Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Novel Sensors for Particle Tracking: a Contribution to the Snowmass Community Planning Exercise of 2021

Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon, submicron-dimension pixels, thin film detectors, and scintillating quantum dots in gallium arsenide. Drivers of the technologies include radiation hardness, excellent position, vertex, and timing resolution, simplified integration, and optimized power, cost, and material.

Detectors↗

Microwave holographic imaging of aircraft with spaceborne illuminating source

The conceptual development of a method for the high angular resolution and accurate angular position estimates for the surveillance and traffic control of aircraft is considered. A target volume several hundred kilometers in diameter is illuminated by a CW microwave source located on a satellite in geosynchronous orbit. Signals are received by a large array of random, conformally located receiving elements. Each element receives the direct signal from the satellite plus signals reflected from aircraft in the illuminated volume. Coherent combination of the signals received from the individual elements permits the equivalent of holographic imaging or multiple beam formation from which the useful target data can be obtained.

Berkowitz, R. S.↗

Low-frequency radio navigation for the Army's Mobile Automated Field Instrumentation System /MAFIS/

The Jet Propulsion Laboratory is engaged in the early phases of conceptual, preliminary design, and feasibility demonstration studies leading to determination of a design and implementation of the Army's proposed Mobile Automated Field Instrumentation System (MAFIS). An overview is provided of the current design concept for an experimental radio navigation subsystem to be implemented in the field as a part of the MAFIS study effort. Objectives of MAFIS include mobility, field-ruggedness and longevity of equipment, and low acquisition and life-cycle costs. The navigation subsystem comprises a 4-station radio transmitter network, plus the navigation receivers, network monitoring receivers and communications links, and interface to the command/control 'central' for transmitter status monitoring. Attention is given to accuracy goals, radio propagation effects, transmitter arrangement, radio-frequency allocations, position initialization and lane resolution, and transmitter and receiver functions.

Wallis, D. E.↗

Hot shocked gas along the jets of NGC 4258 (M106)

The ROSAT High Resolution Interferometer (HRI) and Position Sensitive Proportional Counter (PSPC) detectors have been used to study the soft X-ray emission of the nearby SABbc galaxy NGC 4258 (M106). The helically twisted, nuclear jets, previously detected in radio continuum and visual emission-line studies, are found to dominate the X-ray images. After correcting pointing errors of up to +/- 7 sec in our HRI observation, we find that the southeast jet is spatially unresolved transversely along much of its 2.5 min (5 kpc) length. The northwest jet is more diffuse, and the extensive radio 'plateaus' also emit X-rays. The energy spectrum of the jets from the PSPC exposure is noisy but is best fitted as a Raymond-Smith plasma with kT = 0.3 keV, log N(sub H) approximately = 20.0/sq cm, and luminosity 1.6 x 10(exp 40) ergs/s between 0.1 and 2.4 keV. Gas at this temperature can arise from planar shocks of 500 km/s and may have been entrained as the jets scrape along the molecular clous that are known to be adjacent to the jets. The range of radial velocities from our published visual emission-line spectra of the jet are consistent with such a shock speed. We estimate that the mass of hot gas in the jets is 6 x 10(exp 4) (1/cc/n(sub e)) solar mass, with n(sub e) the average electron density. The inferred pressure of hot gas in the southeast jet may be similar to the radio equipartition pressure and to the ambient pressure of the interstellar medium (ISM). The X-ray spectral fit is poor above 0.7 keV and requires an additional hard component that peaks near the nucleus.

Cecil, G.↗

ROSAT observations of the Jupiter aurora

Roentgen satellite (ROSAT) high-resolution imager (HRI) and position sensitive proportional counter (PSPC) observations of Jupiter obtained in April 1991 and May 1992 reveal soft X-ray emissions apparently associated with Jupiter's aurora and similar to X-ray emssions observed earlier by the Einstein Observatory. The HRI images show emission mainly from Jupiter's northern hemisphere at all Jovian longitudes observed, and there is some indication of a longitudinal modulation of the emission in phase with well-known ultraviolet modulation of the northern aurora. The PSPC data reveal a very soft spectrum. Comparison of the observed spectrum with models for both electron bremsstrahlung radiation and line emission from S and O ions indicates that the line spectrum gives a much better statistical fit to the observed spectrum. The X ray observations presented here therefore support the hypothesis that ion precipitation is the most likely cause of the Jovian X ray emissions, a result first suggested by the Einstein results (Metzger et al., 1983).

