Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load forecasting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

German experiences in local fatigue monitoring

The ageing management of nuclear power plants (NPP) has gained an increasing importance in the last years. The reasons are mainly due to the international context of extending period of plants operation. Moreover, new scientific discoveries, such as the corrosive influence of the medium on the fatigue process (environmentally assisted fatigue - EAF) play an important role and influence the code development (ASME, EAF code cases). The fatigue damage process takes a central position in ageing mechanisms of components. It must be ensured through appropriate evidence that facilities are being operated under allowable boundary conditions. In the design phase of NPP, fatigue analyses are still based on theoretical considerations and empirical values, which are summarized in the design transient catalogue, necessary for licensing. These analyses aim at proving the admissibility of the loads in terms of stress and fatigue usage. These analyses will also provide the fatigue-relevant positions in the NPP and give a basis for future design improvements and optimization of operating modes. The design transients are in practice conservatively correlated with the real transients occurring during operation. Uncertainties reveal very conservative assumptions regarding forecast temperatures, temperature gradients and frequencies of events. During operation of the plant, it has to be recurrently proved, that the plant is being operated under designed boundary conditions. Moreover, operating signals are constantly acquired to enable a fatigue evaluation. For example, in Germany fatigue evaluation is based on decades of experience and regulatory requirements. The rule KTA 3201.4 [1] establishes the rules for qualified fatigue monitoring. The rule DIN 25475-3 [2] on fatigue monitoring systems is available in draft version. Experience shows that some significant differences occur between the design transients and the real occurred transients during plant operation. The reasons for it are the various manual control options and also different operating modes. It is clear that showing the covering of real loads by design loads, requires a relatively complex and well-qualified detection process. The difficulty of this task is increased due to the lack of data or incomplete information and the exclusive reliance on existing operation plant data. The strategy of employing local fatigue monitoring is a straightforward solution enabling the direct measurement of loads on the fatigue-sensitive zones. Nowadays a direct derivation of the complete stress tensor at the fatigue-relevant locations is enabled thanks to the recorded local loads and combination with finite element (FE) analyses. So, additionally to the recorded temperature curves, a representation of the time evolution of the six stress components for each monitored component is possible. This allows the application of the simplified elasto-plastic fatigue check according to design codes. The fatigue level can be realistically analyzed with a suitable cycle-counting method. Furthermore, the knowledge of the time evolution of the stresses and strains enables to take into account an environmental factor to include the corrosive fluid influence in the calculations. Without local recording, it is impossible to calculate realistic fatigue usage. AREVA offers the AREVA fatigue concept (AFC) and the new fatigue monitoring system integrated (FAMOSi), necessary tools to monitor local fatigue and to provide realistic assessment. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impacts of COVID-19 related stay-at-home restrictions on residential electricity use and implications for future grid stability

“Stay-at-home” orders and other health precautions enacted during the COVID-19 pandemic have led to substantial changes in residential electricity usage. Here, we conduct a case study to analyze data from 390 apartments in New York City (NYC) to examine the impacts of two key drivers of residential electricity usage: COVID-19 case-loads and the outdoor temperature. We develop a series of regression models to predict two characteristics of residential electricity usage on weekdays: The average occupied apartment’s consumption (kWh) over a 9am-5pm window and the hourly peak demand (Watt) over a 12pm-5pm window. Via a Monte Carlo simulation, we forecast the two usage characteristics under a possible scenario in which stay-at-home orders in NYC, or a similar metropolitan region, coincide with warm summer weather. Under the scenario, the 9am-5pm residential electricity usage on weekdays is predicted to be 15% – 24% higher than under prior, pre-pandemic conditions. This could lead to substantially higher utility costs for residents. Additionally, we predict that the residential hourly peak demand between 12pm and 5pm on weekdays could be 35% – 53% higher than that under pre-pandemic conditions. We conclude that the projected increase in peak demand - which might arise if stay-at-home guidelines coincided with hot weather conditions - could pose grid management challenges, especially for residential feeders. We also note that, if there is a longer lasting shift towards work and study-from-home, utilities will have to rethink load profile considerations. The applications of our predictive models to managing future smart-grid technology are also highlighted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Health and climate impacts of future United States land freight modelled with global-to-urban models

We forecast emissions, health and climate impacts of freight truck and rail transportation in the United States under various policies between 2010 and 2050. We use a system-of-systems approach, combining models of downscaled economy, modal choice, network loading, urban development, and emission technology. We predict that overall air pollutant emissions and health impacts from the freight-truck-rail system will be greatly reduced from 2010 to 2030, but climate forcing will continue to increase if petroleum remains the dominant fuel source. A carbon tax could shift freight shipments from trucking to the more energy efficient rail, providing the greatest climate benefits among all policies, whereas a policy enforcing truck fleet maintenance could cause the largest reduction in air pollutant emissions, offering the largest health benefits. Increasing urban compactness could reduce freight activity but increase population exposure per unit emission , offering a slightly positive health benefit over the current trend of urban decentralization.

