Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microstrip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

First bulk and surface results for the ATLAS ITk Strip stereo annulus sensors

A novel microstrip sensor geometry, the stereo annulus, has been developed for use in the end-cap of the ATLAS experiment’s strip tracker upgrade at the HL-LHC. Its first implementation is in the ATLAS12EC sensors, a large-area, radiation-hard, single-sided, AC-coupled, n + -in-p design produced by the ITk Strip Sensor Collaboration and fabricated by Hamamatsu Photonics in early 2017. The results of the initial testing of two ATLAS12EC batches are presented here with a comparison to specification. The potential of the new sensor shape to reinvigorate endcap strip tracking is explained and its effects on sensor performance are isolated by comparing the bulk mechanical and electrical properties of the new sensor to the previous iteration of prototype, the conventional barrel ATLAS12A sensor. The surface properties of the new sensor are evaluated for full-size unirradiated sensors as well as for mini sensors unirradiated and irradiated with protons up to a fluence of 2.2 x 10 15 n eq cm -2 . The results show that the new stereo annulus ATLAS12EC sensors exhibit excellent performance and the expected irradiation evolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solution-Processed, High-Speed, and High-Quantum-Efficiency Quantum Dot Infrared Photodetectors

For over a decade, much effort has been focused on passivation of the high density of localized electronic trap states in colloidal semiconductor quantum dots (QDs), which lead to reduced performance in solar cell, light-emitting diode, laser, and photoconductor applications. However, here we take advantage of the naturally occurring high density of trap states to demonstrate solution-processed high-speed PbSe quantum dot near-infrared photodetectors. Carrier transport dynamics studies reveal multiple trapping and release transport dynamics in band tail states. A sandwich microstrip transmission line photodetector utilizing these QD films was fabricated to achieve high performance by allowing carriers to be swept to the electrodes before they fall into the band tail states. As a result, this device demonstrates external quantum efficiency, responsivity, and response time (full width at half-maximum) of 54%, 0.36 A/W, and 74 ps, respectively.

36 MATERIALS SCIENCE↗

The Heavy Photon Search experiment at Jefferson Laboratory

Many beyond Standard Model theories predict a new massive gauge boson, a.k.a. 'dark' or 'heavy photon', directly coupling to hidden sector particles with dark charge. The heavy photon is expected to mix with the Standard Model photon through kinetic mixing and therefore couple weakly to normal charge. The Heavy Photon Search (HPS) experiment will search for the heavy photon at the Thomas Jefferson National Accelerator Facility (JLab), in the mass range 20-1000 MeV/c 2 and coupling to electric charge ϵ 2 = α'/α in the range 10 -5 to 10 -10 . HPS will look for the e + e - decay channel of heavy photons radiated by electron Bremsstrahlung, employing both invariant mass search and detached vertexing techniques. The experiment employs a compact forward spectrometer comprising silicon microstrip detectors for vertexing and tracking and an electromagnetic calorimeter for particle identification and triggering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The HPS experiment at JLab

Many Beyond-Standard-Model theories predict a new massive gauge boson, such as a ?dark? or ?heavy photon?. The heavy photon is expected to mix with the Standard Model photon through kinetic mixing and therefore have a small coupling to electric charge. The Heavy Photon Search (HPS) experiment is searching for a heavy photon at the Thomas Jefferson National Accelerator Facility (JLab), in the mass range 20-500 MeV/c2. In particular HPS looks for the e+e? decay channel of heavy photons radiated by electron Bremsstrahlung, employing both an invariant mass search and detached vertexing techniques. The experiment employs a compact forward spectrometer comprising silicon microstrip detectors for vertexing and tracking and an electromagnetic calorimeter for particle identification and triggering. HPS took data successfully in 2015 and 2016 at 1.05 GeV and 2.3 GeV beam energies, respectively. First results are expected to be presented soon.

