Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Recovery Act: Strategies for Voltage Control and Transient Stability Assessment

As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation differs from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs.

17 WIND ENERGY↗

Stability Quantification for Consensus-Based Power Flow Control between Transmission and Distribution Power Systems

With increasing integration of distributed energy resources (DERs), distribution systems (DS) with DERs are expected to provide proactive grid services. The result is that power references, or known as dispatch signals, required for DS can become faster changing than in legacy power system. Consensus-based integral controls have been proposed for the purpose of coordinating power generations of DERs in DS to match the power references. These existing controls assume the integral control signal to be sufficiently slow or constant, and ignore the potential dynamics of the integral controller when tracking more varying power references. Therefore, in this paper we present an improvement for such controls by deriving the stability condition utilizing generalized Nyquist criterion. The stability condition is quantified by a set of integral gains that guarantee stability in closed-loop system without assuming a constant integral signal. A rule-of-thumb criterion is also derived to instruct the design of the consensus topology that can provide faster convergence rate for the closed-loop system. Here, the stability and convergence improvements developed in this paper are demonstrated and verified through numerical examples.

42 ENGINEERING↗

Design of the Pacific DC Intertie Wide Area Damping Controller

This study describes the design and implementation of a proof-of-concept Pacific DC Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV DCtransmission line in the WI. The control system utilizes real-time phasor measurement unit feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Graph Convolutional Network-Based Topology Embedded Deep Reinforcement Learning for Voltage Stability Control

Topological variations in power system is a common phenomenon and can impose significant challenges to traditional controllers of power system. Recent study revealed the strength of deep reinforcement learning (DRL) based approaches in power system preventive and corrective control. But topological variations are difficult to capture using classical fully connected neural network (FCN) model and has not been explicitly modeled in previous work. Hence, we develop a Graph Convolutional Network (GCN) based DRL framework to tackle topology changes in control design of power system. The GCN model exploits the graph structure of the power network and helps the DRL agent to embed the topology information during learning process. Our GCN based approach is evaluated using the IEEE-39 bus system and it outperforms the FCN-based DRL scheme in terms of training convergence and control performance considering grid topology changes.

Hossain, Ramij Raja↗

Neural Networks-Based Inverter Control: Modeling and Adaptive Optimization for Smart Distribution Networks

The optimal voltage control of inverter-based resources, especially under the high penetration of solar photovoltaics, is critical to the stability of the distribution power system. However, the computational complexity as well as the coordinated operation performance of the voltage control optimization in the distribution power system limits the real-time applications. To mitigate this issue, a model-free based adaptive optimal control scheme for the smart inverter is proposed to maximize the active power generation, minimize the power loss, and maintain the bus voltages in smart distribution networks. An inverter-based optimization model for coordinated operation is first established, considering the uncertainties of renewable power generation. Subsequently, by collecting the data and control strategies, the neural networks (NNs) based algorithm is proposed to efficiently predict the best possible control strategy. The main objective of this scheme is to accurately predict candidate optimal solutions with near-negligible feasibility and optimization gaps, with the advantage of avoiding complicated iteration-based numerical algorithms. Thereafter, the co-simulation among OpenDSS, MATLAB, and Python is set up to fully take advantage of the three individual software. Experiments are conducted based on different control parameter characteristics and structures of NNs. Finally, the results reveal that an average mean squared error of 0.013 and 1 ms response time are achieved, which is lower than some state-of-the-art methods.

42 ENGINEERING↗

Diesel fuel long term storage and treatment- recommended tests and practices (U)

The Clean Air Act (1970) is the comprehensive federal law that regulates air emissions from stationary and mobile sources. Among other things, this law authorized the Environmental Protection Agency (EPA) to establish National Ambient Air Quality Standards to protect public health and public welfare and to regulate emissions of hazardous air pollutants. In recent years, EPA regulations have forced oil refineries into producing a very low sulfur diesel fuel and incentives for adding up to 5% bio-diesel. These changes to the fuel oil formulation are beneficial to air quality and to energy conservation, but adversely impact heat content, long term storage stability, engine power, and injection system reliability. Diesel engines typically have a high incidence of injector failure resulting from poor diesel fuel quality. Since standby diesel engines do not run continuously it is necessary to implement periodic surveillance's to ensure the quality of diesel fuel is acceptable for reliable operation when a loss of power occurs. The information contained in this document is a compilation of best practices to be used as a guide for maintenance of a reliable diesel fuel system.

