Search NASA⌕ Search

SEARCH · Search NASA

Results for “Patient Support System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

SU-E-T-600: Patient Specific IMRT Verification Using a Phosphor-Screen Based Geometric QA System: A Preliminary Study

Purpose: Raven QA (JPLC, MD) is a unified and comprehensive quality assurance system for QA of TG-142, which use a phosphor screen, a mirror system and a camera. It is to test if this device can be used for IMRT QA dosimetry. Methods: A lung IMRT case is used deliver dose to Raven QA. Accuracy of dose distribution of 5cm slab phantom using Eclipse planning system (Varian) has been confirmed both from a Monte Carlo Simulation and from a MapCheck (SunNuclear) measurement. Geometric distortion and variation of spatial dose response are corrected after background subtraction. A pin-hole grid plate is designed and used to determine the light scatter in the Raven QA box and the spatial dose response. Optic scatter model was not applied in this preliminary study. Dose is normalized to the response of the 10×10 field and the TMR of 5cm depth was considered. Results: Time to setup the device for IMRT QA takes less than 5 minutes as other commercially available devices. It shows excellent dose linearity and dose rate independent, less than 1 %. Background signal, however, changes for different field sizes. It is believed to be due to inaccurate correction of optic scatter. Absolute gamma (5%, 5mm) passing rate was higher than 95%. Conclusion: This study proves that the Raven QA can be used for a patient specific IMRT verification. Part of this study is supported by the Maryland Industrial Partnership Grant.

61 RADIATION PROTECTION AND DOSIMETRY↗

The pressor response to water drinking in humans : a sympathetic reflex?

BACKGROUND: Water drinking increases blood pressure profoundly in patients with autonomic failure and substantially in older control subjects. The mechanism that mediates this response is not known. METHODS AND RESULTS: We studied the effect of drinking tap water on seated blood pressure in 47 patients with severe autonomic failure (28 multiple system atrophy [MSA], 19 pure autonomic failure patients [PAF]). Eleven older controls and 8 young controls served as control group. We also studied the mechanisms that could increase blood pressure with water drinking. Systolic blood pressure increased profoundly with water drinking, reaching a maximum of 33+/-5 mm Hg in MSA and 37+/-7 in PAF mm Hg after 30 to 35 minutes. The pressor response was greater in patients with more retained sympathetic function and was almost completely abolished by trimethaphan infusion. Systolic blood pressure increased by 11+/-2.4 mm Hg in elderly but not in young controls. Plasma norepinephrine increased in both groups. Plasma renin activity, vasopressin, and blood volume did not change in any group. CONCLUSIONS: Water drinking significantly and rapidly raises sympathetic activity. Indeed, it raises plasma norepinephrine as much as such classic sympathetic stimuli as caffeine and nicotine. This effect profoundly increases blood pressure in autonomic failure patients, and this effect can be exploited to improve symptoms due to orthostatic hypotension. Water drinking also acutely raises blood pressure in older normal subjects. The pressor effect of oral water is an important yet unrecognized confounding factor in clinical studies of pressor agents and antihypertensive medications.

Non-NASA Center↗

SU-E-T-04: 3D Dose Based Patient Compensator QA Procedure for Proton Radiotherapy

Purpose: In proton double-scattering radiotherapy, compensators are the essential patient specific devices to contour the distal dose distribution to the tumor target. Traditional compensator QA is limited to checking the drilled surface profiles against the plan. In our work, a compensator QA process was established that assess the entire compensator including its internal structure for patient 3D dose verification. Methods: The fabricated patient compensators were CT scanned. Through mathematical image processing and geometric transformations, the CT images of the proton compensator were combined with the patient simulation CT images into a new series of CT images, in which the imaged compensator is placed at the planned location along the corresponding beam line. The new CT images were input into the Eclipse treatment planning system. The original plan was calculated to the combined CT image series without the plan compensator. The newly computed patient 3D dose from the combined patientcompensator images was verified against the original plan dose. Test plans include the compensators with defects intentionally created inside the fabricated compensators. Results: The calculated 3D dose with the combined compensator and patient CT images reflects the impact of the fabricated compensator to the patient. For the test cases in which no defects were created, the dose distributions were in agreement between our method and the corresponding original plans. For the compensator with the defects, the purposely changed material and a purposely created internal defect were successfully detected while not possible with just the traditional compensator profiles detection methods. Conclusion: We present here a 3D dose verification process to qualify the fabricated proton double-scattering compensator. Such compensator detection process assesses the patient 3D impact of the fabricated compensator surface profile as well as the compensator internal material and structure changes. This research receives funding support from CURA Medical Technologies.

