Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material characterization methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Self‐Assembly Methods Induce Different Individual‐Polymer‐Block Solvation Responses

An understanding of block-specific responses to stimuli in self-assembled copolymers is essential for the effective design of responsive materials. Here, materials formed from different post-reaction processing methods of the same ROMP block copolymer exhibit different block-specific solvent responses, as characterized in situ by fluorescence lifetime imaging microscopy (FLIM). FLIM data were acquired by tagging the polar or nonpolar block separately with a covalently incorporated viscosity-sensitive fluorescent molecular rotor to measure the changing tightness or looseness of assembly upon changes in solvent composition. Rapid precipitation from an insoluble solvent to form a film results in tighter assembly and less difference in tightness/looseness between the two blocks. Further, it interrupts individual block-solvent response behavior. Both results indicate an apparent disruption of the core–shell assembly. This model from FLIM is further supported by differential scanning calorimetry (DSC) and small-angle X-ray scattering (SAXS) data from isolated solids, which show tighter long-range interactions and more long-range order in these kinetically trapped states. Here, the experiments develop FLIM as a method for pinpointing stimuli-responsive behaviors from different processing methods to individual blocks. Together these outcomes provide a future handle for tailoring solvent-triggered assembly/disassembly behavior.

López, Pía A. [University of California, Irvine, C↗

Time of Flight Secondary Ion Mass Spectrometry for Characterization of Pt-Coated Porous Transport Layers in PEM Water Electrolyzers

Titanium-based porous transport layers (PTLs) and iridium-based catalyst layers (CLs) are two main components of proton exchange membrane water electrolyzers (PEMWEs). PTLs are typically coated with platinum to minimize interfacial losses and to support long-term operation. Optimizing coatings and the PTL-CL interface requires comprehensive characterization. This study establishes time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a valuable technique for PTL characterization, addressing capabilities and limitations related to PTL morphology. A methodology was developed that uses a Cs + sputter beam for dynamic depth profiling, with data collected in both positive-ion (MCs + ) and negative-ion modes to generate depth profiles, 2D ion maps, and 3D ion reconstructions. ToF-SIMS detected relative differences in platinum-layer thickness between samples; these trends were validated by cross-sectional scanning transmission electron microscope (STEM) measurements and flat-titanium substrate controls. Interfacial oxide layers are identified in both ion modes, with enhanced oxide sensitivity in negative mode. The technique’s high sensitivity enables detection of nanometer-scale coatings and trace impurities within the bulk PTL structure. These results provide a methodological framework for analyzing Pt-coated PTLs, with the potential to extend to other components in PEMWEs and other electrolyzer systems.

36 MATERIALS SCIENCE↗

A self-supervised robotic system for autonomous contact-based spatial mapping of semiconductor properties

Integrating robotically driven contact-based material characterization techniques into self-driving laboratories can enhance measurement quality, reliability, and throughput. While deep learning models support robust autonomy, current methods lack reliable pixel-precision positioning and require extensive labeled data. To overcome these challenges, we propose an approach for building self-supervised autonomy into contact-based robotic systems that teach the robot to follow domain expert measurement principles at high throughputs. We demonstrate the performance of this approach by autonomously driving a 4-DOF robotic probe for 24 hours to characterize semiconductor photoconductivity at 3025 uniquely predicted poses across a gradient of drop-casted perovskite film compositions, achieving throughputs of more than 125 measurements per hour. Spatially mapping photoconductivity onto each drop-casted film reveals compositional trends and regions of inhomogeneity, valuable for identifying manufacturing defects. With this self-supervised neural network–driven robotic system, we enable high-precision and reliable automation of contact-based characterization techniques at high throughputs, thereby allowing measurement of previously inaccessible yet important semiconductor properties for self-driving laboratories.

Science & Technology - Other Topics↗

Probabilistic high cycle fatigue failure analysis with application to liquid propellant rocket engines

A probabilistic high cycle fatigue (HCF) failure analysis of a welded duct in a rocket engine of the Space Shuttle main engine class is described. A state-of-the-art HCF failure prediction method was used in a Monte Carlo simulation to generate a distribution of failure lives. A stochastic stress/life model is used for material characterization, and a composite stress history is generated for accurately deriving the stress cycles for the fatigue-damage calculations. The HCF failure model expresses fatigue life as a function of stochastic parameters including environment, loads, material properties, geometry, and model specification errors. A series of HCF failure life analyses were performed to study the impact of a fixed parameter and to assess the importance of each stochastic input parameter through marginal analyses.

