Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Three-dimensional trajectory analyses of two drop sizing instruments - PMS OAP and PMS FSSP

Flow-induced distortions of water drop fluxes and speeds as seen by the PMS optical array probe (OAP) and the PMS forward scattering spectrometer probe (FSSP) are estimated via three-dimensional flow and trajectory calculation methods. The sensitivities of the instruments to water drop diameter, angle of attack, and free stream air speed are determined. The instruments are first placed in isolation and then mounted under the wing of a Twin Otter airplane. For the wing-mounted OAP at 4-deg angle of attack, partial flow stagnation under the uptilted wing causes a significant decrease in both the flux and speed for small water drops. For the wing-mounted FSSP, sensitivity is found to both angle of attack and free stream air speed.

Norment, H. G.↗

Three-dimensional trajectory analyses of two drop sizing instruments: PMS OAP and PMS FSSP

Flow induced distortions of water drop fluxes and speeds seen by the instruments were predicted by use of three dimensional flow and trajectory calculation methods. Sensitivities were determined for the instruments, in isolation and mounted under the wing of an airplane, to: water drop diameter (2 to 1000 microns), angle of attack and free stream air speed. For the optical array probe in isolation and on the airplane at 0 deg angle of attack, flux distortions of practical consequence are not found. At 4 deg airplane angle of attack, partial flow stagnation under the uptilted wing causes significant decreases in both flux and speed for cloud size droplets. For the forward scattering spectrometer probe in isolation, only marginally significant sensitivities to free stream air speed are found, and no sensitivity is found to angle of attack. Both speed and flux of cloud size droplets are predicted to be undermeasured by from 12 to 24 percent depending on airplane angle of attack. For the wing-mounted instruments, effects of flow about the instruments themselves are found to be equal in importance to effects of flow about the airplane. Preferred orientation (canting) angles of distorted water drops are found to be functions of drop size, angle of attack and air speed.

Norment, Hillyer G.↗

Three-dimensional trajectory analyses of two drop sizing instruments - PMS OAP and PMS FSSP

Flow induced distortions of water drop fluxes and speeds seen by the instruments were predicted by use of three dimensional flow and trajectory calculation methods. Sensitivities were determined for the instruments, in isolation and mounted under the wing of an airplane, to: water drop diameter (2 to 1000 microns), angle of attack and free stream air speed. For the optical array probe in isolation and on the airplane at 0 deg angle of attack, flux distortions of practical consequence are not found. At 4 deg airplane angle of attack, partial flow stagnation under the uptilted wing causes significant decreases in both flux and speed for cloud size droplets. For the forward scattering spectrometer probe in isolation, only marginally significant sensitivities to free stream air speed are found, and no sensitivity is found to angle of attack. Both speed and flux of cloud size droplets are predicted to be undermeasured by from 12 to 24 percent depending on airplane angle of attack. For the wing-mounted instruments, effects of flow about the instruments themselves are found to be equal in importance to effects of flow about the airplane. Preferred orientation (canting) angles of distorted water drops are found to be functions of drop size, angle of attack and air speed.

Norment, Hillyer G.↗

Liquid water content and droplet size calibration of the NASA Lewis Icing Research Tunnel

The icing research tunnel at the NASA Lewis Research Center underwent a major rehabilitation in 1986 to 1987, necessitating recalibration of the icing cloud. The methods used in the recalibration, including the procedure used to establish a uniform icing cloud and the use of a standard icing blade technique for measurement of liquid water content are described. PMS Forward Scattering Spectrometer and Optical Array probes were used for measurement of droplet size. Examples of droplet size distributions are shown for several median volumetric diameters. Finally, the liquid water content/droplet size operating envelopes of the icing tunnel are shown for a range of airspeeds and are compared to the FAA icing certification criteria.

Ide, Robert F.↗

Liquid water content and droplet size calibration of the NASA Lewis Icing Research Tunnel

The icing research tunnel at the NASA Lewis Research Center underwent a major rehabilitation in 1986 to 1987, necessitating recalibration of the icing cloud. The methods used in the recalibration, including the procedure used to establish a uniform icing cloud and the use of a standard icing blade technique for measurement of liquid water content are described. PMS Forward Scattering Spectrometer and Optical Array probes were used for measurement of droplet size. Examples of droplet size distributions are shown for several median volumetric diameters. Finally, the liquid water content/droplet size operating envelopes of the icing tunnel are shown for a range of airspeeds and are compared to the FAA icing certification criteria.

