Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Experience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

ATCA-based ATLAS FTK input interface system

The first stage of the ATLAS Fast TracKer (FTK) is an ATCA-based input interface system, where hits from the entire silicon tracker are clustered and organized into overlapping eta-phi trigger towers before being sent to the tracking engines. First, FTK Input Mezzanine cards receive hit data and perform clustering to reduce data volume. Then, the ATCA-based Data Formatter system will organize the trigger tower data, sharing data among boards over full mesh backplanes and optic fibers. The board and system level design concepts and implementation details, as well as the operation experiences from the FTK full-chain testing, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics

The Phase I upgrade of the CMS Hadron Endcap Calorimeters consists of new photodetectors (Silicon Photomultipliers in place of Hybrid Photo-Diodes) and front-end electronics. The upgrade will eliminate the noise and the calibration drift of the Hybrid Photo-Diodes and enable the mitigation of the radiation damage of the scintillators and the wavelength shifting fibers with a larger spectral acceptance of the Silicon Photomultipliers. The upgrade also includes increased longitudinal segmentation of the calorimeter readout, which allows pile-up mitigation and recalibration due to depth-dependent radiation damage. As a realistic operational test, the responses of the Hadron Endcap Calorimeter wedges were calibrated with a $^{60}$Co radioactive source with upgrade electronics. The test successfully established the procedure for future source calibrations of the Hadron Endcap Calorimeters. Lastly we describe the instrumentation details and the operational experiences related to the sourcing test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DAQ and control system for the CMS Phase-1 pixel detector upgrade

In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Neutrino Scattering Events with Low Hadronic Recoil to Inform Neutrino Flux and Detector Energy Scale

Charged-current neutrino interactions with low hadronic recoil ("low-nu") have a cross-section that is approximately constant versus neutrino energy. These interactions have been used to measure the shape of neutrino fluxes as a function of neutrino energy at accelerator-based neutrino experiments such as CCFR, NuTeV, MINOS and MINERvA. In this paper, we demonstrate that low-nu events can be used to measure parameters of neutrino flux and detector models and that utilization of event distributions over the upstream detector face can discriminate among parameters that affect the neutrino flux model. From fitting a large sample of low-nu events obtained by exposing MINERvA to the NuMI medium-energy beam, we find that the best-fit flux parameters are within their a priori uncertainties, but the energy scale of muons reconstructed in the MINOS detector is shifted by 3.6% (or 1.8 times the a priori uncertainty on that parameter). These fit results are now used in all MINERvA cross-section measurements, and this technique can be applied by other experiments operating at MINERvA energies, such as DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

43 PARTICLE ACCELERATORS↗

Spallation Neutron Source Hydrogen Relief Analysis for the Cryogenic Moderator System

The Spallation Neutron Source at Oak Ridge National Laboratory operates the Cryogenic Moderator System (CMS) which provides hydrogen cooling at 20K to three neutron moderators. Each hydrogen loop is protected by multiple burst discs and reclosing relief valves. As a result of the Proton Power Upgrade project, the CMS moderator loops will hold more hydrogen and thus require piping modifications. Operational experience has demonstrated that transient pressure increases in these hydrogen loops occasionally result in the rupture of the burst discs. The causes for pressure transients in the system that might lead to hydrogen venting are varied and complex, for example loss of vacuum or cooling. Dynamic simulation and analysis of the parameters considered as the worst-case relief venting scenario were performed and will be presented.

47 OTHER INSTRUMENTATION↗

Skipper Charge-Coupled Device for Low-Energy-Threshold Particle Experiments above Ground

Here we present experimental results using a single-electron resolution skipper CCD running above ground level to demonstrate the potential of this technology for its use in reactor neutrino observations and other low-energy particle-interaction experiments. Operating conditions and event-selection criteria are provided to decouple most of the background rate at low energies. The majority of this background comes from interactions in the inactive silicon surrounding the active detector volume that ends up in the readout register of the sensor. Our final results are compared with other low-threshold technologies showing a good control of the background for low ionization energies down to five electron-hole pairs. This demonstrates that the skipper CCD proves to be among the best options to measure low-energy and weakly interacting particles at ground level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of the calorimetric and kinematic methods of neutrino energy reconstruction in disappearance experiments

