Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Cation dopant distributions in nanostructures of transition-metal doped ZnO:Monte Carlo simulations

The path from trace doping to solid solution formation involves an intermediate regime in which the doping level is a few to several atomic percent. In this regime, dopant-dopant interactions, which are driven by the spatial arrangement of dopants, are critical factors in determining the resulting properties. Conventional wisdom counts on simple probabilistic methods for predicting dopant distributions. Here, we use Monte Carlo simulations to show that widely used, straightforward statistical models, such as that of Behringer1, are accurate only in the limit of infinitesimally small surface–to-volume ratio. For epitaxial films and nanoparticles, where much of the current interest resides, dopant distributions depend strongly on the surface-to-volume ratio. We present empirical expressions that accurately predict dopant bonding configurations as a function of film or particle size, shape and dopant concentration for doped ZnO, a material of particular interest in semiconductor spintronics.

36 MATERIALS SCIENCE↗

Dosimetric characterization of model Cs-1 Rev2 cesium-131 brachytherapy source in water phantoms and human tissues with MCNP5 Monte Carlo simulation

A recently developed alternative brachytherapy seed, Cs-1 Rev2 cesium-131, has begun to be used in clinical practice. The dosimetric characteristics of this source in various media, particularly in human tissues, have not been fully evaluated. The aim of this study was to calculate the dosimetric parameters for the Cs-1 Rev2 cesium-131 seed following the recommendations of the AAPM TG-43U1 report [Rivard et al., Med. Phys. 31, 633-674 (2004)] for new sources in brachytherapy applications. Dose rate constants, radial dose functions, and anisotropy functions of the source in water, Virtual Water, and relevant human soft tissues were calculated using MCNP5 Monte Carlo simulations following the TG-43U1 formalism. The results yielded dose rate constants of 1.048, 1.024, 1.041, and 1.044 cGy h{sup -1} U{sup -1} in water, Virtual Water, muscle, and prostate tissue, respectively. The conversion factor for this new source between water and Virtual Water was 1.02, between muscle and water was 1.006, and between prostate and water was 1.004. The authors' calculation of anisotropy functions in a Virtual Water phantom agreed closely with Murphy's measurements [Murphy et al., Med. Phys. 31, 1529-1538 (2004)]. Our calculations of the radial dose function in water and Virtual Water have good agreement with those in previous experimental and Monte Carlo studies. The TG-43U1 parameters for clinical applications in water, muscle, and prostate tissue are presented in this work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ab Initio Quantum Monte Carlo Simulation of the Warm Dense Electron Gas in the Thermodynamic Limit

Here we perform ab initio quantum Monte Carlo (QMC) simulations of the warm dense uniform electron gas in the thermodynamic limit. By combining QMC data with the linear response theory, we are able to remove finite-size errors from the potential energy over the substantial parts of the warm dense regime, overcoming the deficiencies of the existing finite-size corrections by Brown et al. [Phys. Rev. Lett. 110, 146405 (2013)]. Extensive new QMC results for up to N = 1000 electrons enable us to compute the potential energy V and the exchange-correlation free energy F xc of the macroscopic electron gas with an unprecedented accuracy of | Δ V | / | V | , | Δ F xc | / | F | xc ~ 10 $-$3 . Finally, a comparison of our new data to the recent parametrization of F xc by Karasiev et al. [Phys. Rev. Lett. 112, 076403 (2014)] reveals significant deviations to the latter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Treatment planning for a small animal using Monte Carlo simulation

The development of a small animal model for radiotherapy research requires a complete setup of customized imaging equipment, irradiators, and planning software that matches the sizes of the subjects. The purpose of this study is to develop and demonstrate the use of a flexible in-house research environment for treatment planning on small animals. The software package, called DOSCTP, provides a user-friendly platform for DICOM computed tomography-based Monte Carlo dose calculation using the EGSnrcMP-based DOSXYZnrc code. Validation of the treatment planning was performed by comparing the dose distributions for simple photon beam geometries calculated through the Pinnacle3 treatment planning system and measurements. A treatment plan for a mouse based on a CT image set by a 360-deg photon arc is demonstrated. It is shown that it is possible to create 3D conformal treatment plans for small animals with consideration of inhomogeneities using small photon beam field sizes in the diameter range of 0.5-5 cm, with conformal dose covering the target volume while sparing the surrounding critical tissue. It is also found that Monte Carlo simulation is suitable to carry out treatment planning dose calculation for small animal anatomy with voxel size about one order of magnitude smaller than that of the human.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays

Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10x10 cm{sup 2} field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and 1 mm lead filters, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two schemes for quantitative photoacoustic tomography based on Monte Carlo simulation

Purpose: The aim of this study was to develop novel methods for photoacoustically determining the optical absorption coefficient of biological tissues using Monte Carlo (MC) simulation. Methods: In this study, the authors propose two quantitative photoacoustic tomography (PAT) methods for mapping the optical absorption coefficient. The reconstruction methods combine conventional PAT with MC simulation in a novel way to determine the optical absorption coefficient of biological tissues or organs. Specifically, the authors’ two schemes were theoretically and experimentally examined using simulations, tissue-mimicking phantoms, ex vivo, and in vivo tests. In particular, the authors explored these methods using several objects with different absorption contrasts embedded in turbid media and by using high-absorption media when the diffusion approximation was not effective at describing the photon transport. Results: The simulations and experimental tests showed that the reconstructions were quantitatively accurate in terms of the locations, sizes, and optical properties of the targets. The positions of the recovered targets were accessed by the property profiles, where the authors discovered that the off center error was less than 0.1 mm for the circular target. Meanwhile, the sizes and quantitative optical properties of the targets were quantified by estimating the full width half maximum of the optical absorption property. Interestingly, for the reconstructed sizes, the authors discovered that the errors ranged from 0 for relatively small-size targets to 26% for relatively large-size targets whereas for the recovered optical properties, the errors ranged from 0% to 12.5% for different cases. Conclusions: The authors found that their methods can quantitatively reconstruct absorbing objects of different sizes and optical contrasts even when the diffusion approximation is unable to accurately describe the photon propagation in biological tissues. In particular, their methods are able to resolve the intrinsic difficulties that occur when quantitative PAT is conducted by combining conventional PAT with the diffusion approximation or with radiation transport modeling.

60 APPLIED LIFE SCIENCES↗

A DFT-based kinetic Monte Carlo simulation of multiphase oxide-metal thin film growth

Functional thin films of nanoscale metal pillars in oxide or nitride matrices known as vertically aligned nanocomposite (VAN) have gained much interest owing to their unique strain-coupled and highly anisotropic properties. So far, the deposition of these films has been explored mostly experimentally. In this work, a density functional theory (DFT)-based kinetic Monte Carlo simulation model using Bortz–Kalos–Lebowitz algorithm was developed to understand the growth of VAN films deposited by pulsed laser technique on mismatching substrates. The model has been parameterized and applied to understand the kinetics of growth thin films consisting of Au pillars in CeO2 matrix deposited on SrTiO3 substrates. The effects of pulsed laser deposition (PLD) conditions including the pulse frequency, deposition flux, and substrate temperature were explored. The simulations indicate that the Au pillar size and shape exhibit significant dependence on the PLD conditions. Namely, increasing the temperature increases the average pillar size and lowers the pillar density, and vice versa. In addition, the simulations revealed that increasing the deposition rate results in lowering the average pillar size and increasing the density. Particularly, the DFT results suggest that Au pillar size can be tuned during the initial growth of the first monolayer due to the significantly low activation barrier. Our analysis showed that the relationship between the average pillar size and pillar density is influenced by the kinetics. Furthermore, autocorrelation analysis showed that pillars self-organize in quasi-ordered patterns at certain windows of the deposition conditions, which is attributed to the complex nature of the chemical interactions in the system, the kinetics, and the deposition parameters.

Physics↗

Monte Carlo Simulations of Neutron Resonance Transmission Analysis with the Dense Plasma Focus

Simulations were performed using the Monte Carlo radiation transport code MCNP in order to analyze the feasibility of using a dense plasma focus to perform neutron resonance transmission analysis. It was found that the dense plasma focus is well-suited for neutron resonance transmission analysis because of the relatively short pulse duration and large neutron yield. This makes lowenergy neutron spectroscopy using time of flight much more accurate, allowing for more detailed assays of smaller quantities of special nuclear material.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-T-679: Monte Carlo Simulation On Surface Dose in Preclinical Irradiation Using Monoenergetic Photon Beams

