Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Magnetic Resonance Imaging and Spectroscopy to Assess Leg Muscle Macrostructure and Microstructure in Healthy Older Women: A Feasibility Assessment

Advanced magnetic resonance (MR) scanning techniques, such as diffusion tensor imaging (DTI) and proton MR spectroscopy ({sup 1}H-MRS) permit microstructural evaluation of water diffusivity and intramyocellular lipid content, respectively. We aimed to determine the feasibility of performing advanced MR scanning (proton density [PD] weighted imaging, DTI, and {sup 1}H-MRS) to evaluate properties of leg muscles in older women with respect to: (1) participant recruitment using three community-based strategies; (2) participant tolerance to the MRI scan acquisition protocol; and (3) scan acquisition and analyses protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detachment stabilization with n/m=1/1 resonant magnetic perturbation field applied to the stochastic magnetic boundary of the Large Helical Device

It is found that the remnant island structure created by n/m=1/1 resonant magnetic perturbation field in the stochastic magnetic boundary of the Large Helical Device (LHD) [A. Komori et al., Nucl. Fusion 49, 104015 (2009)] has a stabilizing effect on formation of radiating plasma, realizing stably sustained divertor detachment operation with the core plasma being unaffected. The data from the several diagnostics, (profiles of electron temperature and density, radiation and temporal evolution of divertor particle flux) indicate selective cooling around X-point of the island and thus peaked radiation there, which is stabilized outside of the last closed flux surface throughout the detachment phase. The vacuum ultraviolet spectroscopy measurements of high Z impurity (iron) emission shows significant decrease during the detachment, indicating core plasma decontamination. The results from the three-dimensional (3D) edge transport code, edge Monte Carlo 3D (EMC3) [Y. Feng et al., Contrib. Plasma Phys. 44, 57 (2004)]-EIRENE [D. Reiter et al., Fusion Sci. Technol. 47, 172 (2005)] show similar tendency in the radiation pattern. The island size and its radial location are varied to investigate the magnetic topology effects on the detachment control. The divertor particle flux and neutral pressure exhibit intermittent oscillation as well as modification of recycling pattern during the detachment, which are found to reflect the island structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of resonant magnetic perturbations on nonlinearly driven modes in drift-wave turbulence

In this work, we study the effects of resonant magnetic perturbations (RMPs) on turbulence, flows, and confinement in the framework of resistive drift wave turbulence. We extend the Hasegawa-Wakatani model to include RMP fields. The effect of the RMPs is to induce a linear coupling between the zonal electric field and the zonal density gradient, which drives the system to a state of electron radial force balance for large ({delta}B{sub r}/B{sub 0}). Both the vorticity flux (Reynolds stress) and particle flux are modulated. We derive an extended predator prey model which couples zonal potential and density dynamics to the evolution of turbulence intensity. This model has both turbulence drive and RMP amplitude as control parameters and predicts a novel type of transport bifurcation in the presence of RMPs. We find states that are similar to the ZF-dominated state of the standard predator-prey model, but for which the power threshold is now a function of the RMP strength. For small RMP amplitude, the energy of zonal flows decreases and the turbulence energy increases with ({delta}B{sub r}/B{sub 0}), corresponding to a damping of zonal flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of particle exhaust control during ELM suppression by resonant magnetic perturbations in DIII-D

A reduction in plasma electron density ('pump-out') during the application of resonant magnetic perturbations (RMPs) on DIII-D precedes the suppression of edge localized modes (ELMs) in discharges with low (<= 0.2) electron pedestal collisionalities. The magnitude of the density drop near the plasma pedestal can be up to 30% and as low as similar to 2% for discharges with similar applied RMP, and thus motivates further study to determine the cause of the variation. Based on an analysis of the global particle balance and measurements of the D-alpha poloidal distribution, it is shown that the wall inventory can be strongly affected by changing the average triangularity ( ) of the discharge. Specifically, particle balance in = 0.3 discharges shows that the density pump-out was substantially higher than the increase in particle exhaust to the cryo-pumps, i.e. wall pumping was apparently required. On the other hand, particle balance in = 0.5 discharges shows that the density pump-out was offset by an increase in exhaust to the cryo-pumps, i.e. wall pumping was not required. Correspondingly, the D-alpha intensity increased by similar to 50%-100% at = 0.5 during the RMP phase of the discharge when compared with theRMPphase of a = 0.3 discharge. Both of these observations imply a possible increase in the neutral particles in the scrape-off-layer. More significantly, this new result demonstrates density pump-out and ELM suppression without significant wall pumping, which is a desirable feature for long-pulse reactors with saturated walls.

