Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Use of the quartz crystal microbalance to determine the monomeric friction coefficient of polyimides

When a thin film of polymer is coated on to a quartz crystal microbalance (QCM), the QCM can be used to detect the rate of increase in weight of the polymer film as the volatile penetrant diffuses into the polymer. From this rate information the diffusion coefficient of the penetrant into the polymer can be computed. Calculations requiring this diffusion coefficient lead to values which approximate the monomeric friction coefficient of the polymer. This project has been concerned with the trial of crystal oscillating circuits suitable for driving polymer coated crystals in an atmosphere of penetrant. For these studies done at room temperature, natural rubber was used as an easily applied polymer that is readily penetrated by toluene vapors, qualities anticipated with polyimides when they are tested at T(g) in the presence of toluene. Three quartz crystal oscillator circuits were tested. The simplest circuit used +/- 5 volt dc and had a transistor to transistor logic (TTL) inverter chip that provides a 180 deg phase shift via a feed back loop. This oscillator circuit was stable but would not drive the crystal when the crystal was coated with polymer and subjected to toluene vapors. Removal of a variable resistor from this circuit increased stability but did not otherwise increase performance. Another driver circuit tested contained a two stage differential input, differential output, wide band video amplifier and also contain a feed back loop. The circuit voltage could not be varied and operated at +/- 5 volts dc; this circuit was also stable but failed to oscillate the polymer coated crystal in an atmosphere saturated with toluene vapors. The third oscillator circuit was of similar construction and relied on the same video amplifier but allowed operation with variable voltage. This circuit would drive the crystal when the crystal was submerged in liquid toluene and when the crystal was coated with polymer and immersed in toluene vapors. The frequency readings obtained when using this oscillating circuit are highly variable. This circuit requires further modification to stabilize frequency readings before its use in studies to determine the diffusion coefficient of penetrant molecules into a polymer film coated on a QCM.

Bechtold, Mary M.↗

The Direct Digital Modulation of Traveling Wave Tubes

Traveling wave tube (TWT) technology, first described by Rudolf Kompfner in the early 1940s, has been a key component of space missions from the earliest communication satellites in the 1960s to the Cassini probe today. TWTs are essentially signal amplifiers that have the special capability of operating at microwave frequencies. The microwave frequency range, which spans from approximately 500 MHz to 300 GHz, is shared by many technologies including cellular phones, satellite television, space communication, and radar. TWT devices are superior in reliability, weight, and efficiency to solid-state amplifiers at the high power and frequency levels required for most space missions. TWTs have three main components -an electron gun, slow wave structure, and collector. The electron gun generates an electron beam that moves along the length of the tube axis, inside of the slow wave circuit. At the same time, the inputted signal is slowed by its travel through the coils of the helical slow wave circuit. The interaction of the electron beam and this slowed signal produces a transfer of kinetic energy to the signal, and in turn, amplification. At the end of its travel, the spent electron beam moves into the collector where its remaining energy is dissipated as heat or harnessed for reuse. TWTs can easily produce gains in the tens of decibels, numbers that are suitable for space missions. To date, however, TWTs have typically operated at fixed levels of gain. This gain is determined by various, unchanging, physical factors of the tube. Traditionally, to achieve varying gain, an input signal s amplitude has had to first be modulated by a separate device before being fed into the TWT. This is not always desirable, as significant distortion can occur in certain situations. My mentor, Mr. Dale Force, has proposed an innovative solution to this problem called direct digital modulation . The testing and implementation of this solution is the focus of my summer internship. The direct digital modulation of a TWT removes the need for a separate amplitude modulation device. Instead, different levels of gain are achieved by varying the electron beam current. The lower the current, the less kinetic energy is available to be transferred to the signal. To vary the current, a grid is placed in-between the electron gun and the slow wave circuit. By changing the voltage across the grid, the electron beam current can be controlled. Grid technology has mostly been used in pulse applications such as radar, where only two voltage states are necessary. For direct digital modulation, however, a continuous range of voltages is required.

