CORROSION TESTING IN SIMULATED TANK SOLUTIONS

Three simulated waste solutions representing wastes from tanks SY-102 (high nitrate, modified to exceed guidance limits), AN-107, and AY-102 were supplied by PNNL. Out of the three solutions tested, both optical and electrochemical results show that carbon steel samples corroded much faster in SY-102 (high nitrate) than in the other two solutions with lower ratios of nitrate to nitrite. The effect of the surface preparation was not as strong as the effect of solution chemistry. In areas with pristine mill-scale surface, no corrosion occurred even in the SY-102 (high nitrate) solution, however, corrosion occurred in the areas where the mill-scale was damaged or flaked off due to machining. Localized corrosion in the form of pitting in the vapor space of tank walls is an ongoing challenge to overcome in maintaining the structural integrity of the liquid waste tanks at the Savannah River and Hanford Sites. It has been shown that the liquid waste condensate chemistry influences the amount of corrosion that occurs along the walls of the storage tanks. To minimize pitting corrosion, an effort is underway to gain an understanding of the pitting response in various simulated waste solutions. Electrochemical testing has been used as an accelerated tool in the investigation of pitting corrosion. While significant effort has been undertaken to evaluate the pitting susceptibility of carbon steel in various simulated waste solutions, additional effort is needed to evaluate the effect of liquid waste supernates from six Hanford Site tanks (AY-101, AY-102, AN-102, AN-107, SY-102 (high Cl{sup -}), and SY-102 (high nitrate)) on carbon steel. Solutions were formulated at PNNL to replicate tank conditions, and in the case of SY-102, exceed Cl{sup -} and NO{sub 3}{sup -} conditions, respectively, to provide a contrast between in and out of specification limits. The majority of previous testing has been performed on pristine polished samples. To evaluate the actual tank carbon steel surface, efforts are needed to compare the polished surfaces to corroded and mill-scale surfaces, which are more likely to occur in application. Additionally, due to the change in liquid waste levels within the tanks, salt deposits are highly likely to be present along the tank wall. When the level of the tank decreases, a salt deposit will form as the solution evaporates. The effects of this pre-existing salt, or supernate deposit, are unknown at this time on the corrosion effect and thus require investigation. Additionally, in the presence of radiation, moist air undergoes radiolysis, forming a corrosive nitric acid condensate. This condensate could accelerate the corrosion process in the vapor space. To investigate this process, an experimental apparatus simulating the effects of radiation was designed and constructed to provide gamma irradiation while coupons are exposed to a simulate tank solution. Additionally, ammonia vapors will also be introduced to further represent the tank environment.

36 MATERIALS SCIENCE↗

Vapor Space Corrosion Testing Simulating The Environment Of Hanford Double Shell Tanks

As part of an integrated program to better understand corrosion in the high level waste tanks, Hanford has been investigating corrosion at the liquid/air interface (LAI) and at higher areas in the tank vapor space. This current research evaluated localized corrosion in the vapor space over Hanford double shell tank simulants to assess the impact of ammonia and new minimum nitrite concentration limits, which are part of the broader corrosion chemistry limits. The findings from this study showed that the presence of ammonia gas (550 ppm) in the vapor space is sufficient to reduce corrosion over the short-term (i.e. four months) for a Hanford waste chemistry (SY102 High Nitrate). These findings are in agreement with previous studies at both Hanford and SRS which showed ammonia gas in the vapor space to be inhibitive. The presence of ammonia in electrochemical test solution, however, was insufficient to inhibit against pitting corrosion. The effect of the ammonia appears to be a function of the waste chemistry and may have more significant effects in waste with low nitrite concentrations. Since high levels of ammonia were found beneficial in previous studies, additional testing is recommended to assess the necessary minimum concentration for protection of carbon steel. The new minimum R value of 0.15 was found to be insufficient to prevent pitting corrosion in the vapor space. The pitting that occurred, however, did not progress over the four-month test. Pits appeared to stop growing, which would indicate that pitting might not progress through wall.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WRPS Hanford Update [Slides]

