Search NASA⌕ Search

SEARCH · Search NASA

Results for “Methods and Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Development of a Test Technique to Determine the Thermal Conductivity of Large Refractory Ceramic Test Specimens

A method has been developed to utilize the High Intensity Infrared lamp located at Oak Ridge National Laboratory for the measurement of thermal conductivity of bulk refractory materials at elevated temperatures. The applicability of standardized test methods to determine the thermal conductivity of refractory materials at elevated temperatures is limited to small sample sizes (laser flash) or older test methods (hot wire, guarded hot plate), which have their own inherent problems. A new method, based on the principle of the laser flash method, but capable of evaluating test specimens on the order of 200 x 250 x 50 mm has been developed. Tests have been performed to validate the method and preliminary results are presented in this paper.

36 MATERIALS SCIENCE↗

PMU-data-driven Event Classification in Power Transmission Grids

This paper presents an event classification in transmission grids. The convolutional neural network (CNN)-based classifier is proposed to capture the temporal similarity of time-synchronized data stream from phasor measurement units (PMUs). The proposed CNN is trained using Bayesian optimization to search for the best hyperparameters. The effectiveness of the proposed event classification is validated through the real-world dataset from the U.S. transmission grids. This dataset includes line outage, transformer outage, frequency, and oscillation events. The validation process also includes different PMU outputs, such as voltage magnitude, phase angle, current magnitude, frequency, and rate of change of frequency (ROCOF). The results show that ROCOF gives the best classification performance compared to other PMU outputs. In addition, it is shown that the classifier trained with a larger dataset has higher accuracy. Moreover, the superiority of the proposed method is validated through comparison with other state-of-the-art classification methods.

Niazazari, Iman↗

The Oxidation Mechanism of Pure Magnesium Powder Particles: A Mathematical Approach

In this study, the mechanism of nonisothermal oxidation of magnesium powder was determined using a tension analysis, which was performed by mathematical modeling and the finite element method. The results revealed that phase transformation of magnesium hydroxide to magnesium oxide in the oxide layer plays an important role in this process so that formation of magnesium hydroxide in the early stages of oxidation (< 450 °C) leads to the formation of compressive stresses through the oxide layer, and as a result, the beginning of measurable oxidation is delayed. The results obtained by the mathematical model and finite element method were validated by the experimental results.

36 MATERIALS SCIENCE↗

Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX

Purpose: The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. Methods: The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. Results: For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. Conclusions: For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental measurements of gas-particle flows in large-scale strippers

Measurements of gas–solid particle flow in a large-scale stripper unit are reported. The experiments target industrial (pilot) scale measurements of gas-particle flow that can be used to validate numerical methods for modeling multiphase flows, such as computational fluid dynamics coupled to the discrete element method (CFD-DEM). Specifically, experiments were performed with Geldart Group B (533 µm) glass beads in a stripper unit. In general, previous CFD-DEM validation datasets were performed in benchtop experimental systems and limited to O(10 5 ) particles. Here, in this work, the number of particles in the isolated section of the stripper is O(10 7 ) for all tests. Measurements are reported for a ~2 m tall section of the ~1 m diameter stripper. Radial mass flux profiles measured at five axial positions and three axial pressure drop measurements are reported for six operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of persistent contaminants and personal care products by dispersive liquid-liquid microextraction using hydrophobic magnetic deep eutectic solvents

