Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Shifting the Intertial Navigation Paradigm with the MEMS Technology

"Why don't you use MEMS?" is of the most common questions posed to navigation systems engineers designing inertial navigation solutions in the modern era. The question stems from a general understanding that great strides have been made in terrestrial MEMS accelerometers and attitude rate sensors in terms of accuracy, mass, and power. Yet, when compared on a unit-to-unit basis, MEMS devices do not provide comparable performance (accuracy) to navigation grade sensors in several key metrics. This paper will propose a paradigm shift where the comparison in performance is between multiple MEMS devices and a single navigation grade sensor. The concept is that systematically, a sufficient number of MEMS sensors may mathematically provide comparable performance to a single navigation grade device and be competitive in terms power and mass allocations when viewed on a systems level. The implication is that both inertial navigation system design and fault detection, identification, and recovery could benefit from a system of MEMS devices in the same way that swarm sensing has benefited Earth observation and astronomy. A survey of the state of the art in inertial sensor accuracy scaled by mass and power will be provided to show the scaled error in MEMS and navigation graded devices, a mathematical comparison of multi-unit to single-unit sensor errors will be developed, and preliminary application to an Orion lunar skip atmospheric entry trajectory will be explored.

Crain, Timothy P., II↗

High-Performance Computing Based EMT Simulation of Large PV or Hybrid PV Plants

Faults in the transmission grid have led to reduced power generation from power electronics resources that are typically not connected to the faulted transmission line. In many of the cases, partial loss of power is observed within the power electronics resources like large photovoltaic (PV) power plants. This phenomena is not captured in existing simulation models and/or simulators. High-fidelity switched system electromagnetic transient (EMT) dynamic models of PV power plants can improve the fidelity of models available for accurate analysis of the impact on PV plants during simulation of faults. However, these models are extremely computationally expensive and take a long time to simulate. Long simulation times limit the ability to use these models as larger regions are studied in EMT simulations with more power electronics resources. In this paper, numerical simulation algorithms are combined with high-performance computing techniques and applied to the high-fidelity switched system EMT model of PV plants. Using these techniques, a speed-up of up to 58x is obtained, while preserving the accuracy of the simulation at greater than 98%.

Debnath, Suman↗

Predictive Dynamic Simulation for Large-Scale Power Systems through High-Performance Computing

Power system dynamic simulation solves a set of differential-algebraic equations to determine the time-series trajectory when the system is subject to disturbances such as a short-circuit fault, generator tripping, or line switching. Due to computational inefficiency, dynamic simulation, though widely used for off-line studies, has not been used in real-time operation. That limits the ability to operate a much-evolved power system with significant dynamic and stochastic behaviors introduced by the increasing penetration of renewable generation and the deployment of smart grid technologies. The need for performing dynamic simulation in real-time or faster than real-time for power grid operation becomes apparent. And such predictive dynamic simulation can enable many new power grid operation functions such as real-time path rating. To improve the computational efficiency of dynamic simulation requires parallel computing implementation of the solution methods, as computers no longer have a single core. This paper examines the equations of power system dynamic simulation and implements a parallel version of dynamic simulation. The testing results clearly show the performance has been significantly improved, and dynamic simulation of a large-scale power system with a size equivalent to the Western U.S. power grid achieves, for the first time, a performance of three times faster than real time. The potential of predictive dynamic simulation is also discussed.

differential algebraic equations↗

Evaluation of an Enhanced Bank of Kalman Filters for In-Flight Aircraft Engine Sensor Fault Diagnostics

In this paper, an approach for in-flight fault detection and isolation (FDI) of aircraft engine sensors based on a bank of Kalman filters is developed. This approach utilizes multiple Kalman filters, each of which is designed based on a specific fault hypothesis. When the propulsion system experiences a fault, only one Kalman filter with the correct hypothesis is able to maintain the nominal estimation performance. Based on this knowledge, the isolation of faults is achieved. Since the propulsion system may experience component and actuator faults as well, a sensor FDI system must be robust in terms of avoiding misclassifications of any anomalies. The proposed approach utilizes a bank of (m+1) Kalman filters where m is the number of sensors being monitored. One Kalman filter is used for the detection of component and actuator faults while each of the other m filters detects a fault in a specific sensor. With this setup, the overall robustness of the sensor FDI system to anomalies is enhanced. Moreover, numerous component fault events can be accounted for by the FDI system. The sensor FDI system is applied to a commercial aircraft engine simulation, and its performance is evaluated at multiple power settings at a cruise operating point using various fault scenarios.