The purpose of this report is to coordinate with the staff from WRPS, the current contract holder for operations at the Hanford site to better inform design decisions for the Autonomous systems for Hanford waste tank handling project. The project goals are to support risk reduction associated with monitoring, inspection and mapping of Hanford tank underground pits and includes: 1. A pit mock-up demonstration of Idaho National Laboratory’s (INL) Autonomous Pit Exploration System (APES) technology, which has two configurations: A. The Autonomous Robotic Arm, which is a proposed collaboration with Florida International University (FIU) and has capabilities to visually inspect, monitor, map and conduct simple tool manipulation tasks in the tank pits, and B. The robotic crawler configuration, which has capabilities to deploy to the bottom of the pits and conduct closer and bottom-up visual inspections. 2. An Implementation Plan that identifies Hanford site-wide application of the INL remote robotics technologies to enhance the performance of the tank farm systems and the characterization of the waste they contain to mitigate risk and optimize the overall waste mission. 3. A first-of-a-kind environmental digital twin will be produced. Digital twins to date require permanently installed sensors in order to produce asset specific predictions. This project will use the intermittent signals during inspections from deployed sensors on robotic systems to produce the data sets used by AI/ML to enable predictions of issues on tanks.

42 - ENGINEERING↗

Aging Hanford Nuclear Waste Using Carbon Dioxide to Evaluate Corrosion at Lower pH Limits - 18467

Samples of Hanford Nuclear Reservation (HNR) tank waste and simulated Hanford tank waste were exposed to carbon dioxide gas (CO{sub 2}) in the laboratory in order to decrease the pH of the solution. Sodium hydroxide is required to be added to some tanks according to waste handling specifications to keep tanks protected from pitting corrosion, but the maximum-allowed volume in some tanks is currently approaching capacity. Decreasing the pH of tank solutions using CO{sub 2} gas mimics the environmental exposure chemistry, does not add sodium, and allows for testing on solutions currently categorized as out-of-specification according to technical waste handling documents. Legacy alloy A537 Class 1 carbon steel was used to construct the AN tanks on the HNR and was utilized for this testing. The planned testing of three solutions included a simulant for feasibility and a waste solution from Tank 241-AN-102 (AN-102), taken in 2013, which was run in duplicate. The solutions were evaluated for corrosion potential using cyclic potentiodynamic polarization (CPP) scans to determine the propensity for stress corrosion cracking and pitting corrosion. Results in all solutions showed that pitting potential was low when the pH was above 11 and temperatures were below 40 deg. C. As solution pHs dipped into the 10- 10.5 range, there were mixed results. CPP scans were initially run at the higher temperature of 50 deg. C, accelerating corrosion rates. Solution pHs that did not indicate corrosion were further exposed to CO{sub 2}. Solutions with mixed or positive pitting results were rerun at 40 deg. C. The first failed run on the tank solution was seen when testing the duplicate sample at 50 deg. C and a pH of 13.01. When this solution was retested at 40 deg. C, the CPP scan did not show corrosion. A mixed corrosion result was obtained from a scan run at the final pH of 10 when tested at 50 deg. C. Upon completion of testing a visual inspection of the coupon did not show corrosion products on its surface. These results provide assurance that tanks containing slightly reduced pHs are still protected from pitting corrosion. Tank integrity assurance at a lower pH limit in Tank AN-102 could slow sodium addition and the rising volume of hazardous waste. Other benefits of reducing the pH specification would be reduced costs associated with retrieving and storing smaller volumes of hazardous waste, a reduced number of radiation exposure events (required for pH modification of tank waste), and a potential for a decreased volume required to be immobilized for long-term storage in a vitrified (glass) phase. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chloride-Induced Stress Corrosion Cracking Characteristics of the Used Nuclear Fuel Canister Material

