Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROSCOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Electroluminescence Imaging: A Study in the Impact of Microscopic Surface Defects

Electroluminescence (EL) imaging can be used as a quantitative characterization method for solar cell performance when combined with image processing, allowing for the impact of dust grain size on electroluminescence imaging characteristics to be investigated. Simulating these results via modelling can help to predict what dust grain sizes, if any, will have a greater impact on performance.

photovoltaics↗

Preliminary Examination of Returned Samples From Bennu Using Quantitative Particle Analysis in the Scanning Electron Microscope

The sample of regolith collected from asteroid Bennu by NASA’s OSIRIS-REx spacecraft will land in Utah on September 24, 2023. A 100-mg aliquot of fine Bennu dust adhering to the internal surfaces of the sample return capsule and associated hardware will be collected by curation staff during disassembly and analyzed immediately by members of the sample analysis team in a “Quick-Look” (Q-L) procedure. The Q-L objectives are (1) to provide images for release to the public to inform on the nature of the returned sample, and (2) to perform a reconnaissance investigation of the mineralogic characteristics of the returned material for science purposes. We will determine the minerals that occur in the dust, assess their diversity, and determine relative abundances at the >5% level using a combination of optical microscopy, Fourier-transform infrared spectroscopy, X-ray powder diffraction, and field-emission scanning electron microscopy (SEM). Here we describe the procedures and techniques developed for the Q-L analyses using analog samples analyzed by SEM equipped with energy dispersive X-ray spectroscopy (EDX). To test these techniques, we have applied them to several samples, including powders of the Murchison (Fig. 1) and Orgueil meteorites, as well as simulant samples prepared by the mission.

OSIRIS-REx↗

Small Particle Glovebox Experiments - Preliminary Results

A substantial portion of the asteroid samples returned by the HAYABUSA2 and OSIRIS-REx missions will consist of small (submm) components (due to the collection of those particles on the asteroid surface and due to the fragmenting of larger, friable material post-collection). In order to minimize the alteration/oxidation of asteroid regolith, the bulk collections will be stored and curated in nitrogen purged gloveboxes. The processing of small particles in an N2 glovebox will present challenges that are different from those experienced during lunar and meteorite sample processing. Particles in this size range are susceptible to unpredictable electrostatic charging that can result in sample loss during processing operations. Methods for the handling of sub-mm particles have been well developed for environments with ambient atmospheric conditions and relative humidity (RH) ranges between 40-70%. In such conditions, a number of factors can be successfully employed to minimize the effects of triboelectric charging, including the use of Po-210 sources that neutralize excess charge and the utilization of conductive manipulation tools and sample substrates. However, relative humidity levels above 40% also contribute significantly to dissipation of triboelectric effects. We had not previously investigated our charge mitigation methods in a completely dry, nitrogen-purged environment, or whether they would be sufficient in enabling the successful processing of sub-mm samples. Current glovebox configurations in use in our lunar and meteorite curation laboratories are optimized for the processing of macroscopic samples and tools; these glovebox designs are likely unsuitable for the processing of collections for which the bulk collection is comprised of sub-mm components. Small particle sample preparation requires the use of an optical magnification instrument – typically a stereo binocular microscope with at least 20x magnification. Current glovebox designs are not optimized for the utilization or integration of stereo microscopes; while many current cabinets include microscope viewports that enable the use of small, externally mounted stereo microscopes, the focusing methods (usually involving the use of a lab jack) lack the fidelity and precision required for small particle manipulation and imaging. Working distances of higher (>50x magnification) objective lenses may preclude the external use of a stereo microscope through a viewport; in order to successfully manipulate and image very small (< 20m) particles, stereo and digital microscope systems that are integrated within the glovebox should be investigated. Finally, ergonomic considerations for small particle work within a glovebox must be considered to minimize risk of injury to sample processors. In order to investigate some of the unknown parameters relating to small particle processing within an N2 glovebox, we conducted preliminary, qualitative experiments utilizing a small lunar cabinet that was originally used for film development.

C. J. Snead↗

Lagrangian description of warm plasmas

Efforts are described to extend the averaged Lagrangian method of describing small signal wave propagation and nonlinear wave interaction, developed by earlier workers for cold plasmas, to the more general conditions of warm collisionless plasmas, and to demonstrate particularly the effectiveness of the method in analyzing wave-wave interactions. The theory is developed for both the microscopic description and the hydrodynamic approximation to plasma behavior. First, a microscopic Lagrangian is formulated rigorously, and expanded in terms of perturbations about equilibrium. Two methods are then described for deriving a hydrodynamic Lagrangian. In the first of these, the Lagrangian is obtained by velocity integration of the exact microscopic Lagrangian. In the second, the expanded hydrodynamic Lagrangian is obtained directly from the expanded microscopic Lagrangian. As applications of the microscopic Lagrangian, the small-signal dispersion relations and the coupled mode equations are derived for all possible waves in a warm infinite, weakly inhomogeneous magnetoplasma, and their interactions are examined.