Sutharshana, S.↗

Metallurgical coatings and thin films; Proceedings of the International Conference, 18th, San Diego, CA, Apr. 22-26, 1991. Vols. 1 & 2

A conference on metallurgical coatings and thin films produced papers in the areas of coatings for use at high temperatures; hard coatings and deposition technologies; diamonds and related materials; tribological coatings/surface modifications; thin films for microelectronics and high temperature superconductors; optical coatings, film characterization, magneto-optics, and guided waves; and methods for characterizing films and modified surfaces.

Mcguire, Gary E.↗

NASA's Ground-Based Observing Campaigns of Rocket Bodies with the UKIRT and NASA ES-MCAT Telescopes

Rocket bodies comprise a class of human-made space debris that are at the same time essential for launching every spacecraft from the Earth, but are also a significant source of debris both as intact objects, as well as fragmented debris. Unspent fuel has been long theorized as a potential cause of catastrophic rocket body break-ups. Given typical orbital speeds range from approximately 2-3 kilometers per second at Geosynchronous Orbit (GEO) and up to 15 kilometers per second in low Earth orbit (LEO), collisions with uncatalogued and undetected debris can also cause catastrophic breakups. Understanding break-ups is a necessary step in preventing them, and one key step in that process is to correlate and characterize daughter fragments with their parent bodies. Two very different methods include (1) conducting photometric surveys to correlate an object's motion and orbital elements to the parent body, and (2) characterizing what materials comprise the target to determine whether those materials are consistent with the parent body or like objects. With this in mind, photometric data were taken shortly after the breakup of one rocket body for short-term orbital studies, and a suite of spectral data were taken of rocket bodies that are fully intact to compare with debris, for characterization studies. Targets included Titan Transtage, Briz-M, and Ariane rocket bodies and debris. Spectra of each sub-class of rocket body were very similar within their rocket body type, but differed distinctly from one type to the next, supporting the effectiveness of this approach.

Lederer, Susan M.↗

Multifunctional Polymers and Composites for Aerospace Applications

System needs and challenges for commercial aviation and space exploration are constantly changing. Multifunctional materials are ideal for aerospace applications because their integration into structural components has potential to not only improve efficiency, but it can also increase payload and mission capabilities without the burden of significant additions to mass and volume. Multi-constituent materials will play an important role in enabling structures with the potential to demonstrate true multi-functionality; however, modifications to many mature polymer processing methods may be necessary. This presentation will cover multifunctional materials development efforts underway at the NASA Glenn Research Center related to formulating and characterizing novel electrical insulation for high voltage aircraft. Incorporating functionality into the reinforcement material is another materials development technique that will be discussed, which includes braiding with hybrid fibers to enhance toughness in composite structures, stitching with carbon nanotube yarns to make durable electrically conductive textiles, and treating fabrics with shear thickening fluid suspensions to produce impact-resistant inflatable habitats.

multi-functional composites↗

Changes in Oculomotor Behavior and PVT Reaction Time During One Night of Sleep Deprivation

INTRODUCTION: The Psychomotor Vigilance Test (PVT) is a widely used objective measure of sustained attention, alertness, and fatigue. Previous studies consistently show that prolonged wakefulness and disrupted sleep patterns lead to increased lapses of attention and slower reaction times. These findings have critical implications for various professions, including healthcare, aviation, transportation safety, and spaceflight. In this study, we employed linear mixed models (LMM) to investigate hourly-measured 5-minute PVT reaction times during one night of total sleep deprivation. Our goal was to characterize the contribution of homeostatic sleep pressure (time awake) and circadian phase (salivary melatonin levels) on the dynamics of PVT reaction time. MATERIALS & METHODS: Data from twelve human participants were used in the analysis. Participants were healthy non-smokers, aged 18 and 40, with normal sleep habits defined as Pittsburg Sleep Quality Index scores < 5, and Morningness – Eveningness Questionnaire scores > 42 and < 58, respectively. Participants followed a constant-routine protocol and arrived at the NASA sleep laboratory approximately 1 to 2 hours after their habitual waking time. Tympanic temperature was measured every 30 min to provide a real-time estimate of circadian phase. Participants were required to stay awake throughout the laboratory experiment, which continued until their tympanic temperature had returned to baseline levels. This approach ensured that we could capture each participant's circadian trough and recovery, typically occurring between 24 and 26 hours after waking. The PVT and saliva melatonin were measured every hour, starting approximately from 3 hours after awakening. More information about the measurement protocol can be found in the publication by Stone et al. We used PVT reaction times between 100 and 10000 ms to calculate Reciprocal Reaction Times (RRTs). LMM models were employed to assess the contribution of time awake and saliva melatonin levels on changes in RRTs. Two models were created: the first model treated time awake as a fixed effect and the second model considered both the salivary melatonin level and time awake as fixed effects. Participants were included as a random effect in both models. We compared the models using an Analysis of Variance (ANOVA). The models were computed using the 'lmer' function from the 'lme4' package in R, and LMM p-values were determined using Satterthwaite's method. RESULTS: We found that time awake had a statistically significant effect on PVT RRTs during one night of sleep deprivation [χ2 = 2132.4, df = 1, p < 0.001]. In addition, the model including both saliva melatonin levels and time awake was statistically significantly better than one that uses just time awake [χ2 = 17.4, df = 1, p < 0.001]. DISCUSSION & CONCLUSION: As expected, these preliminary results suggest that the time awake and circadian phase each contribute to performance reductions as measured by the PVT. Future analyses will explore the contributions of other factors to the model.