Waite, J. H., Jr.↗

FE Features in Highly Obscured AGN

This final report is a summary of the combined study of ASCA (Advanced Satellite for Cosmology and Astrophysics) observations of NGC 7582 with archival ROSAT HRI (High Resolution Imager) and PSPC (Position Sensitive Proportional Counter) data. These observations were important in that they established that X-ray emission in NGC 7582, the most narrow-line of NLXGs (narrow-line X-ray galaxies), is associated with an AGN (Active Galactic Nuclei). Thus implying that all NLXGs are obscured AGN, as has been hypothesized to explain the X-ray spectral background paradox.

Schachter, Jonathan F.↗

Novel Sensors for Particle Tracking: a Contribution to the Snowmass Community Planning Exercise of 2021

Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon, submicron-dimension pixels, thin film detectors, and scintillating quantum dots in gallium arsenide. Drivers of the technologies include radiation hardness, excellent position, vertex, and timing resolution, simplified integration, and optimized power, cost, and material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seven Channel Multi-collector Isotope Ratio Mass Spectrometer

A new magnetic sector mass spectrometer that utilizes seven full-sized discrete dynode electron multipliers operating simultaneously has been designed, constructed and is in preliminary testing. The instrument utilizes a newly developed ion dispersion lens that enables the mass dispersed individual isotope beams to be separated sufficiently (35 mm) to allow a full-sized discrete dynode pulse counting multiplier to be used for each beam. The ion dispersion lens is a two element electrostatic 90 degree sector device that causes the beam-to-beam dispersion to increase faster than the intra-beam dispersion. Each multiplier is contained in an isolated case with a deflector/condenser lens at the entrance. A 9-sample filament cartridge is mounted on a micro-manipulator two-axis stage that enables adjustment of the filament position with 10 micron resolution within the ion lens. Results of initial testing with actinides will be presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regional grid refinement in an Earth system model: impacts on the simulated Greenland surface mass balance

In this study, the resolution dependence of the simulated Greenland ice sheet surface mass balance (GrIS SMB) in the variable-resolution Community Earth System Model (VR-CESM) is investigated. Coupled atmosphere–land simulations are performed on two regionally refined grids over Greenland at 0.5° (~55 km) and 0.25° (~28 km), maintaining a quasi-uniform resolution of 1° (~111 km) over the rest of the globe. On the refined grids, the SMB in the accumulation zone is significantly improved compared to airborne radar and in situ observations, with a general wetting (more snowfall) at the margins and a drying (less snowfall) in the interior GrIS. Total GrIS precipitation decreases with resolution, which is in line with best-available regional climate model results. In the ablation zone, CESM starts developing a positive SMB bias with increased resolution in some basins, notably in the east and the north. The mismatch in ablation is linked to changes in cloud cover in VR-CESM, and a reduced effectiveness of the elevation classes subgrid parametrization in CESM. Overall, our pilot study introduces VR-CESM as a new tool in the cryospheric sciences, which could be used to dynamically downscale SMB in scenario simulations and to force dynamical ice sheet models through the CESM coupling framework.

54 ENVIRONMENTAL SCIENCES↗

Powder diffraction by fixed incident angle reflection using a curved position-sensitive detector

As curved position-sensitive detectors improve in angular resolution, the effects that fixed incident angle reflection have on X-ray diffraction peaks become more apparent. In this study the effects of sample transparency, incident beam height, detector resolution and sample displacement on the intensity, location, width and shape of powder diffraction peaks were examined. The functions describing each of these phenomena are presented and were successfully used to quantitatively model the diffraction peaks collected in this geometry. Three distinct regimes of diffraction peak resolution were identified from the phenomena that limit the peak variance. Pertinent criteria based on experimental parameters have been outlined to classify fixed incident angle reflection experiments into each regime. Guidelines for improvement of experimental resolution and for conducting analysis of data acquired using fixed incident angle reflection geometry and curved position-sensitive detectors are also provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional positioning and structure of chromosomes in a human prophase nucleus