The used nuclear fuel (UNF) dry storage systems are located in the coastal and lake/river-side regions, the service time of which is 60 years and more. One type of dry storage systems is composite of a thin-walled austenitic stainless steel (SS) welded canister and a concrete overpack. The air flows through the canister surface and brings away the decay heat. Meanwhile, the air brings the salt species into the canister and make them deposit on the surface. The salt deposit will be deliquescent when absorbing the moisture air, being corrosive to the surface. NRC and other programs claimed that chloride induced stress corrosion cracking (CISCC) would lead to the canister failure, being one of the major technical gaps for extended dry storage systems. CISCC is induced by the combined influence of the aggressive environment (chloride ions in our case) and tensile stresses (residual stresses in our case) on the susceptible materials (the austenitic SS in our case). Chrome (Cr), as one of the chemical compositions of SSs, plays an important role in the corrosion resistance. It can form a chrome-rich inner barrier oxide layer to prevent the SS from corrosion. However, chloride ions can easily break down the barrier and accelerate dissolution of the underlying metal, the phenomena of which is pitting corrosion. Pitting is the precursor to CISCC as which provides the combination of a local aggressive solution chemistry and a stress concentrating feature. Accordingly, CISCC invariably originates from the pits, and cracks that have nucleated on pit walls can grow around the pit and coalesce to form a complete through-crack. Significant tensile residual stresses, caused by the welding process, exist throughout the thickness of the canister wall. Enos and Bryan found that large residual stresses were in the full-scale mockup container simulating a canister, which supports the SCC propagation. It is therefore interesting to achieve a good knowledge about the effect of welding on the durability of SSs, especially in the corrosive environment. In order to understand the fundamental of the cracking behaviors, it's vital to elucidate the microstructure and microchemistry of cracking. This study focused on observing the CISCC characteristics of the UNF canister material exposed to the humid environment with salt deposit. Extensive micro-characteristics have been achieved by the techniques include focused ion beam/ scanning electron microscope (FIB/SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and optical profiler. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MECHANISTIC UNDERSTANDING OF CAUSTIC CRACKING OF CARBON STEELS

Liquid waste generated by the PUREX process for separation of nuclear materials is concentrated and stored in Type IV single-shell carbon steel tanks at the Savannah River Site (SRS). The Type IV tanks for this waste do not have cooling coils and have not undergone heat treatment to stress-relieve the tanks. After the waste is concentrated by evaporation, it becomes very alkaline and can cause stress corrosion cracking (SCC) and pitting corrosion of the tank materials. SRS has experienced leakage from non-stress-relieved waste tanks constructed of A285 carbon steel and pitting of A212 carbon steel tanks in the vapor space. An investigation of tank materials has been undertaken at SRS to develop a basic understanding of caustic SCC of A285 and A212 grade carbon steels exposed to aqueous solutions, primarily containing sodium hydroxide (NaOH), sodium nitrate (NaNO{sub 3}), and sodium nitrite (NaNO{sub 2}) at temperatures relevant to the operating conditions of both the F and H area plants. This report presents the results of this corrosion testing program. Electrochemical tests were designed using unstressed coupons in a simulated tank environment. The purpose of this testing was to determine the corrosion susceptibility of the tank materials as a function of chemical concentration, pH, and temperature. A285 and A516 (simulates A212 carbon steel) coupons were used to investigate differences in the corrosion of these carbon steels. Electrochemical testing included measurement of the corrosion potential and polarization resistance as well as cyclic potentiodynamic polarization (CPP) testing of coupons. From the CPP experiments, corrosion characteristics were determined including: corrosion potential (E{sub corr}), pitting or breakdown potential (E{sub pit}), and repassivation potential (E{sub prot}). CPP results showed no indications of localized corrosion, such as pitting, and all samples showed the formation of a stable passive layer as evidenced by the positive hysteresis during the scan. Analysis of the CPP data was performed to compare the corrosion susceptibility of the samples under different environmental conditions. Test results indicated that the most important factors affecting corrosion of the steel are the solution temperature, hydroxide concentration, and the material used in constructing the tanks. Variables that did not significantly affect the corrosion susceptibility of the steel were the nitrate or nitrite concentration and the atmosphere in the tank. The passivation current of the coupons increased exponentially with temperature. Longer-term studies of the passivation current are suggested based on results from the literature for iron in highly caustic environments. Polarization resistance studies showed a significant increase in corrosion rate at 125 C and 12 M hydroxide concentration when compared with tests at lower temperatures and lower hydroxide concentrations. Within the temperature and pH range of these tests, iron oxide, Fe{sub 3}O{sub 4}, becomes unstable and could account for the increased corrosion susceptibility. The applicability of these conditions should be confirmed and detailed surface studies should be conducted to determine the corrosion resistance of A285 and A516 carbon steels under these conditions. Surface science studies should also be conducted to determine the role of the carbon steel composition in preventing corrosion under these conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving Abundance Estimates of Spring–Summer Snake River Chinook Salmon for Fisheries Management

