Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Shifting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Stress dependence of ultrasonic velocity in unidirectional graphite/epoxy composites for longitudinal waves propagating along the direction of stress

Measurements of stress-induced velocity changes for propagation along the direction of applied stress in graphite/epoxy composites are presented. A linear relation between normalized velocity shift and stress is demonstrated for propagation and stress direction perpendicular to the fiber direction. The ratio of the SAC to the elastic compliance for this loading direction was assessed and found to have a value similar to that of numerous other materials which have very different linear elastic properties. Measurements with stress and propagation along the fibers yielded unusual behavior; the curves were very nonlinear and even shifted direction at higher loads.

Prosser, William H.↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Factors Influencing Dwell Fatigue Cracking in Notches of Powder Metallurgy Superalloys

The influences of heat treatment and cyclic dwells on the notch fatigue resistance of powder metallurgy disk superalloys were investigated for low solvus high refractory (LSHR) and ME3 disk alloys. Disks were processed to produce material conditions with varied microstructures and associated mechanical properties. Notched specimens were first subjected to baseline dwell fatigue cycles having a dwell at maximum load, as well as tensile, stress relaxation, creep rupture, and dwell fatigue crack growth tests at 704 C. Several material heat treatments displayed a bimodal distribution of fatigue life with the lives varying by two orders-of-magnitude, while others had more consistent fatigue lives. This response was compared to other mechanical properties, in search of correlations. The wide scatter in baseline dwell fatigue life was observed only for material conditions resistant to stress relaxation. For selected materials and conditions, additional tests were then performed with the dwells shifted in part or in total to minimum tensile load. The tests performed with dwells at minimum load exhibited lower fatigue lives than max dwell tests, and also exhibited early crack initiation and a substantial increase in the number of initiation sites. These results could be explained in part by modeling evolution of peak stresses in the notch with continued dwell fatigue cycling. Fatigue-environment interactions were determined to limit life for the fatigue cycles with dwells.

Gabb, T. P.↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

The effect of filler aspect ratio on the electromagnetic properties of carbon-nanofibers reinforced composites

The effect of filler aspect ratio on the electromagnetic properties of epoxy-amine resin reinforced with carbon nanofibers is here investigated. A heat treatment at 2500 °C of carbon nanofibers seems to increase their aspect ratio with respect to as-received ones most likely due to a lowering of structural defects and the improvement of the graphene layers within the dixie cup conformation. These morphological differences revealed by Raman's spectroscopy and scanning electron microscopy analyses may be responsible for the different electrical properties of the resulting composites. The DC characterization of the nanofilled material highlights an higher electrical conductivity and a lower electrical percolation threshold for the heat-treated carbon nanofibers based composites. In fact, the electrical conductivity is about 0.107 S/m and 1.36 × 10{sup −3} S/m for the nanocomposites reinforced with heat-treated and as received fibers, respectively, at 1 wt. % of nanofiller loading, while the electrical percolation threshold falls in the range [0.05–0.32]wt. % for the first nanocomposites and above 0.64 wt. % for the latter. Moreover, also a different frequency response is observed since the critical frequency, which is indicative of the transition from a resistive to a capacitive-type behaviour, shifts forward of about one decade at the same filler loading. The experimental results are supported by theoretical and simulation studies focused on the role of the filler aspect ratio on the electrical properties of the nanocomposites.