Radhamohan, Ranjan S.↗

Strain-retardant coherent perovskite phase stabilized Ni-rich cathode

The use of state-of-the-art Ni-rich layered oxides (LiNi x Co y Mn 1-x-y O 2 , x > 0.5) as the cathode material for lithium-ion batteries can push the energy and power density to a higher level than is currently available. However, volume variation associated with anisotropic lattice strain and stress that is being developed during lithium (de) intercalation induces severe structural instability and electrochemical decay of the cathode materials, which is amplified further when the battery is operating at a high voltage (above 4.5 V), which is essential for unlocking its high energy. Even after much effort by the research community, an intrinsic strain-retardant method for directly alleviating the continuous accumulation of lattice strain remains elusive. By introducing a coherent perovskite phase into the layered structure functioning as a ‘rivet’, we significantly mitigate the pernicious structural evolutions by a pinning effect. The lattice strain evolution in every single cycle is markedly reduced by nearly 70% when compared with conventional materials, which significantly enhances morphological integrity leading to a notable improvement in battery cyclability. This strain-retardant approach broadens the perspective for lattice engineering to release the strain raised from lithium (de)intercalation and paves the way for the development of high-energy-density cathodes with long durability.

25 ENERGY STORAGE↗

Improving the maximum transmission distance of continuous-variable quantum key distribution using a noiseless amplifier

We show that the maximum transmission distance of continuous-variable quantum key distribution in presence of a Gaussian noisy lossy channel can be arbitrarily increased using a heralded noiseless linear amplifier. We explicitly consider a protocol using amplitude and phase modulated coherent states with reverse reconciliation. Assuming that the secret key rate drops to zero for a line transmittance T{sub lim}, we find that a noiseless amplifier with amplitude gain g can improve this value to T{sub lim}/g{sup 2}, corresponding to an increase in distance proportional to log g. We also show that the tolerance against noise is increased.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An innovative SR-WEC for a market-disruptive LCOE

The objective of DE-EE0008630: An innovative SR-WEC for a market-disruptive LCOE was to develop and test a scaled prototype of the Surface-Riding Wave Energy Converter that can result in a market-disruptive Levelized Cost of Energy by a combination of an extended operating window, substantially lowered cost and amplified average power output by simple optimum control. Initially conceptualized as a floating linear electrical generator (LEG), the SR-WEC evolved into an intermediate-scale version where multiple LEGs were mounted on a floating cylindrical body, driven by the need to enhance scalability and improve power performance.

16 TIDAL AND WAVE POWER↗

Space applications of superconductivity - Microwave and infrared detectors

This is the fifth of a seven part series on the potential applications of superconductivity in space. The potential of superconducting microwave and infrared detectors for space applications is reviewed. The devices considered include bolometers, super-Schottky diodes and Josephson junctions operating as oscillators, mixers, and parametric amplifiers. In each case the description includes the physical mechanism, theoretical limits and the current state of the art for the superconducting device as well as its nonsuperconducting competitors.

Hamilton, C. A.↗

A monolithic lead sulfide-silicon MOS integrated-circuit structure

A technique is developed for directly integrating infrared photoconductive PbS detector material with MOS transistors. A layer of chromium, instead of aluminum, is deposited followed by a gold deposition in order to ensure device survival during the chemical deposition of the PbS. Among other devices, a structure was fabricated and evaluated in which the PbS was directly coupled to the gate of a PMOS. The external bias, load, and source resistors were connected and the circuit was operated as a source-follower amplifier. Radiometric evaluations were performed on a variety of different MOSFETs of different geometry. In addition, various detector elements were simultaneously fabricated to demonstrate small element capability, and it was shown that elements of 25 x 25 microns could easily be fabricated. Results of room temperature evaluations using a filtered 700 K black body source yielded a detectivity at peak wavelength of 10 to the 11th cm (root Hz)/W at 100 Hz chopping frequency.

Jhabvala, M. D.↗

Modulation techniques for power and spectrally efficient SATCOM systems

Research on modulation/demodulation (modem) techniques which leads to improved power and spectrally efficient digital satellite communications systems is proposed. A new family of digital modems, which enable satellite earth station and satellite transponder operation with fully saturated high power amplifiers (HPA) in an adjacent channel environment, having an optimized P(e) = f(E(sub b)/N(sub o)) performance will be introduced and analyzed.