Liu, Liang↗

Stochastic Models, Indices & Optimization Algorithms for Pricing & Hedging Reliability Risks in Modern Power Grids: Data Plan - Princeton

We collected and cleaned the synthetic grid data produced by NREL for the Texas and New York synthetic grids. We developed a high dimensional joint stochastic model for load at the zone level, and solar and wind power productions at the asset level, capturing the spatial and temporal dependencies between all the variables, and demonstrated how such a model could be fitted to historical data. We designed and implemented a simulation engine which can produce Monte Carlo scenarios for the hourly day-ahead values of load, and solar and wind power productions at the spatial and temporal resolutions of the historical data used to fit the model. Finally we developed an open-source Python package which can, from an input grid model, efficiently use forecasts and large numbers of Monte Carlo scenarios to provide unit commitment and economic dispatch for each of these scenarios. The high dimensional stochastic model and the subsequent Monte Carlo simulation engine were implemented in the package PGscen and the corresponding UC and ED optimization programs in the package Vatic.

14 SOLAR ENERGY↗

Effectively Considering the Distribution System in Integrated Resource Plans

While electricity planning practices vary by state and utility based on utility type and market structure, integrated resource planning (IRP) remains a prominent vehicle — even in states with centrally-organized wholesale electricity markets. IRP focuses on meeting forecasted long-term electricity needs. Typically, utilities have not considered impacts of design and operation of the low-voltage distribution network in IRP. With advanced capabilities of grid-edge technologies to generate and store electricity and provide load flexibility, and large utility investments in distribution systems, it's increasingly important to consider at least some distribution planning elements in IRP. This report considers the value proposition for doing so, such as reducing utility costs through resource co-optimization and strategic siting of grid-edge resources, and idenfities the most important touchpoints between planning for bulk power and distribution systems and provide a range of tactics for integrating these two processes.

Relf, Grace [Lawrence Berkeley National Laboratory↗

Prediction of Air Conditioning Load Response for Providing Spinning Reserve - ORNL Report

This report assesses the use of air conditioning load for providing spinning reserve and discusses the barriers and opportunities. Air conditioning load is well suited for this service because it often increases during heavy load periods and can be curtailed for short periods with little impact to the customer. The report also provides an appendix describing the ambient temperature effect on air conditioning load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tri-level hybrid interval-stochastic optimal scheduling for flexible residential loads under GAN-assisted multiple uncertainties

Various building loads, such as heating, ventilation, and air conditioners (HVACs), electric water heaters (EWHs), and electric vehicles (EVs), can introduce opportunities for improving the flexibility of electricity consumption while satisfying the needs of building owners as well as benefiting the resilience of distribution system. To utilize such flexibility, a tri-level distribution market framework is established, including residential consumers, load aggregators (LAs), and the distribution system operator (DSO). In this work, the uncertainties from all three levels are considered. The random consumption behavior at the consumer level is modeled as a Gaussian noise that is also aggregated and transmitted to the LA level. The weather temperature in the LA level is forecasted as an interval, and the photovoltaic (PV) power in the market-clearing level is modeled by a set of power scenarios generated by Generative Adversarial Networks (GANs). Then, a hybrid interval-stochastic programming is proposed to transform the uncertain problems in the first two levels into deterministic ones. For real-time implementations, a rolling horizon optimization (RHO) scheme is employed to continuously optimize the power consumption based on the latest operating information. Finally, case studies on a modified IEEE 69-bus system validate the effectiveness of the proposed uncertainty modeling strategies and the RHO scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power and Wind Shear Implications of Large Wind Turbine Scenarios in the US Central Plains