Kobayashi, Takahisa↗

Integrated Diagnostics and Prognostics for the Electrical Power System of a Planetary Rover

For electric vehicles, technology for monitoring, diagnosis, and prognosis of the electrical power system (EPS) becomes essential for safe and efficient operation. To this end, we develop a general system-level integrated diagnosis and prognosis framework, which detects, isolates, and identifies EPS faults, and predicts when the EPS will fail to deliver sufficient power. The approach takes advantage of recent work in structural model decomposition in order to distribute the global diagnosis and prognosis problems into local subproblems that can be solved in parallel, thus enabling implementation on distributed computational platforms. The framework is applied to the EPS of a planetary rover testbed, and is demonstrated using data from field experiments.

Daigle, Matthew↗

Cooperative fault management for resilient integration of renewable energy

Cooperative fault management (CFM) is designed herein to control different types of renewable energy resources cooperatively during electrical faults. This paper studies systems with a high penetration of photovoltaic (PV) energy and wind energy. First, CFM leverages power converters of PV farms to boost the ride-through capability of nearby doubly-fed induction generators (DFIGs). By controlling PV farms’ output voltages to change smoothly during both fault initiation and fault clearance, the widely used crowbar in DFIGs is less likely to be activated. Crowbar activation adversely makes DFIGs lose controllability and absorb reactive power. The second contribution is the development of a software-defined CFM controller and a controller in-the-loop demonstration of the real-time performance of this optimization-based CFM. CFM capitalizes on distributed optimization formulation to enable flexibility, plug-and-play, and privacy-preserving. Computation time, however, is a major concern for optimization-based dynamics control. Here, real-time controller-in-the-loop simulation results show optimization-based CFM can output reference values around 60 ms and is quick enough for dynamic control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Resilient Distributed Frequency Regulation of Renewable Generators under Communication Interruptions

Modern power systems (MPSs) face significant challenges due to the high penetration of renewable energy sources (RESs) and new types of loads such as electric vehicles (EVs). Traditional load frequency control (LFC) methods struggle with the intermittent, stochastic nature of RESs, the near-zero inertia of power-electronics-based generators, and the mobility of controllable loads and battery systems. This paper introduces a novel resilient distributed frequency regulation method to address these issues. The proposed method employs a state space model to represent the dynamic behavior of participating power sources while accounting for stochastic switching processes to model structural and parameter variations caused by disruptions such as generator connection/disconnection, communication interruptions, and physical faults. By integrating these dynamic and stochastic components, the method treats power grids as a comprehensive stochastic hybrid system. Our method enhances conventional frequency control by incorporating local stability control, neighborhood control decoupling, and coordination feedback. Theoretical analyses establish the stability, convergence, and resilience of the proposed method, and its effectiveness is validated through case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Electrical safety for high voltage arrays

A number of key electrical safety requirements for the high voltage arrays of central station photovoltaic power systems are explored. The suitability of representative industrial DC power switchgear for control and fault protection was evaluated. Included were AC/DC circuit breakers, electromechanical contactors and relays, load interruptors, cold disconnect devices, sectionalizing switches, and high voltage DC fuses. As appropriate, steady state and transient characteristics were analyzed. Failure modes impacting upon operation and maintenance safety were also identified, as were the voltage withstand and current interruption levels.

Marshall, N. A.↗

Automated Power-Distribution System

Autonomous power-distribution system includes power-control equipment and automation equipment. System automatically schedules connection of power to loads and reconfigures itself when it detects fault. Potential terrestrial applications include optimization of consumption of power in homes, power supplies for autonomous land vehicles and vessels, and power supplies for automated industrial processes.