Feher, Kamilo↗

Design of the American Mobile Satellite System

This paper presents an overview of the American Mobile Satellite Corporation (AMSC) Mobile Satellite System (MSS). A summary of the mobile satellite (MSAT) design and overall performance is provided. The design and components of both the forward link and return link transponders are described in detail. The design and operation of a unique hybrid matrix amplifier that offers flexible power distribution is outlined. The conceptual design and performance of three types of land mobile antennas are described.

Kittiver, Charles↗

Self-Calibrating and Remote Programmable Signal Conditioning Amplifier System and Method

A self-calibrating, remote programmable signal conditioning amplifier system employs information read from a memory attached to a measurement transducer for automatic calibration. The signal conditioning amplifier is self-calibrated on a continuous basis through use of a dual input path arrangement, with each path containing a multiplexer and a programmable amplifier. A digital signal processor controls operation of the system such that a transducer signal is applied to one of the input paths, while one or more calibration signals are applied to the second input path. Once the second path is calibrated, the digital signal processor switches the transducer signal to the second path. and then calibrates the first path. This process is continually repeated so that each path is calibrated on an essentially continuous basis. Dual output paths are also employed which are calibrated in the same manner. The digital signal processor also allows the implementation of a variety of digital filters which are either programmed into the system or downloaded by an operator, and performs up to eighth order linearization.

Medelius, Pedro J.↗

Field intercomparison of a novel optical sensor for formaldehyde quantification

A one-week in situ intercomparison campaign was completed on the Rice University campus for measuring HCHO using three different techniques, including a novel optical sensor based on difference frequency generation (DFG) operating at room temperature. Two chemical derivatization methods, 2,4-dinitrophenylhydrazine (DNPH) and o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA), were deployed during the daylight hours for three- to four-hour time-integrated samples. A real-time optical sensor based on laser absorption spectroscopy was operated simultaneously, including nighttime hours. This tunable spectroscopic source based on difference frequency mixing of two fiber-amplified diode lasers in periodically poled LiNb03 (PPLN) was operated at 3.5315 micrometers (2831.64 cm 1) to access a strong HCHO ro-vibrational transition free of interferences from other species. The results showed a bias of -1.7 and -1.2 ppbv and a gross error of 2.6 and 1.5 ppbv for DNPH and PFBHA measurements, respectively, compared with DFG measurements. These results validate the DFG sensor for time-resolved measurements of HCHO in urban areas.

NASA Discipline Life Sciences Technologies↗

Switch device having a non-linear transmission line

Switching devices are provided. The switching devices include an input electrode, having a main electrode and a trigger electrode, and an output electrode. The main electrode and the trigger electrode are separated from the output electrode by a main gap and a trigger gap, respectively. During operation, the trigger electrode compresses and amplifies a trigger voltage signal causing the trigger electrode to emit a pulse of energy. This pulse of energy form plasma near the trigger electrode, either by arcing across the trigger gap, or by arcing from the trigger electrode to the main electrode. This plasma decreases the breakdown voltage of the main gap. Simultaneously, or near simultaneously, a main voltage signal propagates through the main electrode. The main voltage signal emits a main pulse of energy that arcs across the main gap while the plasma formed by the trigger pulse is still present.

47 OTHER INSTRUMENTATION↗

Techniques for Achieving High Reliability Operation of the Spallation Neutron Source High Power Radio-Frequency System

The Spallation Neutron Source (SNS) high power radiofrequency (HPRF) system operates with high reliability to support the goals of the SNS user program. In recent operational periods the availability of the HPRF system has exceeded 97 percent while the neutron source availability overall is typically greater than 90 percent. SNS has a unique set of 92 HPRF stations that operate at either 402.5 MHz or 805 MHz with peak output power ranging from 550 kW to 5 MW and average power ranging from 49.5 kW to 450 kW. The HPRF transmitters consist of chassis-mounted power supplies, solid-state amplifiers and other equipment that support the operation of the klystrons that ultimately provide the RF power to the accelerating structures. Management of the operation and maintenance of the HPRF system has increasingly focused on reliability and sustainability in recent years. Techniques for klystron lifetime preservation and optimization of transmitter reliability have been developed and will be described.