60 APPLIED LIFE SCIENCES↗

SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy

Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43), ii) a MC study using the Penelope2009 code, and iii) RayStretch. To analyse the performance of RayStretch, calcifications located in the prostate lobules covering 11% of the total prostate volume and larger calcifications located in the lobules and underneath the urethra for a total occupied volume of 30% were considered. Three mass densities (1.05, 1.20, and 1.35 g/cm3) were explored for the calcifications. Therefore, 6 different scenarios ranging from small low density calcifications to large high density ones have been discussed. Results: DVH and D90 results given by RayStretch agree within 1% with the full MC simulations. Although no effort has been done to improve RayStretch numerical performance, its present implementation is able to evaluate a clinical implant in a few seconds to the same level of accuracy as a detailed MC calculation. Conclusion: RayStretch is a robust method for heterogeneity corrections in prostate BT supported on TG-43 data. Its compatibility with commercial TPSs and its high calculation speed makes it feasible for use in clinical settings for improving treatment quality. It will allow in a second phase of this project, its use during intraoperative ultrasound planning. This study was partly supported by a fellowship grant from the Spanish Ministry of Education, by the Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156 and by the European Commission within the SeventhFramework Program through ENTERVISION (grant agreement number 264552).

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-08: Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration

Purpose: Intraoperative C-arm cone-beam CT (CBCT) is subject to artifacts arising from patient motion during the fairly long (∼5–20 s) scan times. We present a fiducial free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in geometric calibration. Methods: A 3D-2D registration process was used to register each projection to DRRs computed from the 3D image by maximizing gradient orientation (GO) using the CMA-ES optimizer. The resulting rigid 6 DOF transforms were applied to the system projection matrices, and a 3D image was reconstructed via model-based image reconstruction (MBIR, which accommodates the resulting noncircular orbit). Experiments were conducted using a Zeego robotic C-arm (20 s, 200°, 496 projections) to image a head phantom undergoing various types of motion: 1) 5° lateral motion; 2) 15° lateral motion; and 3) 5° lateral motion with 10 mm periodic inferior-superior motion. Images were reconstructed using a penalized likelihood (PL) objective function, and structural similarity (SSIM) was measured for axial slices of the reconstructed images. A motion-free image was acquired using the same protocol for comparison. Results: There was significant improvement (p < 0.001) in the SSIM of the motion-corrected (MC) images compared to uncorrected images. The SSIM in MC-PL images was >0.99, indicating near identity to the motion-free reference. The point spread function (PSF) measured from a wire in the phantom was restored to that of the reference in each case. Conclusion: The 3D-2D registration method provides a robust framework for mitigation of motion artifacts and is expected to hold for applications in the head, pelvis, and extremities with reasonably constrained operative setup. Further improvement can be achieved by incorporating multiple rigid components and non-rigid deformation within the framework. The method is highly parallelizable and could in principle be run with every acquisition. Research supported by National Institutes of Health Grant No. R01-EB-017226 and academic-industry partnership with Siemens Healthcare (AX Division, Forcheim, Germany).

60 APPLIED LIFE SCIENCES↗

The effects of programmed administration of human parathyroid hormone fragment (1-34) on bone histomorphometry and serum chemistry in rats

PTH treatment can result in dramatic increases in cancellous bone volume in normal and osteopenic rats. However, this potentially beneficial response is only observed after pulsatile treatment; continuous infusion of PTH leads to hypercalcemia and bone abnormalities. The purpose of these studies was to determine the optimal duration of the PTH pulses. A preliminary study revealed that human PTH-(1-34) (hPTH) is cleared from circulation within 6 h after sc administration of an anabolic dose of the hormone (80 microg/kg). To establish the effects of gradually extending the duration of exposure to hPTH without increasing the daily dose, we programmed implanted Alzet osmotic pumps to deliver the 80 microg/kg x day dose of the hormone during pulses of 1, 2, and 6 h/day, or 40 microg/kg x day continuously. Discontinuous infusion was accomplished by alternate spacing of external tubing with hPTH solution and sesame oil. After 6 days of treatment, we evaluated serum chemistry and bone histomorphometry. As negative and positive controls, groups of rats received pumps that delivered vehicle only and 80 microg/kg x day hPTH by daily sc injection, respectively. Dynamic and static bone histomorphometry revealed that the daily sc injection and 1 h/day infusion dramatically increased osteoblast number and bone formation in the proximal tibial metaphysis, whereas longer infusion resulted in systemic side-effects, including up to a 10% loss in body weight, hypercalcemia, and histological changes in the proximal tibia resembling abnormalities observed in patients with chronic primary hyperparathyroidism, including peritrabecular marrow fibrosis and focal bone resorption. Infusion for as little as 2 h/day resulted in minor weight loss and changes in bone histology that were intermediate between sc and continuous administration. The results demonstrate that the therapeutic interval for hPTH exposure is brief, but that programmed administration of implanted hormone is a feasible alternative to daily injection as a route for administration of the hormone.