Unterberg, E. A.↗

Impact of resonant magnetic perturbations on zonal flows and microturbulence

Results from a joint experimental and computational effort studying the effect of resonant magnetic perturbations (RMPs) on microturbulence levels and their connection to zonal flows in the DIII-D tokamak L-mode are presented. Beam emission spectroscopy measurements show a direct increase in density fluctuations at microturbulent scales with increasing RMP amplitude, suggesting that magnetic activity introduced by the RMP affects the regulation of microturbulence on DIII-D. This is analogous to how MHD-scale magnetic fluctuations arising from tearing modes have been observed in simulations to increase microturbulence levels in the reversed-field pinch (RFP). In the RFP, this is attributed to magnetic fluctuations eroding turbulence-limiting zonal flows; this work examines if a similar mechanism is present for DIII-D microturbulence. Gyrokinetic simulations find that the application of an RMP corresponds directly to a decrease in zonal flow levels, producing a similar increase of turbulent fluctuation levels over a range of RMP amplitudes as observed in the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigations of plasma response associated with resonant magnetic perturbation fields using perturbation method in KSTAR H-mode plasmas

Abstract The plasma response associated with the resonant magnetic perturbation (RMP) field was investigated using the small edge perturbations induced by a modulated supersonic molecular beam injection (SMBI) in KSTAR. The modulated SMBI provides a time-varying perturbation of the plasma density source in the region just inside the last closed flux surface and a modulated flow damping rate. Radial propagation of the toroidal rotation perturbation induced by SMBI from the q = 3 surface to the q = 2 surface was observed. Theoretical analysis using the general perturbed equilibrium code of the RMP intensity profiles of the RMP field is consistent with the phase profile of the toroidal rotation perturbation.

Physics↗

SU-E-J-157: Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation

Purpose: To develop an imaging technique that enables us to acquire T2- weighted 4D Magnetic Resonance Imaging (4DMRI) with sufficient spatial coverage, temporal resolution and spatial resolution for clinical evaluation. Methods: T2-weighed 4DMRI images were acquired from a healthy volunteer using a respiratory amplitude triggered T2-weighted Turbo Spin Echo sequence. 10 respiratory states were used to equally sample the respiratory range based on amplitude (0%, 20%i, 40%i, 60%i, 80%i, 100%, 80%e, 60%e, 40%e and 20%e). To avoid frequent scanning halts, a methodology was devised that split 10 respiratory states into two packages in an interleaved manner and packages were acquired separately. Sixty 3mm sagittal slices at 1.5mm in-plane spatial resolution were acquired to offer good spatial coverage and reasonable spatial resolution. The in-plane field of view was 375mm × 260mm with nominal scan time of 3 minutes 42 seconds. Acquired 2D images at the same respiratory state were combined to form the 3D image set corresponding to that respiratory state and reconstructed in the coronal view to evaluate whether all slices were at the same respiratory state. 3D image sets of 10 respiratory states represented a complete 4D MRI image set. Results: T2-weighted 4DMRI image were acquired in 10 minutes which was within clinical acceptable range. Qualitatively, the acquired MRI images had good image quality for delineation purposes. There were no abrupt position changes in reconstructed coronal images which confirmed that all sagittal slices were in the same respiratory state. Conclusion: We demonstrated it was feasible to acquire T2-weighted 4DMRI image set within a practical amount of time (10 minutes) that had good temporal resolution (10 respiratory states), spatial resolution (1.5mm × 1.5mm × 3.0mm) and spatial coverage (60 slices) for future clinical evaluation.