36 MATERIALS SCIENCE↗

Changing character of rainfall in eastern China, 1951–2007

The topography and continental configuration of East Asia favor the year-round existence of storm tracks that extend thousands of kilometers from China into the northwestern Pacific Ocean, producing zonally elongated patterns of rainfall that we call “frontal rain events.” In spring and early summer (known as “Meiyu Season”), frontal rainfall intensifies and shifts northward during a series of stages collectively known as the East Asian summer monsoon. Using a technique called the Frontal Rain Event Detection Algorithm, we create a daily catalog of all frontal rain events in east China during 1951–2007, quantify their attributes, and classify all rainfall on each day as either frontal, resulting from large-scale convergence, or nonfrontal, produced by local buoyancy, topography, or typhoons. Our climatology shows that the East Asian summer monsoon consists of a series of coupled changes in frontal rain event frequency, latitude, and daily accumulation. Furthermore, decadal changes in the amount and distribution of rainfall in east China are overwhelmingly due to changes in frontal rainfall. We attribute the “South Flood–North Drought” pattern observed beginning in the 1980s to changes in the frequency of frontal rain events, while the years 1994–2007 witnessed an uptick in event daily accumulation relative to the rest of the study years. This particular signature may reflect the relative impacts of global warming, aerosol loading, and natural variability on regional rainfall, potentially via shifting the East Asian jet stream.

54 ENVIRONMENTAL SCIENCES↗

Constant Frequency ZVS PWM Converter

In this paper, a simple yet novel buck or boost adaptive zero-voltage switching (ZVS) converter topology is proposed for soft switching pulse-width modulation (PWM) dc / dc converters. The converter is designed for the high switching frequency that can achieve high efficiency by reducing switching losses for the entire load range at low and high power. Besides, the output at the load terminals is maintained by a PWM signal at a fixed switching frequency, a phase shift signal between converter ports (legs) controls the system circulating current in order to provide the ZVS condition in all load conditions. With the proposed controller, the converter, thus, is suitable for high switching frequency and high-power applications with the small volume. The proposed dc / dc converter operation is analyzed, designed, and confirmed by simulation results for 240 V input, 400 V / 5 A output, and 200 kHz operating frequency at full load.

Asa, Erdem↗

Development of ceria-supported metal-oxide (MO x /CeO 2 ) catalysts via a one-pot chemical vapor deposition (OP-CVD) technique: Structure and reverse water gas shift reaction study

Current synthesis techniques for metal oxide (MO x )-supported catalysts have certain limitations of undesired target loading, ineffective dispersion of active species over the surface, uncontrolled particle size of active species, and complicated synthesis steps. Here, we developed a one-pot chemical vapor deposition (OP-CVD) methodology; by using which a solid metal precursor forms a vapor in a controlled condition and gets supported over the surrounding matrix. The theoretical stability followed by experimental validation using TGA is crucial for selecting the metal precursors. Three simple steps viz. premixing, dispersion, and rapid fixation by calcination are involved in the catalyst development via the OP-CVD approach. This study solely focused on the synthesis of 3d transition MO x over ceria support. The physicochemical characterizations of the prepared catalysts were performed by XRD, ICP-OES, SEM-EDX, CO pulse chemisorption, XANES, and EXAFS analyses to understand the crystal structure of involved species, target metal loading, dispersion, and particle size and prove the feasibility and viability of OP-CVD. The prepared catalysts were further tested for reverse water gas shift (RWGS) reaction to link their structural information with activity. The RWGS reaction data showed that the CO activity and CO selectivity were metal - and metal precursor-dependent. Higher CO activity of > 0.1 mol/h g-cat was observed for Cu and Co-based catalysts, with CO selectivity of ~100 %. This study provides an opportunity to produce efficient supported catalysts in a convenient way, providing effective catalytic activity.

36 MATERIALS SCIENCE↗

Descriptive Linear modeling of steady-state visual evoked response

A study is being conducted to explore use of the steady state visual-evoke electrocortical response as an indicator of cognitive task loading. Application of linear descriptive modeling to steady state Visual Evoked Response (VER) data is summarized. Two aspects of linear modeling are reviewed: (1) unwrapping the phase-shift portion of the frequency response, and (2) parsimonious characterization of task-loading effects in terms of changes in model parameters. Model-based phase unwrapping appears to be most reliable in applications, such as manual control, where theoretical models are available. Linear descriptive modeling of the VER has not yet been shown to provide consistent and readily interpretable results.

