Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Imaging and manipulation of the competing electronic phases near the Mott metal-insulator transition

Multiple nearly degenerate states in transition-metal oxides (TMOs) produce very complicated phase diagrams1. Small perturbations can often lead to dramatic property change and even exotic functionalities such as superconductivity and colossal magnetoresistance (CMR)2,3,4. Many of these emergent properties displayed by these correlated materials are believed to be intimately associated with the electronic inhomogeneities that can self-organize into spatially separated electronic phases. Direct imaging of the phase separations (PS) has thus become vital to elucidating the underlying mechanisms, and the successful observation of the PS in manganites has led to a breakthrough understanding of CMR5,6. Here, we present real-space visualizations of the PS and the dynamic evolutions of phase domains with strain and temperature in a bilayered ruthenate. Our experimental approach combines electron microscopy, scanning tunneling microscopy, and in-situ electron transport spectroscopy, which provides unprecedented capabilities of imaging PS and interrogating individual microscopic domains in real-space and real-time. A quantitative correlation has been determined between the macroscopic metal-insulator transition (MIT) and the microscopic phase domain percolation near the Mott transition of a Sr3(Ru1-xMnx)2O7. Strikingly, the PS is not associated with inhomogeneous doping and the MIT can be controlled by uniaxial stress, validating the important role of electron-lattice interactions in PS. The dynamics of strain-induced domain evolution exhibits a diffuse phase transition behavior, demonstrating the unconventional phase control of the electronic states with strain in ruthenates.

36 MATERIALS SCIENCE↗

Phase calibration of imaging radar polarimeter Stokes matrices

It is shown that the Stokes matrices measured by an imaging radar polarimeter provide enough information for the accurate phase calibration of the observed polarimetric characteristics of a surface. This is important because it allows the data to be reduced in volume in an operational synthetic aperture radar correlator with no prior knowledge of the conditions at the surface, and the end user can later select the particular region where he or she is comfortable with making an assumption regarding the relative phases of the hh and vv signals. No ground calibration equipment is necessary, as all important parameters are derived from the data themselves.

Zebker, Howard A.↗

Matrix phased array (MPA) imaging technology for resistance spot welds

A three-dimensional MPA probe has been incorporated with a high speed phased array electronic board to visualize nugget images of resistance spot welds. The primary application area of this battery operated portable MPA ultrasonic imaging system is in the automotive industry which a conventional destructive testing process is commonly adopted to check the quality of resistance spot welds in auto bodies. Considering an average of five-thousand spot welds in a medium size passenger vehicle, the amount of time and effort given to popping the welds and measuring nugget size are immeasurable in addition to the millions of dollars' worth of scrap metals recycled per plant per year. This wasteful labor intensive destructive testing process has become less reliable as auto body sheet metal has transitioned from thick and heavy mild steels to thin and light high strength steels. Consequently, the necessity of developing a non-destructive inspection methodology has become inevitable. In this paper, the fundamental aspects of the current 3-D probe design, data acquisition algorithms, and weld nugget imaging process are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging IR spectrometer, phase 2

The development is examined of a prototype multi-channel infrared imaging spectrometer. The design, construction and preliminary performance is described. This instrument is intended for use with JPL Table Mountain telescope as well as the 88 inch UH telescope on Mauna Kea. The instrument is capable of sampling simultaneously the spectral region of 0.9 to 2.6 um at an average spectral resolution of 1 percent using a cooled (77 K) optical bench, a concave holographic grating and a special order sorting filter to allow the acquisition of the full spectral range on a 128 x 128 HgCdTe infrared detector array. The field of view of the spectrometer is 0.5 arcsec/pixel in mapping mode and designed to be 5 arcsec/pixel in spot mode. The innovative optical design has resulted in a small, transportable spectrometer, capable of remote operation. Commercial applications of this spectrometer design include remote sensing from both space and aircraft platforms as well as groundbased astronomical observations.

Gradie, Jonathan↗

Evaluation of phase-diversity techniques for solar-image restoration

Phase-diversity techniques provide a novel observational method for overcomming the effects of turbulence and instrument-induced aberrations in ground-based astronomy. Two implementations of phase-diversity techniques that differ with regard to noise model, estimator, optimization algorithm, method of regularization, and treatment of edge effects are described. Reconstructions of solar granulation derived by applying these two implementations to common data sets are shown to yield nearly identical images. For both implementations, reconstructions from phase-diverse speckle data (involving multiple realizations of turbulence) are shown to be superior to those derived from conventional phase-diversity data (involving a single realization). Phase-diverse speckle reconstructions are shown to achieve near diffraction-limited resolution and are validated by internal and external consistency tests, including a comparison with a reconstruction using a well-accepted speckle-imaging method.

