Fluid flow and heat convection studies for actively cooled airframes

The work done during the progress report period from May-October 1992 is summarized. The effect of wall thermal boundary conditions on flows over a step or rib when repeated rib roughness is used for heating augmentation is examined. In numerical investigations of various such laminar and turbulent flows, the local heat transfer coefficients on a forward-facing step or on a rib were found to be very sensitive to the wall thermal boundary condition. For the computation of constant property laminar flow, the wall thermal boundary conditions were either a uniform heat flux or a uniform temperature. Results (Nusselt number and isotherms) of the studies are included. The second part of the work consisted of using PHOENICS to solve the conjugate heat transfer problem of flow over a rib in channel. Finally, the algebraic stress model in the TEAM (Turbulent Elliptic Algorithm-Manchester) code was tested for jet impingement flow, but there needs to be an addition of the energy equation to the code.

Mills, A. F.↗

Issues of Long-Term Cryogenic Propellant Storage in Microgravity

Modern multi-layer insulation (MLI) allows to sharply reduce the heat leak into cryogenic propellant storage tanks through the tank surface and, as a consequence, significantly extend the storage duration. In this situation the MLI penetrations, such as support struts, feed lines, etc., become one of the most significant challenges of the tanks heat management. This problem is especially acute for liquid hydrogen (LH2) storage, since currently no efficient cryocoolers exist that operate at very low LH2 temperatures (20K). Even small heat leaks under microgravity conditions and over the period of many months give rise to a complex slowly-developing, large-scale spatiotemporal physical phenomena in a multi-phase liquid-vapor mixture. These phenomena are not well-understood nor can be easily controlled. They can be of a potentially hazardous nature for long-term on-orbital cryogenic torage, propellant loading, tank chilldown, engine restart, and other in-space cryogenic fluid management operations. To support the engineering design solutions that would mitigate these effects a detailed physics-based analysis of heat transfer, vapor bubble formation, growth, motion, coalescence and collapse is required in the presence of stirring jets of different configurations and passive cooling devices such as MLI, thermodynamic vent system, and vapor-cooled shield. To develop physics-based models and correlations reliable for microgravity conditions and long-time scales there is a need for new fundamental data to be collected from on-orbit cryogenic storage experiments. Our report discusses some of these physical phenomena and the design requirements and future studies necessary for their mitigation. Special attention is payed to the phenomena occurring near MLI penetrations.

Muratov, C. B.↗

Thermodynamic balance of three-dimensional stratospheric winds derived from a data assimilation procedure

The NASA/Goddard three-dimensional chemistry and transport model is driven by winds from a stratospheric data assimilation system. Synoptic- and planetary-scale patterns, apparent in satellite observations of trace constituents, are successfully reproduced for seasonal integrations. As model integrations proceed, however, the quality of simulations decreases, and systematic differences between calculation and measurement appear. The differences are explained by examining the zonal-mean residual circulation. The vertical velocity w-bar (sup star) is calculated two ways: (1) from the diabatic heating rates and temperature tendency and (2) from the Eulerian vertical velocity and the horizontal eddy heat flux convergence. The results from these calculations differ substantially. Periodic insertion of observational data during the assimilation process continually shocks the general circulation model and produces these differences, which leads to an overestimate of the mean vertical heat and cconstituent transport. Such differences are expected to be general to all data assimilation products. This interpretation is corroborated by two-dimensional (2D) model calculations. When w-bar(sup star) is calculated from (2), the 2D ozone evolution is unrealistic and qualitatively similar to the 3D model simulation. The 2D ozone evolution is reasonable when w-bar (sup star) from (1).

Weaver, Clark J.↗

Periodic Cellular Structure Technology for Shape Memory Alloys

Shape memory alloys are being considered for a wide variety of adaptive components for engine and airframe applications because they can undergo large amounts of strain and then revert to their original shape upon heating or unloading. Transition45 Technologies, Inc., has developed an innovative periodic cellular structure (PCS) technology for shape memory alloys that enables fabrication of complex bulk configurations, such as lattice block structures. These innovative structures are manufactured using an advanced reactive metal casting technology that offers a relatively low cost and established approach for constructing near-net shape aerospace components. Transition45 is continuing to characterize these structures to determine how best to design a PCS to better exploit the use of shape memory alloys in aerospace applications.

Chen, Edward Y.↗

The atmospheric heat budget over the western part of the Tibetan plateau during MONEX, 1979

The heat sources over the western part of the Tibetan Plateau for the period from May 19-August 31, 1979 are calculated. The use of the direct method to compute the total atmospheric heat source is examined. The values for the heat source over western, northwestern, and southwestern Tibet are presented. It is concluded that the atmospheric heat source is smaller during the summer than had been previously estimated; this difference is due to reduced drag coefficients. The northwestern and southwestern heat source values are compared, and it is observed that the northwestern heat source is independent on sensible heating and the southwestern heat source relates to the latent heat (LH). The calculated values correlate with the surface hydrology of these two regions. Time series analyses of the heat source components over the southwestern region reveal that LH is the primary modulator of the total atmospheric heat sources. The relation between the vertical heat distribution and Indian summer monsoons is studied.