Levison, W. H.↗

Nonsteady Load Responses to Daytime Atmospheric Turbulence Eddies on the DOE 1.5 MW Wind Turbine at NREL

Field data collected from the NREL/GE 1.5MW wind turbine (WT) and met tower (MetT) at the NREL Wind Technology Center near Boulder, CO June-October 2018 were analyzed to quantify the impacts of turbulence eddies on the load responses measured from sensors on the main shaft, blade and tower. The passage of individual mountain-generated eddies from the met tower to the WT were critically determined by correlating the optimal time shifts in signal between MetT and nacelle anemometers with mean advection time. Loading responses from mountain eddy passage were compared with atmospheric eddies from the north/south, unimpeded by the mountains, and found to be similar. Whereas time variations in torque were highly correlated with time changes in horizontal eddy velocity, the out-of-plane bending moments on the main shaft (directly forcing the main bearing) were uncorrelated with horizontal eddy velocity. This result is consistent with a previous LES study indicating that the main bearing is forced by asymmetrical interactions between the WT rotor and turbulence eddies, while power fluctuations respond primarily to advective eddy velocity. Surprisingly, the nacelle anemometer produced statistics very similar to the MetT.

ENGINEERING,WIND ENERGY↗

Empirical characterization of vertical-tube inlets in hot-water storage tanks

Hot-water storage in residential and commercial tanks is of growing interest for peak-shifting the electrical demand associated with hot-water loads. How the water enters the tank can significantly affect the extraction efficiency of the storage. Vertical-tube inlets (VTIs) direct cold water into the tank. The VTI design influences whether large-scale mixing occurs, which can reduce the delivery capacity of the hot-water storage. In this work, the mixing at the VTI discharge was characterized by the eddy diffusivity factor (EDF) in an allometric curve fit to the ratio Re:Ri using inlet superficial velocities. The full experimental campaign tested VTI's with Re’s between 170 and 22,300 and Ri's between 0 and 376. Animated visualization of the experimentally measured data is provided, showing tank temperature evolution during inlet flows. The most predictive correlations for EDF are for VTI Re in the transition zone (i.e. ~2300 < Re < ~10,000) and at a Ri corresponding to a stably stratified tank (i.e. Ri > 5). For vertical-tubes that distribute cold water below the thermocline, increasing the EDF will decrease the stratification in a hot-water tank as EDF quantifies inlet mixing. Overall, the new correlations for VTIs can be used to design and model thermally-stratified storage tanks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Finite Model Analysis and Out of Hot Cell Surrogate Rod Testing to Analyze High Burnup Used Nuclear Fuel Mechanical Properties

Based on a series of FEA simulations, the discussions and the conclusions concerning the impact of the interface bonding efficiency to SNF vibration integrity are provided in this report; this includes the moment carrying capacity distribution between pellets and clad, and the impact of cohesion bonding on the flexural rigidity of the surrogate rod system. As progressive de-bonding occurs at the pellet-pellet interfaces and at the pellet-clad interface, the load ratio of the bending moment carrying capacity gradually shifts from the pellets to the clad; the clad starts to carry a significant portion of the bending moment resistance until reaching the full de-bonding state at the pellet-pellet interface regions. This results in localized plastic deformation of the clad at the pellet-pellet-clad interface region; the associated plastic deformations of SS clad leads to a significant degradation in the stiffness of the surrogate rod. For instance, the flexural rigidity was reduced by 39% from the perfect bond state to the de-bonded state at the pellet-pellet interfaces.

fuel-pellet interface↗

Distribution Capacity Expansion Planning: Current Practice, Opportunities, and Decision Support

The distribution utility industry and its engineers are experiencing monumental shifts in consumer needs and expectations. Characterizing future native loads as compared to net load demand for long-term capacity planning is especially difficult, as consumers are increasingly adopting prosumer technologies. This paper is the culmination of 5 months of utility interviews coordinated by the National Renewable Energy Lab (NREL) and Kevala, Inc. (Kevala) to better understand distribution capacity planning challenges. The interviews covered all aspects of capacity planning including load and DER forecasting, criteria for assessing system constraints, solution types, and organizational and decision-making structures. Our intent is to provide insight into distribution capacity planning decision support needs for utilities and the increasing number of stakeholders involved, from state and regulatory agencies to community and solution providers with interest in increasing their understanding in the distribution capacity planning process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Intra-Cycle Detection of Pre-Ignition Events through Phase-Space Transforms of Cylinder Pressure Data