Moss, John↗

A Likelihood Search for Low-mass Dark Matter via Inelastic Scattering in SuperCDMS

An abundance of evidence suggests that most of the Universe is composed of nonluminous matter. This "dark matter” is believed to be a new elementary particle and experiments around the world are attempting to directly detect rare collisions with terrestrial detectors.The properties of dark matter have yet to be identified, thus efforts are ongoing to explore a range of possible masses and interaction cross-sections. For the latter, experiments can increase exposure by scaling up the detector mass and operating for a longer time. To search for dark matter with less mass than a nucleon, new technologies and analysis techniques need to be developed to be sensitive to energy deposits less than a few keV.SuperCDMS is a direct detection experiment that measures ionization and phonon energy in cryogenic germanium crystal detectors. A special mode of operating the SuperCDMS detectors, called CDMSlite, amplifies the ionization signal via phonon creation. This amplification leads to a lower energy threshold, which provides sensitivity to smaller dark matter masses.Typically, direct detection experiments assume dark matter scatters elastically off the nuclei in the detector. In this thesis, I will highlight the most recent CDMSlite elastic dark matter search. Then I will describe how inelastic dark matter collisions can manifest in the detector and be useful for extending experimental sensitivity to lower dark matter masses. Finally, I will present a re-analysis of CDMSlite data using a profile likelihood to search for low-mass dark matter through two inelastic scattering channels: Bremsstrahlung radiation, and the Migdal Effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Higher-order dispersion compensating pulse shaper via amplitude spectral filtering and nonlinear phase accumulation

A method of pulse shaping using spectral filtering, positive chirp, and self-phase modulation to control the accumulated higher-order phase terms of the spectral phase. This pulse shaping method has particular advantage in fiber chirped pulse amplification (FCPA) systems, where there are two effects: (1) an offsetting of the fourth order phase via nonlinear phase accumulation, allowing for a higher Strehl ratio (i.e., a cleaner pulse), higher peak power pulse and (2) enabling power scaling to higher pulse energies without the increased nonlinear phase accumulation leading to pulse breakup. This technique can be used both in a passive system with no amplification to clean up an existing pulse, and in an amplifier system to enable higher performance operation (shorter pulses, cleaner pulses, higher energy pulses).

Domingue, Scott R.↗

Development of a semi-adiabatic isoperibol solution calorimeter

A semi-adiabatic isoperibol solution calorimeter has been indigenously developed. The measurement system comprises modules for sensitive temperature measurement probe, signal processing, data collection, and joule calibration. The sensitivity of the temperature measurement module was enhanced by using a sensitive thermistor coupled with a lock-in amplifier based signal processor. A microcontroller coordinates the operation and control of these modules. The latter in turn is controlled through personal computer (PC) based custom made software developed with LabView. An innovative summing amplifier concept was used to cancel out the base resistance of the thermistor. The latter was placed in the dewar. The temperature calibration was carried out with a standard platinum resistance (PT100) sensor coupled with an 8½ digit multimeter. The water equivalent of this calorimeter was determined by using electrical calibration with the joule calibrator. The experimentally measured values of the quantum of heat were validated by measuring heats of dissolution of pure KCl (for endotherm) and tris (hydroxyl methyl) amino-methane (for exotherm). The uncertainity in the measurements was found to be within ±3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A wavelength scannable XeCl oscillator-ring amplifier laser system

A holographic grating at grazing angle of incidence was used to achieve tunable, narrow bandwidth (0.005 nm) operation of a XeCl oscillator for injection locking of a ring amplifier. The amplifier's narrow bandwidth output energy was constant and equal to the untuned, broadband output (approximately 15 mJ) in regions where injection locking was achieved. Scanning was provided by use of a stepping motor-driven differential micrometer on the tuning mirror. This system was used to produce a laser excitation spectrum of hydroxyl radicals (OH) in a flame.

Pacala, T. J.↗