Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Flight Readiness of Mochii S: Portable Spectroscopic Scanning Electron Microscope Facility on the International Space Station (ISS)

The ISS (International Space Station) currently lacks the capability to image and chemically analyze nano-to-micron scale particles from numerous engineering systems. To identify these particles, we must wait for a re-entry vehicle to return them from low earth orbit for ground-based SEM (Scanning Electron Microscope) / EDS (Energy Dispersive X-Ray Spectroscopy) analysis. This may take months, potentially delaying the affected system. Having an EDS-equipped SEM (Mochii S) aboard the ISS will accelerate response time thereby enhancing crew and vehicle safety by rapid and accurate identification of microscopic threats, especially in time-critical situations.The Mochii S payload will be stationed in the Japanese Experiment Module (JEM) powered by 120 VAC (Volts Alternating Current) inverter and connected to station Ethernet and WiFi (Fig. 1). To date the Mochii S payload has undergone testing for command and data handling, power quality, flight vibration, and radiation testing at Johnson Space Center (JSC). Mochii's high-RPM (Revolutions Per Minute) rotating vacuum pumps and high voltage systems have been reviewed to meet safety standards by JSC (Johnson Space Center) Engineering. Topology of the system in the JEM module has been baselined by ISS Safety and JAXA (Japan Space Exploration Agency). Digital controls to and from ISS over Joint Station LAN (Local Area Network) uplink have been simulated and the latencies and data rates have been found to be sufficient for successful operation of the payload from ground.Transporting sensitive electron optical instruments aboard a rocket that sustains 7G acceleration for 8 minutes and then operating it the unique microgravity (micro-g) environment is no trivial matter. To meet strict safety requirements and increase robustness for mission success, over 500 unique verifications must be completed before the payload is certified for spaceflight. Two of which will be discussed in detail are: vibroacoustic testing and magnetic susceptibility shielding and validation.

Mochii↗

Flight Readiness of Mochii ISS-NL Portable Spectroscopic Electron Microscope

Electron microscopes (EM’s), are workhorse tools serving diverse fields such as materials science, biological science, and engineering. Scanning EM’s (SEM’s) in particular enable high magnification study and pinpoint chemical analyses of structures down to the nanoscale by providing a powerful blend of strong optical scattering, high native resolution, large depth of focus, and energy-dispersive X-ray spectroscopy (EDS). Mochii is the world’s smallest production electron microscope, scheduled to travel to the International Space Station (ISS) this spring where it will serve as an ISS National Laboratory (ISSNL) microgravity facility on successful demonstration. We previously reported on progress preparing Mochii for space flight, in particular flight integration verifications and science application testing. These included standard integration testing such as electromagnetic interference and flight vibration, and extend to unique functional testing such as magnetic susceptibility and extreme analog environment testing under the sea. Presently, Mochii payload flight hardware has completed testing and was handed over to NASA’s ISS payload processing facility in Houston. It will make its way to the the east coast for launch currently scheduled on Space-X CRS-20 for Mission increment 62 in March 2020.

Own, C. S.↗

Advancing Launch Readiness of the Europa Light Microscope

The search for life in our solar system relies on our ability to measure key biomarkers in situ and identify them as likely of biotic origin. One class of biomarkers that would be indicative of life is cell-like features such as the colocalization of key biochemicals, spatial organization of native UV fluorescent compounds, and polarization across membrane compartments. The Europa Lander Science Definition Team has emphasized the need for a light microscope to search for these features on Europa, and the Europa Light Microscope (ELM) has been developed to address this need. This work presents the development towards high launch readiness of ELM by demonstrating its optical resolution under brightfield illumination, deep UV fluorescence imaging of unstained living samples, and multicolor imaging of samples stained with exogenous fluorophores targeting proteins, lipids, and nucleic acids. This work also seeks to extend the capabilities of ELM by incorporating fluorescence-based assays for membrane potential as a key biomarker for living cellular material.