Abstract The Columbia River basin is home to a run of spring–summer Chinook Salmon Oncorhynchus tshawytscha that returns to the Snake River drainage of Idaho, Oregon, and Washington in the Pacific Northwest. Historically, the run was one of the more productive throughout the Columbia River basin. However, Snake River spring–summer Chinook Salmon have experienced declines in abundance due to overfishing, habitat degradation, and dams. Several stocks are listed as threatened under the U.S. Endangered Species Act and are supported by mitigation hatcheries funded by Idaho Power Company, the Lower Snake River Compensation Plan, and the Bonneville Power Administration. To maximize tribal and state harvest of returning hatchery adults, minimize impacts on wild fish, and ensure that enough hatchery fish return to meet broodstock needs, careful fisheries management is required. Since 2008, managers have used hatchery adults, PIT-tagged as juveniles and detected at Lower Granite Dam, to generate adult abundance estimates. In season, these estimates inform state and tribal harvest shares and ensure that broodstock needs are met. Postseason, they provide smolt-to-adult survival and return rates. Since 2012, parentage-based tagging (PBT) has provided an alternative method to estimate stock- and age-specific returns at Lower Granite Dam, since returning hatchery adults sampled at Lower Granite Dam can be assigned to their parents. We compared stock-specific abundance estimates between PIT- and PBT-derived methodologies for return years 2016–2019. Across all years, PIT tag estimates accounted for 65% of the PBT-based estimates at Lower Granite Dam across all age-groups and release sites combined. This underrepresentation across all groups equated to 49,833 fish that were not accounted for in PIT tag abundance estimates. It is clear that PBT-based estimates should aide in-season harvest management and postseason run reconstruction to avoid the known bias of estimates from PIT tags, especially during years of low returns when increased accuracy is critical.

Coykendall, D. Katharine (ORCID:0000000211482397)↗

Mechanical and Corrosion Properties of Additively Manufactured CoCrFeMnNi High Entropy Alloy

Here, this study investigates the mechanical and corrosion properties of as-built and annealed equiatomic CoCrFeMnNi alloy produced by laser-based directed energy deposition (DED) Additive Manufacturing (AM). The high cooling rates of DED produced a single-phase, cellular microstructure with cells on the order of 4 μm in diameter and inter-cellular regions that were enriched in Mn and Ni. Annealing created a chemically homogeneous recrystallized microstructure with a high density of annealing twins. The average yield strength of the as-built condition was 424 MPa and exceeded the annealed condition (232 MPa), however; the strain hardening rate was lower for the as-built material stemming from higher dislocation density associated with DED parts and the fine cell size. In general, the yield strength, ultimate tensile strength, and elongation-to-failure for the as-built material exceeded values from previous studies that explored other AM techniques to produce the CoCrFeMnNi alloy. Ductile fracture occurred for all specimens with dimple initiation associated with nanoscale oxide inclusions. The breakdown potential (onset of pitting corrosion) was similar for the as-built and annealed conditions at 0.40 V Ag/AgCl when immersed in 0.6 M NaCl. Pit morphology/propagation for the as-built condition exhibited preferential corrosion of inter-cellular Ni/Mn regions leading to a tortuous pit bottom and cover, while the annealed conditions pits resembled lacy pits similar to 304 L steel. Lastly, a passive oxide film depleted in Cr cations with substantial incorporation of Mn cations is proposed as the primary mechanism for local corrosion susceptibility of the CoCrFeMnNi alloy.

36 MATERIALS SCIENCE↗

Modeling of Diffusivity for 2D Vacancy Nanopits and Comparison with 2D Adatom Nanoislands on Metal(100) Surfaces Including Analysis for Ag(100)

Diffusion coefficients, D N , for 2D vacancy nanopits are compared with those for 2D homoepitaxial adatom nanoislands on metal(100) surfaces, focusing on the variation of DN with size, N. Here, N is measured in missing atoms for pits and adatoms for islands. Analysis of D N is based on kinetic Monte Carlo simulations of a tailored stochastic lattice-gas model, where pit and island diffusion are mediated by periphery diffusion, i.e., by edge atom hopping. Precise determination of D N versus N for typical parameters reveals a cyclical variation with an overall decrease in magnitude for increasing moderate O(10 2 ) ≤ N ≤ O(10 3 ). Monotonic decay, D N ~ N -β , is found for N ≥ O(10 2 ) with effective exponents, β = β eff , for both pits and islands, both well below the macroscopic value of βmacro = 3/2. D N values for vacancy pits are significantly lower (higher) than for adatom islands for moderate N in the case of low (high) kink rounding barrier. However, D N values for pits and islands slowly merge, and β eff → 3/2 for sufficiently large N. The latter feature is expected from continuum Langevin formulations appropriate for large sizes. Finally, we compare predictions from our model incorporating appropriate energetic parameters for Ag(100) with different sets of experimental data for diffusivity at 300 K, including assessment of β eff , for experimentally observed sizes N from ~100 to ~1000.

