphatic hydrocarbon compounds. The types and amounts of different compounds present in liquid oils vary with some common compounds such as styrene, ethylbenzene, benzene, azulene, naphthalene, and toluene. The FT-IR data also confirmed that liquid oil contained mostly aromatic compounds with some alkanes, alkenes and small amounts of phenol group. The produced liquid oils have high heating values (HHV) of 40.2–45 MJ/kg, which are similar to conventional diesel. The liquid oil has potential to be used as an alternative source of energy or fuel production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FLAMES─Fast, Low-Storage, Accurate, and Memory-Efficient Adaptive Sampling─Approach to Resolve Spatially Dependent Dynamics of Molecular Liquids

Many critical phenomena in soft matter occur at large length scales, necessitating the resolution of their structure and dynamics at low wavenumbers. However, resolving wavenumber-dependent dynamics computationally via molecular dynamics simulations presents significant challenges, as these phenomena span several orders of magnitude in both time and length scales, resulting in high computational costs and memory demands. Here, this work highlights the computational and memory challenges associated with analyzing molecular trajectories in reciprocal space and demonstrates a method to address them. We introduce FLAMESFast, Low-storage, Accurate, and Memory-Efficient adaptive Sampling, which is a direct method for calculation of structure factors, allowing us to select only the required number of wavevectors for binning. We also use wavenumber-dependent time steps to extract dynamics. Our FLAMES approach effectively mitigates computational and memory/storage bottlenecks. We demonstrate the method using simulations of a model system, liquid octane, at various temperatures. Comparisons with experimental data and real space computation show that the FLAMES technique achieves high accuracy in resolving temperature- and spatially dependent dynamics while being significantly more computationally efficient and requiring less memory and storage than methods based on a uniform wavevector grid and fixed temporal spacing.

Chen, Guang [Argonne National Laboratory (ANL), Ar↗

Serum Proteome Signature of Radiation Response: Upregulation of Inflammation-Related Factors and Downregulation of Apolipoproteins and Coagulation Factors in Cancer Patients Treated With Radiation Therapy—A Pilot Study

Purpose: Ionizing radiation affects the proteome of irradiated cells and tissue, yet data concerning changes induced during radiation therapy (RT) in human blood are fragmentary and inconclusive. We aimed to identify features of serum proteome and associated processes involved in response to partial body irradiation during cancer treatment. Methods and Materials: Twenty patients with head and neck squamous cell cancer (HNSCC) and 20 patients with prostate cancer received definitive intensity modulated RT. Blood samples were collected before RT, just after RT, and 1 month after the end of RT. Complete serum proteome was analyzed in individual samples, using a shotgun liquid chromatography-tandem mass spectrometry approach which allowed identification of approximately 450 proteins. Approximately 100 unique proteins were quantified in all samples after exclusion of immunoglobulins, and statistical significance of differences among consecutive samples was assessed. Processes associated with quantified proteins and their functional interactions were predicted using gene ontology tools. Results: RT-induced changes were marked in the HNSCC patient group: 22 upregulated and 33 downregulated proteins were detected in post-RT sera. Most of the changes reversed during follow-up, yet levels of some proteins remained affected 1 month after the end of RT. RT-upregulated proteins were associated with acute phase, inflammatory response, and complement activation. RT-downregulated proteins were associated with transport and metabolism of lipids (plasma apolipoproteins) and blood coagulation. RT-induced changes were much weaker in prostate cancer patients, which corresponded to differences in acute radiation toxicity observed in both groups. Nevertheless, general patterns of RT-induced sera proteome changes were similar in both of the groups of cancer patients. Conclusions: In this pilot study, we proposed to identify a molecular signature of radiation response, based on specific features of serum proteome. The signature included upregulation of factors involved in acute or inflammatory response but also downregulation of plasma apolipoproteins and factors involved in blood coagulation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NMR relaxation of molecules confined inside the cement paste pores under partially saturated conditions

Nuclear Magnetic Resonance (NMR) relaxation studies of liquids confined inside cement samples mostly refer to water molecules and saturated pores. Here we extend these studies to the ethanol and cyclohexane molecules partially saturating a white cement paste. The two filling liquids were selected as representatives of polar and nonpolar molecules which should experience different interactions with the surface containing OH groups. The results on these two molecules are compared with those obtained on water filled sample. The transverse relaxation measurements, performed at different saturation degrees, clearly revealed three pore reservoirs in cement paste: intra-C-S-H sheet pores, inter-C-S-H gel pores and capillary pores. A two phase exchange model, describing the effective relaxation rate under partially saturated conditions, is also considered. The model allows finding of a relationship between the relaxation time distribution, the filling degree of the pores and the liquid morphology inside these pores.

