Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimal Power Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Reliable algorithms for power system analysis in the presence of data uncertainties

A robust and reliable power flow analysis represents an essential requirement for many power systems applications as far as network optimization, voltage control, state estimation, and service restoration are concerned. The most common power flow approach, referred to here as a deterministic power flow (PLF), requires precise or 'crisp' values chosen by the analyst for each input variable. The solution provides precise network voltages and flows through each line. The specified values rest upon assumptions about the operating condition derived from historical measurements or predictions about future conditions and thus, cannot be considered accurate. Even in the case where the inputs are based on measurements, inaccuracies arise from time-skew problems, three-phase unbalance, static modeling approximations of dynamic components (e.g., transformer tap changers), variations in line parameters, and so on. The advent of deregulation and competitive power markets will only exacerbate this problem as well-known generation patterns change, loading becomes less predictable and the transmission paths grow more diverse. Conventional methodologies proposed in literature address tolerance analysis of power flow solution by means of detailed probabilistic methods, accounting for the variability and stochastic nature of the input data, and sampling based approaches. In particular uncertainty propagation using sampling based methods, such as the Monte Carlo, requires several model runs that sample various combinations of input values. Since the number of model runs can sometimes be very large, the required computer resources can sometimes be prohibitively expensive resulting in substantial computational demands. As far as probabilistic methods are concerned, they represent a useful tool, especially for planning studies, but, as evidenced by the many discussions reported in literature, they could reveal some shortcomings principally arising from: (1) the non-normal distribution and the statistical dependence of the input data; and (2) the difficulty arising in accurately identifying probability distributions for some input data, such as the power generated by wind or photovoltaic generators. All these could result in time consuming computations with several limitations in practical applications especially in power flow analysis of complex power networks. In order to try and overcome some of these limitations, obtaining thereby comprehensive power flow solution tolerance analysis at adequate computational costs, self validated computation could play a crucial role. Armed with such a vision, this chapter will analyze two advanced techniques for power flow analysis in the presence of data uncertainty namely the boundary power flow and the affine arithmetic power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reduced order model based on principal component analysis for process simulation and optimization

It is well-known that distributed parameter computational fluid dynamics (CFD) models provide more accurate results than conventional, lumped-parameter unit operation models used in process simulation. Consequently, the use of CFD models in process/equipment co-simulation offers the potential to optimize overall plant performance with respect to complex thermal and fluid flow phenomena. Because solving CFD models is time-consuming compared to the overall process simulation, we consider the development of fast reduced order models (ROMs) based on CFD results to closely approximate the high-fidelity equipment models in the co-simulation. By considering process equipment items with complicated geometries and detailed thermodynamic property models, this study proposes a strategy to develop ROMs based on principal component analysis (PCA). Taking advantage of commercial process simulation and CFD software (for example, Aspen Plus and FLUENT), we are able to develop systematic CFD-based ROMs for equipment models in an efficient manner. In particular, we show that the validity of the ROM is more robust within well-sampled input domain and the CPU time is significantly reduced. Typically, it takes at most several CPU seconds to evaluate the ROM compared to several CPU hours or more to solve the CFD model. Two case studies, involving two power plant equipment examples, are described and demonstrate the benefits of using our proposed ROM methodology for process simulation and optimization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Numerical analysis of downhole heat exchanger designed for geothermal energy production

A traditional way of geothermal energy production implies hot brine extraction from the reservoir to a surface facility. This method is economically profitable only for high enthalpy reservoirs associated with shallow depths and high temperatures. The low enthalpy geothermal (LEG) projects are out of consideration due to the high cost of produced electric power related to expensive drilling, cost of the binary cycle system, and long term installation cost. This paper presents a new zero mass extraction method utilizing downhole heat exchanger (DHE) with no geo-fluid production to the surface. The well design stays as a single horizontal well with coupled production and injection sections. The brine pump is located between the sections providing hot brine circulation through the DHE. The coupled fluid flow and heat transfer mathematical model was developed and simulated using nodal analysis method. The LEG reservoir prototype located in South Louisiana was used to study several cases of the DHE lengths, inclination angles, reservoir permeabilities, and flow rates optimization. According to the analysis, the power unit is able to provide 160 kW of net electric power with CO2 working fluid circulating inside a single lateral well. Increasing the reservoir temperature and the number of laterals, the available power production rises up to 600 kW with an attractive electricity cost of $21.84/MWh at 7000 m well depth. This methods opens a new prospective for the depleted petroleum wells converting them to the electricity production units.