sleep deprivation↗

Analysis of Photothermal Characterization of Layered Materials: Design of Optimal Experiments

In this paper numerical calculations are presented for the steady-periodic temperature in layered materials and functionally-graded materials to simulate photothermal methods for the measurement of thermal properties. No laboratory experiments were performed. The temperature is found from a new Green s function formulation which is particularly well-suited to machine calculation. The simulation method is verified by comparison with literature data for a layered material. The method is applied to a class of two-component functionally-graded materials and results for temperature and sensitivity coefficients are presented. An optimality criterion, based on the sensitivity coefficients, is used for choosing what experimental conditions will be needed for photothermal measurements to determine the spatial distribution of thermal properties. This method for optimal experiment design is completely general and may be applied to any photothermal technique and to any functionally-graded material.

Cole, Kevin D.↗

Characterization of NU-LHT-4M Lunar Regolith Simulant Using Different Raman Configurations

As much as possible, structures to help sustain a long-term human presence on the moon will be constructed via in-situ resource utilization (ISRU) from lunar regolith. Various processes have been proposed to make lunar regolith-based construction materials, but one complication is that the lunar regolith is relatively complex in terms of composition and can vary quite significantly from one site to another. Some of these methods to make lunar regolith-based construction materials are quite sensitive to the composition and so in-situ methods for evaluating the composition of the lunar regolith could be critical. Various analytical instrumentation has been proposed for in-situ characterization of the composition of regolith on planetary bodies. Raman spectroscopy has been suggested and has some advantages over other in-situ techniques, such as potential for relatively high spatial resolution, direct determination of the mineralogy (while other methods may only infer the mineralogy), nondestructive analysis, relatively simple instrument configurations, and minimal sample preparation/handling. For example, Raman instrumentation has already been deployed in rover-based missions to Mars. Previously, we developed the Standoff Ultracompact Micro-Raman Sensor (SUCR), which is a portable Raman spectroscopy instrument capable to be integrated into a rover or onto a lander. Here, we present work on Raman spectroscopy measurements of NU-LHT-4M lunar simulant using three different Raman instruments with different configurations for collecting Raman data with the goal to explore the effect of these different configurations on the results, especially for use in a lunar environment.

Raman Spectroscopy↗

Multi-Level Structural Damage Characterization Using Sparse Acoustic Sensor Networks and Knowledge Transferred Deep Learning

Standard structural health monitoring techniques face well-known difficulties for comprehensive defect diagnosis in real-world structures that have structural, material, or geometric complexity. This motivates the exploration of machine-learning-based structural health monitoring methods in complex structures. However, creating sufficient training data sets with various defects is an ongoing challenge for data-driven machine (deep) learning algorithms. The ability to transfer the knowledge of a trained neural network from one component to another or to other sections of the same component would drastically reduce the required training data set. Also, it would facilitate computationally inexpensive machine learning based inspection systems. In this work, a machine-learning-based multi-level damage characterization is demonstrated with the ability to transfer trained knowledge within the sparse sensor network. A novel network spatial assistance and an adaptive convolution technique are proposed for efficient knowledge transfer within the deep learning algorithm. Proposed structural health monitoring method is experimentally evaluated on an aluminum plate with artificially induced defects. It was observed that the method improves the performance of knowledge transferred damage characterization by 50% during localization and 24% during severity assessment. Further, experiments using time windows with and without multiple edge reflections are studied. Results reveal that multiply scattered waves contain rich and deterministic defect signatures that can be mined using deep learning neural networks, improving the accuracy of both identification and quantification. In the case of a fixed sensor network, using multiply scattered waves shows 100% prediction accuracy at all levels of damage characterization.