Here, in this work, hydrophobic magnetic deep eutectic solvents (HMDESs) were used in the development of a simple and rapid dispersive liquid-liquid microextraction (DLLME) approach coupled to high performance liquid chromatography with UV detection (HPLC-UV) for the determination of ten organic contaminants including five polycyclic aromatic hydrocarbons, four UV filters, and a pesticide from water at trace levels. The HMDESs were prepared by mixing a hydrogen bond acceptor, metal halide salt, and hydrogen bond donor in suitable molar ratios. Two HMDESs, 2 tetraoctylammonium bromide ([N 8888 + ][Br - ]): cobalt chloride (CoCl 2 ): 4 octanoic acid (OA) and 3 trioctylphosphine oxide (TOPO): neodymium chloride (NdCl 3 ): 3 OA, offered the highest analyte extraction efficiency overall and were chosen as suitable solvents for validation of the microextraction method. Under optimized extraction conditions, the method required 30 µL of HMDES as extraction solvent, acetone (87.5 µL) as disperser solvent, a NaCl concentration of 30% (w/v), and an extraction time of 120 s at 20°C. Enrichment factors of the analytes ranged from 44.6 for 3-(4-methylbenzylindene) camphor to 66.0 for 2-ethylhexyl-4-(dimethyl)aminobenzoate. The method provided low limits of detection (LODs) ranging from 0.5 to 4.5 µg L -1 , and acceptable precision, with RSD values lower than 9.6%. Furthermore, the validated method was successfully applied for tap and lake water analysis, resulting in relative recoveries of spiked samples ranging between 94.7 and 119.2%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Algorithm for Enhancing the Image Contrast of Electron Tomography

Abstract Three-dimensional (3D) reconstruction of a single protein molecule is essential for understanding the relationship between the structural dynamics and functions of the protein. Electron tomography (ET) provides a tool for imaging an individual particle of protein from a series of tilted angles. Individual-particle electron tomography (IPET) provides an approach for reconstructing a 3D density map from a single targeted protein particle (without averaging from different particles of this type of protein), in which the target particle was imaged from a series of tilting angles. However, owing to radiation damage limitations, low-dose images (high noise, and low image contrast) are often challenging to be aligned for 3D reconstruction at intermediate resolution (1–3 nm). Here, we propose a computational method to enhance the image contrast, without increasing any experimental dose, for IPET 3D reconstruction. Using an edge-preserving smoothing-based multi-scale image decomposition algorithm, this method can detect the object against a high-noise background and enhance the object image contrast without increasing the noise level or significantly decreasing the image resolution. The method was validated by using both negative staining (NS) ET and cryo-ET images. The successful 3D reconstruction of a small molecule (<100 kDa) indicated that this method can be used as a supporting tool to current ET 3D reconstruction methods for studying protein dynamics via structure determination from each individual particle of the same type of protein.

47 OTHER INSTRUMENTATION↗

Primordial Non-Gaussianities and Zero-Bias Tracers of the Large-Scale Structure

In this study, we develop a new method to constrain primordial non-Gaussianities of the local kind using unclustered tracers of the large scale structure. We show that, in the limit of low noise, zero bias tracers yield large improvement over standard methods, mostly due to vanishing sampling variance. We propose a simple technique to construct such a tracer, using environmental information obtained from the original sample and validate our method with $N$-body simulations. Our results indicate that σ $f$$loc\atop{NL}$ ≃ 1 can be reached using only information on a single tracer of sufficiently high number density.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-DE-207B-04: Quantitative Contrast-Enhanced Spectral Mammography Based On Photon-Counting Detectors: A Feasibility Study

Purpose: To investigate the feasibility of accurate quantification of iodine mass thickness in contrast-enhanced spectral mammography. Methods: Experimental phantom studies were performed on a spectral mammography system based on Si strip photon-counting detectors. Dual-energy images were acquired using 40 kVp and a splitting energy of 34 keV with 3 mm Al pre-filtration. The initial calibration was done with glandular and adipose tissue equivalent phantoms of uniform thicknesses and iodine disk phantoms of various concentrations. A secondary calibration was carried out using the iodine signal obtained from the dual-energy decomposed images and the known background phantom thicknesses and densities. The iodine signal quantification method was validated using phantoms composed of a mixture of glandular and adipose materials, for various breast thicknesses and densities. Finally, the traditional dual-energy weighted subtraction method was also studied as a comparison. The measured iodine signal from both methods was compared to the known iodine concentrations of the disk phantoms to characterize the quantification accuracy. Results: There was good agreement between the iodine mass thicknesses measured using the proposed method and the known values. The root-mean-square (RMS) error was estimated to be 0.2 mg/cm2. The traditional weighted subtraction method also predicted a linear correlation between the measured signal and the known iodine mass thickness. However, the correlation slope and offset values were strongly dependent on the total breast thickness and density. Conclusion: The results of the current study suggest that iodine mass thickness can be accurately quantified with contrast-enhanced spectral mammography. The quantitative information can potentially improve the differentiation between benign and malignant legions. Grant funding from Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗

Optimization of Operating Parameters for Minimum Mechanical Specific Energy in Drilling

Efficiency in drilling is measured by Mechanical Specific Energy (MSE). MSE is the measure of the amount of energy input required to remove a unit volume of rock, expressed in units of energy input divided by volume removed. It can be expressed mathematically in terms of controllable parameters; Weight on Bit, Torque, Rate of Penetration, and RPM. It is well documented that minimizing MSE by optimizing controllable factors results in maximum Rate of Penetration. Current methods for computing MSE make it possible to minimize MSE in the field only through a trial-and-error process. This work makes it possible to compute the optimum drilling parameters that result in minimum MSE. The parameters that have been traditionally used to compute MSE are interdependent. Mathematical relationships between the parameters were established, and the conventional MSE equation was rewritten in terms of a single parameter, Weight on Bit, establishing a form that can be minimized mathematically. Once the optimum Weight on Bit was determined, the interdependent relationship that Weight on Bit has with Torque and Penetration per Revolution was used to determine optimum values for those parameters for a given drilling situation. The improved method was validated through laboratory experimentation and analysis of published data. Two rock types were subjected to four treatments each, and drilled in a controlled laboratory environment. The method was applied in each case, and the optimum parameters for minimum MSE were computed. The method demonstrated an accurate means to determine optimum drilling parameters of Weight on Bit, Torque, and Penetration per Revolution. A unique application of micro-cracking is also presented, which demonstrates that rock failure ahead of the bit is related to axial force more than to rotation speed.

42 ENGINEERING↗

Environmental Durability Assessment and Development of Subcomponent Test Methods for Advanced Materials in Marine Energy Applications

Marine energy developers are beginning to rely more heavily on advanced composite materials for their load-bearing structures. Understanding how these materials respond and degrade in harsh marine environments is a complex problem. Much research has been performed at smaller laboratory scales to understand the fundamental physical and chemical degradation mechanisms, but little structural testing research has been performed at larger scales to understand how these physical and chemical interactions scale and how they should be accounted for in the design process. The Advanced Materials project is a multilaboratory research collaboration that addresses these issues with the intention of reducing risks and barriers to marine energy developers wanting to adopt advanced composite materials. The National Laboratory of the Rockies has been playing a leading role in developing larger-scale testing infrastructure and test methods to validate complex numerical degradation models and standardize testing procedures to do so. This paper reviews past structural testing activities, how they have grown into current research activities, and how they will continue to evolve to directly address industry needs. This paper covers key research areas - large-scale water absorption and subsequent structural validation testing, qualification of bolted and adhesive connections, and combined submerged fatigue testing at increasing scales. It provides insights into the complex requirements for testing infrastructure and test method development to effectively qualify materials and certify marine energy structures for harsh marine environments. This research program paves the way for better guidance and standardization within the industry when adopting advanced composite materials.

16 TIDAL AND WAVE POWER↗

Characterization and Monte Carlo Simulations of a 4-Liter NaI Detection System for Use During Nuclear and Radiological Emergencies and for the Detection of Nuclear Materials

SCKCEN is engaged in research related to the use of a large volume NaI detection system for use during nuclear and radiological emergencies and for the detection of nuclear materials. As part of this effort a research activity is being carried out to determine the characteristics and build a Monte Carlo model of the available 4-liter NaI detector. These activities consist of (i) determination of energy resolution efficiency lower threshold background in laboratory conditions using well-characterized point sources; (ii) modeling of the detector by Monte Carlo methods and validation; (iii) determination of the response function by combining measurement and simulation results; (iv) characterization of the detector for contaminated surfaces by measurements and modeling; and (v) calibration of detector for dose rate measurements. This paper will focus on the results obtained so far concerning the Monte Carlo model and its validation with experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chokepoints in Mechanical Coupling Associated with Allosteric Proteins: The Pyruvate Kinase Example