Feng, Z.↗

Pumped Thermal Electricity Storage with Supercritical CO2 Cycles and Solar Heat Input

Pumped Thermal Electricity Storage (PTES) is an energy storage device that uses grid electricity to drive a heat pump that generates hot and cold storage reservoirs. This thermal potential is later used to power a heat engine and return electricity to the grid. In this article, a PTES variant that uses supercritical carbon dioxide (sCO2) as the working fluid is introduced. sCO2-PTES cycles have higher work ratios and power densities than the systems based on ideal gases that have been investigated to date. Furthermore, sCO2- PTES cycles may achieve higher round-trip efficiencies for a given hot storage temperature (up to 78% at 560°C). The sensitivity of PTES cycles to loss factors such as isentropic efficiencies and temperature differences between the power cycle and storage fluid is investigated. A second concept whereby an sCO2- PTES cycle is integrated with concentrating solar power (CSP) is introduced. This concept ‘time-shifts’ the recompression of an sCO2 recompression cycle to a period of lower electricity prices and stores the heat. When solar heat is dispatched, the recompressor may be avoided as the required heat is obtained from storage, thereby leading to increased heat engine efficiencies. The net work output of this integrated system is 10-18% greater than the conventional recompression cycle. Combining PTES with a CSP power cycle is therefore shown to improve the dispatch of solar heat as well as providing electricity storage services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Tropical Warm Pool Surface Heat Budgets and Temperature: Contrasts Between 1997-98 El Nino and 1998-99 La Nina

Seasonal and interannual variations of the net surface heating F(sub NET) and sea surface temperature tendency (T(sub s)/dt) in the tropical eastern Indian and western Pacific Oceans are studied. The surface heat fluxes are derived from the Special Sensor Microwave/Imager and Japanese Geostationary Meteorological Satellite radiance measurements for the period October 1997-September 2000. It is found that the magnitude of solar heating is lager than that of evaporative cooling, but the spatial variation of the latter is significantly large than the former. As a result, the spatial variations of seasonal and interannual variability of F(sub NET), follow closely that of evaporative cooling. Seasonal variations of F(sub NET) and T(sub s)/dt are significantly correlated, except for the equatorial western Pacific. The high correlation is primarily attributable to high correlation between seasonal cycles of solar heating and T(sub s)/dt. The change of F(sub NET) between 1997-98 El Nino and 1998-99 La Nina is significantly larger in the tropical eastern Indian Ocean than tropical western Pacific. For the former region, the reduced evaporative cooling arising from weakened winds during the El Nino is generally associated with enhanced solar heating due to decreased cloudiness, and thus increases the interannual variability of F(sub NET). For the latter region, the reduced evaporative cooling due to weakened winds is generally associated with but exceeds the reduced solar heating arising from increased cloudiness, and vise versa. Thus the interannual variability of F(sub NET) is reduced due to this offsetting effect. Interannual variations of F(sub NET) and T(sub s)/dt have very low correlation. This is most likely related to interannual variability of ocean dynamics, which includes the variations of solar radiation penetrating through oceanic mixed layer, upwelling of cold thermocline water, Indonesian throughflow for transporting heat from the Pacific to Indian Ocean, and interhemispheric transport in the Indian Ocean.

Chou, Shu-Hsien↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60°C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant: Preprint

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99 ®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60 °C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

In situ TEM observation of calcium silicate hydrate nanostructure at high temperatures

Fire poses a substantial threat to concrete structures because calcium silicate hydrate (C-S-H) is not thermally stable at high temperatures. Herein, in situ TEM at temperatures from 20 to 800 °C was conducted to study the thermal-induced structural changes in C-S-H. We captured C-S-H shrinks at an average rate of 0.02 μm{sup 2}/{sup o}C upon heating with three stages observed, including induction, constant, and rapid periods. Our observation revealed that an 800 nm pore could be healed during pore structure evolution owing to the reconstruction and deformation among C-S-H blocks. The Ca/Si ratio was dropped at higher temperatures because of the leakage of calcium ions from the C-S-H structure to form CaO precipitates. The temperature-driven phase transformation and degradation were also detected using electron diffraction that C-S-H was transformed into metastable calcium silicate minerals above 800 °C. This work provides insights into the nanoscale transformation of C-S-H at high temperatures.