De Napoli, Marzio↗

The Heavy Photon Search (HPS) Software Environment

The Heavy Photon Search (HPS) is an experiment at the Thomas Jefferson National Accelerator Facility (JLab) designed to search for a hidden sector photon (A’) in fixed-target electro-production. It uses a silicon microstrip tracking and vertexing detector placed inside a dipole magnet to measure charged particle trajectories and a fast lead-tungstate crystal calorimeter located just downstream of the magnet to provide a trigger and to identify electromagnetic showers. The HPS experiment uses both invariant mass and secondary vertex signatures to search for the A’. The experimental collaboration is small and quite heterogeneous: it is composed of members of the nuclear physics as well as particle physics communities, from universities and national labs from around the US and Europe. Enabling such a disparate group to concentrate on the physics aspects of the experiment required that the software be easy to install and use, and having such limited manpower meant that existing solutions had to be exploited. HPS has successfully completed two engineering runs and completed its first physics run in the summer of 2019. We begin with an overview of the physics goals of the experiment followed by a short description of the detector design. We then describe the software tools used to design the detector layout and simulate the expected detector performance. Event reconstruction involving track, cluster and vertex finding and fitting for both simulated and real data was, to first order, adopted from existing software originally developed for Linear Collider studies. Bringing it all together into a cohesive whole involved the use of multiple software solutions with common interfaces.

Graf, Norman↗

X-ray diamond detectors with energy resolution

Polycrystalline diamond detectors with energy resolving capability of the impinging beam were realized and tested by using a miniature pyroelectric x-ray pulse generator. Microstrip structures were defined by photolithography aimed to reduce parasitic capacitances and to perform characterization measurements in a sandwich configuration. Leakage currents as low as 20 pA at 500 V were measured on a 270 {mu}m thick device. Pulse height distributions were carried out around Ta L{alpha} (8.14 keV) and Cu K{alpha} (8.05 keV) characteristic lines of the source. Energy resolution at 200 V was found equal to 9% with an increase to 11% at 500 V. When the bias was increased to the maximum voltage the sample shows an Ohmic behavior.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Developments for the Lamb Shift Investigation in Heavy Ions

Novel high-resolution spectrometer setups are presently commissioned for X-ray experiments at the Experimental Storage Ring (ESR) at GSI, Darmstadt, aiming at an accurate determination of QED corrections in the critical field limit via an accurate determination of the ground-state binding energy in a high-Z, H-like ion. Until now for H-like uranium, an accuracy of 1% could be reached in an experiment performed at the electron cooler, due to the deceleration capability of the ESR. A further improvement by almost one order of magnitude is envisaged by a transmission x-ray spectrometer setup in the FOcusing Compensated Asymmetric Laue (FOCAL) geometry, as well as by the implementation of high-resolution microcalorimeter devices.Here we report on the latest commissioning experiment of a two-arm transmission X-ray spectrometer, along with high-performance position-sensitive microstrip germanium detectors. Due to a photon efficiency of only 10{sup -8}, the position sensitivity, as well as the energy and time resolution of segmented solid-state germanium detectors, are absolutely essential for the experiment. In combination with the FOCAL spectrometer, these position-sensitive detectors permit the simultaneous measurement of all energies in the regime of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved argon microplasma diagnostics by diode laser absorption

Microplasmas were diagnosed by spatially resolved diode laser absorption using the Ar 801.4 nm transition (1s{sub 5}-2p{sub 8}). A 900 MHz microstrip split ring resonator was used to excite the microplasma which was operated between 100-760 Torr (13-101 kPa). The gas temperatures and the Ar 1s{sub 5} line-integrated densities were obtained from the atomic absorption lineshape. Spatially resolved data were obtained by focusing the laser to a 30 {mu}m spot and translating the laser path through the plasma with an xyz microdrive. At 1 atm, the microplasma has a warm core (850 K) that spans 0.2 mm and a steep gradient to room temperature at the edge of the discharge. At lower pressure, the gas temperature decreases and the spatial profiles become more diffuse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structural and magnetic properties of La{sub 0.7}Sr{sub 0.3}MnO{sub 3} thin films integrated onto Si(100) substrates with SrTiO{sub 3} as buffer layer