The human genetic material is packaged into 46 chromosomes. The structure of chromosomes is known at the lowest level, where the DNA chain is wrapped around a core of eight histone proteins to form nucleosomes. Around a million of these nucleosomes, each about 11 nm in diameter and 6 nm in thickness, are wrapped up into the complex organelle of the chromosome, whose structure is mostly known at the level of visible light microscopy to form a characteristic cross shape in metaphase. However, the higher-order structure of human chromosomes, between a few tens and hundreds of nanometers, has not been well understood. We show a three-dimensional (3D) image of a human prophase nucleus obtained by serial block-face scanning electron microscopy, with 36 of the complete set of 46 chromosomes captured within it. The acquired image allows us to extract quantitative 3D structural information about the nucleus and the preserved, intact individual chromosomes within it, including their positioning and full spatial morphology at a resolution of around 50 nm in three dimensions. The chromosome positions were found, at least partially, to follow the pattern of chromosome territories previously observed only in interphase. The 3D conformation shows parallel, planar alignment of the chromatids, whose occupied volumes are almost fully accounted for by the DNA and known chromosomal proteins. Here, we also propose a potential new method of identifying human chromosomes in three dimensions, on the basis of the measurements of their 3D morphology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Resolution Emission Spectroscopy of the Alpha Pi-1 - Chi Sigma-1(+) Fourth Positive Band System of CO from Electron Impact

We report electron-impact induced fluorescence spectra [300 mA full width at half maximum (FWHM)] of CO for 20 and 100 eV impact energies of the spectral region of 1300 to 2050 A and high resolution spectra (FWHM) of the v'=5 to v"=l and the v'=3 to v"=O bands showing that the rotational structure of the band system are modeled accurately. The excitation function of the (0,1) band (1597 A) was measured from electron impact in the energy range from threshold to 750 eV and placed on an absolute scale from modem calibration standards.

Beegle, Luther W.↗

Upgrading and testing program for narrow band high resolution planetary IR imaging spectrometer

An imaging spectrometer, intended primarily for observations of the outer planets, which utilizes an acoustically tuned optical filter (ATOF) and a charge coupled device (CCD) television camera was modified to improve spatial resolution and sensitivity. The upgraded instrument was a spatial resolving power of approximately 1 arc second, as defined by an f/7 beam at the CCD position and it has this resolution over the 50 arc second field of view. Less vignetting occurs and sensitivity is four times greater. The spectral resolution of 15 A over the wavelength interval 6500 A - 11,000 A is unchanged. Mechanical utility has been increased by the use of a honeycomb optical table, mechanically rigid yet adjustable optical component mounts, and a camera focus translation stage. The upgraded instrument was used to observe Venus and Saturn.

Wattson, R. B.↗

EOS mapping accuracy study

Studies were performed to evaluate various image positioning methods for possible use in the earth observatory satellite (EOS) program and other earth resource imaging satellite programs. The primary goal is the generation of geometrically corrected and registered images, positioned with respect to the earth's surface. The EOS sensors which were considered were the thematic mapper, the return beam vidicon camera, and the high resolution pointable imager. The image positioning methods evaluated consisted of various combinations of satellite data and ground control points. It was concluded that EOS attitude control system design must be considered as a part of the image positioning problem for EOS, along with image sensor design and ground image processing system design. Study results show that, with suitable efficiency for ground control point selection and matching activities during data processing, extensive reliance should be placed on use of ground control points for positioning the images obtained from EOS and similar programs.

Forrest, R. B.↗

Gated truncated readout system

A gated truncated readout system for position sensitive or imaging detectors that improves resolution over traditional readout systems. The readout system includes two or more amplifiers that receive a multichannel output analog data from the detector. Analog gates control circuitry, included in the readout circuit, receives the signals from the amplifiers, determines a fractional value of the sum-integral of the signals, and enables analog gates operation around an area of interest, disabling all other channels where noise dominates the signal value and thereby improving interpolation accuracy of the signals centroid position and the detector resolution. Filtered signals are transmitted to a centroid interpolation signal processing device for computation of the centroid position. As a result disabling all channels where noise dominates the signal value, the gated truncated readout system provides better accuracy improved detector resolution.