36 MATERIALS SCIENCE↗

A Numerical Study of the Effect of Wake Passing on Turbine Blade Film Cooling

Time-accurate and steady three-dimensional viscous turbulent numerical simulations were performed to study the effect of upstream blade wake passing unsteadiness on the performance of film cooling on a downstream axial turbine blade. The simulations modeled the blade as spanwise periodic and of infinite span. Both aerodynamic and heat transfer quantities were explored. A showerhead film cooling arrangement typical of modern gas turbine engines was employed. Showerhead cooling was studied because of its anticipated strong sensitivity to upstream flow fluctuations. The wake was modeled as a region of zero axial velocity on the upstream computational boundary which translated with each iteration. This model is compatible with a planned companion experiment in which the wakes will be produced by a rotating row of cylindrical rods upstream of an annular turbine cascade. It was determined that a steady solution with appropriate upstream swirl and stagnation pressure predicted the span-average film effectiveness quite well. The major difference is a 2 to 3 percent overprediction of span-average film effectiveness by the steady simulation on the pressure surface and in the showerhead region. Local overpredictions of up to 8 percent were observed in the showerhead region. These differences can be explained by the periodic relative lifting of the boundary layer and enhanced mixing in the unsteady simulations.

Heidmann, James D.↗

On the Generation of Weddell Sea Polynyas in a High-Resolution Earth System Model

Larger Weddell Sea polynyas (WSPs), differentiated in this study from the smaller Maud Rise Polynyas (MRPs), forming to the east of the prime meridian in the proximity of the Maud Rise seamount, have last been observed in the 1970s. We investigate WSPs that grow realistically out of MRPs in a high-resolution (HR) preindustrial simulation with the Energy Exascale Earth System Model version 0.1. The formation of MRPs requires HR to simulate the detailed flow around Maud Rise, while the realistic formation of WSPs requires a model to produce MRPs. Furthermore, WSPs tend to follow periods of a prolonged build-up of a heat reservoir at depth and weakly negative wind-stress curl in association with the core of the southern hemisphere westerlies at an anomalously northern position. While this scenario also leads to drier conditions over the central Weddell Sea, which some literature claims to be a necessary condition for the formation of WSPs, our model results indicate that open-ocean polynyas do not occur during periods of weakly negative wind-stress curl despite drier atmospheric conditions. Our study supports the hypothesis noted in earlier studies that a shift from a weakly negative to a strongly negative wind-stress curl over the Weddell Sea is a prerequisite for WSPs to form, together with a large heat reservoir at depth. However, the ultimate trigger is a pronounced MRP; whose associated convection creates high surface salinity anomalies that propagate westward with the flow of the Weddell Gyre. If large enough, these anomalies trigger the formation of a WSP and a pulse of newly formed Antarctic Bottom Water.

54 ENVIRONMENTAL SCIENCES↗

High-temperature thermal storage systems for advanced solar receivers materials selections

Advanced space power systems that use solar energy and Brayton or Stirling heat engines require thermal energy storage (TES) systems to operate continuously through periods of shade. The receiver storage units, key elements in both Brayton and Stirling systems, are designed to use the latent heat of fusion of phase-change materials (PCMs). The power systems under current consideration for near-future National Aeronautics and Space Administration space missions require working fluid temperatures in the 1100 to 1400 K range. The PCMs under current investigation that gave liquid temperatures within this range are the fluoride family of salts. However, these salts have low thermal conductivity, which causes large temperature gradients in the storage systems. Improvements can be obtained, however, with the use of thermal conductivity enhancements or metallic PCMs. In fact, if suitable containment materials can be found, the use of metallic PCMs would virtually eliminate the orbit associated temperature variations in TES systems. The high thermal conductivity and generally low volume change on melting of germanium and alloys based on silicon make them attractive for storage of thermal energy in space power systems. An approach to solving the containment problem, involving both chemical and physical compatibility, preparation of NiSi/NiSi2, and initial results for containment of germanium and NiSi/NiSi2, are presented.

Wilson, D. F.↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

It's All About the Envelope: Prioritizing Envelope Upgrades for Electrification of Cold Climate Homes

Building decarbonization via electrification on a clean grid is the most promising climate solution proposed to date for the building sector. In cold climate zones, building electrification will be driven in large part by moving from natural gas space heating to cold climate heat pumps (CCHPs). CCHPs are commercially available today, including economical cold climate air source heat pumps (ccASHPs). But there's one big problem - wide-scale adoption of ccASHPs will dramatically increase winter peak electricity demand, even with the highest efficiency ccASHP products. Furthermore, cold climate space heating loads will drive unprecedented electric system peaks during the lowest periods of renewable generation and are likely to overwhelm existing distribution systems. This scenario is avoidable by coupling electrification with building envelope upgrades to reduce peak heating loads. This paper presents a model, built from home energy audit and research data sets, that quantifies the above challenges. Results demonstrate how weatherization efforts coupled with additional high-performance envelope upgrade measures can prepare the building stock for electrification and show the benefit these measures can bring to future utility operations. Much of this envelope upgrade work is cost-effective, according to conservative cost-benefit testing and program successes to date, and is coupled with substantial non-energy benefits. However, persistent market barriers have made scaling of envelope retrofit work challenging for decades, suggesting additional policy support is required. Lessons learned from previous policy experience, combined with new technology and administrative support, create exciting potential for this decarbonization climate solution.

air sealing↗