Paxman, Richard G.↗

Four-dimensional dose reconstruction through in vivo phase matching of cine images of electronic portal imaging device

Purpose: A method is proposed to reconstruct a four-dimensional (4D) dose distribution using phase matching of measured cine images to precalculated images of electronic portal imaging device (EPID). Methods: (1) A phantom, designed to simulate a tumor in lung (a polystyrene block with a 3 cm diameter embedded in cork), was placed on a sinusoidally moving platform with an amplitude of 1 cm and a period of 4 s. Ten-phase 4D computed tomography (CT) images of the phantom were acquired. A planning target volume (PTV) was created by adding a margin of 1 cm around the internal target volume of the tumor. (2) Three beams were designed, which included a static beam, a theoretical dynamic beam, and a planning-optimized dynamic beam (PODB). While the theoretical beam was made by manually programming a simplistic sliding leaf motion, the planning-optimized beam was obtained from treatment planning. From the three beams, three-dimensional (3D) doses on the phantom were calculated; 4D dose was calculated by means of the ten phase images (integrated over phases afterward); serving as “reference” images, phase-specific EPID dose images under the lung phantom were also calculated for each of the ten phases. (3) Cine EPID images were acquired while the beams were irradiated to the moving phantom. (4) Each cine image was phase-matched to a phase-specific CT image at which common irradiation occurred by intercomparing the cine image with the reference images. (5) Each cine image was used to reconstruct dose in the phase-matched CT image, and the reconstructed doses were summed over all phases. (6) The summation was compared with forwardly calculated 4D and 3D dose distributions. Accounting for realistic situations, intratreatment breathing irregularity was simulated by assuming an amplitude of 0.5 cm for the phantom during a portion of breathing trace in which the phase matching could not be performed. Intertreatment breathing irregularity between the time of treatment and the time of planning CT was considered by utilizing the same reduced amplitude when the phantom was irradiated. To examine the phase matching in a humanoid environment, the matching was also performed in a digital phantom (4D XCAT phantom). Results: For the static, the theoretical, and the planning-optimized dynamic beams, the 4D reconstructed doses showed agreement with the forwardly calculated 4D doses within the gamma pass rates of 92.7%, 100%, and 98.1%, respectively, at the isocenter plane given by 3%/3 mm criteria. Excellent agreement in dose volume histogram of PTV and lung-PTV was also found between the two 4D doses, while substantial differences were found between the 3D and the 4D doses. The significant breathing irregularities modeled in this study were found not to be noticeably affecting the reconstructed dose. The phase matching was performed equally well in a digital phantom. Conclusions: The method of retrospective phase determination of a moving object under irradiation provided successful 4D dose reconstruction. This method will provide accurate quality assurance and facilitate adaptive therapy when distinguishable objects such as well-defined tumors, diaphragm, and organs with markers (pancreas and liver) are covered by treatment beam apertures.

60 APPLIED LIFE SCIENCES↗

Invited Review Article: Methods for imaging weak-phase objects in electron microscopy

Contrast has traditionally been produced in electron-microscopy of weak phase objects by simply defocusing the objective lens. There now is renewed interest, however, in using devices that apply a uniform quarter-wave phase shift to the scattered electrons relative to the unscattered beam, or that generate in-focus image contrast in some other way. Renewed activity in making an electron-optical equivalent of the familiar “phase-contrast” light microscope is based in part on the improved possibilities that are now available for device microfabrication. There is also a better understanding that it is important to take full advantage of contrast that can be had at low spatial frequency when imaging large, macromolecular objects. In addition, a number of conceptually new phase-plate designs have been proposed, thus increasing the number of options that are available for development. The advantages, disadvantages, and current status of each of these options is now compared and contrasted. Experimental results that are, indeed, superior to what can be accomplished with defocus-based phase contrast have been obtained recently with two different designs of phase-contrast aperture. Nevertheless, extensive work also has shown that fabrication of such devices is inconsistent, and that their working lifetime is short. The main limitation, in fact, appears to be electrostatic charging of any device that is placed into the electron diffraction pattern. The challenge in fabricating phase plates that are practical to use for routine work in electron microscopy thus may be more in the area of materials science than in the area of electron optics.