60 APPLIED LIFE SCIENCES↗

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effect of aspect ratio on plasma response to resonant magnetic perturbations in tokamak devices

A systematic numerical study is carried out, computing and comparing the plasma response to the resonant magnetic perturbation (RMP) field, applied for controlling edge localized modes (ELMs), in a series of tokamak plasmas with varying aspect ratio and utilizing the MARS-F code. The aspect ratio is scanned either by varying the plasma major radius at a fixed minor radius or by varying the latter while fixing the former. Both approaches yield similar results when compared in terms of quantities with proper normalizations. In general, a non-monotonic dependence of the resonant response field (normalized by the vacuum counterpart) near the plasma edge is found with varying aspect ratio, indicating that a given ELM control coil current configuration strongly favors plasmas with a certain aspect ratio. This optimal aspect ratio, on the other hand, depends on the toroidal as well as poloidal (i.e., coil phasing) spectra of the applied RMP field. The equilibrium (edge) safety factor, the plasma shape, and the plasma toroidal flow are all fixed to ensure that the effects identified here are predominantly due to the plasma aspect ratio.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Revealing Molecular Mechanisms in Hierarchical Nanoporous Carbon via Nuclear Magnetic Resonance

Hierarchical nanoporous carbons (HNC) have been proven to be an effective adsorbent for the adsorption of volatile organic compounds (VOCs) and CO 2 . However, questions remain regarding the hierarchical structure regulation, the adsorption mechanisms of adsorbate uptake, and interactions within the HNC. Here, we synthesize HNC from wood, using a microwave-induced heating method incorporating K 2 CO 3 activation. Our HNC exhibit Murray's law multiscale structures, prompting a molecular-scale study of adsorbate adsorption via nuclear magnetic resonance (NMR). NMR chemical shifts are consistent with ring-current effects from the adsorbent. Our NMR technique provides a convenient way to quantitate adsorption of adsorbate in HNC. VOC vapor adsorption results show NMR chemical-shift changes with time, suggesting initial adsorption into mesopores, followed by diffusion into micropores. Schroeder's paradox is demonstrated by differences in observed shifts for adsorbed liquid vis-à-vis vapor phase in these HNC. These HNC show high CO 2 adsorption capacity, portending applications to carbon capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Readout of Oriented Triplet Excitons in Linear Acenes via Room-Temperature Electrically Detected Magnetic Resonance

In this study, optically generated molecular spin centers offer an attractive platform for room-temperature spintronic and quantum applications. The linear acene family of molecules are especially good candidates due to their efficient generation of highly polarized triplet excitons via singlet fission. However, the direct detection and manipulation of these spin centers in thin films via the electrical means desirable for ultimate microelectronic devices has proven challenging. In particular, highly oriented triplet features have previously been detected in crystalline anthracene but longer acenes reveal only doublet features in Electrically-Detected Magnetic Resonance (EDMR). In this work we present EDMR spectra of highly oriented triplet excitons in pentacene for the first time, using a host-guest style device made of tetracene and pentacene. The guest acts as an energetic trap site, permitting the isolation and detection of molecular triplets at room temperature. Modeling of these results shows that the observed resonance features correspond to triplet sublevel transitions on isolated pentacene guest molecules. Rotation of the applied field confirms the tendency of the linear acenes to self-orient with the longest molecular axis perpendicular to the device substrate. Lastly, we find the disappearance of resonant triplet features in the neat acenes is not primarily due to the effects of exciton delocalization, but a broader mechanism of spin relaxation primarily influenced by exciton diffusivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring the internal swelling in cementitious mortars with single-sided 1H nuclear magnetic resonance

Moisture transport into concrete and mortar surfaces strongly influences the durability of structures. Transport processes are foremost controlled by the material's porosity. Cementitious materials, such as concrete and mortars, exhibit distinct changes in pore structure while drying and subsequent rewetting due to the internal shrinkage and swelling of the layered calcium-silicate hydrates. Mortars with different w/c-ratios and binders were dried and rewetted and the subsequent time dependent changes in water filled pore structure were monitored with single-sided {sup 1}H nuclear magnetic resonance. This technique combines a localized depiction of all pore water with a good time resolution. The NMR signal is split into the four pore species C-S-H interlayer water, gel pore water, interhydrate water, and capillary water by multi-exponential analysis. Two consecutive running processes in the swelling of cementitious mortars were identified and discussed based on recent models of the cement microstructure as well as its implications on the sorptivity.