Pavel Erich Zivanovic Klier↗

Macroscopic observables experimentally linked to microscopic processes in the explosive fracture and fragmentation of metals

The response of a metal element to explosive loading depends on a broad spectrum of explosive and metal properties, macroscopic geometry plays a crucial role in defining the localized loading history and the resulting gradients of interest, while microscopic effects and defects are generally believed responsible for damage nucleation. Certain experiments reduce the complexity by producing conditions that are uniform in some sense, allowing dynamic measurement of variables that can be correlated with corresponding microscopic effects observed in recovery experiments. Spherical expansion of thin shells, that eventually fragment, and steady wave loading of flat plates are two such experiments. Proton radiography, x-radiography, laser velocimetry, imaging IR, and visible light photography all have produced dynamic measurements in 4340 steel, copper, uranium alloys, tantalum, and titanium. Correlation of the macroscopic measurements with microscopy on recovered samples has been done with a statistical approach.

36 MATERIALS SCIENCE↗

Scanning tunneling microscope assembly, reactor, and system

An embodiment of a scanning tunneling microscope (STM) reactor includes a pressure vessel, an STM assembly, and three spring coupling objects. The pressure vessel includes a sealable port, an interior, and an exterior. An embodiment of an STM system includes a vacuum chamber, an STM reactor, and three springs. The three springs couple the STM reactor to the vacuum chamber and are operable to suspend the scanning tunneling microscope reactor within the interior of the vacuum chamber during operation of the STM reactor. An embodiment of an STM assembly includes a coarse displacement arrangement, a piezoelectric fine displacement scanning tube coupled to the coarse displacement arrangement, and a receiver. The piezoelectric fine displacement scanning tube is coupled to the coarse displacement arrangement. The receiver is coupled to the piezoelectric scanning tube and is operable to receive a tip holder, and the tip holder is operable to receive a tip.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electron microscope phase enhancement

A microfabricated electron phase shift element is used for modifying the phase characteristics of an electron beam passing though its center aperture, while not affecting the more divergent portion of an incident beam to selectively provide a ninety-degree phase shift to the unscattered beam in the back focal plan of the objective lens, in order to realize Zernike-type, in-focus phase contrast in an electron microscope. One application of the element is to increase the contrast of an electron microscope for viewing weakly scattering samples while in focus. Typical weakly scattering samples include biological samples such as macromolecules, or perhaps cells. Preliminary experimental images demonstrate that these devices do apply a ninety degree phase shift as expected. Electrostatic calculations have been used to determine that fringing fields in the region of the scattered electron beams will cause a negligible phase shift as long as the ratio of electrode length to the transverse feature-size aperture is about 5:1. Calculations are underway to determine the feasibility of aspect smaller aspect ratios of about 3:1 and about 2:1.

47 OTHER INSTRUMENTATION↗

Scientists View Battery Under Microscope

PNNL researchers use a special microscope setup that shows the inside of a battery as it charges and discharges. This battery-watching microscope is located at EMSL, DOE's Environmental Molecular Sciences Laboratory that resides at PNNL. Researchers the world over can visit EMSL and use special instruments like this, many of which are the only one of their kind available to scientists.

25 ENERGY STORAGE↗

Polarized pulsed front-end beam source for electron microscope

A method and an electron source are provided for generating polarized electrons for an electron microscope. The electron source includes a photoemissive cathode and a low-power drive laser. The geometry of the photoemissive cathode uses a generally planar emission surface, which is imaged to approximately 1/100 its initial size via electrostatic focusing elements. The virtual emitter, or image spot, then is used as an electron source by a conventional microscope column.

Lewellen, John W.↗

High content screening workflows for microscope imaging

Disclosed herein are systems methods for high content screening for microscope imaging. In some embodiments, the system comprises: a microscope; and a processor configured to implement: a slide loader module; a reference imager module; a slide imager module; a region of interest (ROI) finder module; a compare imager module; a calibrator module; and an image stitcher module.

