Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

En route position and time control of aircraft using Kalman filtering of radio aid data

Fixed-time-of-arrival (FTA) guidance and navigation is investigated as a possible technique capable of operation within much more stringent en route separation standards and offering significant advantages in safety, higher traffic densities, and improved scheduling reliability, both en route and in the terminal areas. This study investigated the application of FTA guidance previously used in spacecraft guidance. These FTA guidance techniques have been modified and are employed to compute the velocity corrections necessary to return an aircraft to a specified great-circle reference path in order to exercise en route time and position control throughout the entire flight. The necessary position and velocity estimates to accomplish this task are provided by Kalman filtering of data from Loran-C, VORTAC/TACAN, Doppler radar, radio or barometric altitude,and altitude rate. The guidance and navigation system was evaluated using a digital simulation of the cruise phase of supersonic and subsonic flights between San Francisco and New York City, and between New York City and London.

Mcgee, L. A.↗

An experimental evaluation of metallic diaphragms for positive fuel expulsion in the atmosphere explorer hydrazine propulsion subsystem

Four Arde conospheroid metallic diaphragms were tested to evaluate their capability for use in the orbit adjust propulsion subsystem (OAPS) of the Explorer spacecraft. The diaphragms will be used for positive propellant expulsion and spacecraft center of mass control. A leak-free cycle life capability of nine reversals was demonstrated. The diaphragms rolled smoothly from ring to ring in a predictable manner on the first reversal. Varying amounts of diaphragm cocking and ring skipping were observed on subsequent reversals. The diaphragm pressure differential did not exceed 7 N/sq cm during any reversal. Cycle life capability, reversal mode, and pressure differential were not affected by sudden reversals, environmental tests, or 18,000 partial reversals. An expulsion efficiency of approximately 97 percent was demonstrated. The results of these tests show that metallic diaphragms can be used as an effective means of positive fuel expulsion; however, to achieve spacecraft center of mass control, the diaphragm must not be reversed prior to flight.

Woodruff, W. L.↗

A high resolution study in time, position, intensity, and frequency of a radio event on 14 January 1971

High resolution position and spectrum measurements were made of a complex solar radio activity on January 14, 1971, from 1120 to 1130 UT. Positions were measured with 169 MHz Nancay E-W Radioheliograph, while dynamic spectra and polarization were observed with the 60-channel radiospectrograph of Nera. The radio event consisted of two closely similar groups of type 3 bursts and type 2-like details, and a stationary type 4 continuum, including some very clear pulsating structures. The general aspect of this activity is presented.

Caroubalos, C.↗

Two-position dc pulse voltage stabilizer

The advantages of the dc pulse voltage stabilizers over the continuous action stabilizers are described. These advantages include higher efficiency, low sensitivity to the ambient temperature and insignificant size and weight. A comparison is made between the schematics of the known two position pulse stabilizer with a Schmitt trigger and that developed by the author. A characteristic feature of the improved system is the increased stabilization coefficient and the possibility of smooth regulation of the output voltage. A practical schematic is presented for the improved two position pulse stabilizer along with its parameters.

Osadchiy, V. I.↗

Effects of an anti-G suit on the hemodynamic and renal responses to positive /+Gz/ acceleration

The effects of the currently used U.S. Air Force (CSU-12/P) anti-G suit on renal function during positive radial acceleration (+Gz) were assessed in seven normal male subjects in balance on a 200 meq sodium diet. Following suit inflation in the seated position, +2.0 Gz for 30 min resulted in a decrease in the rate of sodium excretion from 125 plus or minus 19 to 60 plus or minus 14 microeq/min, which persisted during a 25-min recovery period. Fractional excretion of sodium also decreased significantly during +Gz. The magnitude of the antinatriuresis was indistinguishable from that observed during +Gz without suit inflation. In contrast to the antinatriuresis observed during centrifugation without suit, however, the antinatriuresis with suit was mediated primarily by an enhanced tubular reabsorption of sodium.

