Search NASA⌕ Search

SEARCH · Search NASA

Results for “MCNP Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Argonne Bubble Experiment Thermal Model Development II

This report describes the continuation of the work reported in “Argonne Bubble Experiment Thermal Model Development”. The experiment was performed at Argonne National Laboratory (ANL) in 2014. A rastered 35 MeV electron beam deposited power in a solution of uranyl sulfate, generating heat and radiolytic gas bubbles. Irradiations were performed at three beam power levels, 6, 12 and 15 kW. Solution temperatures were measured by thermocouples, and gas bubble behavior was observed. This report will describe the Computational Fluid Dynamics (CFD) model that was developed to calculate the temperatures and gas volume fractions in the solution vessel during the irradiations. The previous report described an initial analysis performed on a geometry that had not been updated to reflect the as-built solution vessel. Here, the as-built geometry is used. Monte-Carlo N-Particle (MCNP) calculations were performed on the updated geometry, and these results were used to define the power deposition profile for the CFD analyses, which were performed using Fluent, Ver. 16.2. CFD analyses were performed for the 12 and 15 kW irradiations, and further improvements to the model were incorporated, including the consideration of power deposition in nearby vessel components, gas mixture composition, and bubble size distribution. The temperature results of the CFD calculations are compared to experimental measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spent Fuel Assembly Modeling for Unattended Gamma Emission Tomography (UGET) Project [Slides]

NGSI-SF project provided good basis for spent fuel assemblies. UGET assemblies have both DU pins and water replacing fuel in the center of the bundle. Both MCNP geometry files and CINDER90 isotopic compositions files were created and used by LLNL and/or others. Four different spent fuel assembly types were represented: PWR, BWR, VVER-440, and the VVER-1000. Not enough information was known about irradiation of assemblies in Forsmark or Olkiluoto (JNT 1510) benchmarks for detailed calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Modeling and Simulations for Evaluation of Thermal Neutron Scattering Materials [Slides]

In this presentation, researchers detail tradeoffs between two simulation suites for thermal neutron scattering data. OXLIMAX + MCViNE provide a more accurate elastic peak shape and NJOY + MCNP have more accurate spectra between phonon mode peaks (most likely due to multiple neutron scattering). Additionally, some outstanding issues with MCViNE are noted, including multiple neutron scattering and non-uniform (Q,E) grid for data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of respiratory motion on internal radiation dosimetry

Purpose: Estimation of the radiation dose to internal organs is essential for the assessment of radiation risks and benefits to patients undergoing diagnostic and therapeutic nuclear medicine procedures including PET. Respiratory motion induces notable internal organ displacement, which influences the absorbed dose for external exposure to radiation. However, to their knowledge, the effect of respiratory motion on internal radiation dosimetry has never been reported before. Methods: Thirteen computational models representing the adult male at different respiratory phases corresponding to the normal respiratory cycle were generated from the 4D dynamic XCAT phantom. Monte Carlo calculations were performed using the MCNP transport code to estimate the specific absorbed fractions (SAFs) of monoenergetic photons/electrons, the S-values of common positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, Y-86, and I-124), and the absorbed dose of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) in 28 target regions for both the static (average of dynamic frames) and dynamic phantoms. Results: The self-absorbed dose for most organs/tissues is only slightly influenced by respiratory motion. However, for the lung, the self-absorbed SAF is about 11.5% higher at the peak exhale phase than the peak inhale phase for photon energies above 50 keV. The cross-absorbed dose is obviously affected by respiratory motion for many combinations of source-target pairs. The cross-absorbed S-values for the heart contents irradiating the lung are about 7.5% higher in the peak exhale phase than the peak inhale phase for different positron-emitting radionuclides. For {sup 18}F-FDG, organ absorbed doses are less influenced by respiratory motion. Conclusions: Respiration-induced volume variations of the lungs and the repositioning of internal organs affect the self-absorbed dose of the lungs and cross-absorbed dose between organs in internal radiation dosimetry. The dynamic anatomical model provides more accurate internal radiation dosimetry estimates for the lungs and abdominal organs based on realistic modeling of respiratory motion. This work also contributes to a better understanding of model-induced uncertainties in internal radiation dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tritium Breeding Ratio Evaluation of Solid Breeder Concepts for the FESS-FNSF