42 ENGINEERING↗

Electron Microscopic Examination of an Irradiated TRISO Coated Particle of AGR-2 Experiment: AGR2-222-RS019

The transmission electron microscopic (TEM) examination of an irradiated tristructural isotropic (TRISO) coated particle from advanced gas reactor (AGR) 2 fuel Compact 2-2-2 is presented in this report. Compact 2-2-2 refers to the compact in Capsule 2 at Level 2 of Stack 2. The examination on AGR2 222 RS019 is focused on the interface between the silicon carbide (SiC) to inner pyrolytic carbon (IPyC) layer, central part of SiC, and the interface between SiC and outer pyrolytic carbon layer. The SiC grain boundary distribution and associated fission product precipitates were characterized by scanning transmission electron microscopy (STEM) energy dispersive spectroscopy (EDS), and precession electron diffraction (PED) in the transmission electron microscope. Two separate locations on SiC layer were selected for on the basis of the intact of the buffer layer in the irradiated TRISO particle. The key observation in this particle is that the compositional nature of grain boundary precipitates is more complex near IPyC/SiC layer where Pd, Pd-Ag, Pd-U containing precipitates can be observed. However, the compositions of precipitate towards outer most region of SiC mainly contain Pd. Ag has been observed in the IPyC/SiC layer in one of the two locations. Comparison of the results to previously irradiated and analyzed, Variant 3, safety tested AGR-1 TRISO particles (AGR1-433-001 and AGR1 222-RS004) showed the grain boundary distributions have some noticeable differences. The differences in coincident site lattice grain boundary and misorientation angles are possibly inherent to the fabrication process. Neutron irradiation induced void distribution has been found to be nonuniform. A high concentration of smaller voids is found at stacking faults compared to those in the SiC matrix. Larger void sizes are observed in the SiC location that is near to the broken buffer layer. This void size variation with integrity of buffer layer can potentially affect the fission product retention. However, the average void size continuously decreases along the radius of SiC in both locations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated transmission electron microscope

An integrated transmission electron microscope comprising multiple electron sources for tuned beams of ultrafast, scanning probe, and parallel illumination in varied beam energies can be alternated within sub-microseconds onto a sample with dynamic ‘transient state’ processes to acquire atomic-scale structural/chemical data with site specificity. The various electron sources and condenser optics enable high-resolution imaging, high-temporal resolution imaging, and chemical imaging, using fast-switching magnets to direct the different electron beams onto a single maneuverable objective pole piece where the sample resides. Such multimodal in situ characterization tools housed in a single microscope have the potential to revolutionize materials science.

Jungjohann, Katherine L.↗

Ion and electron beam nanofabrication of the which-way double-slit experiment in a transmission electron microscope

We have realized a which-way experiment closely resembling the original Feynman's proposal exploiting focused ion beam milling to prepare two nanoslits and electron beam induced deposition to grow, selectively over one of them, electron transparent layers of low atomic number amorphous material to realize a which-way detector for high energy electrons. By carrying out the experiment in an electron microscope equipped with an energy filter, we show that the inelastic scattering of electron transmitted through amorphous layers of different thicknesses provides the control of the dissipative interaction process responsible for the localization phenomena which cancels out the interference effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Scanning Electron Microscope As An Accelerator For The Undergraduate Advanced Physics Laboratory

Few universities or colleges have an accelerator for use with advanced physics laboratories, but many of these institutions have a scanning electron microscope (SEM) on site, often in the biology department. As an accelerator for the undergraduate, advanced physics laboratory, the SEM is an excellent substitute for an ion accelerator. Although there are no nuclear physics experiments that can be performed with a typical 30 kV SEM, there is an opportunity for experimental work on accelerator physics, atomic physics, electron-solid interactions, and the basics of modern e-beam lithography.

99 GENERAL AND MISCELLANEOUS↗

Mechanisms Underlying a Quantum Superposition Microscope Based on THz-Driven Coherent Oscillations in a Two-Level Molecular Sensor

Here we report pump-probe measurements of a hydrogen molecule (H 2 ) in the tunnel junction of a scanning tunneling microscope (STM) coupled to ultrashort terahertz (THz) pulses. The coherent oscillation of the THz induced DC tunneling current at a frequency of ~0.5 THz fingerprints the absorption by H 2 as a two-level system (TLS). Two components of the oscillatory signal are observed and point to both photon and field aspects of the THz pulses. A few loosely bound states with similar energies for the upper state of the TLS are evidenced by the coherent revival of oscillatory signal. Furthermore, the comparison of spectroscopic features of H 2 with different tips provides an understanding of the TLS for H 2 .