36 MATERIALS SCIENCE↗

Inverse Stranski-Krastanov growth in InGaAs/InP

Thin films of In{sub x}Ga{sub 1-x}As are observed to develop either islands or pits on the surface to relieve lattice mismatch strain after some critical thickness depending on the composition of the film. The composition is thought to alter either the surface energy or the equilibrium adatom concentration of the growing film, thus changing which strain relieving features, islands, or pits nucleate on the surface first. Once pits form, their behavior is similar to that of islanding, resulting in an ''inverse'' Stranski-Krastanov growth mode. Furthermore, the atomic surface structure near the pits is different than away from the pits and is correlated with island formation.

36 MATERIALS SCIENCE↗

A subdermal tagging technique for juvenile sturgeon using a new self-powered acoustic tag

Abstract Background A new technology for a self-powered acoustic tag (SPT) was developed for active tracking of juvenile fish, intended to avoid the typical battery life constraints associated with active telemetry technology. We performed a laboratory study to evaluate a subdermal tagging technique for the SPT and effects of the tag on survival, tag retention, and growth in juvenile white sturgeon ( Acipenser transmontanus ). Results Survival was associated with tag retention. White sturgeon implanted with the SPT ( n = 30) had 93% survival and tag retention by day 28, 67% by day 101, and 38% by day 595 post-tagging. Sturgeon implanted with a passive integrated transponder (PIT) tag only (control group) had 96% survival and tag retention by day 28, and through day 101 post-tagging. Fish in the PIT group were repurposed after day 101, so no comparisons with this group were made at day 595 post-tagging. Specific growth rate (SGR) for fork length was a median of 0.25% day −1 by day 28 for the SPT group, which was significantly lower than the PIT group (median: 0.42% day −1 ; n = 27). The SPT and PIT groups had similar SGR fork length by day 101 post-tagging (0.22 and 0.25% day −1 , respectively). SGR weight was also lower for the SPT group compared to the PIT group on day 28 (1.39 and 2.11% day −1 , respectively), but the difference again dissipated by day 101 (0.79 and 0.88% day −1 , respectively). Conclusion The tagging technique and placement of the SPT allowed the tag to remain upright along the flank of the sturgeon to ensure maximum battery output of the SPT; however, retention rates of the SPT were not ideal. We provided suggestions to improve the tagging technique. Suggestions included tagging fish that are > 400 mm FL, moving the incision location to extend the cavity and create a pocket for the placement of the SPT, and performing a quantitative wound-healing evaluation. Future studies are therefore recommended to evaluate these suggestions.

59 BASIC BIOLOGICAL SCIENCES↗

Corrective Action Decision Document/Closure Report for Corrective Action Unit 367: Area 10 Sedan, Ess and Uncle Unit Craters Nevada National Security Site, Nevada, Revision 0 with ROTC 1