54 ENVIRONMENTAL SCIENCES↗

Decomposition of Nonlinear Dynamical Systems Using Koopman Gramians

In this paper we propose a new Koopman operator approach for nonlinear model decomposition using Koopman gramians. We introduce Koopman operators and discuss the notion of a input-Koopman operator. We show how input-Koopman operators can be used to cast a nonlinear system into the classical state-space form, as well as conditions under which input and state observable functions are well separated. We extend an existing method of dynamic mode decomposition for learning Koopman operators from data known as deep dynamic mode decomposition, for systems with control or disturbances. We illustrate the accuracy of the method on learning an input-state separable Koopman operator for an example system, even when the underlying system exhibits mixed state-input terms. Finally, we introduce a nonlinear decomposition algorithm, based on Koopman gramians, that maximizes internal subsystem observability and disturbance rejection from unwanted noise in other subsystems. To relieve the NP-hardness of the decomposition problem, we derive a relaxation based on Koopman gramians and multi-way partitioning. We illustrate our algorithm on a swing dynamics model for a IEEE 39 bus and discuss our findings.

Learning, Control, Distributed Control, koopman op↗

Flight experience with advanced controls and displays during piloted curved decelerating approaches in a powered-lift STOL aircraft

A program to assess the feasibility of piloted STOL approaches along predefined, steep, curved, and decelerating approach profiles was carried out with a powered-lift STOL aircraft. To reduce the pilot workload associated with the basic control requirements of a powered-lift aircraft equipped with redundant controls and operating on the backside of the power curve, separate stability augmentation systems for attitude and speed were provided, as well as a supporting flight director and special electronic cockpit displays. The control, display, and procedural features are described for the flight experiment that led to the conclusion that, given an adequate navigation environment, such constrained approaches may be feasible from a pilot acceptance point of view.

Hindson, W. S.↗

Mitigation of Remedial Action Schemes by Decentralized Robust Governor Control

This paper presents transient stability improvement by a new distributed hierarchical control architecture (DHC). The integration of remedial action schemes (RAS) to the distributed hierarchical control architecture is studied. RAS in power systems are designed to maintain stability and avoid undesired system conditions by rapidly switching equipment and/or changing operating points according to predetermined rules. The acceleration trend relay currently in use in the US western interconnection is an example of RAS that trips generators to maintain transient stability. The link between RAS and DHC is through fast acting robust turbine/governor control that can also improve transient stability. In this paper, the influence of the decentralized robust turbine/governor control on the design of RAS is studied. Benefits of combining these two schemes are increasing power transfer capability and mitigation of RAS generator tripping actions; the later benefit is shown through simulations.

Distributed Hierarchical Control↗

Use and Testing of a Wind Turbine for the Supply of Balancing Reserves and Wide-Area Grid Stability

This report documents the use of wind turbine inertial energy for the supply of two specific electric power grid services; system balancing and real power modulation to improve grid stability. Each service is developed to require zero net energy consumption. Grid stability was accomplished by modulating the real power output of the wind turbine at a frequency and phase associated with wide-area modes. System balancing was conducted using a grid frequency signal that was high-pass filtered to ensure zero net energy. Both services used Phasor Measurement Units (PMUs) as their primary source of system data in a feedforward control (for system balancing) and feedback control (for system stability).

17 WIND ENERGY↗

Power system inertia estimation: Review of methods and the impacts of converter-interfaced generations

Understanding and quantifying the inertia of power systems with the integration of converter-interfaced generation (CIG) plays an essential role in the safe transition to a future low-inertia scenario. Here we provide a comprehensive summary of inertia definitions for both synchronous generators and CIGs as well as their corresponding estimation methods. In particular, the estimation methods are categorized as model-based and measurement-based approaches considering both small and large disturbances. The advantages and disadvantages of different methods are carefully discussed. This paper also offers for the first time a framework to quantify the virtual inertia of CIGs at the component and aggregation levels, an open problem in the literature. Finally, future directions for inertia estimation are identified and discussed. This significantly benefits the design of appropriate control and protection schemes in achieving a more reliable, secure, and resilient power system.