Continued growth of wind turbine physical dimensions is examined in terms of the implications for wind speed, power and shear across the rotor plane. High-resolution simulations with the Weather Research and Forecasting model are used to generate statistics of wind speed profiles for scenarios of current and future wind turbines. The nine-month simulations, focused on the eastern Central Plains, show that the power scales broadly as expected with the increase in rotor diameter (D) and wind speeds at hub-height (H). Increasing wind turbine dimensions from current values (approximately H = 100 m, D = 100 m) to those of the new International Energy Agency reference wind turbine (H = 150 m, D = 240 m), the power across the rotor plane increases 7.1 times. The mean domain-wide wind shear exponent (α) decreases from 0.21 (H = 100 m, D = 100 m) to 0.19 for the largest wind turbine scenario considered (H = 168 m, D = 248 m) and the frequency of extreme positive shear (α > 0.2) declines from 48% to 38% of 10-min periods. Thus, deployment of larger wind turbines potentially yields considerable net benefits for both the wind resource and reductions in fatigue loading related to vertical shear.

17 WIND ENERGY↗

Building A Simulation Model For The Prediction Of Temperature Distribution In Pulsed Laser Spot Welding Of Dissimilar Low Carbon Steel 1020 To Aluminum Alloy 6061

This paper describes the development of a computer model used to analyze the heat flow during pulsed Nd: YAG laser spot welding of dissimilar metal; low carbon steel (1020) to aluminum alloy (6061). The model is built using ANSYS FLUENT 3.6 software where almost all the environments simulated to be similar to the experimental environments. A simulation analysis was implemented based on conduction heat transfer out of the key hole where no melting occurs. The effect of laser power and pulse duration was studied.Three peak powers 1, 1.66 and 2.5 kW were varied during pulsed laser spot welding (keeping the energy constant), also the effect of two pulse durations 4 and 8 ms (with constant peak power), on the transient temperature distribution and weld pool dimension were predicated using the present simulation. It was found that the present simulation model can give an indication for choosing the suitable laser parameters (i.e. pulse durations, peak power and interaction time required) during pulsed laser spot welding of dissimilar metals.

36 MATERIALS SCIENCE↗

Improving BA Control Performance Through Advanced Regulation Requirements Prediction

The paper presents a comprehensive approach to predict balancing authority (BA) regulation requirements in order to improve BAs control performance. The proposed probabilistic approach takes into account multiple uncertain and time dependent factors affecting the system balance (e.g., wind and solar generation, electrical loads). A set of methods to predict the regulation has been developed: (1) probabilistic analysis of regulation requirements with respect to time of the day, (2) linear or nonlinear regression models linking regulation requirements to different influencing factors, (3) adopting time series forecasting techniques (e.g., autoregressive integrated moving average (ARIMA)) to account for temporal continuity and auto-correlation in the regulation requirements data. Proposed methodology has been tested and validated using actual California Independent System Operator (ISO) data.

Solar Generation, Wind Generation, Area Control Er↗

The Hidden Flexibility of the Natural Gas Network for Electric Power Operations: A Case Study of a Near-Miss Winter Event

The U.S. power sector has become increasingly reliant on gas pipeline networks to deliver fuel to natural gas power plants. In addition to supplying relatively low-cost fuel, gas networks offer generators flexibility in their operations through the ability to deliver fuel when needed by using gas storage facilities or linepack if the gas network is at an operating point below its design capacity. However, disruptions or stress events on the gas network - like those occurring in the Northeast and Texas in recent years - can result in limitations on gas availability to generators at times when generation is in short supply. Here we examine a period of stress that occurred in the winter of 2022 in the Western United States. Using data on the region's natural gas pipeline network and electric generators, we build an integrated gas and electric model that closely replicates the actual dispatch of the period. We then evaluate the implications of removing flexibility employed by the gas network operator, which during that period curtailed scheduled gas deliveries to other parties to increase deliveries to natural gas power plants, which requested more gas than initially forecasted. We find that without the flexibility supplied by the gas network operator, there would have been curtailment of gas generation due to gas offtake constraints, requiring the power system operator to redispatch relying on more expensive generation or to potentially shed load. A sensitivity exploring a wind drought further exacerbates the strain, illustrating the potential challenge of managing gas and grid interactions as systems move to higher shares of variable renewable electricity. Based on this example, we discuss potential coordination strategies between the two system operators to ensure that the power system can successfully utilize and rely on the flexibility offered by natural gas networks.