36 MATERIALS SCIENCE↗

Moiré deflectometry using the Talbot-Lau interferometer as refraction diagnostic for High Energy Density plasmas at energies below 10 keV

The highly localized density gradients expected in High Energy Density (HED) plasma experiments can be characterized by x-ray phase-contrast imaging in addition to conventional attenuation radiography. Moiré deflectometry using the Talbot-Lau grating interferometer setup is an attractive HED diagnostic due to its high sensitivity to refraction induced phase shifts. We report on the adaptation of such a system for operation in the sub-10 keV range by using a combination of free standing and ultrathin Talbot gratings. This new x-ray energy explored matches well the current x-ray backlighters used for HED experiments, while also enhancing phase effects at lower electron densities. We studied the performance of the high magnification, low energy Talbot-Lau interferometer, for single image phase retrieval using Moiré fringe deflectometry. Our laboratory and simulation studies indicate that such a device is able to retrieve object electron densities from phase shift measurements. Using laboratory x-ray sources from 7 to 15 μm size we obtained accurate simultaneous measurements of refraction and attenuation for both sharp and mild electron density gradients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Eastern Cooperative Oncology Group and American College of Radiology Imaging Network Randomized Phase 2 Trial of Neoadjuvant Preoperative Paclitaxel/Cisplatin/Radiation Therapy (RT) or Irinotecan/Cisplatin/RT in Esophageal Adenocarcinoma: Long-Term Outcome and Implications for Trial Design

Purpose: Toxicity, pathologic complete response, and long-term outcomes are reported for the neoadjuvant therapies assessed in a randomized phase 2 Eastern Cooperative Oncology Group and American College of Radiology Imaging Network trial for operable esophageal adenocarcinoma, staged as II-IVa by endoscopy/ultrasonography (EUS). Methods and Materials: A total of 86 eligible patients began treatment. For arm A, preoperative chemotherapy was cisplatin, 30 mg/m{sup 2}, and irinotecan, 50 mg/m{sup 2}, on day 1, 8, 22, 29 during 45 Gy radiation therapy (RT), 1.8 Gy per day over 5 weeks. Adjuvant therapy was cisplatin, 30 mg/m{sup 2}, and irinotecan, 65 mg/m{sup 2} day 1, 8 every 21 days for 3 cycles. Arm B therapy was cisplatin, 30 mg/m{sup 2}, and paclitaxel, 50 mg/m{sup 2}, day 1, 8, 15, 22, 29 with RT, followed by adjuvant cisplatin, 75 mg/m{sup 2}, and paclitaxel, 175 mg/m{sup 2}, day 1 every 21 days for 3 cycles. Stratification included EUS stage and performance status. Results: In arm A, median overall survival was 35 months, and 5-, 6-, and 7-year survival rates were 46%, 39%, and 35%, respectively, whereas for arm B, they were 21 months and 27%, 27%, and 23%, respectively. Median progression- or recurrence-free survival (PFS) was 39.8 months with a 3-year PFS of 50% for arm A and 12.4 months (P=.046) with 3-year PFS of 28% for arm B. Eighty percent of the observed incidents of progression occurred within 19 months. Survival did not differ significantly by EUS and performance status strata. Conclusions: Long-term survival was similar for both arms and did not appear superior to results achieved with other standard regimens.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase calibration of polarimetric radar images

The problem of phase calibration between polarization channels of an imaging radar is studied. The causes of various types of phase errors due to the radar system architecture and system imperfections are examined. A simple model is introduced to explain the spatial variation in phase error as being due to a displacement between the phase centers of the vertical and horizontal antennas. It is also shown that channel leakage can cause a spatial variation in phase error. Phase calibration using both point and distributed ground targets is discussed and a method for calibrating phase using only distributed target is verified, subject to certain constraints. Experimental measurements using the NADC/ERIM P-3 synthetic-aperture radar (SAR) system and NASA/JPL DC-8 SAR, which operates at C-, L-, and P-bands, are presented. Both of these systems are multifrequency, polarimetric, airborne, SAR systems.

Sheen, Dan R.↗

Neutron Imaging Using Grating Interferometry: Exploiting phase contrast and dark-field imaging for <1μm feature detection in bulk materials (Summary Report)

Radiography is an important non-destructive characterization tool for many LANL missions. Contrast in conventional radiography results from attenuation of the incoming x-ray or neutron beam by the object. Neutrons have a great benefit in detecting light elements (e.g. hydrogen) in the presence of heavier elements and penetrate deeper than X-rays into many materials, but neutron radiography resolution is typically limited to ~50 μm. Cracks, voids, pores and a variety of other features smaller than this resolution are therefore undetectable in attenuation based neutron imaging. However, novel neutron imaging modalities leveraging off of interferometric methods, so-called neutron grating interferometry (NGI), are able to spatially map sub-micron features and interfacial features while also exploiting the neutron’s sensitivity to light elements and isotope specific contrast to enable material characterization otherwise impossible.