Kim, H.↗

Particle nonuniformity effects on particle cloud flames in low gravity

Experimental and analytical studies of particle cloud combustion at reduced gravity reveal the substantial roles that particle cloud nonuniformities may play in particle cloud combustion. Macroscopically uniform, quiescent particle cloud systems (at very low gravitational levels and above) sustain processes which can render them nonuniform on both macroscopic and microscopic scales. It is found that a given macroscopically uniform, quiescent particle cloud flame system can display a range of microscopically nonuniform features which lead to a range of combustion features. Microscopically nonuniform particle cloud distributions are difficult experimentally to detect and characterize. A uniformly distributed lycopodium cloud of particle-enriched microscopic nonuniformities in reduced gravity displays a range of burning velocities for any given overall stoichiometry. The range of observed and calculated burning velocities corresponds to the range of particle enriched concentrations within a characteristic microscopic nonuniformity. Sedimentation effects (even in reduced gravity) are also examined.

Berlad, A. L.↗

Handheld White Light Interferometer for Measuring Defect Depth in Windows

Accurate quantification of defects (scratches and impacts) is vital to the certification of flight hardware and other critical components. The amount of damage to a particular component contributes to the performance, reliability, and safety of a system, which ultimately affects the success or failure of a mission or test. The launch-commit criteria on a Space Shuttle Orbiter window are governed by the depth of the defects that are identified by a visual inspection. This measurement of a defect is not easy to obtain given the environment, size of the defect, and location of the window(s). The determination of depth has typically been performed by taking a mold impression and measuring the impression with an optical profiling instrument. Another method of obtaining an estimate of the depth is by using a refocus microscope. To use a refocus microscope, the surface of the glass and bottom of the defect are, in turn, brought into focus by the operator. The amount of movement between the two points corresponds to the depth of the defect. The refocus microscope requires a skilled operator and has been proven to be unreliable when used on Orbiter windows. White light interferometry was chosen as a candidate to replace the refocus microscope. The White Light Interferometer (WLI) was developed to replace the refocus microscope as the instrument used for measuring the depth of defects in Orbiter windows. The WLI consists of a broadband illumination source, interferometer, detector, motion control, displacement sensor, mechanical housing, and support electronics. The illumination source for the WLI is typically a visible light emitting diode (LED) or a near-infrared superluminescent diode (SLD) with power levels of less than a milliwatt. The interferometer is a Michelson configuration consisting of a 1-in. (2.5-cm) cube beam splitter, a 0.5-in. (1.3-cm) optical window as a movable leg (used to closely match the return intensity of the fixed leg from the window), and a mirrored prism to fold the optics into the mechanical housing. The detector may be one of many C-mount CCD (charge-coupled device) cameras. Motion is provided by a commercial nanostepping motor with a serial interface. The displacement sensor is a custom device specifically designed for this application. The mechanical housing and support electronics were designed to integrate the various components into an instrument that could be physically handled by a technician and easily transported.

Youngquist, Robert↗

Method for nanoscale spatial registration of scanning probes with substrates and surfaces

Embodiments in accordance with the present invention relate to methods and apparatuses for aligning a scanning probe used to pattern a substrate, by comparing the position of the probe to a reference location or spot on the substrate. A first light beam is focused on a surface of the substrate as a spatial reference point. A second light beam then illuminates the scanning probe being used for patterning. An optical microscope images both the focused light beam, and a diffraction pattern, shadow, or light backscattered by the illuminated scanning probe tip of a scanning probe microscope (SPM), which is typically the tip of the scanning probe on an atomic force microscope (AFM). Alignment of the scanning probe tip relative to the mark is then determined by visual observation of the microscope image. This alignment process may be repeated to allow for modification or changing of the scanning probe microscope tip.