15 GEOTHERMAL ENERGY↗

Decision-Dependent Uncertainty-Aware Distribution System Planning Under Wildfire Risk

The interaction between power systems and wildfires can be dangerous and costly. Distribution grids can be liable for the outbreak of wildfires during extreme weather. In wildfire-prone areas, investment planning should consider the impact of operational actions on wildfire-related uncertainties affecting line failure likelihood. Here, in this case, endogenous-based uncertainty modeling should comprise the backbone of the investment planning model viz-a-viz the inability of standard exogenous-based uncertainty modeling. Therefore, we propose a decision-dependent uncertainty (DDU) aware methodology to optimize investment portfolios for distribution systems, considering that high power-flow levels in high-threat areas can ignite wildfires and increase line failure probability. The methodology identifies the best combination of upgrades (new lines, hardening existing lines, and placing switching devices). Methodologically, we propose a two-stage distributionally robust planning optimization problem with DDU that considers the distribution system's multiperiod operation. The first stage determines optimal switching actions and line investments, and the second stage evaluates the worst-case expected operational cost under a DDU framework designed to account for the endogenous impact of power-flow levels and hardening investment decisions in the line failure probabilities. An iterative method is tailored to handle the problem and numerical experiments demonstrate a more prepared grid to deal with wildfire risk.

Power systems investment planning↗

Distributionally Robust Bilevel Optimization Model for Distribution Network With Demand Response Under Uncertain Renewables Using Wasserstein Metrics

Here, we consider a distribution network integrating demand response (DR) participants in the presence of uncertain renewable suppliers and outdoor temperatures. A bilevel optimization model is proposed to capture the intricate dynamics between price-incentivized DR participants and distribution system operations, including energy procurement and active/reactive power flows. The model is formulated as a distributional robust bilevel optimization using Wasserstein metrics. We show favorable data-driven properties including out-of-sample guarantee and asymptotic consistency. Furthermore, we present a tractable mixed-integer linear programming reformulation and characterize the worst-case distribution. Computational experiments are conducted on a modified 33-bus system. Our findings underscore the efficacy of the pricing strategies derived from the proposed bilevel optimization model. These strategies not only effectively manage DR participants' behavior but also bring equity considerations among households with various characteristics to light. The results contribute to a deeper understanding of the interplay between distribution system operators and DR participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal PMU Restoration for Power System Observability Recovery After Massive Attacks

Cyber-physically resilient power system operation requires rapid recovery of situational awareness after disastrous scenarios such as massive cyber attacks. In this article, the concept of optimal sequential restoration of Phasor Measurement Units is introduced, aiming at rapid recovery of power system observability in post-attack scenarios. Additionally, the observability recovery problem is formulated as a Mixed Integer Linear Programming problem to maximize the cumulative observability level gained over time during the restoration process. Three alternative objective functions-maximizing the number of observable buses, the number of observable branches, and the total amount of observable power flow-are considered. The effectiveness of the proposed optimal strategy is verified by comparing it with heuristic approaches on the IEEE 57-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gas Generator Feedline Orifice Sizing Methodology: Effects of Unsteadiness and Non-Axisymmetric Flow

Engine LH2 and LO2 gas generator feed assemblies were modeled with computational fluid dynamics (CFD) methods at 100% rated power level, using on-center square- and round-edge orifices. The purpose of the orifices is to regulate the flow of fuel and oxidizer to the gas generator, enabling optimal power supply to the turbine and pump assemblies. The unsteady Reynolds-Averaged Navier-Stokes equations were solved on unstructured grids at second-order spatial and temporal accuracy. The LO2 model was validated against published experimental data and semi-empirical relationships for thin-plate orifices over a range of Reynolds numbers. Predictions for the LO2 square- and round-edge orifices precisely match experiment and semi-empirical formulas, despite complex feedline geometry whereby a portion of the flow from the engine main feedlines travels at a right-angle through a smaller-diameter pipe containing the orifice. Predictions for LH2 square- and round-edge orifice designs match experiment and semi-empirical formulas to varying degrees depending on the semi-empirical formula being evaluated. LO2 mass flow rate through the square-edge orifice is predicted to be 25 percent less than the flow rate budgeted in the original engine balance, which was subsequently modified. LH2 mass flow rate through the square-edge orifice is predicted to be 5 percent greater than the flow rate budgeted in the engine balance. Since CFD predictions for LO2 and LH2 square-edge orifice pressure loss coefficients, K, both agree with published data, the equation for K has been used to define a procedure for orifice sizing.