Ashworth, Barry↗

Hybrid Electric MC-12 Ground Testing Plan Chapter

In the commercial aviation world, hybrid/electric propulsion is a promising technology for fuel, emissions, and noise reduction in support of the challenging goals established by 2050 EU Flightpath/SRIA, NASA ARMD Strategic Implementation Plan, and the US Air Force ATTAM programs. Ongoing results indicate operational benefits are possible in those three technical areas. Considering military applications, hybrid/electric propulsion may yield further significant improvements by enabling new, unorthodox mission capabilities. Potential benefits are expected in the areas of vehicle signature reduction (lower noise, lower exhaust signature), usage in enhanced flight environments, minimized human-in-the-loop workload by offering a platform compatible with future goals of autonomous operations facilitation, maintenance cost reductions, and performance burst/dash energy. Additional synergies are likely when used in conjunction with energy weapons. Some potential areas of mutual interest could include, dusty operations capability, remote supply capability, extended surveillance, dispatch able power, fuel-flexible vehicles, and autonomous rescue equipment. Many of the key technologies that have been demonstrated in ground operation must now be qualified for altitude conditions. We expect to have many flight qualified powertrain systems over the next decade for military planners to choose from for new future battlefield capability. This requires new flight-weight and flight-efficient powertrain components, fault tolerant power management, and electromagnetic interference mitigation technologies. Moreover, initial studies indicate some combination of ambient and cryogenic thermal management and relatively high bus voltages when compared to state of practice will be required to achieve a net system benefit. Developing all these powertrain technologies within a realistic aircraft architectural geometry and under realistic operational conditions requires a unique electric aircraft test bed. The MC-12 surveillance aircraft is an ideal military aircraft for demonstrating some of the benefits of incorporating hybrid electric propulsion. This report details an approach for full-scale ground-based altitude testing the hybrid electric MC-12 powertrain through a full flight profile.

military electric aircraft propulsion↗

High-Voltage DC MULTI-terminal SIMulation (HVDC MULTISIM): Technical Program Summary

Expansion of the power grid in the USA is essential to fulfilling the rising energy demand of the country. In particular, the transmission grid, a network of electrical energy corridors that enable the flow of large amounts of energy from the point of generation to the point of consumption, needs significant expansion to cater to this growth of electrification. The current infrastructure is also dated, and any new transmission corridor should be based on a vision of building a modern infrastructure that is futureproof. High voltage DC (HVDC) transmission technology falls in this category: it is the most economical way to build large transmission lines and relies on sophisticated electronics and flexible controls, rather than just passive components like switchgear and transformers. This project is aimed at establishing the technical and economic feasibility of a network of HVDC lines that are interconnected to form a multi-terminal DC network. HVDC transmission is not a new technology and United States has a number of such lines; however, these are point to point transmissions and do not form a DC grid. Modeling and analyzing DC grids is challenging since there are no established modeling tools and the traditional ways of modeling AC grids fall short of providing the fidelity required the fast dynamics of the DC grid. This project aims to build a software-in-the-loop simulator for a multi-terminal HVDC grid, called MULTISIM and, establish new control and protection algorithms to operate such a connected DC system. NLR, a key partner, established the core framework of the MULTISIM simulator and validated its functionality. The GE Vernova team, created a full-scale model of a four-terminal HVDC network using PSCAD (Power Systems Computer Aided Design) software and established the baseline performance of the system during normal and fault operation. The project was started on 10/12024 with a kick-off meeting held on 12/11/2024 and ran through two quarters till termination. All the tasks, milestones and deliverables during this period were met. Several interim reports detailing the various tasks were submitted. The following sections provide details on the completed tasks till the project pause and termination after Q2.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Operational Resilience Metric to Evaluate Inertia and Inverter-based Generation on the Grid