Shubrooks, S. J., Jr.↗

Temporal variations in the dawn and dusk midlatitude trough and plasmapause position

The temporal development of the latitudinal position of a 600-km midlatitude electron density trough at dawn and dusk during the period 25-27 May 1967, which encompassed a large magnetic storm, was measured by the RF capacitive probe on the polar orbiting Ariel 3 satellite. The substorm-related changes in the L coordinate of the trough minimum and the point of most rapid change of density gradient on the low latitude side of the trough are similar. Oscillations of the trough position at dusk are in phase with substorm activity whereas movement of the trough at dawn is only apparent with the onset of the large storm. Detailed model calculations of the plasmasphere dynamics assuming a spatially invariant equatorial convection E-field which varies in step with the K sub p index produces a plasmapause motion which parallels the observed trough behaviour.

Grebowsky, J. M.↗

Positive isolation disconnect

A positive isolation disconnect was developed for component replacement in serviced liquid and gaseous spacecraft systems. Initially a survey of feasible concepts was made to determine the optimum method for fluid isolation, sealing techniques, coupling concepts, and foolproofing techniques. The top concepts were then further evaluated, including the fabrication of a semifunctional model. After all tradeoff analyses were made, a final configuration was designed and fabricated for development testing. This resulted in a 6.35 mm (1/4 inch) line and 12.7 mm (1/2 inch) line positive isolation disconnect, each unit consisting of two coupled disconnect halves, each capable of fluid isolation with essentially zero clearance between them for zero leakage upon disconnect half disengagement. An interlocking foolproofing technique was incorporated that prevents uncoupling of disconnect halves prior to fluid isolation.

Rosener, A. A.↗

Characteristics of the NASA Lewis bumpy-torus plasma generated with positive applied potentials

Experimental observations were made during steady-state operation of a bumpy-torus plasma at input powers up to 150 kW in deuterium and helium gas and with positive potentials applied to the midplane electrodes. In this steady-state ion heating method a modified Penning discharge is operated such that the plasma is acted upon by a combination of strong electric and magnetic fields. Experimental investigation of a deuterium plasma revealed electron temperatures from 14 to 140 eV and ion kinetic temperatures from 160 to 1785 eV. At least two distinct modes of operation exist. Experimental data shows that the average ion residence time in the plasma is virtually independent of the magnetic field strength. Data was taken when all 12 anode rings were at high voltage, and in other symmetric configurations in which the toroidal plasma was generated by applying positive potentials to six anode rings, three anode rings, and a single anode ring.

Roth, J. R.↗

Flight representative positive isolation disconnect

Resolutions were developed for each problem encountered and a tradeoff analysis was performed to select a final configuration for a flight representative PID (Positive Isolation Disconnect) that is reduced in size and comparable in weight and pressure drop to the developmental PID. A 6.35 mm (1/4-inch) line size PID was fabricated and tested. The flight representative PID consists of two coupled disconnect halves, each capable of fluid isolation with essentially zero clearance between them for zero leakage upon disconnect half disengagement. An interlocking foolproofing technique prevents uncoupling of disconnect halves prior to fluid isolation. Future development efforts for the Space Shuttle subsystems that would benefit from the use of the positive isolation disconnect are also recommended. Customary units were utilized for principal measurements and calculations with conversion factors being inserted in equations to convert the results to the international system of units.

Rosener, A. A.↗

The development of a positive isolation disconnect

Conceptual design and developmental testing were conducted to determine the feasibility of a highly reliable, positive isolation disconnect (PID) for potential inflight maintenance of Shuttle environmental control/life support system subsystems. The PID design consists of two coupled valves, each capable of fluid isolation through the use of individually operated opposing poppets. An integral level clamping mechanism couples the two valves and locks the bodies together. The coupling lever is locked in position by turning the valve stems that have foolproof caps. The stem shaft has an integral cam that turns inside a yoke to open the poppet to permit fluid flow. Results of 5000 life cycle tests, hydraulic lock test, leakage tests, and pressure drop tests are included.

Rosener, A. A.↗

Positions of galactic X-ray sources - Galactic longitude between 20 and 55 deg

Precise positions, determined with data from the SAS-3 X-ray observatory, are presented for eight galactic plane X-ray sources (Aql X-1, Ser X-1, 3U 1956+11, 3U 1822-00, 3U 1915-05, A 1845-02, A 1850-08, A 1905+00). Error radii for the positions range from 20 to 50 arc s. Previously proposed optical identifications of three of the sources (Ser X-1, 3U 1956+11, A 1850-08) are supported by these results. Three (Ser X-1, A 1905+00, 3U 1915-05) have been identified as X-ray burst sources.