Rothermel, Jeffry↗

Under-Track CFD-Based Shape Optimization for a Low-Boom Demonstrator Concept

The detailed outer mold line shaping of a Mach 1.6, demonstrator-sized low-boom concept is presented. Cruise trim is incorporated a priori as part of the shaping objective, using an equivalent-area-based approach. Design work is performed using a gradient-driven optimization framework that incorporates a three-dimensional, nonlinear flow solver, a parametric geometry modeler, and sensitivities derived using the adjoint method. The shaping effort is focused on reducing the under-track sonic boom level using an inverse design approach, while simultaneously satisfying the trim requirement. Conceptual-level geometric constraints are incorporated in the optimization process, including the internal layout of fuel tanks, landing gear, engine, and crew station. Details of the model parameterization and design process are documented for both flow-through and powered states, and the performance of these optimized vehicles presented in terms of inviscid L/D, trim state, pressures in the near-field and at the ground, and predicted sonic boom loudness.

Wintzer, Mathias↗

Optimal Regulation of Virtual Power Plants

This paper develops a real-time algorithmic framework for aggregations of distributed energy resources (DERs) in distribution networks to provide regulation services in response to transmission-level requests. Leveraging online primal-dual-type methods for time-varying optimization problems and suitable linearizations of the nonlinear AC power-flow equations, we believe this work establishes the system-theoretic foundation to realize the vision of distribution-level virtual power plants. The optimization framework controls the output powers of dispatchable DERs such that, in aggregate, they respond to automatic-generation-control and/or regulation-services commands. This is achieved while concurrently regulating voltages within the feeder and maximizing customers' and utility's performance objectives. Convergence and tracking capabilities are analytically established under suitable modeling assumptions. Simulations are provided to validate the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Assisted Design for Remote Areas

In this work, we present a three-stage multiobjective mixed-integer linear programming (MILP) for the optimal expansion planning and operation of isolated multienergy microgrids in remote areas. By selecting the optimal distributed generators (DGs) and energy storage systems (ESSs) mix selection, siting, sizing, and scheduling in the remote microgrid, the proposed model is targeted to minimize the annualized total cost of microgrids while enhancing the performance of the system, i.e., minimizing the voltage deviations and line power loss. To represent the electricity and heat flow between generation resources and various electrical, heating, and cooling loads in the isolated microgrid, linearized power flow, and heat flow constraints are employed in the proposed optimization model. The available capacity of DGs and ESSs are modeled as discrete constants instead of continuous variables for practical purpose. Numerical simulation results on a remote microgrid consisting of DGs, ESSs, and various loads validate the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The role of the spatial heterogeneity and correlation length of surface wettability on two-phase flow in a CO 2 -water-rock system

This study characterized and modeled heterogeneous surface wettability in sandstone and investigated the role of spatial heterogeneity and correlation length of surface wettability on relative permeability in a supercritical CO 2 (scCO 2 )-brine-rock system. Understanding the role of wettability heterogeneity on relative permeability is essential to geological CO 2 sequestration, oil and gas recovery, and contaminated groundwater remediation. Although numerous studies have attempted to understand the influences of surface wettability, capillary number (Ca), and viscosity ratio, the role of the spatial variation and correlation length of surface wettability on two-phase flow in three-dimensional (3D) porous media has not been unraveled due to the challenges in the measurement and representation of realistic rock surface wettability. In this work, we conducted in-situ measurements of surface contact angle (CA) in a Bentheimer sandstone after CO 2 flooding using micro-computed tomography (micro-CT), and found that the pore-scale CA distribution on rock surfaces followed a log-normal distribution associated with a spatial correlation length. Based on the statistical information from CT scanning, a Gaussian random field was used to model CA distributions that had desired standard deviations and spatial correlation lengths, which were then adjusted within a certain range of values for sensitivity analyses to study their combined effects on the two-phase flow in the porous medium using the lattice Boltzmann (LB) method. The LB two-phase flow simulation was accelerated using hybrid, multicore parallel computing to overcome the challenges in simulating multiphase flow in a large 3D domain having 800 × 800 × 600 nodes. The simulation results showed that the surface wettability heterogeneity (i.e., standard deviation of CA) had a lesser effect on the relative permeability of the wetting fluid (water) but a more significant impact on the relative permeability of the non-wetting fluid (scCO 2 ). The Corey model was used to fit the LB-simulated relative permeability curves of water and scCO 2 and showed that the variations in the relative permeability curves for both water and scCO 2 increased as the standard deviation and spatial correlation length of CA increased. This study illustrated that the assumption of homogeneous surface wettability may cause errors in multiphase flow simulations. Furthermore, the impacts of both the standard deviation and spatial correlation length of CAs should be accounted for. This is the first study that explored the spatial correlation lengths associated with CA distributions on sandstone surfaces and comprehensively investigated the roles of both spatial variation and correlation length of CA on two-phase flow properties in 3D porous media. The optimized LB multiphase flow model was proved a powerful tool to study the interplays and combined effects of these statistical parameters, which had critical applications in numerous natural and engineering processes that involved multiphase flow in porous media.