36 MATERIALS SCIENCE↗

A Refined Global Segmentation of X-Ray CT Images for Multi-phase Geomaterials

X-ray computed tomography images of three-phase silica sand and glass bead specimens are analyzed and used to evaluate the segmentation performances of Otsu-, and recursion-based multilevel algorithms. A global image segmentation technique that combines iterative and recursive algorithms, namely a refined statistics-based global segmentation is proposed for segmenting multi-phase granular geomaterials. The performance of the proposed algorithm is tested by segmenting partially saturated silica sand and glass bead specimens. For the tested silica sand specimen, the refined statistics method estimated void ratio and degree of saturation were 0.67 and 39.35%. The estimates for the glass bead specimen yielded 0.64 and 43.49%, respectively. The true void ratio (0.66) and degree of saturation (37.71%) were determined with a user-controlled Image processing software package—Image-Pro. It was found that the proposed method estimated the void ratio and the degree of saturation with 1.52 and 4.35 percent errors for the silica sand and with 15.63 and 0.34 percent errors for the glass bead, respectively. The computational time of the proposed method was found to be shorter than other methods considered. Overall, it is concluded that the proposed technique performed better in segmenting three-phase granular geomaterials.

42 ENGINEERING↗

Alignment of low-dose X-ray fluorescence tomography images using differential phase contrast

X-ray fluorescence nanotomography provides unprecedented sensitivity for studies of trace metal distributions in whole biological cells. Dose fractionation, in which one acquires very low dose individual projections and then obtains high statistics reconstructions as signal from a voxel is brought together (Hegerl & Hoppe, 1976), requires accurate alignment of these individual projections so as to correct for rotation stage runout. It is shown here that differential phase contrast at 10.2 keV beam energy offers the potential for accurate cross-correlation alignment of successive projections, by demonstrating that successive low dose, 3 ms per pixel, images acquired at the same specimen position and rotation angle have a narrower and smoother cross-correlation function (1.5 pixels FWHM at 300 nm pixel size) than that obtained from zinc fluorescence images (25 pixels FWHM). The differential phase contrast alignment resolution is thus well below the 700 nm × 500 nm beam spot size used in this demonstration, so that dose fractionation should be possible for reduced-dose, more rapidly acquired, fluorescence nanotomography experiments.

differential phase contrast↗

Fast Atomic-Scale Chemical Imaging of Crystalline Materials and Dynamic Phase Transformations

Chemical imaging at the atomic-scale provides a useful real-space approach to chemically investigate solid crystal structures, and has been recently demonstrated in aberration corrected scanning transmission electron microscopy (STEM). Atomic-scale chemical imaging by STEM using energy-dispersive X-ray spectroscopy (EDS) offers easy data interpretation with a one-to-one correspondence between image and structure but has a severe shortcoming due to the poor efficiency of X-ray generation and collection. As a result, it requires a long acquisition time of typical > few 100 seconds, limiting its potential applications. Here we describe the development of an atomic-scale STEM EDS chemical imaging technique that cuts the acquisition time to one or a few seconds, efficiently reducing the acquisition time by more than 100 times. This method was demonstrated using LaAlO 3 (LAO) as a model crystal. Applying this method to the study of phase transformation induced by electron-beam radiation in a layered lithium transition-metal (TM) oxide, i.e., Li[Li 0.2 Ni 0.2 Mn 0.6 ]O 2 (LNMO), a cathode materials for lithium-ion batteries, we obtained a time-series of the atomic-scale chemical imaging, showing the transformation progressing by preferably jumping of Ni atoms from the TM layers into the Li-layers. The new capability offers an opportunity for temporal, atomic-scale chemical mapping of crystal structures for the investigation of materials susceptible to electron irradiation as well as phase transformation and dynamics at the atomic-scale.

36 MATERIALS SCIENCE↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Topographical and Chemical Imaging of a Phase Separated Polymer Using a Combined Atomic Force Microscopy/Infrared Spectroscopy/Mass Spectrometry Platform

This article describes how the use of a hybrid atomic force microscopy/infrared spectroscopy/mass spectrometry imaging platform was demonstrated for the acquisition and correlation of nanoscale sample surface topography and chemical images based on infrared spectroscopy and mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