Non-NASA Center↗

Tumor response parameters for head and neck cancer derived from tumor-volume variation during radiation therapy

Purpose: The main goal of this paper is to reconstruct a distribution of cell survival fractions from tumor-volume variation for a heterogeneous group of head and neck cancer patients and compare this distribution to the data from predictive assays. Methods: To characterize the tumor-volume variation during radiation therapy treatment, the authors use a two-level tumor-volume model of cell population that separates the entire tumor cell population into two subpopulations of viable cells and lethally damaged cells. This parameterized radiobiological model is integrated with a least squares objective function and a simulated annealing optimization algorithm to describe time-dependent tumor-volume variation rates in individual patients. Several constraints have been used in the optimization problem because tumor-volume variation during radiotherapy is described by a sum of exponentials; therefore, the problem of accurately fitting a model to measured data is ill-posed. The model was applied to measured tumor-volume variation curves from a clinical study on tumor-volume variation during radiotherapy for 14 head and neck cancer patients in which an integrated CT/linear particle accelerator (LINAC) system was used for tumor-volume measurements. Results: The two-level cell population tumor-volume modeling is capable of describing tumor-volume variation throughout the entire treatment for 11 of the 14 patients. For three patients, the tumor-volume variation was described only during the initial part of treatment, a fact that may be related to the neglected hypoxia in the two-level approximation. The predicted probability density distribution for the survival fractions agrees with the data obtained using in vitro studies with predictive assays. The mean value 0.35 of survival fraction obtained in this study is larger than the value 0.32 from in vitro studies, which could be expected because of greater repair in vivo. The mean half-life obtained in this study for the head-and-neck squamous cell carcinoma (SCC) is equal to 3.8 mean potential doubling times, which agrees with 4.0 mean potential doubling times obtained previously for lung SCC. Conclusions: The distribution of cell survival fractions obtained in this study support the hypothesis that the tumor-volume variation during radiotherapy treatment for head and neck cancer can be described by the two-level cell population tumor-volume model. This model can be used for in vivo evaluation of patient-specific radiobiological parameters that are needed for tumor-control probability evaluation.

60 APPLIED LIFE SCIENCES↗

MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure the delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability metrics: Different cultures/practices affecting the effectiveness of methods and metrics. Show examples of quality assurance workflows, Statistical process control, that monitor the treatment planning and delivery process to identify errors. To learn to identify and prioritize risks and QA procedures in radiation oncology. Try to answer the question: Can a quality assurance program aided by quality assurance metrics help minimize errors and ensure safe treatment delivery. Should such metrics be institution specific.

07 ISOTOPE AND RADIATION SOURCES↗

What can posturography tell us about vestibular function?

Patients with balance disorders want answers to the following basic questions: (1) What is causing my problem? and (2) What can be done about my problem? Information to fully answer these questions must include status of both sensory and motor components of the balance control systems. Computerized dynamic posturography (CDP) provides quantitative assessment of both sensory and motor components of postural control along with how the sensory inputs to the brain interact. This paper reviews the scientific basis and clinical applications of CDP. Specifically, studies describing the integration of vestibular inputs with other sensory systems for postural control are briefly summarized. Clinical applications, including assessment, rehabilitation, and management are presented. Effects of aging on postural control along with prevention and management strategies are discussed.

