Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microprobe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

The MicroAnalysis Toolkit: X-ray Fluorescence Image Processing Software

The MicroAnalysis Toolkit is an analysis suite designed for the processing of x-ray fluorescence microprobe data. The program contains a wide variety of analysis tools, including image maps, correlation plots, simple image math, image filtering, multiple energy image fitting, semi-quantitative elemental analysis, x-ray fluorescence spectrum analysis, principle component analysis, and tomographic reconstructions. To be as widely useful as possible, data formats from many synchrotron sources can be read by the program with more formats available by request. An overview of the most common features will be presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The X-ray Fluorescence Microscopy Beamline at the Australian Synchrotron

A hard x-ray micro-nanoprobe has commenced operation at the Australian Synchrotron providing versatile x-ray fluorescence microscopy across an incident energy range from 4 to 25 keV. Two x-ray probes are used to collect {mu}-XRF and {mu}-XANES for elemental and chemical microanalysis: a Kirkpatrick-Baez mirror microprobe for micron resolution studies and a Fresnel zone plate nanoprobe capable of 60-nm resolution. Some unique aspects of the beamline design and operation are discussed. An advanced energy dispersive x-ray fluorescence detection scheme named Maia has been developed for the beamline, which enables ultrafast x-ray fluorescence microscopy.

36 MATERIALS SCIENCE↗

Analytical Study of BAM (Al/GaAs) and Photovoltaic Samples Using State-of-The-Art Auger Nanoprobes

For the analysis of certified semiconducting Al{sub 0.7}Ga{sub 0.3}As/GaAs superlattices and photovoltaic samples, we used new generations Auger nano-probes such as the JEOL JAMP-9500F Field emission Microprobe and the PHI-700 Xi system. These nano-probes are generally used for the chemical analysis of complex nano-structures at the deca-nanometric scale. In this paper, we first used both systems for the determination of the surface composition of an Al{sub 0.7}Ga{sub 0.3}As/GaAs reference sample. In that, we studied the impact of surface topography on the Auger analysis. Secondly, we used both systems for chemical analysis of photovoltaic samples. Here, we investigated the in-depth chemical composition, in particular the a-Si:H (n)/ZnO/Al and ITO/a-Si:H (p) interfaces, after a specific cross-section preparation. However, limitations such as image drift due to acoustic vibration and heating effects due to continuous bombardment of energetic electrons at the same point are still a big challenge for quick, routine analysis.

36 MATERIALS SCIENCE↗

A plastic miniature x-ray emission spectrometer based on the cylindrical von Hamos geometry

We present a short working distance miniature x-ray emission spectrometer (miniXES) based on the cylindrical von Hamos geometry. We describe the general design principles for the spectrometer and detail a specific implementation that covers K{beta} and valence level emission from Fe. Large spatial and angular access to the sample region provides compatibility with environmental chambers, microprobe, and pump/probe measurements. The primary spectrometer structure and optic is plastic, printed using a 3-dimensional rapid-prototype machine. The spectrometer is inexpensive to construct and is portable; it can be quickly set up at any focused beamline with a tunable narrow bandwidth monochromator. The sample clearance is over 27 mm, providing compatibility with a variety of environment chambers. An overview is also given of the calibration and data processing procedures, which are implemented by a multiplatform user-friendly software package. Finally, representative measurements are presented. Background levels are below the level of the K{beta}{sub 2,5} valence emission, the weakest diagram line in the system, and photometric analysis of count rates finds that the instrument is performing at the theoretical limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlations of trace elements in breast human tissues: Evaluation of spatial distribution using {mu}-XRF

The aim of this work is to investigate microscopic correlations between trace elements in breast human tissues. A synchrotron X-ray fluorescence microprobe system ({mu}-XRF) was used to obtain two-dimensional distribution of trace element Ca, Fe, Cu and Zn in normal (6 samples) and malignant (14 samples) breast tissues. The experiment was performed in X-ray Fluorescence beam line at Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, Brazil. The white microbeam was generated with a fine conical capillary with a 20 {mu}m output diameter. The samples were supported on a XYZ table. An optical microscope with motorized zoom was used for sample positioning and choice the area to be scanned. Automatic two-dimensional scans were programmed and performed with steps of 30 {mu}m in each direction (x, y) on the selected area. The fluorescence signals were recorded using a Si(Li) detector, positioned at 90 degrees with respect to the incident beam, with a collection time of 10 s per point. The elemental maps obtained from each sample were overlap to observe correlation between trace elements. Qualitative results showed that the pairs of elements Ca-Zn and Fe-Cu could to be correlated in malignant breast tissues. Quantitative results, achieved by Spearman correlation tests, indicate that there is a spatial correlation between these pairs of elements (p < 0.001) suggesting the importance of these elements in metabolic processes associated with the development of the tumor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the method for the preparation of Mg{sub 2}Si by SPS technique