42 ENGINEERING↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Existing Methods for Grid Strength Assessment and Role of Hydropower in Future Grids

The power system is undergoing rapid evolution with increasing penetration of inverter-based resources (IBRs), large loads, microgrids, and power electronic devices. Ensuring reliable and stable operation of the modern power grid is a multi-faceted challenge that requires detailed understanding of this complex system. Dynamic stability is a major concern in maintaining the security of power grids as the generation mixes and large loads transitions to include high shares of power electronic devices. The operation of IBRs in regions with low system strength and higher grid impedances has been found to be the main reason behind many of the power system instabilities that manifest themselves in various types of oscillations and interactions that, if not properly addressed and damped, can jeopardize the reliable operation of the power system. Weak grid conditions compound such stability problems, particularly when many IBRs operate in proximity to and connect to weak power grids. Therefore, it is important to assess grid strength for planning, integration and operation of IBRs for a given power system. In this report, we aim to understand and classify existing methodologies for grid strength assessment, along with their limitations and future needs. Further, we aim to utilize the huge untapped potential in utilizing hydro energy resources in addressing some of the pertinent challenges of grid strength and reliable operation of modern power systems. Hydropower, historically valued for its flexibility and dispatchability, now faces new constraints due to reduced share of synchronous machines in the generation mix and seasonal variability of available water resources. Yet, these same plants present untapped potential beyond energy generation - notably, as providers of critical grid services. This report explores how hydropower plants, particularly through operation as synchronous condensers, can play a pivotal role in strengthening the grid amid evolving system dynamics.

13 HYDRO ENERGY↗

Stability Assessment of a System Comprising a Single Machine and a Virtual Oscillator Controlled Inverter with Scalable Ratings

We present a small-signal stability study of a coupled synchronous generator and inverter system, where the inverter is controlled by virtual oscillator control (VOC). VOC is a recently proposed grid-forming inverter control strategy, which acts on faster time scales compared to droop control. In our study, we leverage a scalable VOC controller (that is by design agnostic of power levels) to test the system's small-signal stability at different inverter penetration levels. The impact of rotational inertia, reactive power support, and filter parameters on stability is then investigated. Results highlight possible issues that might arise in these mixed machine-inverter systems further motivating the need to develop next generation stabilizing grid-forming controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review on Simulation Models of Cascading Failures in Power Systems

Among various power system disturbances, cascading failures are considered the most serious and extreme threats to grid operations, potentially leading to significant stability issues or even widespread power blackouts. Simulating power systems' behaviors during cascading failures is of great importance to comprehend how failures originate and propagate, as well as to develop effective preventive and mitigative control strategies. The intricate mechanism of cascading failures, characterized by multi-timescale dynamics, presents exceptional challenges for their simulations. This paper provides a comprehensive review of simulation models for cascading failures, providing a systematic categorization and a comparison of these models. The challenges and potential research directions for the future are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Frequency Event Categorization in Power Distribution Systems Using Micro PMU Measurements

Frequency is an important metric for power stability. To enhance the situational awareness in power distribution systems, this article proposes a data-driven approach that utilizes the data from micro phasor measurement units (μPMU) to categorize frequency events observed in distribution feeders. The proposed approach has three layers, each of which analyzes if a frequency event is propagated from the transmission system, formed inside a distribution feeder or falsely produced by instantaneous frequency (IF) estimation algorithms, respectively. In the first layer, the Granger causality is utilized to compare the causal relations from measurements across different locations to decide if an event is propagated from the transmission side. In the second layer, a trained sparse coding dictionary is utilized to unmix the physical causes of a frequency event. In the third layer, a moving z-score based event-pair detector is applied to identify if a frequency event is algorithm-induced. The proposed approach is tested using the μPMU measurements collected from Lawrence Berkeley National Laboratory (LBNL) and Riverside Public Utility (RPU).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