NASA Discipline Neuroscience↗

Neurogenic orthostatic hypotension: a double-blind, placebo-controlled study with midodrine

PURPOSE: To investigate the efficacy and safety of midodrine for treatment of patients with orthostatic hypotension due to autonomic failure. PATIENTS: Ninety-seven patients with orthostatic hypotension were randomized in a 4-week, double-blinded, placebo-controlled study with a 1-week placebo run-in period. Patients ranged in age from 22 to 86 years (mean: 61 years). METHODS: After a 1-week run-in phase, either placebo or midodrine at a dose of 2.5 mg, 5 mg, or 10 mg was administered three times a day for 4 weeks. Both the placebo group and the 2.5-mg midodrine group received constant doses throughout the double-blind phase. The patients receiving 5 mg or 10 mg of midodrine were given doses that were increased at weekly intervals by 2.5-mg increments until the designated dose was reached. Efficacy evaluations were based on an improvement at 1-hour postdose in standing systolic blood pressure and in symptoms of orthostatic hypotension (syncope, dizziness/lightheadedness, weakness/fatigue, and low energy level). RESULTS: Midodrine (10 mg) increased standing systolic blood pressure by 22 mm Hg (28%, p < 0.001 versus placebo). Midodrine improved (p < 0.05) the following symptoms of orthostatic hypotension compared to placebo: dizziness/lightheadedness, weakness/fatigue, syncope, low energy level, impaired ability to stand, and feelings of depression. The overall side effects were mainly mild to moderate. One or more side effects were reported by 22% of the placebo group compared with 27% of the midodrine-treated group. Scalp pruritus/tingling, which was reported by 10 of 74 (13.5%) of the midodrine-treated patients, was most frequent. Other reported side effects included supine hypertension (8%) and feelings of urinary urgency (4%). CONCLUSION: We conclude that midodrine is an effective and well-tolerated treatment for moderate-to-severe orthostatic hypotension associated with autonomic failure.

NASA Discipline Number 14-10↗

SU-F-J-05: The Effect of Air Pockets in the Urinary Bladder During Bladder Hyperthermia Treatment

Purpose: Hyperthermia combined with Mitomycin C is used for the treatment of non-muscle invasive bladder cancer (NMIBC), using a phased array system of microwave antennas for bladder heating. Often some air is present in the bladder, which effectively blocks the microwave radiation, potentially preventing proper treatment of that part of the bladder. Air can be a relevant fraction of the bladder content and large air pockets are expected to have a noticeable influence on achieved temperatures. Methods: We analysed 14 NMIBC patients treated at our institute with our AMC-4 hyperthermia device with four 70MHz antennas around the pelvis. A CT scan was made after treatment and a physician delineated the bladder on the CT scan. On the same scan, the amount of air present in the bladder was delineated. Using our in-house developed hyperthermia treatment planning system, we simulated the treatment using the clinically applied device settings. We did this once with the air pocket delineated on the CT scan, and once with the same volume filled with bladder tissue. Results: The patients had on average 4.2ml (range 0.8–10.1ml) air in the bladder. The bladder volume was delineated by the physician, that is including air pocket and bladder wall, was on average 253ml (range 93–452ml). The average volume in which changes exceeded 0.25°C was 22ml (range 0–108 ml), with the bladder being up to 2°C cooler when an air pocket was present. Except for extreme cases, there was no evident relation between the quantity of air and the difference in temperature. Conclusion: The effect of an air pocket in the bladder during bladder hyperthermia treatment varies strongly between patients. Generally, this leads to lower temperatures in the bladder, potentially affecting treatment quality, and suggesting that care need be taken to minimise the size of air pockets during hyperthermia treatments. The KWF Dutch Cancer Society financially supported this work, grant UVA 2012-5539.

60 APPLIED LIFE SCIENCES↗

pN0(i+) Breast Cancer: Treatment Patterns, Locoregional Recurrence, and Survival Outcomes