03 NATURAL GAS↗

Assessment of long-term WRF–CMAQ simulations for understanding direct aerosol effects on radiation "brightening" in the United States

Long-term simulations with the coupled WRF–CMAQ (Weather Research and Forecasting–Community Multi-scale Air Quality) model have been conducted to systematically investigate the changes in anthropogenic emissions of SO 2 and NO x over the past 16 years (1995–2010) across the United States (US), their impacts on anthropogenic aerosol loading over North America, and subsequent impacts on regional radiation budgets. In particular, this study attempts to determine the consequences of the changes in tropospheric aerosol burden arising from substantial reductions in emissions of SO 2 and NO x associated with control measures under the Clean Air Act (CAA) especially on trends in solar radiation. Extensive analyses conducted by Gan et al. (2014a) utilizing observations (e.g., SURFRAD, CASTNET, IMPROVE, and ARM) over the past 16 years (1995–2010) indicate a shortwave (SW) radiation (both all-sky and clear-sky) "brightening" in the US. The relationship of the radiation brightening trend with decreases in the aerosol burden is less apparent in the western US. One of the main reasons for this is that the emission controls under the CAA were aimed primarily at reducing pollutants in areas violating national air quality standards, most of which were located in the eastern US, while the relatively less populated areas in the western US were less polluted at the beginning of this study period. Comparisons of model results with observations of aerosol optical depth (AOD), aerosol concentration, and radiation demonstrate that the coupled WRF–CMAQ model is capable of replicating the trends well even though it tends to underestimate the AOD. In particular, the sulfate concentration predictions were well matched with the observations. The discrepancies found in the clear-sky diffuse SW radiation are likely due to several factors such as the potential increase of ice particles associated with increasing air traffic, the definition of "clear-sky" in the radiation retrieval methodology, and aerosol semi-direct and/or indirect effects which cannot be readily isolated from the observed data.

54 ENVIRONMENTAL SCIENCES↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Probabilistic Reasoner Based on Bayes Risk for Damage Detection in Structural Systems

Structural health monitoring (SHM) systems are used to inform operation of structural systems subject to loads and environments that may affect their integrity. SHM systems rely on continuous monitoring of the structure to determine its health state. These systems are often coupled with a model of the deployed structure to determine the consequences of changes in the system by forecasting the response to future states. These models, which may be thought of as digital twins, need to be updated to reflect the latest state of the structural system. This work makes use of an uncertainty-aware machine learning model that enforces distance preservation of the original input space to determine deviations from the training data input space distributions. This workflow enables domain shift detection to determine whether damage is present in the structure. The uncertainty metrics generated by this network are then used in a Bayes risk framework to design an optimal damage detector given cost and risk considerations. The approach is demonstrated on a computational example with simulated damage.

Najera-Flores, David [ATA Engineering, Inc.]↗

Scientific challenges to characterizing the wind resource in the marine atmospheric boundary layer

Abstract. With the increasing level of offshore wind energy investment, it is correspondingly important to be able to accurately characterize the wind resource in terms of energy potential as well as operating conditions affecting wind plant performance, maintenance, and lifespan. Accurate resource assessment at a particular site supports investment decisions. Following construction, accurate wind forecasts are needed to support efficient power markets and integration of wind power with the electrical grid. To optimize the design of wind turbines, it is necessary to accurately describe the environmental characteristics, such as precipitation and waves, that erode turbine surfaces and generate structural loads as a complicated response to the combined impact of shear, atmospheric turbulence, and wave stresses. Despite recent considerable progress both in improvements to numerical weather prediction models and in coupling these models to turbulent flows within wind plants, major challenges remain, especially in the offshore environment. Accurately simulating the interactions among winds, waves, wakes, and their structural interactions with offshore wind turbines requires accounting for spatial (and associated temporal) scales from O(1 m) to O(100 km). Computing capabilities for the foreseeable future will not be able to resolve all of these scales simultaneously, necessitating continuing improvement in subgrid-scale parameterizations within highly nonlinear models. In addition, observations to constrain and validate these models, especially in the rotor-swept area of turbines over the ocean, remains largely absent. Thus, gaining sufficient understanding of the physics of atmospheric flow within and around wind plants remains one of the grand challenges of wind energy, particularly in the offshore environment. This paper provides a review of prominent scientific challenges to characterizing the offshore wind resource using as examples phenomena that occur in the rapidly developing wind energy areas off the United States. Such phenomena include horizontal temperature gradients that lead to strong vertical stratification; consequent features such as low-level jets and internal boundary layers; highly nonstationary conditions, which occur with both extratropical storms (e.g., nor'easters) and tropical storms; air–sea interaction, including deformation of conventional wind profiles by the wave boundary layer; and precipitation with its contributions to leading-edge erosion of wind turbine blades. The paper also describes the current state of modeling and observations in the marine atmospheric boundary layer and provides specific recommendations for filling key current knowledge gaps.