36 MATERIALS SCIENCE↗

Quantifying and visualizing the microscopic degrees of freedom of grain boundaries in the Wigner–Seitz cell of the displacement-shift-complete lattice

Here we introduce a grain boundary (GB) translation vector, t ws , to describe and quantify the domain of the microscopic degrees of freedom of GBs. It has long been recognized that for fixed macroscopic degrees of freedom of a GB there exists a large multiplicity of states characterized by different relative grain translations. More recently another degree of freedom, [n], the number of GB atoms, has emerged and is now recognized as an equally important component of GB structural multiplicity. In this work, we show that all GB microstates can be uniquely characterized by their value of t ws , which is located within the Wigner–Seitz (WS) cell of the Displacement-Shift-Complete lattice (DSCL) of the GB. The GB translation vector captures information about both the translation state and the number of GB atoms. We show that the density of GB microstates inside the WS cell of the DSCL is not uniform and can form clusters that correspond to different GB phases. Further, the vectors connecting the centers of the clusters correspond to the Burgers vectors of GB phase junctions, which can be predicted without building the junctions. Using t ws , we quantify GB excess shear and argue that it is defined up to a DSCL vector, which has implications for thermodynamic equilibrium conditions. Additionally, this work generalizes the definition of the number of GB atoms [n] to asymmetric boundaries.

36 MATERIALS SCIENCE↗

Measurement of the unstained biological sample by a novel scanning electron generation X-ray microscope based on SEM

We introduced a novel X-ray microscope system based on scanning electron microscopy using thin film, which enables the measurement of unstained biological samples without damage. An unstained yeast sample was adsorbed under a titanium (Ti)-coated silicon nitride (Si{sub 3}N{sub 4}) film 90 nm thick. The X-ray signal from the film was detected by an X-ray photodiode (PD) placed below the sample. With an electron beam at 2.6 kV acceleration and 6.75 nA current, the yeast image is obtained using the X-ray PD. The image is created by soft X-rays from the Ti layer. The Ti layer is effective in generating the characteristic 2.7-nm wavelength X-rays by the irradiation of electrons. Furthermore, we investigated the electron trajectory and the generation of the characteristic X-rays within the Ti-coated Si{sub 3}N{sub 4} film by Monte Carlo simulation. Our system can be easily utilized to observe various unstained biological samples of cells, bacteria, and viruses.

60 APPLIED LIFE SCIENCES↗

Electron microscopic evidence for the myosin head lever arm mechanism in hydrated myosin filaments using the gas environmental chamber

Research highlights: {yields} We succeeded in recording structural changes of hydrated myosin cross-bridges. {yields} We succeeded in position-marking the cross-bridges with site-directed antibodies. {yields} We recorded cross-bridge movement at different regions in individual cross-bridge. {yields} The movement was smallest at the cross-bridge-subfragment two boundary. {yields} The results provide evidence for the cross-bridge lever arm mechanism. -- Abstract: Muscle contraction results from an attachment-detachment cycle between the myosin heads extending from myosin filaments and the sites on actin filaments. The myosin head first attaches to actin together with the products of ATP hydrolysis, performs a power stroke associated with release of hydrolysis products, and detaches from actin upon binding with new ATP. The detached myosin head then hydrolyses ATP, and performs a recovery stroke to restore its initial position. The strokes have been suggested to result from rotation of the lever arm domain around the converter domain, while the catalytic domain remains rigid. To ascertain the validity of the lever arm hypothesis in muscle, we recorded ATP-induced movement at different regions within individual myosin heads in hydrated myosin filaments, using the gas environmental chamber attached to the electron microscope. The myosin head were position-marked with gold particles using three different site-directed antibodies. The amplitude of ATP-induced movement at the actin binding site in the catalytic domain was similar to that at the boundary between the catalytic and converter domains, but was definitely larger than that at the regulatory light chain in the lever arm domain. These results are consistent with the myosin head lever arm mechanism in muscle contraction if some assumptions are made.

60 APPLIED LIFE SCIENCES↗