Purpose: To examine treatment patterns, recurrence, and survival outcomes in patients with pN0(i+) breast cancer. Methods and Materials: Subjects were 5999 women with AJCC (6th edition) pT1-3, pN0-N1a, M0 breast cancer diagnosed between 2003 and 2006. Of these, 4342 (72%) had pN0, 96 (2%) had pN0(i+), 349 (6%) had pNmic (micrometastases >0.2 mm to ≤2 mm), and 1212 (20%) had pN1a (1-3 positive macroscopic nodes) disease. Treatment characteristics and 5-year Kaplan-Meier local recurrence, regional recurrence (RR), locoregional recurrence (LRR), and overall survival were compared between nodal subgroups. Multivariable analysis was performed using Cox regression modeling. A 1:3 case-match analysis examined outcomes in pN0(i+) cases compared with pN0 controls matched for similar tumor and treatment characteristics. Results: Median follow-up was 4.8 years. Adjuvant systemic therapy use increased with nodal stage: 81%, 92%, 95%, and 94% in pN0, pN0(i+), pNmic, and pN1a disease, respectively (P<.001). Nodal radiation therapy (RT) use also increased with nodal stage: 1.7% in pN0, 27% in pN0(i+), 33% in pNmic, and 63% in pN1a cohorts (P<.001). Five-year Kaplan-Meier outcomes in pN0 versus pN0(i+) cases were as follows: local recurrence 1.7% versus 3.7% (P=.20), RR 0.5% versus 2.2% (P=.02), and LRR 2.1% versus 5.8% (P=.02). There were no RR events in 26 patients with pN0(i+) disease who received nodal RT and 2 RR events in 70 patients who did not receive nodal RT. On multivariable analysis, pN0(i+) was not associated with worse locoregional control or survival. On case-match analysis, LRR and overall survival were similar between pN0(i+) and matched pN0 counterparts. Conclusions: Nodal involvement with isolated tumor cells is not a significant prognostic factor for LRR or survival in this study's multivariable and case-match analyses. These data do not support the routine use of nodal RT in the setting of pN0(i+) disease. Prospective studies are needed to define optimal locoregional management for women with pN0(i+) breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Idiopathic orthostatic intolerance and postural tachycardia syndromes

Upright posture imposes a substantial gravitational stress on the body, for which we are able to compensate, in large part because of the autonomic nervous system. Alteration in autonomic function, therefore, may lead to orthostatic intolerance. On one extreme, patients with autonomic failure caused by degenerative loss of autonomic function are severely disabled by orthostatic hypotension and may faint whenever they stand up. Fortunately, such patients are relatively rare. On the other hand, disabling orthostatic intolerance can develop in otherwise normal young people. These patients can be severely impaired by symptoms of fatigue, tachycardia, and shortness of breath when they stand up. The actual incidence of this disorder is unknown, but these patients make up the largest group of patients referred to centers that specialize in autonomic disorders. We will review recent advances made in the understanding of this condition, potential pathophysiological mechanisms that contribute to orthostatic intolerance, therapeutic alternatives currently available for the management of these patients, and areas in which more research is needed.

Review↗

Hypovolemia in syncope and orthostatic intolerance role of the renin-angiotensin system

PURPOSE: Orthostatic intolerance is the cause of significant disability in otherwise normal patients. Orthostatic tachycardia is usually the dominant hemodynamic abnormality, but symptoms may include dizziness, visual changes, discomfort in the head or neck, poor concentration, fatigue, palpitations, tremulousness, anxiety and, in some cases, syncope. It is the most common disorder of blood pressure regulation after essential hypertension. There is a predilection for younger rather than older adults and for women more than men. Its cause is unknown; partial sympathetic denervation or hypovolemia has been proposed. METHODS AND MATERIALS: We tested the hypothesis that reduced plasma renin activity, perhaps from defects in sympathetic innervation of the kidney, could underlie a hypovolemia, giving rise to these clinical symptoms. Sixteen patients (14 female, 2 male) ranging in age from 16 to 44 years were studied. Patients were enrolled in the study if they had orthostatic intolerance, together with a raised upright plasma norepinephrine (> or = 600 pg/mL). Patients underwent a battery of autonomic tests and biochemical determinations. RESULTS: There was a strong positive correlation between the blood volume and plasma renin activity (r = 0.84, P = 0.001). The tachycardic response to upright posture correlated with the severity of the hypovolemia. There was also a correlation between the plasma renin activity measured in these patients and their concomitant plasma aldosterone level. CONCLUSIONS: Hypovolemia occurs commonly in orthostatic intolerance. It is accompanied by an inappropriately low level of plasma renin activity. The degree of abnormality of blood volume correlates closely with the degree of abnormality in plasma renin activity. Taken together, these observations suggest that reduced plasma renin activity may be an important pathophysiologic component of the syndrome of orthostatic intolerance.