In an effort to reduce carbon emissions and curtail the effects of climate change there has been considerable effort to increase the penetration of inverter-based renewable energy sources. The adoption of renewable generation over conventional inertia-based generation sources is forming considerable challenges for the operation and stability of the power system. The power system has been designed around generation units characterized by high inertia and primary frequency response (PFR), allowing them to respond to disturbances such as faults or generators tripping off line. In contrast, the modern inverter-based assets are characterized by no contribution to inertia and they typically provide stochastic generation at their maximum output, thus having no contribution to PFR during low-frequency disturbance events. Because of this, inertia in power systems is reducing, resulting in a faster rate of frequency change after a disturbance occurs. As more inverter-based generation units are added to the grid it is important to understand the stability of the system and the size of disturbance a system is capable of withstanding. This paper presents a resilience metric that evaluates the maximum size of disturbance a systems can withstand based on the system inertia and the primary frequency control of inverter and inertia-based generation. The results are shown visually and are based on the real-time operation of generation units and their characteristics such as latency, ramp rates, and energy constraints. It is demonstrated that the real-time positioning or bias of the generating units has an effect of the size of disturbance that a system can withstand, i.e. its resilience. It is expected that this type of analysis can help operators increase the resilience of power systems in the future.

13 HYDRO ENERGY↗

Development of Hydrologic Characterization Technology of Fault Zones -- Phase I, 2nd Report

This is the year-end report of the 2nd year of the NUMO-LBNL collaborative project: Development of Hydrologic Characterization Technology of Fault Zones under NUMO-DOE/LBNL collaboration agreement, the task description of which can be found in the Appendix 3. Literature survey of published information on the relationship between geologic and hydrologic characteristics of faults was conducted. The survey concluded that it may be possible to classify faults by indicators based on various geometric and geologic attributes that may indirectly relate to the hydrologic property of faults. Analysis of existing information on the Wildcat Fault and its surrounding geology was performed. The Wildcat Fault is thought to be a strike-slip fault with a thrust component that runs along the eastern boundary of the Lawrence Berkeley National Laboratory. It is believed to be part of the Hayward Fault system but is considered inactive. Three trenches were excavated at carefully selected locations mainly based on the information from the past investigative work inside the LBNL property. At least one fault was encountered in all three trenches. Detailed trench mapping was conducted by CRIEPI (Central Research Institute for Electric Power Industries) and LBNL scientists. Some intriguing and puzzling discoveries were made that may contradict with the published work in the past. Predictions are made regarding the hydrologic property of the Wildcat Fault based on the analysis of fault structure. Preliminary conceptual models of the Wildcat Fault were proposed. The Wildcat Fault appears to have multiple splays and some low angled faults may be part of the flower structure. In parallel, surface geophysical investigations were conducted using electrical resistivity survey and seismic reflection profiling along three lines on the north and south of the LBNL site. Because of the steep terrain, it was difficult to find optimum locations for survey lines as it is desirable for them to be as straight as possible. One interpretation suggests that the Wildcat Fault is westerly dipping. This could imply that the Wildcat Fault may merge with the Hayward Fault at depth. However, due to the complex geology of the Berkeley Hills, multiple interpretations of the geophysical surveys are possible. iv An effort to construct a 3D GIS model is under way. The model will be used not so much for visualization of the existing data because only surface data are available thus far, but to conduct investigation of possible abutment relations of the buried formations offset by the fault. A 3D model would be useful to conduct 'what if' scenario testing to aid the selection of borehole drilling locations and configurations. Based on the information available thus far, a preliminary plan for borehole drilling is outlined. The basic strategy is to first drill boreholes on both sides of the fault without penetrating it. Borehole tests will be conducted in these boreholes to estimate the property of the fault. Possibly a slanted borehole will be drilled later to intersect the fault to confirm the findings from the boreholes that do not intersect the fault. Finally, the lessons learned from conducting the trenching and geophysical surveys are listed. It is believed that these lessons will be invaluable information for NUMO when it conducts preliminary investigations at yet-to-be selected candidate sites in Japan.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Risk informed cyber security for nuclear power plants - 342