Wade, Lawrence A.↗

Aligning Arrays of Lenses and Single-Mode Optical Fibers

A procedure now under development is intended to enable the precise alignment of sheet arrays of microscopic lenses with the end faces of a coherent bundle of as many as 1,000 single-mode optical fibers packed closely in a regular array (see Figure 1). In the original application that prompted this development, the precise assembly of lenses and optical fibers serves as a single-mode spatial filter for a visible-light nulling interferometer. The precision of alignment must be sufficient to limit any remaining wavefront error to a root-mean-square value of less than 1/10 of a wavelength of light. This wavefront-error limit translates to requirements to (1) ensure uniformity of both the lens and fiber arrays, (2) ensure that the lateral distance from the central axis of each lens and the corresponding optical fiber is no more than a fraction of a micron, (3) angularly align the lens-sheet planes and the fiber-bundle end faces to within a few arc seconds, and (4) axially align the lenses and the fiber-bundle end faces to within tens of microns of the focal distance. Figure 2 depicts the apparatus used in the alignment procedure. The beam of light from a Zygo (or equivalent) interferometer is first compressed by a ratio of 20:1 so that upon its return to the interferometer, the beam will be magnified enough to enable measurement of wavefront quality. The apparatus includes relay lenses that enable imaging of the arrays of microscopic lenses in a charge-coupled-device (CCD) camera that is part of the interferometer. One of the arrays of microscopic lenses is mounted on a 6-axis stage, in proximity to the front face of the bundle of optical fibers. The bundle is mounted on a separate stage. A mirror is attached to the back face of the bundle of optical fibers for retroreflection of light. When a microscopic lens and a fiber are aligned with each other, the affected portion of the light is reflected back by the mirror, recollimated by the microscopic lens, transmitted through the relay lenses and the beam compressor/expander, then split so that half goes to a detector and half to the interferometer. The output of the detector is used as a feedback control signal for the six-axis stage to effect alignment.

Liu, Duncan↗

Effect of double layers on magnetosphere-ionosphere coupling

The Earth's auroral zone contains dynamic processes occurring on scales from the length of an auroral zone field line which characterizes Alfven wave propagation to the scale of microscopic processes which occur over a few Debye lengths. These processes interact in a time-dependent fashion since the current carried by the Alfven waves can excite microscopic turbulence which can in turn provide dissipation of the Alfven wave energy. This review will first describe the dynamic aspects of auroral current structures with emphasis on consequences for models of microscopic turbulence. A number of models of microscopic turbulence will be introduced into a large-scale model of Alfven wave propagation to determine the effect of various models on the overall structure of auroral currents. In particular, the effects of a double layer electric field which scales with the plasma temperature and Debye length is compared with the effect of anomalous resistivity due to electrostatic ion cyclotron turbulence in which the electric field scales with the magnetic field strength. It is found that the double layer model is less diffusive than in the resistive model leading to the possibility of narrow, intense current structures.

Lysak, Robert L.↗

Crystal growth of compound semiconductors in a low-gravity environment (InGaAs crystals) (M-22)

Compound semiconductor crystals, such as gallium arsenide and indium phosphide crystals, have many interesting properties that silicon crystals lack, and they are expected to be used as materials for optic and/or electro-optic integrated devices. Generally speaking, alloy semiconductors, which consist of more than three elements, demonstrate new functions. For example, values of important parameters, such as lattice constant and emission wavelength, can be chosen independently. However, as it is easy for macroscopic and/or microscopic fluctuations of composition to occur in alloy semiconductor crystals, it is difficult to obtain crystals having homogeneous properties. Macroscopic change of composition in a crystal is caused by the segregation phenomenon. This phenomenon is due to a continuous change in the concentration of constituent elements at the solid-liquid interfacing during solidification. On Earth, attempts were made to obtain a crystal with homogeneous composition by maintaining a constant melt composition near the solid-liquid interface, through suppression of the convection flow of the melt by applying a magnetic field. However, the attempt was not completely successful. Convective flow does not occur in microgravity because the gravity in space is from four to six orders of magnitude less than that on Earth. In such a case, mass transfer in the melt is dominated by the diffusion phenomenon. So, if crystal growth is carried out at a rate that is higher than the rate of mass transfer due to this phenomenon, it is expected that crystals having a homogeneous composition will be obtained. In addition, it is also possible that microscopic composition fluctuations (striation) may disappear because microscopic fluctuations diminish in the absence of convection. We are going to grow a bulk-indium gallium arsenide (InGaAs) crystal using the gradient heating furnace (GHF) in the first material processing test (FMPT). The structure of the sample is shown where InGaAs polycrystals in a crucible are doubly sealed in two quartz tubes for safety. The GHF consists of two zones, namely, high temperature and low temperature zones, which results in a large temperature gradient at the interface. Crystal growth is performed by moving the furnace (i.e. the temperature profile) from the left to right at a definite rate. Thus, we will grow crystals both on Earth and in space under the same conditions. As previously described, it is possible to obtain good quality crystals which are homogeneous in composition both macroscopically and microscopically due to the lack of convection in space. We are planning to study the effects of convection on crystal growth from a melt by comparing and characterizing the properties of crystals grown on Earth with those grown in space.

Tatsumi, Masami↗