Popov, Vladimir↗

SU-D-9A-04: Brain PET/CT Imaging On a Scanner with a Large Axial Field-Of-View

Purpose: Large axial field-of-view (FOV) PET/CT scanners are valued for high sensitivity. Brain PET image quality may depend on the head position within the FOV. We investigated the precision of activity estimation for brain PET imaging when the brain was positioned at the end (END) and in the middle (CEN) of the FOV. The additional CT dose for the CEN position was recorded. Methods: An image quality (Jaszczak) phantom and a striatal phantom were filled with F-18 and positioned in END and CEN locations. For each phantom and each location, we acquired a ∼1-hr listmode PET, rebinned the data into 10 frames with equal number of coincidence events, and reconstructed each frame using an iterative algorithm. For the striatal phantom, END and CEN were compared by drawing on each image three regions of interest (ROI) in axially separated uniform areas. The standard deviation of the activity estimation within each ROI was averaged over the 10 images. The coefficient of variation (CV) for activity estimation was calculated at each position. Image quality was assessed by inspecting the resolution bar pattern in the Jaszczak phantom at two different head positions. Results: The CV was the lowest for ROIs near the center of the FOV. For slices near the end, not only was the CV highest, but also the resolution pattern was degraded. CTDIvol summarized in the dose report indicated that the CT dose was ∼ 10% higher for CEN as compared to END position. Conclusion: Positioning the brain in the middle of the FOV in a large FOV PET/CT scanner allows more precise measurement of tracer uptake and better image quality at the cost of increased CT dose. For the end location longer scan times may minimize image quality degradation without any additional CT dose.

60 APPLIED LIFE SCIENCES↗

Development of a pixelated GSO gamma camera system with tungsten parallel hole collimator for single photon imaging

Purpose: In small animal imaging using a single photon emitting radionuclide, a high resolution gamma camera is required. Recently, position sensitive photomultiplier tubes (PSPMTs) with high quantum efficiency have been developed. By combining these with nonhygroscopic scintillators with a relatively low light output, a high resolution gamma camera can become useful for low energy gamma photons. Therefore, the authors developed a gamma camera by combining a pixelated Ce-doped Gd{sub 2}SiO{sub 5} (GSO) block with a high quantum efficiency PSPMT. Methods: GSO was selected for the scintillator, because it is not hygroscopic and does not contain any natural radioactivity. An array of 1.9 mm x 1.9 mm x 7 mm individual GSO crystal elements was constructed. These GSOs were combined with a 0.1-mm thick reflector to form a 22 x 22 matrix and optically coupled to a high quantum efficiency PSPMT (H8500C-100 MOD8). The GSO gamma camera was encased in a tungsten gamma-ray shield with tungsten pixelated parallel hole collimator, and the basic performance was measured for Co-57 gamma photons (122 keV). Results: In a two-dimensional position histogram, all pixels were clearly resolved. The energy resolution was {approx}15% FWHM. With the 20-mm thick tungsten pixelated collimator, the spatial resolution was 4.4-mm FWHM 40 mm from the collimator surface, and the sensitivity was {approx}0.05%. Phantom and small animal images were successfully obtained with our developed gamma camera. Conclusions: These results confirmed that the developed pixelated GSO gamma camera has potential as an effective instrument for low energy gamma photon imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Facile method to stain the bacterial cell surface for super-resolution fluorescence microscopy

A method to fluorescently stain the surfaces of both Gram-negative and Gram-positive bacterial cells compatible with super-resolution fluorescence microscopy is presented. This method utilizes a commercially-available fluorescent probe to label primary amines at the surface of the cell. We demonstrate efficient staining of two bacterial strains, the Gram-negative Shewanella oneidensis MR-1 and the Gram-positive Bacillus subtilis 168. Using structured illumination microscopy and stochastic optical reconstruction microscopy, which require high quantum yield or specialized dyes, we show that this staining method may be used to resolve the bacterial cell surface with sub-diffraction-limited resolution. We further use this method to identify localization patterns of nanomaterials, specifically cadmium selenide quantum dots, following interaction with bacterial cells.

Bacterial↗