Corrective Action Unit 367 comprises four corrective action sites (CASs): • 10-09-03, Mud Pit • 10-45-01, U-10h Crater (Sedan) • 10-45-02, Ess Crater Site • 10-45-03, Uncle Crater Site The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation of the corrective actions and site closure activities implemented at CAU 367. A corrective action of closure in place with use restrictions was completed at each of the three crater CASs (10-45-01, 10-45-02, and 10-45-03); corrective actions were not required at CAS 10-09-03. In addition, a limited soil removal corrective action was conducted at the location of a potential source material release. Based on completion of these correction actions, no additional corrective action is required at CAU 367, and site closure is considered complete. Corrective action investigation (CAI) activities were performed from February 2010 through March 2011, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 367: Area 10 Sedan, Ess and Uncle Unit Craters, Nevada Test Site, Nevada. The approach for the CAI was divided into two facets: investigation of the primary release of radionuclides, and investigation of non-test or other releases (e.g., migration in washes and potential source material). Based on the proximity of the Uncle, Ess, and Sedan craters, the impact of the Sedan test on the fallout deposited from the two earlier tests, and aerial radiological surveys, the CAU 367 investigation was designed to study the releases from the three crater CASs as one combined release (primary release). Corrective Action Site 10-09-03, Mud Pit, consists of two mud pits identified at CAU 367. The mud pits are considered non-test releases or other releases and were investigated independent of the three crater CASs. The purpose of the CAI was to fulfill data needs as defined during the data quality objective (DQO) process. The CAU 367 dataset of investigation results was evaluated based on a data quality assessment. This assessment demonstrated the dataset is complete and acceptable for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels (FALs) established in this document. For the primary release, radiological doses exceeding the FAL of 25 millirem per year were not found to be present in the surface or shallow subsurface soil outside the default contamination boundary. However, it was assumed that radionuclides are present in subsurface media within each of the three craters (Sedan, Ess, and Uncle) due to prompt injection of radionuclides from the tests. Based on the assumption of radiological dose exceeding the FAL, corrective actions were undertaken that consisted of implementing a use restriction and posting warning signs at each crater CAS. These use restrictions were recorded in the FFACO database; the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Facility Information Management System; and the NNSA/NSO CAU/CAS files. With regard to other releases, no contaminants of concern were identified at the mud pits or any of the other release locations, with one exception. Potential source material in the form of lead was found at one location. A corrective action of clean closure was implemented at this location, and verification samples indicated that no further action is necessary. Therefore, NNSA/NSO provides the following recommendations: • A Notice of Completion to NNSA/NSO is requested from the Nevada Division of Environmental Protection for closure of CAU 367. • Corrective Action Unit 367 should be promoted from Appendix III to Appendix IV of the FFACO.

54 ENVIRONMENTAL SCIENCES↗

Characteristics of KE Basin Sludge Samples Archived in the RPL - 2007

Samples of sludge were collected from the K East fuel storage basin (KE Basin) floor, contiguous pits (Weasel Pit, North Load Out Pit, Dummy Elevator Pit, and Tech View Pit), and fuel storage canisters between 1995 and 2003 for chemical and radionuclide concentration analysis, physical property determination, and chemical process testing work. Because of the value of the sludge in this testing and because of the cost of obtaining additional fresh samples, an ongoing program of sludge preservation has taken place with the goals to track the sludge identities and preserve, as well as possible, the sludge composition by keeping the sludge in sealed jars and maintaining water coverage on the sludge consistent with the controlling Fluor Hanford (FH) Sampling and Analysis plans and FH contracts with the Pacific Northwest National Laboratory (PNNL). This work was originally initiated to provide material for planned hydrothermal treatment testing in accordance with the test plan for the Sludge Treatment Project (STP) corrosion process chemistry follow on testing (Delegard et al. 2007). Although most of the planned hydrothermal testing was canceled in July 2007 (as described in the forward of Delegard et al. 2007), sample consolidation and characterization was continued to identify a set of well-characterized sludge samples that are suited to support evolving STP initiatives. The work described in the letter was performed by the PNNL under the direction of the Sludge Treatment Project, managed by Fluor Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3013 DE Inner Container Closure Weld Corrosion Evaluation

Destructive evaluation (DE) of 3013 containers is one part of the U. S. Department of Energy Integrated Surveillance Program. During standard DE of 3013 containers, visual examinations for pitting and stress corrosion cracking (SCC) are performed on the accessible surfaces of the outer, inner, and convenience containers, which make up the 3013 container. As a result of 3013 DE additional analysis, the area near the inner container closure weld has been identified as being a region of increased corrosion susceptibility, which may provide a pathway for corrosive gases to the outer container. This area has a higher residual stress, an altered microstructure, and less corrosion resistant weld oxides as a result of the welding process as well as a lower temperature than other areas of the container, which may increase the absorption of moisture on the surface. The deposition of moisture in this stressed region could lead to pitting and stress corrosion cracking. During FY2013, the inner container closure weld area was more closely evaluated on several archived samples from DE containers. These containers included FY09 DE2, FY12 DE4, FY12 DE6 and FY12 DE7 and the Hanford High Moisture Container. The additional examinations included visual observations with a stereomicroscope, scanning electron microscopy along with energy dispersive spectroscopy for chemical analysis, and serial metallography of the sidewall and lid that are part of the inner container closure weld region. Pitting was observed in all the samples taken from the closure weld regions of the examined inner containers. This pitting was generally less 20 µm with most less than 5µm. These pits were similar in depth to those observed in the vapor exposed surfaces of teardrops in the shelf life corrosion testing. Cracking was not observed on either the vapor-exposed surfaces of the teardrop coupons or the inner container closure weld region. Further testing is necessary to determine if the conditions in the welded inner container could support SCC during the 50 year life time for the 3013 container.