Doxsey, R. E.↗

Single pass Doppler positioning for Search and Rescue satellite missions

This paper describes the implementation of beacon location experiments involving the NASA Nimbus-6 and the Amateur Satellite Corporation (AMSAT) Oscar-6 and Oscar-7 spacecraft. The purpose of these experiments is to demonstrate the feasibility of determining the geographical location of a low power VHF 'distress beacon' via satellite. Doppler data collected during satellite passes is reduced in a mini-computer by means of a simple algorithm resulting in the simultaneous recovery of the unknown receiver coordinates and the unknown Doppler bias frequency. Results indicate point positioning to within a few kilometers - which is within the required accuracies for the positioning of downed aircraft for Search/Rescue missions.

Schmid, P. E.↗

Noncontacting valve-position indicator

Position of sealed valve or other movable part is indicated without penetrating housing. Flux from magnets connected to stem of hydraulic valve penetrates pressure wall and is sensed by Hall-effect transducer outside wall. When valve closes, moving stem and magnets, voltage from transducer decreases; thus, stem position is indicated without physical contact.

Crovella, E. A.↗

"Blind" position indicator

Position-indicating instrument helps operator align parts without seeing them. Device is useful in industrial operations where parts must be blind-positioned accurately.

Cruzan, R. C.↗

Certain peculiarities of the functioning of the cardiovascular system in bedrest conditions during horizontal and antiorthostatic body positions

The adequate modeling of physiological reactions inherent to the state of weightlessness has become a matter of particular urgency in space medicine. This modeling is necessary for studying the phenomenology and degree of disorders, prognostication of the crew's health, and developing the various preventive measures employed in space flights. A comparison is made of the physiological effects brought about by bed rest in a horizontal and antiorthostatic body position. A study is done of the influence of brief antiorthostatic hypokinesia, simulating the acute period of adaptation to weightlessness, on circulation and on a number of involved analytical systems. The basic model accepted is antiorthostatic hypokinesia with a body position declination angle of 4 deg (head lower than feet). The experiment's duration is dictated by the objectives of the research.

Source record↗

Position and pulse profile of the X-ray transient 4U 0115 + 63

The celestial position of the 3.6-s X-ray pulsar, 4U 0115 + 63, has been measured to a precision of 12 arcsec in one dimension with the scanning modulation collimator experiment on HEAO 1. This result, together with a position obtained with SAS 3, has led to the identification of an early-type star as the optical counterpart. An X-ray luminosity of approximately 3 by 10 to the 37th power erg/s (3-13 keV) is inferred from the observed flux of about 30% that of the Crab and an estimated distance of 5 kpc. The pulse profile over the energy range 3-13 keV is similar to that of Cen X-3.

Johnston, M.↗

Positive isolation disconnect

A disconnect composed basically of two halves each consisting of a poppet valve operable to isolate fluid with essentially zero fluid loss is presented. The two halves are coupled together by a quickly releasable coupling which may be either a coupling ring tightened or loosened by a twisting motion, or a clamp operated by a pivoted to prevent disconnecting the two halves until both valves are in closed condition. The positive feature of the device is one requiring a valve closing step before a disconnect step, and takes structural form in an accentric lobe mounted on the valve operating stem. If some obstruction prevents the poppet from moving to its seat, the eccentric lobe cannot be rotated to the closed position, and the interlock prevents a disconnect.

Friedell, M. V.↗

Investigations of negative and positive cesium ion species

A direct test is provided of the hypothesis of negative ion creation at the anode or collector of a diode operating under conditions simulating a cesium thermionic converter. The experimental technique involves using direct ion sampling through the collector electrode with mass analysis using a quadrupole mass analyzer. Similar measurements are undertaken on positive ions extracted through the emitter electrode. Measurements were made on a variety of gases including pure cesium, helium-cesium mixtures and cesium-hydrogen as well as cesium-xenon mixtures. The gas additive was used primarily to aid in understanding the negative ion formation processes. Measurements were conducted using emitter (cathode) temperatures up to about 1000 F. The major negative ion identified through the collector was Cs(-) with minor negative ion peaks tentatively identified as H(-), H2(-), H3(-), He(-) and a mass 66. Positive ions detected were believed to be Cs(+), Cs2(+) and Cs3(+).

Chanin, L. M.↗