58 GEOSCIENCES↗

Sample EP Flow Analysis of Severely Damaged Networks

These are slides for a presentation at the working group meeting of the WESC SREMP Software Product Integration Team on sample EP flow analysis of severely damaged networks. The following topics are covered: ERCOT EP Transmission Model; Zoomed in to Houston and Overlaying StreetAtlas; EMPACT Solve/Dispatch/Shedding Options; QACS BaseCase Power Flow Solution; 3 Substation Contingency; Gen. & Load/100 Optimal Dispatch; Dispatch Results; Shed Load for Low V; Network Damage Summary; Estimated Service Areas (Potential); Estimated Outage Areas (potential).

97 MATHEMATICS AND COMPUTING↗

Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents

This report summarizes the work performed under the Department of Energy’s National Energy Technology Laboratory (DOE-NETL) Advanced Energy Systems Program award number DE-FE0026163 Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents. The overall objective of the project was to develop technology to produce oxygen for use in coal gasification processes at a significantly lower cost than that of the commercial state-of-the-art technology. The focus of the project was development and optimization of hollow fiber sorbents for use in a pressure swing adsorption (PSA) process for producing oxygen from air. The key technical advancement under this program was the development of a hollow fiber sorbent capable of producing oxygen in a PSA process. PSAs produce oxygen by using a beaded zeolite material (typically lithium exchanged zeolites or LiX) that selectively adsorb nitrogen over oxygen. For a fiber to adsorb nitrogen, LiX needed to be integrated into a polymer fiber and then activated at over 350C to remove residual moisture. After screening multiple materials and process techniques, Matrimid/LiX hollow fibers were produced that were able to withstand the activation and had crystalline nitrogen capacity close to pure LiX crystals. The fibers were dual layer fibers with a barrier layer isolating the hollow bore from the LiX embedded layer. The barrier layer was formed from an Ultem® based solution. The hollow bore was intended for encapsulating phase change materials to ensure isothermal PSA operation. Modeling work from the project suggested that the benefits of this additional complexity were marginal, thus the team fabricated non-hollow fibers comprised of Matrimid and LiX. The Matrimid/LiX fibers were loaded into a module and tested on a bench scale PSA unit. The fibers were able to separate oxygen from air, but the purity and recovery were lower than expected and lower than traditional beaded LiX zeolites, although modeling results suggested that the bed sizes for fiber sorbents could be half the size of a beaded LiX bed. Additional work will be needed to understand the shortfall and to produce fiber sorbent modules with performance equal to the targets set for this program. In addition to producing fibers, modeling work was carried out at both the fiber level and process level to guide both fiber sorbent development and to determine the optimal process conditions for a PSA using fiber sorbents. A 2D hollow fiber model was developed in gPROMS Model Builder. This model was based on literature data for mass transfer and other parameters. This model used a basic single bed PSA process to determine important fiber properties and process conditions for achieving high oxygen recovery. The preliminary 2D fiber model was a valuable tool, however, for step-out technologies, such as a PSA process with fiber sorbents, intelligent optimization and plant control was needed to effectively determine minimum power designs. Therefore, a gPROMS Process Builder-based optimization tool was developed with an “Automated Cycle Optimizer” model that was able to determine optimal cycle conditions for a fiber sorbent PSA. The results from the optimizer were used in the final power analysis. Flow sheet analysis and techno-economic analysis (TEA) was carried out to determine a lower power solution versus the baseline case. The original project scope suggested that the fiber sorbent PSA could be used to debottleneck a cryogenic air separation plant (cryo-ASU) with the combined plant having lower power than a standalone cryo-ASU. However, early flowsheet analysis showed that the PSA/cryo-ASU concept would not lead to a lower power solution. However, further flowsheet analysis suggested that an oxygen PSA combined with a nitrogen PSA could have lower power versus state-of-the-art air separation technology. Work concluded with the TEA showing a fiber sorbent oxygen PSA combined with an advanced nitrogen PSA could be up to 8% lower power versus the base case cryo-ASU. Overall, there is significant potential remaining for the zeolite hollow fiber sorbent concept, and this project successfully identified -- and ultimately remedied -- many technical challenges associated with scale-up.