36 MATERIALS SCIENCE↗

Uncertainty quantification methodologies development for stress corrosion cracking of canister welds

This letter report presents a probabilistic performance assessment model to evaluate the probability of canister failure (through-wall penetration) by SCC. The model first assesses whether environmental conditions for SCC – the presence of an aqueous film – are present at canister weld locations (where tensile stresses are likely to occur) on the canister surface. Geometry-specific storage system thermal models and weather data sets representative of U.S. spent nuclear fuel (SNF) storage sites are implemented to evaluate location-specific canister surface temperature and relative humidity (RH). As the canister cools and aqueous conditions become possible, the occurrence of corrosion is evaluated. Corrosion is modeled as a two-step process: first, pitting is initiated, and the extent and depth of pitting is a function of the chloride surface load and the environmental conditions (temperature and RH). Second, as corrosion penetration increases, the pit eventually transitions to a SCC crack, with crack initiation becoming more likely with increasing pit depth. Once pits convert to cracks, a crack growth model is implemented. The SCC growth model includes rate dependencies on both temperature and crack tip stress intensity factor, and crack growth only occurs in time steps when aqueous conditions are predicted. The model suggests that SCC is likely to occur over potential SNF interim storage intervals; however, this result is based on many modeling assumptions. Sensitivity analyses provide information on the model assumptions and parameter values that have the greatest impact on predicted storage canister performance, and provide guidance for further research to reduce uncertainties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2019)

During fiscal year (FY) 2019, the Savannah River National Laboratory (SRNL) focused on four primary tasks for Hanford Double Shell Tanks (DSTs) corrosion studies. The first task, New Limits, was a continuation from the electrochemical work started in FY16, to expand electrochemical testing to elevated temperatures and elevated hydroxide concentrations and evaluate how these factors will influence pitting corrosion. Using the pitting factor (PF) equation, these new conditions were validated to provide a conservative estimate for the susceptibility of pitting corrosion on legacy carbon steel. The second task, Secondary Liner Corrosion, focused on Vapor Space Corrosion (VSC) and immersion testing studies using two commercially available vapor corrosion inhibitors (VCIs). For this FY, the VCI strategy was applied mid-experiment to determine performance on weathered coupons. The third task, Long-Term Open Circuit Potential (OCP) Drift, was performed using simplified simulated chemistries to evaluate change in pitting corrosion risk due to evolution of corrosion potential for mill-scale and freshly polished 600-grit surfaces. Finally, the fourth task, Microbiologically-Influenced Corrosion (MIC) studies, was focused on the study of leak detection pit (LDP) water sent from the Hanford tank farm for determination of bacteria that can be conducive to corrosion using commercially available kits: BART TM and MICkit® 5. In addition, this FY, a secondary task was added which was a continuation of the study of the Quartz-enhanced Photoacoustic Spectroscopy (QEPAS) system. Work was started but was ultimately not pursued. A summary of each task performed is presented below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pulsed Infrared Thermography Nondestructive Imaging of SiC-SiC f Composite Cladding Architectures; Understanding the Performance of SiC-SiC f Composite Cladding Architectures with Cr Coating in Normal Operating and Accident Conditions in LWRs and Advanced Reactors

SiC-SiC f composites, consisting of silicon carbide fibers embedded in a silicon carbide matrix, are advanced materials with high thermal conductivity, temperature stability, and resistance to radiation damage. Traditional methods for quality control of fabricated SiC-SiC f composites involve nondestructive evaluation (NDE) with X-ray computed tomography (XCT). However, XCT imaging of typical SiC-SiC f structures for cladding applications can involve several hours. In this project, we investigate an alternative approach to NDE of SiC-SiC f composites that involves rapid (on the order of seconds) imaging with Pulsed infrared thermography (PIT). PIT images of a planar SiC-SiC f specimen show the structure of the surface monolith layer and internal SiC f structures. The capability of PIT imaging in visualizing SiC f structures is qualitatively confirmed by observing similarity in the PIT and X-ray transmission images of the same specimen. Computer vision analysis of defects in the PIT image of the monolith was performed with thresholding followed by topological structural analysis that computed geometric descriptors, including major/minor axes of fitted ellipses, area, perimeter, Feret diameter, circularity, roundness, and solidity.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Research, Monitoring, and Evaluation of Avian Predation on Salmonid Smolts in the Lower and Mid-Columbia River, 2008 Draft Season Summary.