36 MATERIALS SCIENCE↗

Dismantling of the PETRA glove box: tritium contamination and inventory assessment

The PETRA facility is the first installation in which experiments with tritium were carried out at the Tritium Laboratory Karlsruhe. After completion of two main experimental programs, the decommissioning of PETRA was initiated with the aim to reuse the glove box and its main still valuable components. A decommissioning plan was engaged to: -) identify the source of tritium release in the glove box, -) clarify the status of the main components, -) assess residual tritium inventories, and -) de-tritiate the components to be disposed of as waste. Several analytical techniques - calorimetry on small solid samples, wipe test followed by liquid scintillation counting for surface contamination assessment, gas chromatography on gaseous samples - were deployed and cross-checked to assess the remaining tritium inventories and initiate the decommissioning process. The methodology and the main outcomes of the numerous different tritium measurements are presented and discussed. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Modification of the Surface of Nickel by the Femtosecond Laser Pulses

Experimental results of the formation of a periodic submicron structure on the surface of polycrystalline nickel (Ni) under laser irradiation in air and in a liquid medium (distilled water) are presented. The geometry of the formed surface structures is determined by electron-microscopy methods. When irradiated in air, the structure is formed above the base surface of the sample, and when irradiated in the liquid, it is formed below the base surface. The dimensions of the pure Ni nanoparticles formed during laser ablation of the nickel sample in the liquid were determined.

36 MATERIALS SCIENCE↗

The solidification of Al–Pd–Mn studied by high-energy X-ray diffraction from electrostatically levitated samples

Here, we report on the results of a high-energy x-ray diffraction study of Al–Pd–Mn to investigate the solidification products obtained during free-cooling using an electrostatic levitation furnace. The primary solidification product from the melt is i-Al–Pd–Mn which coexists with a significant remaining liquid component. As the sample cools further, we find that the solidification pathway is consistent with the liquidus projection and pseudo-binary cut through the ternary phase diagram reported previously. At ambient temperature we have identified the major phase to be the ξ'-phase orthorhombic approximant, along with minor phases identified as Al and, most likely, the R-phase orthorhombic approximant. We have also observed a distinct prepeak in the liquid at high temperature, signifying the presence of extended atomic order. Interestingly, this prepeak was not observed in previous neutron diffraction measurements on the Al–Pd–Mn system. No undercooling was observed preceding the solidification of the i-Al–Pd–Mn phase from the melt which may signal the close similarity of the short-range order in the solid and liquid. However, this can not be clearly determined because of the potential for heterogenous nucleation associated with the presence of an Al2O3 impurity at the surface of the sample.

36 MATERIALS SCIENCE↗

Report for the Corrosion Testing of Solutions to Aid in the Removal of 241-AP-106 Waste: Dilution Series Testing

Corrosion analyses were conducted at the 222-S Laboratory in support of proposed liquid waste removal from tank 241-AP-106 (AP-106) in preparation for its use in direct feed low activity waste treatment. The work reported here builds upon previous corrosion testing performed at the 222-S Laboratory that used a high-density caustic and an AP-106 tank waste sample. In this current study, a second liquid grab sample from AP-106 was diluted, 50:50 vol%, with raw water, and this dilution was repeated for a total of 5 dilutions steps. Following each dilution step, the resulting solution was tested for pitting corrosion using linear polarization resistance followed by cyclic potentiodynamic polarization.

241-AP-106↗

Digital Autoradiography as a novel complementary technique for the investigation of radioactive contamination in nuclear facilities under dismantlement

The detection (location and quantification) of nuclear facilities to be dismantled possible contamination with low-range particles emitters ({sup 3}H, other low-energy β emitters, a emitters) remains a tedious and expensive task. Indeed, usual remote counters show a too low sensitivity to these non-penetrating radiations, while conventional wipe tests are irrelevant for fixed radioactivity evaluation. The only method to accurately measure activity levels consists in sampling and running advanced laboratory analyses (spectroscopy, liquid scintillation counting, pyrolysis...). Such measurements generally induce sample preparation, waste production (destructive analyses, solvents), nuclear material transportation, long durations, and significant labor mobilization. Therefore, the search for the limitation of their number and cost easily conflicts with the necessity to perform a dense screening for sampling (to maximize the representativeness of the samples), in installations of thousands of square meters (floors, wells, ceilings), plus furniture, pipes, and other wastes. To overcome this contradiction, Digital Autoradiography (D. A.) was re-routed from bio molecular research to radiological mapping of nuclear installations under dismantling and to waste and sample analysis. After in-situ exposure to the possibly-contaminated areas to investigate, commercial reusable radiosensitive phosphor screens (of a few 100 cm{sup 2}) were scanned in the proper laboratory device and sharp quantitative images of the radioactivity could be obtained. The implementation of geostatistical tools in the data processing software enabled the exhaustive characterization of concrete floors at a rate of 2 weeks / 100 m{sup 2}, at lowest costs. Various samples such as drilled cores, or tank and wood pieces, were also successfully evaluated with this method, for decisive results. Thanks to the accurate location of potential contamination spots, this approach ensures relevant and representative sampling for further laboratory analyses and should be inserted in the range of common tools used in dismantling. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the evolution of liquid and solid microjets from grooved Sn and Cu samples using radiography