Ide, Robert F.↗

Cassini Titan Radar Mapper

The Cassini Titan Radar Mapper is a multimode radar instrument designed to probe the optically inaccessible surface of Titan, Saturn's largest moon. The instrument is to be included in the payload of the Cassini Saturn Mission, scheduled for launch in 1995. The individual modes of Cassini Radar Mapper will allow topographic mapping and surface imaging at few hundred meters resolution. The requirements that lay behind the design are briefly discussed, and the configuration and capability of the instrument are described. The present limited knowledge of Titan's surface and the measurement requirements imposed on the radar instrument are addressed. Also discussed are the Cassini mission and the projected orbits, which imposed another set of design constraints that led to the multitude of modes and to an unconventional antenna configuration. The antenna configuration and the different radar modes are described.

Elachi, Charles↗

Near-infrared images of the nuclear region of NGC 5128

High-resolution near-infrared images of NGC 5128 (Centaurus A) are presented, which probe the optically obscured nuclear region. The images show a central source at K (2.23 microns) and 3.26 microns. This central object is not prominent in the shorter wavelength images at J and H (1.23 and 1.65 micron, respectively), probably due to high extinction. The color images (H - K and J - H) provide evidence for a steep gradient in extinction across the array field. The images indicate three components: a red, variable, compact nucleus; the diffuse elliptical galaxy starlight; and a blue extension to the NE. The nucleus has decreased in flux density by a factor of 2.5 over less than about 5 yr at 3.26 microns. However, current spectral constraints on the nuclear source at near-infrared wavelengths cannot definitively determine the relative contributions from the known ratio synchrotron source (AGN) and from various possible dust-enshrouded thermal sources. The blue spot, approximately 7.6 +/- 0.1 arcsec NE of the nucleus appears to be a hole in the extinction, possibly enhanced by scattered light from the active galactic nucleus.

Turner, Paula C.↗

Materials surface contamination analysis

The original research objective was to demonstrate the ability of optical fiber spectrometry to determine contamination levels on solid rocket motor cases in order to identify surface conditions which may result in poor bonds during production. The capability of using the spectral features to identify contaminants with other sensors which might only indicate a potential contamination level provides a real enhancement to current inspection systems such as Optical Stimulated Electron Emission (OSEE). The optical fiber probe can easily fit into the same scanning fixtures as the OSEE. The initial data obtained using the Guided Wave Model 260 spectrophotometer was primarily focused on determining spectra of potential contaminants such as HD2 grease, silicones, etc. However, once we began taking data and applying multivariate analysis techniques, using a program that can handle very large data sets, i.e., Unscrambler 2, it became apparent that the techniques also might provide a nice scientific tool for determining oxidation and chemisorption rates under controlled conditions. As the ultimate power of the technique became recognized, considering that the chemical system which was most frequently studied in this work is water + D6AC steel, we became very interested in trying the spectroscopic techniques to solve a broad range of problems. The complexity of the observed spectra for the D6AC + water system is due to overlaps between the water peaks, the resulting chemisorbed species, and products of reaction which also contain OH stretching bands. Unscrambling these spectral features, without knowledge of the specific species involved, has proven to be a formidable task.

Workman, Gary L.↗

Unequilibrated, equilibrated, and reduced aggregates in anhydrous interplanetary dust particles

Track-rich anhydrous IDP's are probably the most primitive IDP's because they have escaped significant post-accretional alteration; they exhibit evidence of (nebular) gas phase reactions; their mineralogy is similar to comet Halley's dust; and some of them exhibit comet-like IR spectral characteristics. However, basic questions about the mineralogy and petrography of anhydrous IDP's remain unanswered, because they contain aggregated components that can be heterogeneous on a scale of nanometers. In some IDP's, aggregates account for greater than 75 percent of the volume of the particle. The aggregates have been systematically examined using an analytical electron microscope (AEM), which provides probe-forming optics and (x-ray and electron) spectrometers necessary to analyze individual nanometer-sized grains. The AEM results reveal at least three mineralogically distinct classes of aggregates in an hydrous IDP's, with mineralogies reflecting significantly different formation/aggregation environments.