17 WIND ENERGY↗

Hourly Load Profile Dataset for Electric Transit Bus Depots in the United States

Transit buses operate primarily in dense urban areas, where nearby populations face increased exposure to fine particulates, nitrogen oxides, and other harmful pollutants. Electrifying transit buses presents a clear opportunity to reduce greenhouse gas emissions and improve urban air quality. However, widespread adoption may pose significant energy and infrastructure challenges, which can be mitigated through proactive planning and investment. This report presents a robust modeling framework and an initial estimation of the hourly electricity demand at transit bus depots across the United States. The resulting depot-level dataset, available at data.nrel.gov/submissions/282, provides valuable insights for infrastructure planning and electricity demand forecasting, supporting the scalable electrification of transit bus fleets nationwide.

33 ADVANCED PROPULSION SYSTEMS↗

Prediction of crack propagation paths in the unit cell of SOFC stacks

Planar Solid Oxide Fuel Cells (SOFC) stacks are multi-material layered systems with different thermo-mechanical properties. Due to their severe thermal loading, these layers have to meet high demands to preserve their mechanical integrity without initiation and propagation of fracture. Here, we focus on a typical unit cell of the stack which consists of positive electrode-electrolyte-negative electrode (PEN). Based on the mechanical properties of each layer and their interfaces, an energy criterion as a function of crack length is used for the prediction of possible crack extensions in the PEN. This criterion is a pure local criterion, independent of applied loads and geometry of the specimen. An analysis of the competition between crack deflections in the interfaces and crack penetration in layers is presented.

30 DIRECT ENERGY CONVERSION↗

Great Plains Wind Energy Transmission Development Project

In fiscal year 2005, the Energy & Environmental Research Center (EERC) received funding from the U.S. Department of Energy (DOE) to undertake a broad array of tasks to either directly or indirectly address the barriers that faced much of the Great Plains states and their efforts to produce and transmit wind energy at the time. This program, entitled Great Plains Wind Energy Transmission Development Project, was focused on the central goal of stimulating wind energy development through expansion of new transmission capacity or development of new wind energy capacity through alternative market development. The original task structure was as follows: Task 1 - Regional Renewable Credit Tracking System (later rescoped to Small Wind Turbine Training Center); Task 2 - Multistate Transmission Collaborative; Task 3 - Wind Energy Forecasting System; and Task 4 - Analysis of the Long-Term Role of Hydrogen in the Region. As carried out, Task 1 involved the creation of the Small Wind Turbine Training Center (SWTTC). The SWTTC, located Grand Forks, North Dakota, consists of a single wind turbine, the Endurance S-250, on a 105-foot tilt-up guyed tower. The S-250 is connected to the electrical grid on the 'load side' of the electric meter, and the power produced by the wind turbine is consumed locally on the property. Establishment of the SWTTC will allow EERC personnel to provide educational opportunities to a wide range of participants, including grade school through college-level students and the general public. In addition, the facility will allow the EERC to provide technical training workshops related to the installation, operation, and maintenance of small wind turbines. In addition, under Task 1, the EERC hosted two small wind turbine workshops on May 18, 2010, and March 8, 2011, at the EERC in Grand Forks, North Dakota. Task 2 involved the EERC cosponsoring and aiding in the planning of three transmission workshops in the midwest and western regions. Under Task 3, the EERC, in collaboration with Meridian Environmental Services, developed and demonstrated the efficacy of a wind energy forecasting system for use in scheduling energy output from wind farms for a regional electrical generation and transmission utility. With the increased interest at the time of project award in the production of hydrogen as a critical future energy source, many viewed hydrogen produced from wind-generated electricity as an attractive option. In addition, many of the hydrogen production-related concepts involve utilization of energy resources without the need for additional electrical transmission. For this reason, under Task 4, the EERC provided a summary of end uses for hydrogen in the region and focused on one end product in particular (fertilizer), including several process options and related economic analyses.

08 HYDROGEN↗