This paper presents a parametric study of the Fusion Energy System Studies-Fusion Nuclear Science Facility’s (FNSF’s) tritium breeding performance for several solid breeder concepts, neutron multiplying materials, and blanket materials, assuming volume fractions based on the most recent FNSF design as a realistically representative fusion facility. In this study, we initially surveyed the tritium breeding ratio (TBR) of several solid breeder concepts by employing a simplified but efficient one-dimensional (1-D) infinite cylinder reduced-order model (ROM). Parametric studies were performed with the ROMs for the full range of breeder-to-multiplier ratios to identify the optimum mixture compositions for each breeder type that would lead to a maximum TBR. These optimized breeder-multiplier combinations were then homogenized with FNSF blanket component materials to estimate their impacts on the TBR. Subsequently, as a validation step for the optimal designs, TBR calculations were performed using a more realistic modified 1-D ROM with inner and outer breeding regions, as well as with a fully detailed 22.5-deg three-dimensional (3-D) sector of the FNSF to assess the impact of geometry details on the TBR. The differences between the two 1-D models were negligible, while the ROMs were able to correctly predict trends and identify the maximum and minimum TBR cases, as well as show consistent biases relative to the results produced by the full 3-D, 22.5-deg sector for specific breeder/multiplier combinations. Solid breeder concepts such as Li 2 O, Li 4 SiO 4 , and Li 8 ZrO 6 outperformed all others in this study in terms of TBR performance when combined with all the neutron multiplier materials selected. Here, an underlying goal of this study was to develop and improve rapid and reliable ROMs to aid designers during parametric optimizations of highly complex and computationally expensive fusion models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

Sensitivity-Uncertainty Based Nuclear Criticality Safety Validation

These are slides from a seminar given to the University of Mexico Nuclear Engineering Department. Whisper is a statistical analysis package developed to support nuclear criticality safety validation. It uses the sensitivity profile data for an application as computed by MCNP6 along with covariance files for the nuclear data to determine a baseline upper-subcritical-limit for the application. Whisper and its associated benchmark files are developed and maintained as part of MCNP6, and will be distributed with all future releases of MCNP6. Although sensitivity-uncertainty methods for NCS validation have been under development for 20 years, continuous-energy Monte Carlo codes such as MCNP could not determine the required adjoint-weighted tallies for sensitivity profiles. The recent introduction of the iterated fission probability method into MCNP led to the rapid development of sensitivity analysis capabilities for MCNP6 and the development of Whisper. Sensitivity-uncertainty based methods represent the future for NCS validation – making full use of today’s computer power to codify past approaches based largely on expert judgment. Validation results are defensible, auditable, and repeatable as needed with different assumptions and process models. The new methods can supplement, support, and extend traditional validation approaches.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

V&V of MCNP 6.1.1 Beta Against Intermediate and High-Energy Experimental Data

This report presents a set of validation and verification (V&V) MCNP 6.1.1 beta results calculated in parallel, with MPI, obtained using its event generators at intermediate and high-energies compared against various experimental data. It also contains several examples of results using the models at energies below 150 MeV, down to 10 MeV, where data libraries are normally used. This report can be considered as the forth part of a set of MCNP6 Testing Primers, after its first, LA-UR-11-05129, and second, LA-UR-11-05627, and third, LA-UR-26944, publications, but is devoted to V&V with the latest, 1.1 beta version of MCNP6. The MCNP6 test-problems discussed here are presented in the /VALIDATION_CEM/and/VALIDATION_LAQGSM/subdirectories in the MCNP6/Testing/directory. README files that contain short descriptions of every input file, the experiment, the quantity of interest that the experiment measures and its description in the MCNP6 output files, and the publication reference of that experiment are presented for every test problem. Templates for plotting the corresponding results with xmgrace as well as pdf files with figures representing the final results of our V&V efforts are presented. Several technical “bugs” in MCNP 6.1.1 beta were discovered during our current V&V of MCNP6 while running it in parallel with MPI using its event generators. These “bugs” are to be fixed in the following version of MCNP6. Our results show that MCNP 6.1.1 beta using its CEM03.03, LAQGSM03.03, Bertini, and INCL+ABLA, event generators describes, as a rule, reasonably well different intermediate- and high-energy measured data. This primer isn’t meant to be read from cover to cover. Readers may skip some sections and go directly to any test problem in which they are interested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An introduction to TR-X: a simplified tool for standardized analysis

TR-X is a multi-platform program that provides a graphical interface to Monte Carlo N-Particle transport (MCNP) and Monte Carlo N-Particle transport eXtended (MCNPX) codes. Included in this interface are tools to reduce the tedium of input file creation, provide standardization of model creation and analysis, and expedite the execution of the created models. TR-X provides tools to make the rapid testing of multiple permutations of these models easier, while also building in standardization that allows multiple solutions to be compared.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