Purpose: This study investigated the surface dose variation in preclinical irradiation using small animal, when monoenergetic photon beams with energy range from 50 keV to 1.25 MeV were used. Methods: Inhomogeneous, homogeneous and bone-tissue homogeneous mouse phantom based on the same CT image set were used. The homogeneous and bone-tissue homogeneous phantom were created with the relative electron density of all and only bone voxels of the mouse overridden to one, respectively. Monte Carlo simulation based on the EGSnrc-based code was used to calculate the surface dose, when the phantoms were irradiated by a 360° photon arc with energies ranging from 50 keV to 1.25 MeV. The mean surface doses of the three phantoms were calculated. In addition, the surface doses from partial arcs, 45°–315°, 125°–225°, 45°–125° and 225°–315° covering the anterior, posterior, right lateral and left lateral region of the mouse were determined using different photon beam energies. Results: When the prescribed dose at the isocenter of the mouse was 2 Gy, the maximum mean surface doses, found at the 50-keV photon beams, were 0.358 Gy, 0.363 Gy and 0.350 Gy for the inhomogeneous, homogeneous and bone-tissue homogeneous mouse phantom, respectively. The mean surface dose of the mouse was found decreasing with an increase of the photon beam energy. For surface dose in different orientations, the lateral regions of the mouse were receiving lower dose than the anterior and posterior regions. This may be due to the increase of beam attenuation along the horizontal (left-right) axis than the vertical (anterior-posterior) in the mouse. Conclusion: It is concluded that consideration of phantom inhomogeneity in the dose calculation resulted in a lower mean surface dose of the mouse. The mean surface dose also decreased with an increase of photon beam energy in the kilovoltage range.

60 APPLIED LIFE SCIENCES↗

Potential use of P-32 ophthalmic applicator: Monte Carlo simulations for design and dosimetry

Postoperative {beta}-irradiation after pterygium excision has been considered a valuable therapeutic procedure to reduce the recurrence rate. Recently, it was reported that {beta}-irradiation also substantially reduced the risk of surgical failure after glaucoma surgery. Pure {beta}-irradiation using a {sup 90}Sr/Y applicator has been almost exclusively used for this purpose. As an alternative to {sup 90}Sr/Y {beta}-irradiation, we propose treatment with betas of a {sup 32}P source. While {sup 32}P has a lower maximum energy (1.71 MeV) than {sup 90}Sr/Y (2.27 MeV), it has an average energy comparable to that of {sup 90}Sr/Y. Furthermore, it can be produced easily in a nuclear reactor by neutron activation and is considered a less hazardous material. Monte Carlo simulations for the dosimetry of proposed {sup 32}P applicators were performed using the MCNP5 code. The structure and dimension of the {sup 32}P applicators were based on those of the {sup 90}Sr/Y applicators currently available, while medical plastic encapsulation and liquid source were chosen to enhance {beta}-dose to the surface of the conjunctiva. The {sup 32}P applicator showed that the surface dose distribution (up to 0.75 mm depth) is very similar to that of {sup 90}Sr/Y. However, beyond 0.75 mm depth, the {sup 32}P doses decrease with depths more rapidly than {sup 90}Sr/Y doses. In order to achieve the same surface dose rate, the required {sup 32}P activity is about three times that for a {sup 90}Sr/Y applicator. We conclude that the proposed {sup 32}P applicator can deliver therapeutic doses to the target lesion while sparing the lens better than the {sup 90}Sr/Y applicator. The {sup 32}P activity required to deliver therapeutic doses can be produced in a 30 MW reactor available at the Korea Atomic Energy Research Institute.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Investigation and Monte Carlo Simulation of Quasielastic Electron Scattering From Helium-3 Clusters in Helium-4

Experiment E04-018 was conducted in Hall A of the Jefferson National Laboratory (JLab) from November 2006 through July 2007. The experiment used the two superconducting, high-resolution magnetic spectrometers of Hall A to detect scattered electrons and recoil nuclei. One goal of this experiment was to provide accurate data on the elastic charge form factor of 4He to high momentum transfers (up to Q2 = 77 fm?2). The purpose of this thesis is to analyze and simulate a very unique and unexpected class of data from this experiment. The work performed involved the analysis of electron scattering data with the 4He target of the JLab E04-018 experiment and Monte Carlo simulation studies of elastic and quasielastic electron scattering from the 4He and 3He few-body nuclear systems. The results of this experiment and the simulations provide insights into the existence of A = 3 clustering in 4He, and possibly in heavier nuclei.