Nuclear power plants are increasingly adding digital components for plant operation, safety, and security. These digital components fill a gap with legacy equipment where replacement components no longer exist. They also benefit operation of the plant by increasing efficiency in power generation, monitoring of equipment and plant parameters, as well as aiding operator control. However, the addition of digital components and systems also adds cyber risks with previously unanalyzed failure modes and attack vectors are introduced with these new systems. These risks are difficult to identify, analyze, and mitigate due to the increasingly complex nature of the digital components and the integration of these components with additional plant processes and communication networks. The research presented in this paper develops a new method that addresses the cyber risk to inform appropriate levels of protection. EPRI and Sandia are working under a Cooperative Research and Development Agreement to develop an effective method of evaluating the cyber risk in production nuclear power facilities. The Cyber Hazards Analysis Risk Methodology (CHARM) focuses on ensuring adequate controls are in place for appropriate cyber protection of the plant from radiological release or generation risk. Existing plant hazards analyses (e.g., PRA, FTA) do not account for software deficiencies or adversarial intent. This method leverages existing plant analyses and MIT's Systems Theoretic Process Analysis (STPA) to create cyber informed fault trees. These new fault trees will provide the basis for comprehensive cyber risk analysis and help ensure potential gaps in cyber security controls are identified and corrected. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding Power Systems Protection in the Clean Energy Future

Wind and solar power and battery energy storage are often referred to as inverter-based resources (IBRs), which means they rely on power electronics (inverters) to generate grid-compatible electricity. This is unlike the fossil, nuclear, and hydroelectric plants that use spinning synchronous generators that have provided nearly all U.S. electricity until recently. Synchronous generators can inherently provide several services used to maintain a safe and stable grid and as they are replaced with IBRs it becomes important to understand how these services can be provided. One of these services is fault current, or the ability to inject large amounts of current during a short circuit. This current can easily be detected with low-cost equipment such as circuit breakers. IBRs do not inherently produce large amounts of fault current, and this may eventually require finding alternative sources of fault current or new system protection schemes. This document describes several alternative approaches to maintaining fault current protection and provide a safe, reliable power grid.

14 SOLAR ENERGY↗

GMLC Southeast Regional Consortium: Technology Driven Improvements to Power Grid Resiliency

Recognizing that electric grid challenges can differ by geographical regions across the US, the Department of Energy (DOE) created a pioneer regional partnership to provide technical assistance to stakeholders facing grid modernization challenges. The southeast regional teams will transfer technologies developed under DOE auspices to stakeholders for testing, evaluation, and market validation. Regional members will help define critical challenges and pave the way for transition of technologies to the commercial sector. Using the depth and expertise at Oak Ridge National Laboratory, Savannah River National Laboratory, University of Tennessee’s CURENT, CAPER and the Clemson 20 MVA Electrical Grid Laboratory—along with critical industry partners, such as Duke Energy, TVA, Southern Company, EPB, and Santee Cooper—the Southeast Regional Consortium team will conduct collaborative research to advance the state of the grid in the Southeast region and improve power system resiliency to enhance responsiveness, enable faster restoration of power, and increase distributed energy resource (DER) concentrations. This report provides details of the technical research and demonstration projects accomplished by Oak Ridge National Laboratory (ORNL) as part of the Southeast Regional Consortium. Specifically, ORNL analyzed the application of optical current and voltage measurements impedance relays which would enable step distance protection to be deployed on distribution systems. This would improve the precision of determining the geographic location of faults, increase network topology flexibility, and allow bi-directional power flow. Next, ORNL deployed time sensitive networking technology on the EPB fiberoptic data network to study the impact of increased sensor traffic on existing supervisory control and data acquisition data. The deterministic latency and high bandwidth were demonstrated by remotely inspecting a substation using a drone with full HD streaming video operated at the EPB Control Center. Finally, a new application-based communication and control system developed at ORNL call CSEISMIC was tested for future deployment on the EPB Control Center microgrid using a hardware-in-the-loop testbed that was also developed at ORNL. The controller was able to successfully optimize ancillary service when the microgrid is connected to the distribution network. The seamless islanding, resynchronization, and reconnection of the microgrid was also demonstrated through the testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