DNDO Report: Developing a Photon Clutter Scaling Algorithm for Implementation into the NINESIM Tool

The Nuclear Inspection Node Event SIMulator (NINESIM) is a tool that is capable of modeling a node that monitors passing traffic for radiological and nuclear materials. This task requires the consideration of a number of factors. One such factor is clutter, or the level of traffic passing through a node. Clutter might affect the performance of radiation detectors due to attenuation or scattering that particles undergo as they move through the material. This paper discusses the results from MCNP simulations that were performed to determine in what scenarios clutter had a significant impact on detector performance, where the receiver operating characteristic (ROC) curve was used as the metric to evaluate detector performance. Clutter was found to have an insignificant impact on neutron detection, therefore, clutter may be ignored when modeling neutron detectors. However, there were a number of scenarios where clutter was found to affect the performance of photon detectors; the amount of traffic was found to be directly proportional to the effectiveness of photon detectors. The results of this work were then used to develop a photon clutter scaling algorithm that will be implemented into NINESIM. The Domestic Nuclear Detection Office, and possibly other agencies such as the Defense Threat Reduction Agency, will benefit from this work by eventually obtaining a tool that can enhance their ability in countering the illicit movement of radiological and nuclear materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Volume fraction determination of the annular three-phase flow of gas-oil-water using adaptive neuro-fuzzy inference system

The use of adaptive neuro-fuzzy inference system (ANFIS) has been reported for predicting the volume fractions in a gas–oil–water multiphase system. In fact, the volume fractions in the annular three-phase flow are measured based on a dual energy metering system consisting of {sup 152}Eu and {sup 137}Cs and one NaI detector using ANFIS. Since the summation of volume fractions is constant, therefore ANFIS must predict only two volume fractions. In this study, three ANFIS networks are applied. The first is utilized to predict the gas and water volume fractions. The next one is applied to predict the gas and oil, and the last one is used to predict the water and oil volume fractions. In the next step, ANFIS networks must be trained based on numerically obtained data from MCNP-X code. Then, the average testing errors of these three networks are computed and compared. The network with the least error has been selected as the best predictor model.

07 ISOTOPE AND RADIATION SOURCES↗

The Transmutation of Nuclear Waste in the Two-Zone Subcritical System Driven by High- Intensity Neutron Generator - 12098

The main problems of transmutation of high-level radioactive waste (minor actinides and long-lived fission products) are considered in our work. The range of radioactive waste of nuclear power is analyzed. The conditions under which the transmutation of radioactive waste will be most effective are analyzed too. The modeling results of a transmutation of the main radioactive isotopes are presented and discussed. The transmutation of minor actinides and long-lived fission products are modeled in our work (minor actinides - Np-237, Am-241, Am-242, Am-243, Cm-244, Cm-245; long-lived fission products - I-129, Tc-99). The two-zone subcritical system is calculated with help of different neutron-physical codes (MCNP, Scale, Montebarn, Origen). The ENDF/B-VI nuclear data library used in above calculations. Thus, radioactive wastes can be divided into two main groups that need to be transmuted. The minor actinides form the first group and the long-lived fission products form the second one. For the purpose of effective transmutation these isotopes must be extracted from the spent nuclear fuel with the help of either PUREX technology or pyrometallurgical technology. The two-zone reactor system with fast and thermal regions is more effective for nuclear waste transmutation than the one-zone reactor. Modeling results show that nearly all radioactive wastes can be transmuted in the two-zone subcritical system driven by a high-intensity neutron generator with the external neutron source strength of 1.10{sup 13} n/sec. Obviously, transmutation rate will increase with a rise of the external neutron source strength. From the results above we can also see that the initial loading of radioactive isotopes into the reactor system should exceed by mass those isotopes that are finally produced. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Improved Energy Deposition Model in MPACT and Explicit Heat Generation Coupling with CTF

The default energy deposition model in the CASL neutronics code MPACT assumes all fission energy is deposited locally in fuel rods. Furthermore, equilibrium delayed energy release is assumed for both steady-state and transient calculations. These approximations limit the accurate representation of the heat generation distribution in space and its variations over time, which are essential for power distribution and thermal-hydraulic coupling calculations. In this paper, an improved energy deposition model is presented in both the spatial and time domains. Spatially, the energy deposition through fission, neutron capture, and slowing-down reactions are explicitly modeled to account for the heat generation from all regions of a reactor core, and a gamma smearing scheme is developed that utilizes the gamma sources from neutron fission and capture. In the time domain, the delayed energy release is modeled by solving an additional equation of delayed heat emitters, similar to the equation of delayed neutron precursors.To allow the explicit heat generation coupling, the interfaces between MPACT and CTF were updated to transfer separate heat sources for different material regions (fuel, clad, moderator and guide tube). The results show that the distributions of the energy deposition between MPACT and MCNP agree very well for various 2-D assembly and quarter-core problems without TH feedback. The MPACT/CTF coupled calculation for the hot full power quarter-core case exhibited a reduced peak pin power by 2.3% and a reduced peak fuel centerline temperature by 17 K when using the explicit energy deposition and heat transfer. The new model also shows a maximum 100 pcm keff effect on assembly depletion problems and an increased overall energy release by 7% in a PWR reactivity-initiated accident (RIA) problem.