Alahmade, Walaa↗

Vapor phase nucleation of the short-chain n -alkanes ( n -pentane, n -hexane and n -heptane): Experiments and Monte Carlo simulations

We measured the nucleation rates of n-pentane through n-heptane in a supersonic nozzle at temperatures ranging from ca. 109 K to 168 K. For n-pentane and n-hexane, these are the first nucleation rate measurements that have been made, and the trends in the current data agree well with those in the earlier work of Ghosh et al. for longer chain alkanes. Complementary Monte Carlo simulations, using the transferable potentials for phase equilibria-united atom potentials, suggest that despite the high degree of supercooling, the critical clusters remain liquid like under experimental conditions for n-pentane through n-heptane, but adopt more ordered structures for n-octane and n-nonane. For all three alkanes, the experimental and simulated nucleation rates are offset by ~3 orders of magnitude when plotted as a function of ln S/(T c /T – 1) 1.5 . Explicitly accounting for the surface tension difference between the real and model substances, or alternatively using the Hale scaling parameter, Ω, consistent with the model potential, increases the offset to ~6 orders of magnitude.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar Wind Implantation Into the Lunar Regolith: Monte Carlo Simulations of H Retention in a Surface With Defects and the H2 Exosphere

The solar wind implants protons into the top 20–30 nm of lunar regolith grains, and the implanted hydrogen will diffuse out of the regolith but also interact with oxygen in the regolith oxides. We apply a statistical approach to estimate the diffusion of hydrogen in the regolith hindered by forming temporary bonds with regolith oxygen atoms. A Monte Carlo simulation was used to track the temporal evolution of bound OH surface content and the H2 exosphere. The model results are consistent with the interpretation of the Chandrayaan‐1 M3 observations of infrared absorption spectra by surface hydroxyls as discussed in Li and Milliken (2017, https://doi.org/10.1126/sciadv.1701471). The model reproduced the latitudinal concentration of OH by using a Gaussian energy distribution of f(U(sub 0) = 0.5 eV, U(sub W) = 0.078–0.1 eV) to characterize the activation energy barrier to the diffusion of hydrogen in space weathered regolith. In addition, the model results of the exospheric content of H2 are consistent with observations by the Lyman Alpha Mapping Project on the Lunar Reconnaissance Orbiter. Therefore, we provide support for hydroxyl formation by chemically trapped solar wind protons.

Tucker, O. J.↗

Solar Wind Implantation Into the Lunar Regolith: Monte Carlo Simulations of H Retention in a Surface With Defects and the H2 Exosphere

The solar wind implants protons into the top 20–30 nm of lunar regolith grains, and the implanted hydrogen will diffuse out of the regolith but also interact with oxygen in the regolith oxides. We apply a statistical approach to estimate the diffusion of hydrogen in the regolith hindered by forming temporary bonds with regolith oxygen atoms. A Monte Carlo simulation was used to track the temporal evolution of bound OH surface content and the H2 exosphere. The model results are consistent with the interpretation of the Chandrayaan-1 M3 observations of infrared absorption spectra by surface hydroxyls as discussed in Li and Milliken (2017). Themodel reproduced the latitudinal concentration of OH by using a Gaussian energy distribution of f(U(o) = 0.5eV, U(w) = 0.078 – 0.1 eV) to characterize the activation energy barrier to the diffusion of hydrogen in space weathered regolith. In addition, the model results of the exospheric content of H2 are consistent with observations by the Lyman Alpha Mapping Project on the Lunar Reconnaissance Orbiter. Therefore, we provide support for hydroxyl formation by chemically trapped solar wind protons.

O. J. Tucker↗

Solar Wind Implantation Into the Lunar Regolith: Monte Carlo Simulations of H Retention in a Surface With Defects and the H2 Exosphere

The solar wind implants protons into the top 20–30 nm of lunar regolith grains, and the implanted hydrogen will diffuse out of the regolith but also interact with oxygen in the regolith oxides. We apply a statistical approach to estimate the diffusion of hydrogen in the regolith hindered by forming temporary bonds with regolith oxygen atoms. A Monte Carlo simulation was used to track the temporal evolution of bound OH surface content and the H2 exosphere. The model results are consistent with the interpretation of the Chandrayaan‐1 M3 observations of infrared absorption spectra by surface hydroxyls as discussed in Li and Milliken (2017, https://doi.org/10.1126/sciadv.1701471). The model reproduced the latitudinal concentration of OH by using a Gaussian energy distribution of f(U0 = 0.5 eV, UW = 0.078–0.1 eV) to characterize the activation energy barrier to the diffusion of hydrogen in space weathered regolith. In addition, the model results of the exospheric content of H2 are consistent with observations by the Lyman Alpha Mapping Project on the Lunar Reconnaissance Orbiter. Therefore, we provide support for hydroxyl formation by chemically trapped solar wind protons.