La{sub 0.7}Sr{sub 0.3}MnO{sub 3} (LSMO) thin films with a thickness d of 10, 20, 60, and 100 nm were grown on 20-nm-thick SrTiO{sub 3}-buffered (100) silicon substrates by a reactive molecular beam epitaxy. For all samples, x-ray diffraction (XRD) revealed an excellent epitaxy with in-plane cubic [100] and [010] axes of LSMO. The XRD measured values of the out-of-plane lattice parameter suggest that the strain state does not vary significantly from sample to sample. A super conducting quantum interference device reveals that the room temperature magnetization at saturation increases with d and nearly reaches the bulk value for d = 100 nm; the Curie temperature ranges in the 320-350 K interval, to compare to 360 K in the bulk. Ferromagnetic resonance (FMR) in cavity (at 9.5 GHz) and microstrip FMR used to investigate the dynamic magnetic properties, revealed a fourfold anisotropy showing its easy axes along the [110] and [110] directions. In the thickest samples (d > 20 nm), the FMR spectra present two distinct resonant modes. This splitting is presumably due to the simultaneous presence of two different magnetic phases.

36 MATERIALS SCIENCE↗

Mode conversion by symmetry breaking of propagating spin waves.

We study spin-wave transport in a microstructured Ni{sub 81}Fe{sub 19} waveguide exhibiting broken translational symmetry. We observe the conversion of a beam profile composed of symmetric spin-wave width modes with odd numbers of antinodes n = 1, 3,... into a mixed set of symmetric and asymmetric modes. Due to the spatial homogeneity of the exciting field along the used microstrip antenna, quantized spin-wave modes with an even number n of antinodes across the stripe's width cannot be directly excited. We show that a break in translational symmetry may result in a partial conversion of even spin-wave waveguide modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of propagating backward volume spin waves by phase-sensitive mode conversion in two-dimensional microstructures

We present the generation of propagating backward volume (BV) spin waves in a T shaped Ni{sub 81}Fe{sub 19} microstructure. These waves are created from counterpropagating Damon Eshbach spin waves, which are excited using microstrip antennas. By employing Brillouin light scattering microscopy, we show how the phase relation between the counterpropagating waves determines the mode generated in the center of the structure, and prove its propagation inside the longitudinally magnetized part of the T shaped microstructure. This gives access to the effective generation of backward volume spin waves with full control over the generated transverse mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Broadband calibrated scattering parameters characterization of a superconducting quantum interference device amplifier

In this work, we characterize the 2-port scattering parameters of a superconducting quantum interference device amplifier at {approx}20 mK over several gigahertz of bandwidth. The measurement reference plane is positioned on a 6.25 {Omega} microstrip line situated directly at the input and output of the device by means of a thru-reflect-line cryogenic calibration procedure. From the scattering parameters, we derive the device available power gain, isolation, and input impedance over the 2-8 GHz range. This measurement methodology provides a path towards designing wide-band matching circuits for low impedance superconducting amplifiers operating at dilution refrigerator temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The phase accumulation and antenna near field of microscopic propagating spin wave devices

We studied phase accumulation by the highly non-reciprocal magnetostatic surface spin waves in thin Permalloy microstripes excited and received by microscopic coplanar antennae. We find that the experimentally measured characteristic length of the near field of the antenna is smaller than the total width of the coplanar. This is confirmed by our numerical simulations. Consequently, the distance over which the spin wave accumulates its phase while travelling between the input and output antennae coincides with the distance between the antennae symmetry axes with good accuracy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Co{sub 2}FeAl Heusler thin films grown on Si and MgO substrates: Annealing temperature effect