The aim of the study was to develop a fast and simple method for preparation of polycrystalline Mg{sub 2}Si. For this purpose a Spark Plasma Sintering (SPS) method was used and synthesis conditions were adjusted in such a manner that no excess Mg was required. Materials were synthesized by the direct reaction of Mg and Si raw powders. To determine the phase and chemical composition, the fabricated samples were studied by X-ray diffraction and SEM microscopy coupled with EDX chemical analysis. Thermoelectric properties of samples (thermal conductivity, electrical conductivity and Seebeck coefficient) were measured all over temperature range of 300-650 K. The analysis by the scanning thermoelectric microprobe (STM) shows that samples have uniform distribution of Seebeck coefficient with mean value of about -405 {mu}VK{sup -1} and standard deviation of 94 {mu}VK{sup -1}. Prepared materials have intrinsic band gap of 0.45 eV and thermal conductivity {lambda}= 7.5 Wm{sup -1}K{sup -1} at room temperature.

36 MATERIALS SCIENCE↗

Anisotropy analysis of thermoelectric properties of Bi{sub 2}Te{sub 2.9}Se{sub 0.1} prepared by SPS method

The n-type Bi{sub 2}Te{sub 2.9}Se{sub 0.1} materials were synthesized by the direct fusion technique. The polycrystalline samples were fabricated by the uniaxial pressing of powders in spark plasma sintering (SPS) apparatus. The materials were subjected to the heat treatment in H{sub 2}-Ar atmosphere at 470 K for 24 h. The influence of preparation conditions on the anisotropy of electrical and thermal properties was thoroughly studied for the direction perpendicular and parallel to the pressing force. The microstructure and the chemical composition of both types of samples were examined using a scanning microscope (SEM) equipped with an X-ray energy dispersion detector (EDX). The XRD method was applied for the phase analysis of materials, as well as, for determination of preferred orientation of Bi{sub 2}Te{sub 2.9}Se{sub 0.1} grains. The Seebeck coefficient distribution was studied by the scanning thermoelectric microprobe (STM). Temperature dependences of thermoelectric properties (thermal and electrical conductivities, Seebeck coefficient) were measured in the temperature from 300 K to 550 K. The statistical analysis of results has shown strong influence of pressing force direction both on structural and transport properties. The applied heat treatment of materials significantly improves their thermoelectric figure of merit. Particularly, it was found that annealing in H2-Ar atmosphere leads to enhancement of the ZT three times up to {approx}0.7 at 370 K in perpendicular direction to the pressing force.

36 MATERIALS SCIENCE↗

Zn migration during spark plasma sintering of thermoelectric Zn{sub 4}Sb{sub 3}

The phase homogeneity of spark plasma sintered thermoelectric Zn{sub 4}Sb{sub 3} pellets along the pressing direction has been studied by potential Seebeck microprobe scanning and spatially resolved x-ray diffraction. Significant variations in the Seebeck coefficient reflect presence of different crystalline phases. The emergence of the ZnSb phase at the bottom of the pellet and metallic Zn impurity at the top explains the variation in the Seebeck coefficients. Quantitative phase distributions along the pressing axis were determined from the Rietveld refinements of spatially resolved x-ray diffraction patterns. These reveal a migration of highly mobilized Zn atoms under the direct current applied during spark plasma sintering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A digitizer based compact digital spectrometer for ion beam analysis using field programmable gate arrays and various energy algorithms

We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs/outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector/preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field emission properties of chemical vapor deposited individual graphene

Here, we report field emission (FE) properties of a chemical vapor deposited individual graphene investigated by in-situ transmission electron microscopy. Free-standing bilayer graphene is mounted on a cathode microprobe and FE processes are investigated varying the vacuum gap of cathode and anode. The threshold field for 10 nA current were found to be 515, 610, and 870 V/μm for vacuum gap of 400, 300, and 200 nm, respectively. It is observed that the structural stability of a high quality bilayer graphene is considerably stable during emission process. By contacting the nanoprobe with graphene and applying a bias voltage, structural deformation and buckling are observed with significant rise in temperature owing to Joule heating effect. The finding can be significant for practical application of graphene related materials in emitter based devices as well as understanding the contact resistance influence and heating effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microsphere-chain waveguides: Focusing and transport properties