O J Tucker↗

Exploring the Great Pyramid: Stand-Alone Monte Carlo Simulations for Detector Optimization

Cosmic-ray muon imaging has been used to non-destructively examine the Pyramids of Khufu and Khafre on the Giza Plateau; the EGP project will continue this line of research by undertaking a full tomographic scan of the former and, in doing so, will increase the sensitivity of the technique by upwards of two orders of magnitude. This paper details the development of stand-alone Monte Carlo simulations intended to aid in optimizing the EGP detector system. While the rectangular scintillator model considered here does provide sucient position resolution in a few specic test cases, it is not the optimal telescope design. An attempted detector modication to permit tagging of muons by their incident momenta is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinetic Monte Carlo Simulation of Oxygen Diffusion in Ytterbium Disilicate

Ytterbium disilicate is of interest as a potential environmental barrier coating for aerospace applications, notably for use in next generation jet turbine engines. In such applications, the transport of oxygen and water vapor through these coatings to the ceramic substrate is undesirable if high temperature oxidation is to be avoided. In an effort to understand the diffusion process in these materials, we have performed kinetic Monte Carlo simulations of vacancy-mediated and interstitial oxygen diffusion in Ytterbium disilicate. Oxygen vacancy and interstitial site energies, vacancy and interstitial formation energies, and migration barrier energies were computed using Density Functional Theory. We have found that, in the case of vacancy-mediated diffusion, many potential diffusion paths involve large barrier energies, but some paths have barrier energies smaller than one electron volt. However, computed vacancy formation energies suggest that the intrinsic vacancy concentration is small. In the case of interstitial diffusion, migration barrier energies are typically around one electron volt, but the interstitial defect formation energies are positive, with the result that the disilicate is unlikely to exhibit experience significant oxygen permeability except at very high temperature.

Coatings↗

Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

Purpose: The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using {sup 60}Co or {sup 192}Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference man defined in ICRP Publication 89. Point sources of {sup 60}Co or {sup 192}Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate, and equivalent doses per clinical absorbed dose in this target organ were obtained in several radiosensitive organs. Values were corrected to account for clinical circumstances with the source located at various positions with differing dwell times throughout the prostate. This was repeated for a homogeneous water phantom. Results: For the nearest organs considered (bladder, rectum, testes, small intestine, and colon), equivalent doses given by {sup 60}Co source were smaller (8%-19%) than from {sup 192}Ir. However, as the distance increases, the more penetrating gamma rays produced by {sup 60}Co deliver higher organ equivalent doses. The overall result is that effective dose per clinical absorbed dose from a {sup 60}Co source (11.1 mSv/Gy) is lower than from a {sup 192}Ir source (13.2 mSv/Gy). On the other hand, equivalent doses were the same in the tissue and the homogeneous water phantom for those soft tissues closer to the prostate than about 30 cm. As the distance increased, the differences of photoelectric effect in water and soft tissue, and appearance of other materials such as air, bone, or lungs, produced variations between both phantoms which were at most 35% in the considered organ equivalent doses. Finally, effective doses per clinical absorbed dose from IMRT and proton therapy were comparable to those from both brachytherapy sources, with brachytherapy being advantageous over external beam radiation therapy for the furthest organs. Conclusions: A database of organ equivalent doses when applying HDR brachytherapy to the prostate with either {sup 60}Co or {sup 192}Ir is provided. According to physical considerations, {sup 192}Ir is dosimetrically advantageous over {sup 60}Co sources at large distances, but not in the closest organs. Damage to distant healthy organs per clinical absorbed dose is lower with brachytherapy than with IMRT or protons, although the overall effective dose per Gy given to the prostate seems very similar. Given that there are several possible fractionation schemes, which result in different total amounts of therapeutic absorbed dose, advantage of a radiation treatment (according to equivalent dose to healthy organs) is treatment and facility dependent.

60 APPLIED LIFE SCIENCES↗