Bradley, J. P.↗

Aubrite basalt vitrophyres: High sulfur silicate melts and a snapshot of aubrite formation

Two aubrite basalt vitrophyre clasts have been found within AMNH thin sections from the Parsa EH3 chondrite and the Khor Temiki aubrite. Polished sections of the Parsa Aubrite Inclusion (PAI) and the Khor Temiki Inclusion (KTI) were studied by optical, electron probe microanalysis (EPMA), and scanning electron microscopy (SEM) techniques with broad-beam and low absorbed EPMA currents used to minimize glass volatile loss. Some data have previously been reported for PAI and KTI may possibly correlate to a previously reported inclusion in Khor Tiimiki. In polished sections, PAI and KTI are approximately equal 4 mm in diameter and contain a large volume of glass. The clasts have similar textural characteristics and are akin to lunar vitrophyre textures. The glasses have high alkali rhyodacitic compositions Al-though PAI is peraluminous, KTI is significantly peralkaline. Additionally, the glasses have elevated sulfur concentrations that are extremely high by geochemical standards. SEM examination for beam overlap of microscopic CaS, FeS, and (Mg, Mn, Fe) S inclusions showed no such contamination. Furthermore, homogeneity of glass S content and low FeO contents help rule out contamination. Materials research data show that under reducing conditions alumino-silicate melts can dissolve up to several weight percent sulfur in the absence of Fe. The high S and alkali contents, the lack of associated high shock features, and the rationalized phase equilibria suggest that PAI and KTI are igneous melting products of an E-chondrite-like source material. Although large-scale impact melting cannot totally be ruled out, the above observations eliminate the possibility of in-situ shock melting.

Fogel, R. A.↗

A Multi-Instrument Approach for Characterizing the Vertical Structure of Aerosol Properties: Case Studies in the Pacific Basin Troposphere

During February/March 1994, a series of aircraft-based aerosol measurements were carried out in the Pacific Basin troposphere using a differential absorption lidar system deployed by NASA Langley, and optical spectrometer probes and a wire-impactor system operated by NASA Ames. A modified Klett inversion algorithm was applied to extract altitude profiles of aerosol backscattering from the IR lidar signal. The algorithm that we have designed for this purpose utilizes the in situ aerosol measurements to normalize the lidar profile at the aircraft altitude and to supply the lidar ratio as a function of height. The lidar-derived aerosol backscattering coefficients were then compared to the backscattering coefficients calculated from the in situ measurements. During several local aircraft descents, we found good agreement between the remote lidar and in situ results for the absolute value of the aerosol backscattering coefficient and its altitude variation only when we allowed for several layers with different aerosol refractive indices. The agreement validates our lidar calibration method and provides an indication of the variation in aerosol refractive index as a function of altitude. Two of the three case studies performed in this paper reveal layers of anthropogenic aerosols transported long distances into the Pacific Basin troposphere. A third case implies the existence of a layer of dustlike aerosol particles in the lower troposphere, most likely of Asian origin.

Redemann, J.↗

Exciton Absorption in Semiconductor Quantum Wells Driven by a Strong Intersubband Pump Field

Optical interband excitonic absorption of semiconductor quantum wells (QW's) driven by a coherent pump field is investigated based on semiconductor Bloch equations. The pump field has a photon energy close to the intersubband spacing between the first two conduction subbands in the QW's. An external weak optical field probes the interband transition. The excitonic effects and pump-induced population redistribution within the conduction subbands in the QW system are included. When the density of the electron-hole pairs in the QW structure is low, the pump field induces an Autler-Townes splitting of the exciton absorption spectrum. The split size and the peak positions of the absorption doublet depend not only on the pump frequency and intensity but also on the carrier density. As the density of the electron-hole pairs is increased, the split contrast (the ratio between the maximum and minimum values) is decreased because the exciton effect is suppressed at higher densities due to the many-body screening.

Liu, Ansheng↗

Physics of Colloids in Space-2 (PCS-2)

The Physics of Colloids-2 (PCS-2) experiment is aimed at investigating the basic physical properties of several types of colloidal suspensions. The three broad classes of colloidal systems of interest are binary colloids, colloid-polymer mixtures, and fractal gels. The objective is to understand their phase behavior as well as the kinetics of the phase transitions in the absence of gravity. The nucleation, growth, and morphology characteristics of the crystals and gels that form would be studied using confocal microscopy. These will be observed directly with excellent time resolution, and therefore extensive information about the different phases and their growth mechanisms will be gained. With the laser tweezers, it will be possible to measure the strength of these structures and to modify them in a controlled way, and the spectrophotometer will provide the possibility to probe their optical properties. We believe that this experiment will provide the basis for future 'colloid engineering' in which complicated structures with novel properties (e.g., photonic crystals) will be grown by controlled self-assembly.