Liu, Yuxuan↗

GAMMA DOSE RATE NEAR A NEW (252)Cf BRACHYTHERAPY SOURCE

A new generation of medical grade (252)Cf sources was developed in 2002 at the Oak Ridge National Laboratory. The combination of small size and large activity of (252)Cf makes the new source suitable to be used with the conventional high-dose-rate remote afterloading system for interstitial brachytherapy. A recent in-water calibration experiment showed that the measured gamma dose rates near the new source are slightly greater than the neutron dose rates, contradicting the well established neutron-to-gamma dose ratio of approximately 2:1 at locations near a (252)Cf brachytherapy source. Specifically, the MCNP-predicted gamma dose rate is a factor of two lower than the measured gamma dose rate at the distance of I cm, and the differences between the two results gradually diminish at distances farther away from the source. To resolve this discrepancy, we updated the source gamma spectrum by including in the ORIGEN-S data library the experimentally measured (252)Cf prompt gamma spectrum as well as the true (252)Cf spontaneous fission yield data to explicitly model delayed gamma emissions from fission products. We also investigated the bremsstrahlung X-rays produced by the beta particles emitted from fission product decays. The results show that the discrepancy of gamma dose rates is mainly caused by the omission of the bremsstrahlung X-rays in the MCNP runs. By including the bremsstrahlung X-rays, the MCNP results show that the gamma dose rates near a new (252)Cf source agree well with the measured results and that the gamma dose rates are indeed greater than the neutron dose rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methodology comparison for gamma-heating calculations in material-testing reactors

The Jules Horowitz Reactor (JHR) is a Material-Testing Reactor (MTR) under construction in the south of France at CEA Cadarache (French Alternative Energies and Atomic Energy Commission). It will typically host about 20 simultaneous irradiation experiments in the core and in the beryllium reflector. These experiments will help us better understand the complex phenomena occurring during the accelerated ageing of materials and the irradiation of nuclear fuels. Gamma heating, i.e. photon energy deposition, is mainly responsible for temperature rise in non-fuelled zones of nuclear reactors, including JHR internal structures and irradiation devices. As temperature is a key parameter for physical models describing the behavior of material, accurate control of temperature, and hence gamma heating, is required in irradiation devices and samples in order to perform an advanced suitable analysis of future experimental results. From a broader point of view, JHR global attractiveness as a MTR depends on its ability to monitor experimental parameters with high accuracy, including gamma heating. Strict control of temperature levels is also necessary in terms of safety. As JHR structures are warmed up by gamma heating, they must be appropriately cooled down to prevent creep deformation or melting. Cooling-power sizing is based on calculated levels of gamma heating in the JHR. Due to these safety concerns, accurate calculation of gamma heating with well-controlled bias and associated uncertainty as low as possible is all the more important. There are two main kinds of calculation bias: bias coming from nuclear data on the one hand and bias coming from physical approximations assumed by computer codes and by general calculation route on the other hand. The former must be determined by comparison between calculation and experimental data; the latter by calculation comparisons between codes and between methodologies. In this presentation, we focus on this latter kind of bias. Nuclear heating is represented by the physical quantity called absorbed dose (energy deposition induced by particle-matter interactions, divided by mass). Its calculation with Monte Carlo codes is possible but computationally expensive as it requires transport simulation of charged particles, along with neutrons and photons. For that reason, the calculation of another physical quantity, called KERMA, is often preferred, as KERMA calculation with Monte Carlo codes only requires transport of neutral particles. However, KERMA is only an estimator of the absorbed dose and many conditions must be fulfilled for KERMA to be equal to absorbed dose, including so-called condition of electronic equilibrium. Also, Monte Carlo computations of absorbed dose still present some physical approximations, even though there is only a limited number of them. Some of these approximations are linked to the way how Monte Carlo codes apprehend the transport simulation of charged particles and the productive and destructive interactions between photons, electrons and positrons. There exists a huge variety of electromagnetic shower models which tackle this topic. Differences in the implementation of these models can lead to discrepancies in calculated values of absorbed dose between different Monte Carlo codes. The magnitude of order of such potential discrepancies should be quantified for JHR gamma-heating calculations. We consequently present a two-pronged plan. In a first phase, we intend to perform compared absorbed dose / KERMA Monte Carlo calculations in the JHR. This way, we will study the presence or absence of electronic equilibrium in the different JHR structures and experimental devices and we will give recommendations for the choice of KERMA or absorbed dose when calculating gamma heating in the JHR. In a second phase, we intend to perform compared TRIPOLI4 / MCNP absorbed dose calculations in a simplified JHR-representative geometry. For this comparison, we will use the same nuclear data library for both codes (the European library JEFF3.1.1 and photon library EPDL97) so as to isolate the effects from electromagnetic shower models on absorbed dose calculation. This way, we hope to get insightful feedback on these models and their implementation in Monte Carlo codes. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