Although the critical role of allostery in controlling enzymatic processes is well appreciated, there is a current dearth in our understanding of its underlying mechanisms, including communication between binding sites. One potential key aspect of inter-site communication is the mechanical coupling between residues in a protein. Here, we introduce a graph-based computational approach to investigate the mechanical coupling between distant parts of a protein, highlighting effective pathways via which protein motion can transfer energy between sites. In this method, each residue is treated as a node on a weighted, undirected graph, where the edges are defined by locally correlated motions of those residues and weighted by the strength of the correlation. The method was validated against experimental data on allosteric regulation in the human liver pyruvate kinase as obtained from full-protein alanine-scanning mutagenesis (systematic mutation) studies. The method provides semi-quantitative information on the regulatory importance of specific structural elements. It is shown that these elements are key for the mechanical coupling between distant parts of the protein by providing effective pathway for energy transfer. It is also shown that, while there are a multitude of energy transfer pathways between distant parts of a protein, these pathways share a few common nodes that represent effective “chokepoints.”

Johnson, Lewis E.↗

Heat transport in silicon from first-principles calculations

Using harmonic and anharmonic force constants extracted from density functional calculations within a supercell, we have developed a relatively simple but general method to compute thermodynamic and thermal properties of any crystal. First, from the harmonic, cubic, and quartic force constants, we construct a force field for molecular dynamics. It is exact in the limit of small atomic displacements and thus does not suffer from inaccuracies inherent in semiempirical potentials such as Stillinger-Weber's. By using the Green-Kubo formula and molecular dynamics simulations, we extract the bulk thermal conductivity. This method is accurate at high temperatures where three-phonon processes need to be included to higher orders, but may suffer from size scaling issues. Next, we use perturbation theory (Fermi golden rule) to extract the phonon lifetimes and compute the thermal conductivity κ from the relaxation-time approximation. This method is valid at most temperatures, but will overestimate κ at very high temperatures, where higher-order processes neglected in our calculations also contribute. As a test, these methods are applied to bulk crystalline silicon, and the results are compared and differences are discussed in more detail. The presented methodology paves the way for a systematic approach to model heat transport in solids using multiscale modeling, in which the relaxation time due to anharmonic three-phonon processes is calculated quantitatively, in addition to the usual harmonic properties such as phonon frequencies and group velocities. As a result it also allows the construction of an accurate bulk interatomic potentials database.

36 MATERIALS SCIENCE↗

Drying/self-assembly of nanoparticle suspensions.

The most feasible way to disperse particles in a bulk material or control their packing at a substrate is through fluidization in a carrier that can be processed with well-known techniques such as spin, drip and spray coating, fiber drawing, and casting. The next stage in the processing is often solidification involving drying by solvent evaporation. While there has been significant progress in the past few years in developing discrete element numerical methods to model dense nanoparticle dispersion/suspension rheology which properly treat the hydrodynamic interactions of the solvent, these methods cannot at present account for the volume reduction of the suspension due to solvent evaporation. As part of LDRD project FY-101285 we have developed and implemented methods in the current suite of discrete element methods to remove solvent particles and volume, and hence solvent mass from the liquid/vapor interface of a suspension to account for volume reduction (solvent drying) effects. To validate the methods large scale molecular dynamics simulations have been carried out to follow the evaporation process at the microscopic scale.