36 MATERIALS SCIENCE↗

Experimental evaluation of electrical conductivity imaging of anisotropic brain tissues using a combination of diffusion tensor imaging and magnetic resonance electrical impedance tomography

Anisotropy of biological tissues is a low-frequency phenomenon that is associated with the function and structure of cell membranes. Imaging of anisotropic conductivity has potential for the analysis of interactions between electromagnetic fields and biological systems, such as the prediction of current pathways in electrical stimulation therapy. To improve application to the clinical environment, precise approaches are required to understand the exact responses inside the human body subjected to the stimulated currents. In this study, we experimentally evaluate the anisotropic conductivity tensor distribution of canine brain tissues, using a recently developed diffusion tensor-magnetic resonance electrical impedance tomography method. At low frequency, electrical conductivity of the biological tissues can be expressed as a product of the mobility and concentration of ions in the extracellular space. From diffusion tensor images of the brain, we can obtain directional information on diffusive movements of water molecules, which correspond to the mobility of ions. The position dependent scale factor, which provides information on ion concentration, was successfully calculated from the magnetic flux density, to obtain the equivalent conductivity tensor. By combining the information from both techniques, we can finally reconstruct the anisotropic conductivity tensor images of brain tissues. The reconstructed conductivity images better demonstrate the enhanced signal intensity in strongly anisotropic brain regions, compared with those resulting from previous methods using a global scale factor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bulk and Nanocrystalline Cesium Lead-Halide Perovskites as Seen by Halide Magnetic Resonance

Lead-halide perovskites increasingly mesmerize researchers because they exhibit a high degree of structural defects and dynamics yet nonetheless offer an outstanding (opto)electronic performance on par with the best examples of structurally stable and defect-free semiconductors. This highly unusual feature necessitates the adoption of an experimental and theoretical mindset and the reexamination of techniques that may be uniquely suited to understand these materials. Surprisingly, the suite of methods for the structural characterization of these materials does not commonly include nuclear magnetic resonance (NMR) spectroscopy. The present study showcases both the utility and versatility of halide NMR and NQR (nuclear quadrupole resonance) for probing the structure and structural dynamics of CsPbX 3 (X = Cl, Br, I), in both bulk and nanocrystalline forms. The strong quadrupole couplings, which originate from the interaction between the large quadrupole moments of, e.g., the 35 Cl, 79 Br, and 127 I nuclei, and the local electric-field gradients, are highly sensitive to subtle structural variations, both static and dynamic. The quadrupole interaction can resolve structural changes with accuracies commensurate with synchrotron X-ray diffraction and scattering. It is shown that space-averaged site-disorder is greatly enhanced in the nanocrystals compared to the bulk, while the dynamics of nuclear spin relaxation indicates enhanced structural dynamics in the nanocrystals. The findings from NMR and NQR were corroborated by ab initio molecular dynamics, which point to the role of the surface in causing the radial strain distribution and disorder. These findings showcase a great synergy between solid-state NMR or NQR and molecular dynamics simulations in shedding light on the structure of soft lead-halide semiconductors.