General Handling Calculations for the Modified Hospital Can

Containers are evaluated using a Monte-Carlo N-Particle transport code (MCNP). The code calculated keff is compared to critical experiment benchmarks to determine a bias. Additional margin of safety is added to the bias to establish an upper subcritical limit (USL). Modeled cases are considered subcritical if the neutron multiplication factor plus two sigma remains below the USL. Net weight limits allow for any amount of fissile/moderator mixture to exist so long as it meets the weight requirement, therefore all mixture types must be evaluated. Cases that exceed the USL must either be controlled against or have justification why that configuration cannot reasonably exist. Current and legacy loadings and container dimensions must be taken into consideration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity studies to Support TEX critical experiments design

In the frame of the ongoing Thermal/Epithermal experiments program, supported by the DOE-NCSP, we are characterizing expected data with analysis of sensitivity coefficients to nuclear data. The computations were performed for detailed and simplified models of the experimental configurations in order to demonstrate their invariance with respect to small geometry variations. The sensitivity coefficients were computed with recently developed precise methodologies using Monte Carlo tools (MCNP-6.1, SCALE 6.1 and MORET 5.C.1) with the following nuclear data libraries: ENDF/B-VII.0, ENDF/B-VII.1, and JEFF3.1. Since the considered experiments are devoted to tantalum data validation, their neutronic characteristics are compared with the relevant integral experiment data collected in the OECD/NEA ICSBEP Handbook. Although analysis of sensitivity coefficients taken alone is insufficient for an entire assessment, we can conclude that TEX experimental results can fill gaps in the available benchmarks to facilitate quantification of uncertainty for plutonium containing systems with epithermal neutron spectra (e.g. wet plutonium-based powders). However, analysis of sensitivity profiles demonstrates that an advanced statistical methodology will be needed to fit tantalum nuclear data or to evaluate the associated uncertainties. (authors)

42 ENGINEERING↗

MONTE-CARLO BURNUP CALCULATION UNCERTAINTY QUANTIFICATION AND PROPAGATION DETERMINATION

MONTEBURNS is a Monte-Carlo depletion routine utilizing MCNP and ORIGEN 2.2. Uncertainties exist in the MCNP transport calculation, but this information is not passed to the depletion calculation in ORIGEN or saved. To quantify this transport uncertainty and determine how it propagates between burnup steps, a statistical analysis of a multiple repeated depletion runs is performed. The reactor model chosen is the Oak Ridge Research Reactor (ORR) in a single assembly, infinite lattice configuration. This model was burned for a 25.5 day cycle broken down into three steps. The output isotopics as well as effective multiplication factor (k-effective) were tabulated and histograms were created at each burnup step using the Scott Method to determine the bin width. It was expected that the gram quantities and k-effective histograms would produce normally distributed results since they were produced from a Monte-Carlo routine, but some of results do not. The standard deviation at each burnup step was consistent between fission product isotopes as expected, while the uranium isotopes created some unique results. The variation in the quantity of uranium was small enough that, from the reaction rate MCNP tally, round off error occurred producing a set of repeated results with slight variation. Statistical analyses were performed using the {chi}{sup 2} test against a normal distribution for several isotopes and the k-effective results. While the isotopes failed to reject the null hypothesis of being normally distributed, the {chi}{sup 2} statistic grew through the steps in the k-effective test. The null hypothesis was rejected in the later steps. These results suggest, for a high accuracy solution, MCNP cell material quantities less than 100 grams and greater kcode parameters are needed to minimize uncertainty propagation and minimize round off effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