Sankaran, Subramanian↗

Electromagnetic Detection of Fatigue Cracks under Protruding Head Ferromagnetic Fasteners

The detection of fatigue cracks under installed fasteners has been a major goal of the aging aircraft NDE community. The Sliding Probe, Magneto-Optic Imager, Rotating Self-Nulling Probe, Low Frequency Eddy Current Array, and Eddyscan systems are among the instruments developed for this inspection. It has been verified that the detection of fatigue cracks under flush head aluminum and titanium fasteners can be accomplished with a high resolution by the above techniques. The detection of fatigue cracks under ferromagnetic and protruding head fasteners, however, has been found to be much more difficult. For the present work, the inspection for fatigue cracks under SAE 4340 Steel Hi-Lok fasteners is explored. Modifications to the Rotating Self-Nulling Eddy Current Probe System are presented which enable the detection of fatigue cracks hidden under the protruding head of the ferromagnetic fastener. Inspection results for samples with varying length EDM notches are shown, as well as a comparison between the signature from an EDM notch and an actual fatigue crack. Finite Element Modeling is used to investigate the effect of the ferromagnetic fastener on the induced eddy current distribution in order to help explain the detection characteristics of the system. This paper will also introduce a modification to the Rotating Probe System designed specifically for the detection of deeply buried flaws in multilayer conductors. The design change incorporates a giant magnetoresistive (GMR) sensor as the pickup device to improve the low frequency performance of the probe. The flaw detection capabilities of the GMR based Self- Nulling Probe are presented along with the status of the GMR based Rotating Probe System for detection of deeply buried flaws under installed fasteners.

Wincheski, Buzz↗

System Being Developed to Measure the Rotordynamic Characteristics of Air Foil Bearings

Because of the many possible advantages of oil-free engine operation, interest in using air lubricated foil-bearing technology in advanced oil-free engine concepts has recently increased. The Oil-Free Turbomachinery Program at the NASA Glenn Research Center at Lewis Field has partially driven this recent push for oil-free technology. The program's goal of developing an innovative, practical, oil-free gas turbine engine for aeropropulsion began with the development of NASA's high-temperature solid-lubricant coating, PS304. This coating virtually eliminates the life-limiting wear that occurs during the startup and shutdown of the bearings. With practically unlimited life, foil air bearings are now very attractive to rotating machinery designers for use in turbomachinery. Unfortunately, the current knowledge base of these types of bearings is limited. In particular, the understanding of how these types of bearings contribute to the rotordynamic stability of turbomachinery is insufficient for designers to design with confidence. Recent work in oil-free turbomachinery has concentrated on advancing the understanding of foil bearings. A high-temperature fiber-optic displacement probe system and measurement method were developed to study the effects of speed, load, temperature, and other environmental issues on the stiffness characteristics of air foil bearings. Since high temperature data are to be collected in future testing, the testing method was intentionally simplified to minimize the need for expensive test hardware. The method measures the displacement induced upon a bearing in response to an applied perturbation load. The early results of these studies, which are shown in the accompanying figure, indicate trends in steady state stiffness that suggest stiffness increases with load and decreases with speed. It can be seen, even from these data, that stiffness is not expected to change by orders of magnitude over the normal operating range of most turbomachinery; a promising sign for their eventual integration into oil-free turbomachines. Planned future testing will generate similar plots for stiffness changes with temperature and geometry, as well as damping data. The data collected by this method represent a critical step toward understanding how to successfully apply foil air bearings to future oil-free turbomachinery systems.

Howard, Samuel A.↗

Development Status of Cassini Radar For Remote Sensing of Titan

Cassini Radar is a multimode rada instrument designed to probe the optically inaccessible surface of Titan, Saturn's largest moon. The individual modes will allow surface imaging, surface emissivity measurements. Recently, the breadboard model of this instrument was built and has undergone a series of functional and perfomance tests. The results obtained from these tests indicate that the instrument design is satisfactory and that the various required performance parameters are suffieciently met.

Cassini Radar Titan↗

Nanocarpets for Trapping Microscopic Particles

Nanocarpets that is, carpets of carbon nanotubes are undergoing development as means of trapping microscopic particles for scientific analysis. Examples of such particles include inorganic particles, pollen, bacteria, and spores. Nanocarpets can be characterized as scaled-down versions of ordinary macroscopic floor carpets, which trap dust and other particulate matter, albeit not purposefully. Nanocarpets can also be characterized as mimicking both the structure and the particle-trapping behavior of ciliated lung epithelia, the carbon nanotubes being analogous to cilia. Carbon nanotubes can easily be chemically functionalized for selective trapping of specific particles of interest. One could, alternatively, use such other three-dimensionally-structured materials as aerogels and activated carbon for the purposeful trapping of microscopic particles. However, nanocarpets offer important advantages over these alternative materials: (1) Nanocarpets are amenable to nonintrusive probing by optical means; and (2) Nanocarpets offer greater surface-to-volume ratios.

Noca, Flavio↗