36 MATERIALS SCIENCE↗

Surface Terminations of LaAlO 3 Perovskite Nanoparticles as Viewed by Solid-State Nuclear Magnetic Resonance

Nanocrystal surfaces generally undergo reconstructions that differentiate them from the bulk structures, often in nontrivial ways. Understanding these terminations is critical across diverse fields, from heterogeneous catalysis to the formation of topological states and the synthesis of semiconductor nanomaterials. Determining surface structures is currently an interdisciplinary task, most often involving high-resolution electron microscopy and surface electron diffraction. These methods, however, do not provide a global view of the ensemble of structures present in a sample. Here, we show how surface-sensitive solid-state nuclear magnetic resonance (SSNMR) spectroscopy methods can bridge this gap. In this context, we investigated the surface structure of lanthanum aluminate (LaAlO 3 ) perovskite nanoparticles. Four distinct surface terminations have previously been observed for this material, but their relative abundances were unknown. Using an array of double- and triple-resonance SSNMR methods probing the relative proximities of surface 1 H, 27 Al, 17 O, and 139 La nuclei, we conclude the surface to be majority terminated (80%) by AlO x with substantial (20%) LaO x terminated regions.

Materials↗

Cardiac Function After Multimodal Breast Cancer Therapy Assessed With Functional Magnetic Resonance Imaging and Echocardiography Imaging

Purpose: Breast intensity modulated radiation therapy (IMRT) reduces high-dose heart volumes but increases low-dose volumes. We prospectively assessed heart changes after 3D conformal RT (3DCRT) and IMRT for left-sided breast cancer. Heart dose was analyzed individually, 3DCRT patients were moderately exposed, and IMRT was performed only in patients with unacceptably high heart doses upon 3DCRT planning. Methods and Materials: In 49 patients (38 patients received 3DCRT; 11 patients received IMRT; and 20 patients received neoadjuvant or adjuvant chemotherapy) magnetic resonance imaging (MRI) and echocardiography were performed before and at 6, 12, and 24 months after treatment. Results: Mean heart dose for IMRT was 12.9 ± 3.9 Gy versus 4.5 ± 2.4 Gy for 3DCRT. Heart volumes receiving >40 Gy were 2.6% (3DCRT) versus 1.3% (IMRT); doses were >50 Gy only with 3DCRT. Temporary ejection fraction (EF) decrease was observed on MRI after 6 months (63%-59%, P=.005) resolving at 24 months. Only 3 patients had pronounced largely transient changes of EF and left ventricular enddiastolic diameter (LVEDD). Mitral (M) and tricuspid (T) annular plane systolic excursion (MAPSE and TAPSE) were reduced over the whole cohort (still within normal range). After 24 months left ventricular remodeling index decreased in patients receiving chemotherapy (0.80 vs 0.70, P=.028). Neither wall motion abnormalities nor late enhancements were found. On echocardiography, in addition to EF findings that were similar to those on MRI, global strain was unchanged over the whole cohort at 24 months after a transient decrease at 6 and 12 months. Longitudinal strain decreased in the whole cohort after 24 months in some segments, whereas it increased in others. Conclusions: Until 24 months after risk-adapted modern multimodal adjuvant therapy, only subclinical cardiac changes were observed in both 3DCRT patients with inclusion of small to moderate amounts of heart volume in RT tangents and in the patients treated with IMRT and reduced high-dose heart exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theoretical investigation of the triggering of neoclassical tearing modes by transient resonant magnetic perturbations in NSTX

The extended perturbed equilibrium code asymptotic matching code is used to simulate the triggering of n = 1 neoclassical tearing modes (NTMs) by a pulsed, rotating, n = 1, resonant magnetic perturbation (RMP) in two example NSTX discharges. Although the two discharges are significantly different from one another, the results of the two sets of simulations are quite similar. The critical n = 1 RMP pulse amplitude required to trigger an n = 1 NTM is minimized when the RMP pulse rotation frequency matches the linear natural frequency of an n = 1 tearing mode, resonant within the plasma, that is metastable to an NTM. However, if there is a frequency mismatch, then the seed magnetic island chain driven at the relevant resonant surface is forced to rotate with respect to the RMP, because the RMP pulse amplitude is nowhere near sufficient to lock the island chain to the RMP. This rotation causes the critical RMP pulse amplitude required to trigger an NTM to oscillate as the RMP pulse duration is varied. Furthermore, the critical amplitude is minimized when the RMP pulse duration is such that seed island chain executes a half-integer number of rotations with respect to the pulse. All of the minima have the same value.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