To be able to achieve their physics goals, future neutrino-oscillation experiments will need to reconstruct the neutrino energy with very high accuracy. In this work, we analyze how the energy reconstruction may be affected by realistic detection capabilities, such as energy resolutions, efficiencies, and thresholds. This allows us to estimate how well the detector performance needs to be determined a priori in order to avoid a sizable bias in the measurement of the relevant oscillation parameters. We compare the kinematic and calorimetric methods of energy reconstruction in the context of two ν μ → ν μ disappearance experiments operating in different energy regimes. For the calorimetric reconstruction method, we find that the detector performance has to be estimated with an O(10%) accuracy to avoid a significant bias in the extracted oscillation parameters. Thus, in the case of kinematic energy reconstruction, we observe that the results exhibit less sensitivity to an overestimation of the detector capabilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for e + e - → γ η c ( 1 S ) at center-of-mass energies between 4.01 and 4.60 GeV

In this paper, we present first evidence for the process e + e - → γη c (1S) at six center-of-mass energies between 4.01 and 4.60 GeV using data collected by the BESIII experiment operating at BEPCII. We measure the Born cross section at each energy using a combination of twelve η c (1S) decay channels. We also combine all six energies under various assumptions for the energy-dependence of the cross section. Finally, if the process is assumed to proceed via the Y (4260), we measure a peak Born cross section σ peak (e + e - → γη c (1S)) = 2.11 ± 0.49(stat.) ± 0.36(syst.) pb with a statistical significance of 4.2σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sustained Neutron Production from a Sheared-Flow Stabilized Z Pinch

The sheared-flow stabilized Z pinch has demonstrated long-lived plasmas with fusion-relevant parameters. Here we present the first experimental results demonstrating sustained, quasi-steady-state neutron production from the fusion Z -pinch experiment, operated with a mixture of 20% deuterium/80% hydrogen by pressure. Neutron emissions lasting approximately 5 μs are reproducibly observed with pinch currents of approximately 200 kA during an approximately 16 μs period of plasma quiescence. The average neutron yield is estimated to be ( 1.25 ± 0.45 ) x 10 5 neutrons / pulse and scales with the square of the deuterium concentration. Coincident with the neutron signal, plasma temperatures of 1–2 keV and densities of approximately 10 17 cm -3 with 0.3 cm pinch radii are measured with fully integrated diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the Antineutrino Spectrum from U 235 Fission at HFIR with PROSPECT

This Letter reports the first measurement of the 235 U ν¯ e energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW th highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678 ± 304 (stat.) ν¯ e -induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to 235 U. Despite broad agreement, comparison of the Huber 235 U model to the measured spectrum produces a χ 2 /ndf = 51.4/31, driven primarily by deviations in two localized energy regions. As a result, the measured 235 U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the ν¯ e energy region of 5-7MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Machine-learning-assisted automation of single-crystal neutron diffraction

Neutron scattering is a powerful but expensive technique to study materials and discover new matter. Advanced detector technology has significantly improved the efficiency of neutron experiments, increasing the complexity of neutron data reduction and analysis. Machine learning (ML) brings new directions for neutron diffraction data reduction and experiment operation. Here, this work presents an ML-assisted data reduction and analysis method for precise recognition of Bragg peaks and the corresponding regions of interest; it can then automatically screen and align a measured crystal using the recognized peaks, and subsequently plan and optimize the data collection with user-provided information and uncertainty quantification values of detected peaks. This method shows robust performance in different complex sample environments and enables automated single-crystal neutron diffraction.

47 OTHER INSTRUMENTATION↗

Performance optimization of a bendable parabolic cylinder collimating X-ray mirror for the ALS micro-XAS beamline 10.3.2