36 MATERIALS SCIENCE↗

A Method for Characterizing PMR-15 Resin

Quantitative analysis technique based on reverse-phase, highperformance liquid chromatography (HPLC) and paired-ion chromatography (PIC) developed for PMR-15 resins. In reverse-phase HPLC experiment, polar solvent containing material to be analyzed passed through column packed with nonpolar substrate. Composition of PMR-15 Resin of 50 weight percent changes as resin ages at room temperature. Verification of proper resin formulation and analysis of changes in resin composition during storage important to manufacturers of PMR-15 polymer matrix composite parts. Technique especially suitable for commercial use by manufacturers of high-performance composite components.

Roberts, G. D.↗

Electrochemical Activation of Ni–Fe Oxides for the Oxygen Evolution Reaction in Alkaline Media

The oxygen evolution reaction (OER) is essential to many key electrochemical devices, including H 2 O electrolyzers, CO 2 electrolyzers, and metal−air batteries. NiFe oxides have been historically identified as active for the OER, though they have been less studied in their more commercially relevant bulk oxide forms, such as NiFe 2 O 4 . Past works have demonstrated that the initial starting phase of Ni(Fe) precatalysts can influence their activation to the Ni(Fe)OOH active phase, including the rate and degree of conversion, pointing to the necessity of understanding activation protocols and in situ characteristics of catalyst materials at the device level. In this work, we investigate the characteristics of commercially relevant NiFe bulk oxides (NiFe 2 O 4 and a physical mixture of NiO and γ-Fe 2 O 3 ) during multiple activation procedures. Our results demonstrate that significant performance enhancement is observed for these bulk oxides regardless of the Fe incorporation in the initial form (i.e., atomically or macroscopically integrated), leading to significant performance enhancement (up to 30×) over time on stream. We hypothesize that this activation is due to the formation of NiFeOOH active sites on the surface, supported by in situ cyclic voltammetry and Raman spectroscopy results. We further show that not only the starting material but also the method of activation influences the number of Ni(Fe)OOH active sites formed and suggest that these sites can be quantified from the Ni 2+ to Ni 3+ redox transition using cyclic voltammetry. Broadly, this work demonstrates the necessity of in situ characterization of catalyst materials for cell-level design and testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical Techniques for Retrieval of Atmospheric Composition with the Quadrupole Mass Spectrometer of the Sample Analysis at Mars Instrument Suite on Mars Science Laboratory

The Sample Analysis at Mars (SAM) instrument suite is the largest scientific payload on the Mars Science Laboratory (MSL) Curiosity rover, which landed in Mars׳ Gale Crater in August 2012. As a miniature geochemical laboratory, SAM is well-equipped to address multiple aspects of MSL׳s primary science goal, characterizing the potential past or present habitability of Gale Crater. Atmospheric measurements support this goal through compositional investigations relevant to martian climate evolution. SAM instruments include a quadrupole mass spectrometer, a tunable laser spectrometer, and a gas chromatograph that are used to analyze martian atmospheric gases as well as volatiles released by pyrolysis of solid surface materials (Mahaffy et al., 2012). This report presents analytical methods for retrieving the chemical and isotopic composition of Mars׳ atmosphere from measurements obtained with SAM׳s quadrupole mass spectrometer. It provides empirical calibration constants for computing volume mixing ratios of the most abundant atmospheric species and analytical functions to correct for instrument artifacts and to characterize measurement uncertainties. Finally, we discuss differences in volume mixing ratios of the martian atmosphere as determined by SAM (Mahaffy et al., 2013) and Viking (Owen et al., 1977, Oyama and Berdahl, 1977) from an analytical perspective. Although the focus of this paper is atmospheric observations, much of the material concerning corrections for instrumental effects also applies to reduction of data acquired with SAM from analysis of solid samples.

quadropole mass spectometer↗

femto-PIXAR: a self-supervised neural network method for reconstructing femtosecond X-ray free electron laser pulses

X-ray Free Electron Lasers (X-FELs) operate in a wide range of lasing configurations for a broad variety of scientific applications at ultrafast time-scales such as structural biology, materials science, and atomic and molecular physics. Shot-by-shot characterization of the X-FEL pulses is crucial for analysis of many experiments as well as tuning the X-FEL performance. However, for the weak pulses found in advanced configurations, e.g. those needed for coherent, two-pulse studies of quantum materials, there is no current method for reliably resolving pulse profiles. Here we show that a physics-based U-net model can reconstruct the individual pulse power profiles for sub-picosecond pulse separation without the need for simulations. Using experimental data from weak X-FEL pulse pairs, we demonstrate we can learn the pulse characteristics on a shot-by-shot basis when conventional methods fail.

43 PARTICLE ACCELERATORS↗