Experiments were performed on grooved Sn and Cu samples to study the temporal evolution of microjets. Jets were generated by the impact of gun-launched flyer plates against the back of grooved targets made from either Cu or Sn (groove depth of ~250 μm). The Hugoniot states in the various Sn targets encompassed conditions where solid phases are maintained throughout (7 and 16 GPa) and also conditions where melting occurs upon the release of compression (25 and 34 GPa); the transition occurs near a Hugoniot pressure of 23 GPa. Cu targets at 27 and 56 GPa provide comparisons in which the jets move at similar speeds but remain solid. In all cases, the spatial distribution of mass within the microjets was measured using high-speed synchrotron radiography. The result is a time history of the jet thickness profile from which quantities like total jet mass and jet velocity can be derived. In both the solid and liquid states, we generally observe that an increase in the shock strength leads to an increase in jet mass. However, this trend breaks down for Hugoniot states near the transition from continuously solid to melted-on-release. This is evidenced by the observation that there was no difference in the rate of mass flow in Sn jets at 16 and 25 GPa, while similar pressure jumps on either side of this range caused substantial changes in the jet mass. This contrasts with the behavior of smaller polishing defects that were present on the same samples (~1 μm deep). From these, no ejecta mass was detected below the melt boundary, but obvious microjets were generated once melting occurred. This indicates that crossing the bulk melt-on-release threshold can alternately promote or inhibit the flow of mass into microjets based on the amplitude of the initial perturbation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mercury speciation using microcolumns with a direct mercury analyzer (DMA). Development of analytical method for the Savannah River Site liquid system

Mercury in the Savannah River Site (SRS) Liquid Waste System (LWS) exists in various forms, including: a) ionic inorganic mercury, organomercury (e.g., methyl Hg), and other less abundant species dissolved in LWS fluids, b) mercury solids such as oxides, hydroxides, amalgams, sulfides, and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury in tank headspace gas and in evaporators. Strategic and proactive management of the estimated 60,000 Kg mercury in the LWS requires deployment of efficient and effective paradigms for sampling and analysis of the total quantity of mercury in the various physical-chemical forms. Scoping tests of selective gas-phase sorbents for mercury speciation were performed to support LWS objectives. This research specifically focused on developing and testing streamlined methods to obtain high-quality analytical results for gaseous mercury species. The proposed methods are straightforward, using small columns (microcolumns) filled with materials that selectively sorb one or more target forms of mercury. Simple differentiation of mercury species and quantification is then achieved using an efficient thermal-desorption-based total mercury analyzer as the final step. Benefits associated with transitioning from multistep procedures such as EPA Methods 245.1, 1630 and 1631to streamlined microcolumn approaches include reduced analysis time, labor, and waste generation. Such transitioning would maximize the value of the current deployment of direct mercury analysis (EPA Method 7473) at SRS. This work has two target end uses: 1) simplifying the analysis steps and reducing costs for liquid samples (e.g., developing a total organic mercury (TOM) method), and 2) providing options for high-quality onsite analysis and rapid turnaround for gas samples in support of SRS LWS industrial hygiene (IH) objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enabling liquid vapor analysis using synchrotron VUV single photon ionization mass spectrometry with a microfluidic interface

Vacuum ultraviolet (VUV) single photon ionization mass spectrometry (SPI-MS) is a vacuum-based technique typically used for analysis of gas phase and solid samples, but not for liquids, due to the challenge in proposing volatile liquids in vacuum. In this work we introduce the first demonstration of in situ liquid analysis by integrating the System for Analysis at the Liquid Vacuum Interface (SALVI) microfluidic reactor into VUV SPI-MS. Four representative volatile organic compound (VOC) solutions were used to illustrate feasibility of liquid analysis. Our results reflect accurate mass identification of the VOC molecules and reliable determination of appearance energy (AE) that is consistent with ionization energy (IE) for gaseous species in literature as reported. This work validates that the vacuum-compatible SALVI microfluidic interface can be utilized at the synchrotron beamline and enable in situ research of gas-phase molecules evaporating off the surface of a liquid, which holds importance in the study of condensed matter chemistry.

47 OTHER INSTRUMENTATION↗

Electrical conductivity of methane hydrate with pore fluids: new results from the lab

With renewed U.S. Department of Energy (DOE) support to characterize the evolution of gas hydrate systems using marine electromagnetic (EM) methods paired with laboratory studies, we extended previous electrical conductivity measurements on methane hydrate, with and without sediment, to include a liquid component. Here we report the pronounced effects of adding pure H 2 O water or NaCl-bearing brine, and we track the development of the fluid phase within samples. Pure H 2 O pore water, generated in situ through partial dissociation of methane hydrate at 5°C, increases conductivity by at least a factor of 3 (0.5 on a log scale), as water accumulates in roughly 15 ± 5 vol.% of the sample. Brine, generated by adding NaCl to sample reactants prior to methane hydrate synthesis, elicited a considerably stronger effect; at 5°C, the addition of 2.5wt% NaCl increases conductivity by over 2 orders of magnitude (log-scale) relative to pure methane hydrate. Cryogenic scanning electron microscopy (cryo-SEM) imaging of quenched samples revealed the distribution of the liquid component within samples, thus allowing evaluation of conduction mechanisms and pathways.

58 GEOSCIENCES↗