The Advanced Light Source (ALS) beamline (BL) 10.3.2 is an apparatus for X-ray microprobe spectroscopy and diffraction experiments, operating in the energy range 2.4–17 keV. The performance of the beamline, namely the spatial and energy resolutions of the measurements, depends significantly on the collimation quality of light incident on the monochromator. In the BL 10.3.2 end-station, the synchrotron source is imaged 1:1 onto a set of roll slits which form a virtual source. The light from this source is collimated in the vertical direction by a bendable parabolic cylinder mirror. Details are presented of the mirror design, which allows for precision assembly, alignment and shaping of the mirror, as well as for extending of the mirror operating lifetime by a factor of ~10. Assembly, mirror optimal shaping and preliminary alignment were performed ex situ in the ALS X-ray Optics Laboratory (XROL). Using an original method for optimal ex situ characterization and setting of bendable X-ray optics developed at the XROL, a root-mean-square (RMS) residual surface slope error of 0.31 µrad with respect to the desired parabola, and an RMS residual height error of less than 3 nm were achieved. Once in place at the beamline, deviations from the designed optical geometry ( e.g. due to the tolerances for setting the distance to the virtual source, the grazing incidence angle, the transverse position) and/or mirror shape ( e.g. due to a heat load deformation) may appear. Due to the errors, on installation the energy spread from the monochromator is typically a few electron-volts. Here, a new technique developed and successfully implemented for at-wavelength ( in situ ) fine optimal tuning of the mirror, enabling us to reduce the collimation-induced energy spread to ~0.05 eV, is described.

43 PARTICLE ACCELERATORS↗

Commissioning and performance of the ATLAS transition radiation tracker with first high energy pp and Pb-Pb collisions at LHC

The ATLAS Transition Radiation Tracker (TRT) is the outermost of the three sub-systems of the ATLAS Inner Detector at the Large Hadron Collider at CERN. It consists of close to 300000 thin-wall drift tubes (straws) providing on average 30 two-dimensional space points with 0.12-0.15 mm resolution for charged particle tracks with |{eta}| < 2 and pt > 0.5 GeV. Along with continuous tracking, it provides particle identification capability through the detection of transition radiation X-ray photons generated by high velocity particles in the many polymer fibers or films that fill the spaces between the straws. Custom-built analog and digital electronics is optimized to operate as luminosity increases to the LHC design. In this article, a review of the commissioning and first operational experience of the TRT detector will be presented. Emphasis will be given to performance studies based on the reconstruction and analysis of LHC collisions. The first studies of the TRT detector response to the extremely high track density conditions during the November 2010 heavy ion LHC running period will be presented. These studies give interesting insight to the expected performance of the TRT in future high luminosity LHC proton-proton runs. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Generic Communication Protocol for Remote Laboratories: an Implementation on e-lab

The remote laboratories at IST (Instituto Superior Tecnico), e-lab, serve as a valuable tool for education and training based on remote control technologies. Due to the high number and increase of remotely operated experiments a generic protocol was developed to perform the communication between the software driver and the respective experimental setup in an easier and more unified way. The training in these fields of students and personnel can take advantage of such infrastructure with the purpose of deploying new experiments in a faster way. More than 10 experiments using the generic protocol are available on-line in a 24 x 7 way. (authors)

99 GENERAL AND MISCELLANEOUS↗

AN UPDATE ON NIF PULSED POWER

The National Ignition Facility (NIF) is a 192-beam laser fusion driver operating at Lawrence Livermore National Laboratory. NIF relies on three large-scale pulsed power systems to achieve its goals: the Power Conditioning Unit (PCU), which provides flashlamp excitation for the laser's injection system; the Power Conditioning System (PCS), which provides the multi-megajoule pulsed excitation required to drive flashlamps in the laser's optical amplifiers; and the Plasma Electrode Pockels Cell (PEPC), which enables NIF to take advantage of a fourpass main amplifier. Years of production, installation, and commissioning of the three NIF pulsed power systems are now complete. Seven-day-per-week operation of the laser has commenced, with the three pulsed power systems providing routine support of laser operations. We present the details of the status and operational experience associated with the three systems along with a projection of the future for NIF pulsed power.

42 ENGINEERING↗

Energy scan of cross sections for e{sup +}e{sup –} annihilation into quarkonia and light hadrons in the Belle experiment

The cross sections of the reactions e{sup +}e{sup –} → ϒ(nS)π{sup +}π{sup −} (n = 1, 2,3) and e{sup +}e{sup –} → h{sub b}(nP)π{sup +}π{sup −} (n = 1, 2) are measured as a function of the cms collision energy from their thresholds up to 11.02 GeV using the data of the Belle experiment operating at the KEKB e{sup +}e{sup –} collider. The peaks of the ϒ(10 860) and ϒ(11020) resonances are observed in the cross sections with an insignificant contribution of the continuum. The decay ϒ(11020) → h{sub b}(nP)π{sup +}π{sup −} is found to fully proceed through intermediate isovector states Z{sub b}(10610) and Z{sub b}(10650).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