36 MATERIALS SCIENCE↗

Estimation of Turbulence Parameters from Scanning Lidars and in-situ Instrumentation in the Perdigao 2017 Campaign

The understanding of the sources, spatial distribution and temporal variability of turbulence in the atmospheric boundary layer (ABL) and improved simulation of its forcing processes require observations in a broad range of terrain types and atmospheric conditions. In this study, we estimate turbulence kinetic energy (TKE) dissipation rate using multiple techniques, including traditional in-situ measurements of sonic anemometers on meteorological towers, a hot-wire anemometer on a tethered lifting system (TLS), as well as remote-sensing retrievals from a vertically staring lidar and two lidars performing range-height indicator (RHI) scans. For the retrieval of e from the lidar RHI scans, we introduce a modification of the Doppler Spectral Width (DSW) method. This method uses spatio-temporal averages of the variance of the line-of-sight (LOS) velocity and the turbulent broadening of the Doppler backscatter spectrum. We validate this method against the observations from the other instruments, also including uncertainty estimations for each method. The synthesis of the results from all instruments enables a detailed analysis of the spatial and temporal variability of e across a valley between two parallel ridges at the Perdigao 2017 campaign. We find that the shear zones above and below nighttime low-level jets (LLJ) experience turbulence enhancements, as does the wake of a wind turbine (WT). We analyze in detail how e varies in the early morning of 14 June 2017, when the turbulence in the valley, approximately eleven rotor diameters downstream of the WT, is still significantly enhanced by the WT wake.

17 WIND ENERGY↗

SU-E-T-175: Clinical Evaluations of Monte Carlo-Based Inverse Treatment Plan Optimization for Intensity Modulated Radiotherapy

Purpose: Pencil-beam or superposition-convolution type dose calculation algorithms are routinely used in inverse plan optimization for intensity modulated radiation therapy (IMRT). However, due to their limited accuracy in some challenging cases, e.g. lung, the resulting dose may lose its optimality after being recomputed using an accurate algorithm, e.g. Monte Carlo (MC). It is the objective of this study to evaluate the feasibility and advantages of a new method to include MC in the treatment planning process. Methods: We developed a scheme to iteratively perform MC-based beamlet dose calculations and plan optimization. In the MC stage, a GPU-based dose engine was used and the particle number sampled from a beamlet was proportional to its optimized fluence from the previous step. We tested this scheme in four lung cancer IMRT cases. For each case, the original plan dose, plan dose re-computed by MC, and dose optimized by our scheme were obtained. Clinically relevant dosimetric quantities in these three plans were compared. Results: Although the original plan achieved a satisfactory PDV dose coverage, after re-computing doses using MC method, it was found that the PTV D95% were reduced by 4.60%–6.67%. After re-optimizing these cases with our scheme, the PTV coverage was improved to the same level as in the original plan, while the critical OAR coverages were maintained to clinically acceptable levels. Regarding the computation time, it took on average 144 sec per case using only one GPU card, including both MC-based beamlet dose calculation and treatment plan optimization. Conclusion: The achieved dosimetric gains and high computational efficiency indicate the feasibility and advantages of the proposed MC-based IMRT optimization method. Comprehensive validations in more patient cases are in progress.

60 APPLIED LIFE SCIENCES↗

Quantification of the Interaction Field in Arrays of Magnetic Nanowires from the Remanence Curves

A method is presented that allows quantifying the average value of the interaction field in arrays of magnetic nanowires from the field difference between the isothermal remanence (IRM) and the DC demagnetizing (DCD) remanence curves when the normalized magnetization is equal to one third. Arrays of magnetic nanowires of different diameters and packing fractions are used to experimentally test the method. The results have been compared with those obtained using the method based on the difference between the remanence coercivity fields and with a mean-field expression for the interaction field, providing a very good agreement and thus validating the method. Additionally, it is shown that both the position (m{sub 0}) and the shift along the magnetization axis of the intersection between the remanence curves with respect to the value of one third (δm = m{sub 0} − 1/3) provide qualitative information about the interaction field. The former indicates the type of interaction depending if the intersection is above (m{sub 0} > 1/3) or below (m{sub 0} < 1/3), which corresponds to a ferro or anti-ferro magnetic interaction, respectively. While for the latter, it is shown that the maximum deviation of the Delta-M plot from zero (ΔM{sub max}) corresponds to three times the shift (ΔM{sub max} = 3δm).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