It is shown that the focusing properties of polystyrene microsphere-chain waveguides (MCWs) formed by sufficiently large spheres (D ≥ 20λ, where D is the sphere diameter and λ is the wavelength of light) scale with the sphere diameter as predicted by geometrical optics. However, this scaling behavior does not hold for mesoscale MCWs with D ≤ 10λ resulting in a periodical focusing with gradually reducing beam waists and in extremely small propagation losses. The observed effects are related to properties of nanojet-induced and periodically focused modes in such structures. The results can be used for developing focusing microprobes, laser scalpels, and polarization filters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Annealing effects on recombinative activity of nickel at direct silicon bonded interface

By performing capacitance transient analyses, the recombination activity at a (110)/(100) direct silicon bonded (DSB) interface contaminated with nickel diffused at different temperatures, as a model of grain boundaries in multicrystalline silicon, was studied. The trap level depth from the valence band, trap density of states, and hole capture cross section peaked at an annealing temperature of 300 °C. At temperatures ⩾400 °C, the hole capture cross section increased with temperature, but the density of states remained unchanged. Further, synchrotron-based X-ray analyses, microprobe X-ray fluorescence (μ-XRF), and X-ray absorption near edge structure (XANES) analyses were performed. The analysis results indicated that the chemical phase after the sample was annealed at 200 °C was a mixture of NiO and NiSi{sub 2}.

36 MATERIALS SCIENCE↗

Microstructure and defects probed by Raman spectroscopy in lithium niobate crystals and devices

Raman microprobe applied on LiNbO{sub 3} (LN) crystals and derived materials or devices is shown to be a tool to detect either local variations or changes of the whole structure. Position, width, or intensity of one Raman line can be used as markers of a structural change. Indeed, each Raman line can be assigned to a peculiar ionic motion and is differently sensitive to application of strain, temperature change, and electric field. Some vibrational modes are especially associated to the site of Li ion, or Nb ion, or still oxygen octahedron, so that they can be affected by the introduction of dopant ion on one or another site. Therefore, Raman Spectroscopy (RS) can be used as a site spectroscopy to describe the mechanism of doping incorporation in the LN lattice, allowing the optimization of some linear and non-linear optical properties according to the dopant concentration and substitution site. The composition or the content of non-stoichiometry related defects could be derived from the width of some lines. Any damage or local disorder can be detected by a line broadening. The quality or preservation of the structure after chemical treatment, or laser pulses, can be thus checked. The structure of ion-implanted or proton-exchanged wave-guides and periodically poled lithium niobate as well can be imaged from frequency shift or intensity change of some lines. RS is thus a useful way to control the structure of LN and/or to optimize the preparation parameters and its properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proton irradiation effect on thermoelectric properties of nanostructured n-type half-Heusler Hf 0.25 Zr 0.75 NiSn 0.99 Sb 0.01

Here, thermoelectric properties of nanostructured half-Heusler Hf 0.25 Zr 0.75 NiSn 0.99 Sb 0.01 were characterized before and after 2.5 MeV proton irradiation. A unique high-sensitivity scanning thermal microprobe was used to simultaneously map the irradiation effect on thermal conductivity and Seebeck coefficient with spatial resolution less than 2 μm. The thermal conductivity profile along the depth from the irradiated surface reflects excellent agreement with the irradiation-induced damage profile from simulation. The Seebeck coefficient was unaffected while both electrical and thermal conductivities decreased by 24%, resulting in no change in thermoelectric figure of merit ZT. Reductions in thermal and electrical conductivities are attributed to irradiation-induced defects that act as scattering sources for phonons and charge carriers.

36 MATERIALS SCIENCE↗

Measurement of energy spectra of small-angle scattering and distribution of optical microinhomogeneities in laser ceramics

The energy spectra of small-angle light scattering from the samples of Nd:YAG ceramics and the spatial distributions of optical microinhomogeneities in them are measured. The spatial profiles of microinhomogeneities are found using the collinear heterodyne microprobe technique. Based on the obtained data, the comparison of noise and lasing characteristics of foreign and domestic samples of laser ceramics is carried out. (extreme light fields and their applications)

36 MATERIALS SCIENCE↗

Pedothem carbonates reveal anomalous North American atmospheric circulation 70,000–55,000 years ago