10 nm and 50 nm Co{sub 2}FeAl (CFA) thin films have been deposited on MgO(001) and Si(001) substrates by magnetron sputtering and annealed at different temperatures. X-rays diffraction revealed polycrystalline or epitaxial growth (according to CFA(001)[110]//MgO(001)[100] epitaxial relation) for CFA films grown on a Si and on a MgO substrate, respectively. For these later, the chemical order varies from the A2 phase to the B2 phase when increasing the annealing temperature (T{sub a}), while only the A2 disorder type has been observed for CFA grown on Si. Microstrip ferromagnetic resonance (MS-FMR) measurements revealed that the in-plane anisotropy results from the superposition of a uniaxial and a fourfold symmetry term for CFA grown on MgO substrates. This fourfold anisotropy, which disappears completely for samples grown on Si, is in accord with the crystal structure of the samples. The fourfold anisotropy field decreases when increasing T{sub a}, while the uniaxial anisotropy field is nearly unaffected by T{sub a} within the investigated range. The MS-FMR data also allow for concluding that the gyromagnetic factor remains constant and that the exchange stiffness constant increases with T{sub a}. Finally, the FMR linewidth decreases when increasing T{sub a}, due to the enhancement of the chemical order. We derive a very low intrinsic damping parameter (1.1×10{sup −3} and 1.3×10{sup −3} for films of 50 nm thickness annealed at 615 °C grown on MgO and on Si, respectively)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Symmetric reflection line resonator and its quality factor modulation by a two-dimensional electron gas

We have designed and fabricated a half-wavelength reflection line resonator that consists of a pair of coupled microstrip lines on a GaAs/AlGaAs heterostructure. By changing the top gate voltage on a small square with a two-dimensional electron gas under the resonator, the quality factor was tuned over a large range from 2700 to below 600. Apart from being of fundamental interest, this gate modulation technique has the potential for use in on-chip resonator applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Localized parallel parametric generation of spin waves in a Ni{sub 81}Fe{sub 19} waveguide by spatial variation of the pumping field

We present the experimental observation of localized parallel parametric generation of spin waves in a transversally in-plane magnetized Ni{sub 81}Fe{sub 19} magnonic waveguide. The localization is realized by combining the threshold character of parametric generation with a spatially confined enhancement of the amplifying microwave field. The latter is achieved by modulating the width of the microstrip transmission line which is used to provide the pumping field. By employing microfocussed Brillouin light scattering spectroscopy, we analyze the spatial distribution of the generated spin waves and compare it with numerical calculations of the field distribution along the Ni{sub 81}Fe{sub 19} waveguide. This provides a local spin-wave excitation in transversally in-plane magnetized waveguides for a wide wave-vector range which is not restricted by the size of the generation area.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of horn antenna mixer array with internal local oscillator module for microwave imaging diagnostics

A new antenna array is proposed in order to improve the sensitivity and complexity of microwave imaging diagnostics systems such as a microwave imaging reflectometry, a microwave imaging interferometer, and an electron cyclotron emission imaging. The antenna array consists of five elements: a horn antenna, a waveguide-to-microstrip line transition, a mixer, a local oscillation (LO) module, and an intermediate frequency amplifier. By using an LO module, the LO optics can be removed, and the supplied LO power to each element can be equalized. We report details of the antenna array and characteristics of a prototype antenna array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large voltage-induced modification of spin-orbit torques in Pt/Co/GdOx

We report on large modifications of current-induced spin-orbit torques in a gated Pt/Co/Gd-oxide microstrip due to voltage-driven O{sup 2−} migration. The Slonczewski-like and field-like torques are quantified using a low-frequency harmonic technique based on the polar magneto-optical Kerr effect. Voltage-induced oxidation of Co enhances the Slonczewski-like torque by as much as an order of magnitude and simultaneously reduces the anisotropy energy barrier by a factor of ∼5. Such magneto-ionic tuning of interfacial spin-orbit effects may significantly enhance the efficiency of magnetization switching and provide additional degrees of freedom in spintronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