01 COAL, LIGNITE, AND PEAT↗

Electric propulsion for communications satellites

Electric propulsion systems derive their low overall mass, relative to chemical propulsion systems, from an optimized mix of independently controlled power and mass flow rate. A significant reduction in mass can be secured by substituting electric propulsion for conventional hydrazine systems for all the major propulsion tasks of a communications satellite. Additional advantages for all electric propulsion maneuvers are precision location and higher pointing accuracy. Three auxiliary electric propulsion systems are now available for application on communications satellites: the electrically augmented hydrazine system, the Teflon pulsed plasma system, and the mercury ion thruster system. Primary electric propulsion will be available in the mid to late 1980s as a spin-off of NASA's program of interplanetary exploration.

Free, B. A.↗

The Future of Renewable Energy Transmission: An Autonomous Energy Grid

The drastic price reduction in variable renewable energy, such as wind and solar, coupled with the ease of use of smart technologies at the consumer level, is driving dramatic changes to the power system that will significantly transform how power is made, delivered, and used. Distributed energy resources (DERs)—which can include solar photovoltaic (PV), fuel cells, microturbines, gensets, distributed energy storage (e.g., batteries, ice storage), and new loads (e.g., electric vehicles (EVs), light-emitting diode (LED) lighting, smart appliances, and electric heat pumps)—are being added to electric grids and causing bidirectional power flows and voltage fluctuations that can impact optimal control and system operation. Residential solar installations, customer battery systems, and EVs are all seeing rapid increases in deployments. With DER seeing such increased use, it is not unreasonable to imagine a residential electricity customer having at least five controllable DERs. In future electric grids, as more DERs are integrated, the number of active control points will be too much for current control approaches to effectively manage.

30 DIRECT ENERGY CONVERSION↗

Laboratory Evaluation of Federated, Hierarchical Controls for Distribution Power System Management: Preprint

The connection of more loads and distributed energy resources (DERs) to the distribution power system brings both challenges and opportunities to system operators. There are opportunities to aggregate flexible loads and DERs to provide transmission grid services, but the coordinated actions of DERs being managed by independent, third-party DER aggregators to support transmission system operations can present challenges. We developed a federated DER management architecture and control framework that aims to manage heterogeneous DERs to deliver reliable transmission grid services while respecting distribution system constraints. The controls include stochastic day-ahead optimization, model predictive control, and a simple real-time management scheme. We present simulation results obtained from a realistic laboratory test bed of federated controls managing DERs within a substation service area to make the substation net power follow the optimal net power determined by the day-ahead optimization based on cost and limiting reverse power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operation and Optimization of Microwave-Heated Continuous-Flow Microfluidics

Microwave (MW) technology can be powerful for electrification and process intensification but limited fundamental understanding of scalability and design principles hinders its effective use. In this work, we build a continuous-flow microreactor inside a commercial single-mode MW applicator and the corresponding computational fluid dynamics model to simulate the temperature profile. The model is in good agreement with experiments for various microreactor dimensions and operating conditions. The model indicates that MW heating is greatly influenced by reactor geometry as well as the operating parameters. We observe a strong correlation between parameters and develop a gradient boost regression tree model to predict the outlet temperature accurately. This model is then applied to optimize the dimensions and operating conditions to maximize the outlet temperature and energy efficiency, resulting in a Pareto optimal. We demonstrate computationally and experimentally that it is possible to surpass the Pareto optimal and achieve an energy efficiency of ~90% or greater at temperatures relevant for liquid-phase chemistry via salting of the solvent. The present methodology can be applied to other complex MW reactors. Lastly, the combined numerical and experimental approach provides insights into and a framework for scale-up and optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DBD plasma-assisted ethanol steam reforming for green H 2 production: Process optimization through response surface methodology (RSM)

Herein this work investigates ethanol steam reforming (ESR) to produce hydrogen (H 2 ) in a dielectric barrier discharge (DBD) plasma reactor. A five-level, three-factor experiment design was performed using a response surface methodology (RSM) to evaluate the combined effects of the three process parameters, including discharge power, total flow rate, and ethanol-to-water (EtOH/H 2 O) molar ratio on the plasma-assisted ESR reaction. Quadratic regression models were employed in RSM to fit the experimental results and present the correlation between process parameters and targeted responses (EtOH conversion, H 2 yield, H 2 selectivity, and specific energy requirement (SER) for H 2 production). The results suggested that the EtOH/H 2 O molar ratio is considered to have the most significant effect on the EtOH conversion and H 2 , H 2 selectivity, while the total flow rate is the most significant parameter determining SER for H 2 production. Process optimization demonstrated the optimal process conditions, including a discharge power of 55.9 W, a total flow rate of 26.7 ml/min, and an EtOH/H 2 O molar ratio equal to 0.34. A validation test was performed and confirmed the feasibility of the optimization process.

08 HYDROGEN↗