Our understanding of climatic conditions, and therefore forcing factors, in North America during the past two glacial cycles is limited in part by the scarcity of long, well-dated, continuous paleoclimate records. Here, we present the first, to our knowledge, continuous, millennial-resolution paleoclimate proxy record derived from millimeter-thick pedogenic carbonate clast coatings (pedothems), which are widely distributed in semiarid to arid regions worldwide. Our new multiisotope pedothem record from the Wind River Basin in Wyoming confirms a previously hypothesized period of increased transport of Gulf of Mexico moisture northward into the continental interior from 70,000 to 55,000 years ago based on oxygen and carbon isotopes determined by ion microprobe and uranium isotopes and U-Th dating by laser ablation inductively coupled plasma mass spectrometry. This pronounced meridional moisture transport, which contrasts with the dominant zonal transport of Pacific moisture into the North American interior by westerly winds before and after 70,000–55,000 years ago, may have resulted from a persistent anticyclone developed above the North American ice sheet during Marine Isotope Stage 4. We conclude that pedothems, when analyzed using microanalytical techniques, can provide high-resolution paleoclimate records that may open new avenues into understanding past terrestrial climates in regions where paleoclimate records are not otherwise available. When pedothem paleoclimate records are combined with existing records they will add complimentary soil-based perspectives on paleoclimate conditions.

54 ENVIRONMENTAL SCIENCES↗

ASTEROIDAL GRANITE-LIKE MAGMATISM 4.53 GYR AGO

Constraining the timescales for the evolution of planetary bodies in our solar system is essential for a complete understanding of planet-forming processes. However, frequent collisions between planetesimals in the early solar system obscured and destroyed much of the primitive features of the old, first-generation planetary bodies. The presence of differentiated, achondritic clasts in brecciated chondrites and of chondritic fragments in achondritic breccias clearly witness multiple processes such as metamorphism, magmatism, fragmentation, mixing, and reaccretion. Here, we report the results of ion microprobe Pb-Pb dating of a granite-like fragment found in a meteorite, the LL3-6 ordinary chondrite regolith breccia Adzhi-Bogdo. Eight spot analyses of two phosphate grains and other co-genetic phases of the granitoid give a Pb-Pb isochron age of 4.48 {+-} 0.12 billion years (95% confidence) and a model age of 4.53 {+-} 0.03 billion years (1{sigma}), respectively. These ages represent the crystallization age of a parental granite-like magma that is significantly older than those of terrestrial (4.00-4.40 Gyr) and lunar granites (3.88-4.32 Gyr) indicating that the clast in Adzhi-Bogdo is the oldest known granitoid in the solar system. This is the first evidence that granite-like formation is not only a common process on Earth, but also occurred on primitive asteroids in the early solar system 4.53 Gyr ago. Thus, the discovery of granite magmatism recorded in a brecciated meteorite provides an innovative idea within the framework of scenarios for the formation and evolution of planetary bodies and possibly exoplanetary bodies.

99 GENERAL AND MISCELLANEOUS↗

Ne ISOTOPES IN INDIVIDUAL PRESOLAR GRAPHITE GRAINS FROM THE MURCHISON METEORITE TOGETHER WITH He, C, O, Mg-Al ISOTOPIC ANALYSES AS TRACERS OF THEIR ORIGINS

Ne isotopes measured in individual presolar graphite grains, solid samples of extinct stars preserved in primitive meteorites, provide information on the type of stellar sources of the grains and on nucleosynthetic mixing and ion-trapping processes which were operating. We present Ne and He isotope analyses of single presolar graphite grains from the KFB1 density fraction extracted from the carbonaceous chondrite Murchison. In addition, we measured isotopes of C, O, and Mg-Al with the NanoSIMS ion microprobe to better constrain the origin of the grains. Eleven out of 51 presolar graphite grains contain nucleosynthetic {sup 22}Ne above our detection limit. This fraction of {sup 22}Ne-rich grains is similar to the one reported by Nichols et al. although we have a lower {sup 22}Ne detection limit. We detected rare He-shell {sup 20}Ne in one {sup 22}Ne-rich grain and obtained the {sup 20}Ne/{sup 22}Ne ratio (0.03 {+-} 0.02) of the He-shell of an Asymptotic Giant Branch (AGB) star with 1.5-2 M {sub sun} and subsolar metallicity. We also detected {sup 4}He in this grain, while in the other grains, which originally acquired He, He-loss seems to be significant. We found unequivocal evidence for radiogenic {sup 22}Ne (Ne-R) in another graphite grain, which likely condensed in a core-collapse supernova and which incorporated live radioactive {sup 22}Na (t {sub 1/2} = 2.6 yr). For the other grains, a clear assignment to a stellar source is more difficult to make. Putative stellar sources are supernovae, AGB stars, born-again AGB stars, J-type carbon stars, and CO novae.

79 ASTRONOMY AND ASTROPHYSICS↗