This report describes investigations into predation by piscivorous colonial waterbirds on juvenile salmonids (Oncorhynchus spp.) from throughout the Columbia River basin during 2008. East Sand Island in the Columbia River estuary again supported the largest known breeding colony of Caspian terns (Hydroprogne caspia) in the world (approximately 10,700 breeding pairs) and the largest breeding colony of double-crested cormorants (Phalacrocorax auritus) in western North America (approximately 10,950 breeding pairs). The Caspian tern colony increased from 2007, but not significantly so, while the double-crested cormorant colony experienced a significant decline (20%) from 2007. Average cormorant nesting success in 2008, however, was down only slightly from 2007, suggesting that food supply during the 2008 nesting season was not the principal cause of the decline in cormorant colony size. Total consumption of juvenile salmonids by East Sand Island Caspian terns in 2008 was approximately 6.7 million smolts (95% c.i. = 5.8-7.5 million). Caspian terns nesting on East Sand Island continued to rely primarily on marine forage fishes as a food supply. Based on smolt PIT tag recoveries on the East Sand Island Caspian tern colony, predation rates were highest on steelhead in 2008; minimum predation rates on steelhead smolts detected passing Bonneville Dam averaged 8.3% for wild smolts and 10.7% for hatchery-raised smolts. In 2007, total smolt consumption by East Sand Island double-crested cormorants was about 9.2 million juvenile salmonids (95% c.i. = 4.4-14.0 million), similar to or greater than that of East Sand Island Caspian terns during that year (5.5 million juvenile salmonids; 95% c.i. = 4.8-6.2 million). The numbers of smolt PIT tags recovered on the cormorant colony in 2008 were roughly proportional to the relative availability of PIT-tagged salmonids released in the Basin, suggesting that cormorant predation on salmonid smolts in the estuary was less selective than tern predation. Cormorant predation rates in excess of 30%, however, were observed for some groups of hatchery-reared fall Chinook salmon released downstream of Bonneville Dam. Implementation of the federal plan 'Caspian Tern Management to Reduce Predation of Juvenile Salmonids in the Columbia River Estuary' was initiated in 2008 with construction by the Corps of Engineers of two alternative colony sites for Caspian terns in interior Oregon: a 1-acre island on Crump Lake in the Warner Valley and a 1-acre island on Fern Ridge Reservoir near Eugene. We deployed Caspian tern social attraction (decoys and sound systems) on these two islands and monitored for Caspian tern nesting. Caspian terns quickly colonized the Crump Lake tern island; about 430 pairs nested there, including 5 terns that had been banded at the East Sand Island colony in the Columbia River estuary, over 500 km to the northwest. No Caspian terns nested at the Fern Ridge tern island in 2008, but up to 9 Caspian terns were recorded roosting on the island after the nesting season. There were two breeding colonies of Caspian terns on the mid-Columbia River in 2008: (1) about 388 pairs nested at the historical colony on Crescent Island in the McNary Pool and (2) about 100 pairs nested at a relatively new colony site on Rock Island in the John Day Pool. Nesting success at the Crescent Island tern colony was only 0.28 young fledged per breeding pair, the lowest nesting success recorded at that colony since monitoring began in 2000, while only three fledglings were raised at the Rock Island tern colony. The diet of Crescent Island Caspian terns consisted of 68% salmonid smolts; total smolt consumption was estimated at 330,000. Since 2004, total smolt consumption by Crescent Island terns has declined by 34%, due mostly to a decline in colony size, while steelhead consumption has increased 10% during this same period. In 2008, approximately 64,000 steelhead smolts were consumed by Caspian terns nesting at Crescent Island. Based on smolt PIT tag recoveries on the Crescent Island Caspian tern colony, the average predation rate on in-river migrants from the Snake River (all species and run types combined based on interrogations at Lower Monumental Dam) was at least 1.4%. Predation rates on PIT-tagged steelhead smolts were greater than those for other salmonid species; 6.0% of wild steelhead smolts from the Snake River were consumed by Crescent Island terns. The double-crested cormorant colony on Foundation Island in the mid-Columbia River consisted of at least 360 pairs nesting in trees in 2008. The proportion of juvenile salmonids in stomach samples collected from cormorants nesting on Foundation Island during the peak of the smolt out-migration was about 45% of prey biomass.