The widespread adoption of boosted, downsized SI engines has brought pre-ignition phenomena into greater focus, as the knock events resulting from pre-ignitions can cause significant hardware damage. Much attention has been given to understanding the causes of pre-ignition and identify lubricant or fuel properties and engine design and calibration considerations that impact its frequency. This helps to shift the pre-ignition limit to higher specific loads and allow further downsizing but does not fundamentally eliminate the problem. Real-time detection and mitigation of pre-ignition would thus be desirable to allow safe engine operation in pre-ignition-prone conditions. This study focuses on advancing the time of detection of pre-ignition in an engine cycle where it occurs. Furthermore, phase space transforms through time-delay embedding of cylinder pressure and principal component analysis were applied to same-cycle detection of pre-ignition and shown to enable detection on the order of a crank degree earlier than deviation in cylinder pressure can be identified through direct statistical observation of the pressure data. Additionally, it appears that the deviation of the trajectory in phase space may offer the opportunity to extend this method to further extend the detection window and allow more time for mitigation actions to occur.

42 ENGINEERING↗

Experimental investigation of a double-diffused MOS structure

Self-aligned polysilicon gate technology was applied to double-diffused MOS (DMOS) construction in a manner that retains processing simplicity and effectively eliminates parasitic overlap capacitance because of the self-aligning feature. Depletion mode load devices with the same dimensions as the DMOS transistors were integrated. The ratioless feature results in smaller dimension load devices, allowing for higher density integration with no increase in the processing complexity of standard MOS technology. A number of inverters connected as ring oscillators were used as a vehicle to test the performance and to verify the anticipated benefits. The propagation time-power dissipation product and process related parameters were measured and evaluated. This report includes (1) details of the process; (2) test data and design details for the DMOS transistor, the load device, the inverter, the ring oscillator, and a shift register with a novel tapered geometry for the output stages; and (3) an analytical treatment of the effect of the distributed silicon gate resistance and capacitance on the speed of DMOS transistors.

Lin, H. C.↗

Reduction of fluctuating pressure loads in shock wave turbulent boundary layer interactions

Fluctuating surface pressure measurements have been made to investigate the effectiveness of boundary layer separators (BLS's) in reducing the fluctuating pressure loads produced by separated shock wave turbulent boundary layer interactions. Measurements have been made under unswept and swept compression corner interactions in a Mach 5 flow. BLS's fix the separation location and eliminate the large-amplitude, low-frequency fluctuating pressure loads upstream of the compression corners. The loads on the unswept compression corner face are reduced by as much as 59%. The BLS's also shift the mean pressure distribution on the unswept corner face in the streamwise direction. Results show that the loads on the corner face vary with the BLS height and the distance between the BLS and the compression corner. Suggestions for the optimum placement and the use of the BLS's are also made.

Barter, John W.↗

Transonic Loads Characteristics of a 3-Percent-Thick 60 deg Delta-Wing-Body

An investigation has been made in the Langley 16-foot transonic tunnel to determine the aerodynamic loading characteristics of a 3-percent-thick, aspect-ratio - 2.06, 60 deg delta-wing-body combination. The Mach number range was from 0.80 t o 1.05 and the average Reynolds number based on wing mean aerodynamic chord was 10 x 10(exp 6). The angle-of-attack range was from 0 deg to 26 deg but was limited at the highest Mach numbers by tunnel drive power. Pressure distributions, spanwise loadings, integrated wing coefficients, and tabulated pressure coefficients are presented for the range of Mach numbers and angles of attack. The results indicate that a free leading-edge separation vortex is the dominant flow-field phenomenon at all Mach numbers and that, consequently, there are only slight changes in the spanwise loadings with Mach number. There is a slight outboard shift in center of pressure with an increase in Mach number. The chord-wise position of the center of pressure varies from 46 t o 55 percent of the mean aerodynamic chord when the Mach number i s increased from 0.80 to l.05.

Swihart, John M.↗