Non-NASA Center↗

Leveraging large language models to automate the identification of healthcare access barriers for veterans

Objective: To develop and evaluate an automated system for identifying healthcare barriers focusing on transportation issues in veterans’ clinical notes using large language models (LLMs) and to assess the impact of different prompting strategies on classification performance and explanation consistency. Methods: We developed a hybrid system combining pattern matching for templated notes with LLM analysis for free-text notes. Using 2000 manually annotated clinical notes, we compared four prompting strategies (dual-role short, dual-role long, analysis-first, analysis-only) across Mistral-7B and Llama-3.1 models. We evaluated classification performance using standard metrics and assessed explanation consistency through embedding similarity analysis. Results: The analysis-first strategy achieved superior performance, with Mistral-7B reaching an F1 score of 0.914, outperforming traditional machine learning approaches (GBM: 0.786, BERT: 0.811). LLMs demonstrated higher explanation consistency within models (mean cosine similarity 0.887–0.908) compared to cross-model similarities (0.767–0.872). Pattern matching successfully handled 6.7% of templated notes deterministically. Mistral-7B showed greater internal consistency but higher abstention rates compared to Llama-3.1. Conclusion: Requiring LLMs to analyze evidence before classification improves both accuracy and explanation consistency for identifying transportation barriers in clinical notes. This approach enables automated barrier detection at scale while providing clinically relevant explanations, supporting both population-level healthcare planning and individual patient care decisions.

Healthcare access barriers↗

Development of a novel, physiologically relevant cytotoxicity model: Application to the study of chemotherapeutic damage to mesenchymal stromal cells

There is an increasing need for development of physiologically relevant in-vitro models for testing toxicity, however determining toxic effects of agents which undergo extensive hepatic metabolism can be particularly challenging. If a source of such metabolic enzymes is inadequate within a model system, toxicity from prodrugs may be grossly underestimated. Conversely, the vast majority of agents are detoxified by the liver, consequently toxicity from such agents may be overestimated. In this study we describe the development of a novel in-vitro model, which could be adapted for any toxicology setting. The model utilises HepG2 liver spheroids as a source of metabolic enzymes, which have been shown to more closely resemble human liver than traditional monolayer cultures. A co-culture model has been developed enabling the effect of any metabolised agent on another cell type to be assessed. This has been optimised to enable the study of damaging effects of chemotherapy on mesenchymal stem cells (MSC), the supportive stem cells of the bone marrow. Several optimisation steps were undertaken, including determining optimal culture conditions, confirmation of hepatic P450 enzyme activity and ensuring physiologically relevant doses of chemotherapeutic agents were appropriate for use within the model. The developed model was subsequently validated using several chemotherapeutic agents, both prodrugs and active drugs, with resulting MSC damage closely resembling effects seen in patients following chemotherapy. Minimal modifications would enable this novel co-culture model to be utilised as a general toxicity model, contributing to the drive to reduce animal safety testing and enabling physiologically relevant in-vitro study. -- Highlights: ► An in vitro model was developed for study of drugs requiring hepatic metabolism ► HepG2 spheroids were utilised as a physiologically relevant source of liver enzymes ► The model was optimised to enable study of chemotherapeutic damage to the bone marrow ► Minor modifications would enable application as a general toxicity model.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Percutaneous Vertebroplasty in Multiple Myeloma: Prospective Long-Term Follow-Up in 106 Consecutive Patients

Purpose: Percutaneous vertebroplasty (PV) is a minimally invasive procedure involving the injection of bone cement within a collapsed vertebral body. Although this procedure was demonstrated to be effective in osteoporosis and metastases, few studies have been reported in cases of multiple myeloma (MM). We prospectively evaluated the safety and efficacy of PV in the treatment of vertebral compression fractures (VCFs) resulting from MM. Materials and Methods: PV was performed in 106 consecutive MM patients who had back pain due to VCFs, the treatment of which had failed conservative therapies. Follow-up (28.2 {+-} 12.1 months) was evaluated at 7 and 15 days as well as at 1, 3, 6, 12, 18, and every 6 months after PV. Visual analog scale (VAS) pain score, opioid use, external brace support, and Oswestry Disability Index (ODI) score were recorded. Results: The median pretreatment VAS score of 9 (range 4-10) significantly (P < 0.001) decreased to 1 (range 0-9) after PV. Median pre-ODI values of 82% (range 36-89%) significantly improved to 7% (range 0-82%) (P < 0.001). Differences in pretreatment and posttreatment use of analgesic drug were statistically significant (P < 0.001). The majority of patients (70 of 81; 86%) did not use an external brace after PV (P < 0.001). Conclusion: PV is a safe, effective, and long-lasting procedure for the treatment of vertebral compression pain resulting from MM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