Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Magnetospheric mapping with a quantitative geomagnetic field model

Mapping the magnetosphere on a dipole geomagnetic field model by projecting field and particle observations onto the model is described. High-latitude field lines are traced between the earth's surface and their intersection with either the equatorial plane or a cross section of the geomagnetic tail, and data from low-altitude orbiting satellites are projected along field lines to the outer magnetosphere. This procedure is analyzed, and the resultant mappings are illustrated. Extension of field lines into the geomagnetic tail and low-altitude determination of the polar cap and cusp are presented. It is noted that while there is good agreement among the various data, more particle measurements are necessary to clear up statistical uncertainties and to facilitate comparison of statistical models.

Fairfield, D. H.↗

Use of dew-point detection for quantitative measurement of sweating rate

A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

Brengelmann, G. L.↗

Quantitative bioluminescent detection of bacteria

Phosphoflavins in sample are measured using photobacterial luciferase assay technique for flavin mononucleotide (FMN). Boiling perchloric acid is used to rupture cells to free bound flavin and to hydrolyze flavin adenine dinucleotide to FMN. Base-stabilized water solution of sodium borohydride is used as reactant.

Chappelle, E. W.↗

Quantitative comparisons of type 3 radio burst intensity and fast electron flux at 1 AU

The flux of fast solar electrons and the intensity of the type 111 radio emission generated by these particles were compared at one AU. Two regimes were found in the generation of type 111 radiation: one where the radio intensity is linearly proportional to the electron flux, and another, which occurs above a threshold electron flux, where the radio intensity is approximately proportional to the 2.4 power of the electron flux. This threshold appears to reflect a transition to a different emission mechanism.

Fitzenreiter, R. J.↗

The effect of growth phase and medium on the use of the firefly adenosine triphosphate (ATP) assay for the quantitation of bacteria

Luciferase assay for adenosine triphosphate (ATP) was used as a rapid method to determine the number of bacteria in a urine sample after nonbacterial components were removed. Accurate cellular ATP values, determined when bacteria were grown in an environment similar to that in which they were found, were necessary for the calculation of bacterial titer in urine. Cellular ATP values vary depending on the extraction method, the cell growth phase, and cell growth conditions. ATP per cell values of stationary E. coli grown in urine were two times greater than ATP per cell values of cells grown in trypticase soy broth. Glucose and urea were examined as possible components responsible for the cellular ATP variation.

Bush, V. N.↗

Quantitative determination of stratospheric aerosol characteristics

The author has identified the following significant results. In the S192 data, a peak was apparent in the lower altitudes that was not present in the shorter wavelengths and grew with increasing wavelength beginning with band 7. For ten S192 wavelengths, the relative altitude increment was determined by knowledge of the relative position of the highest point in the scan arc. Using this scheme, results of scaling and inverting data for passes 47 and 61 were put into two models. Each result had three chart representations: (1) limb brightness measurement, (2) attenuation coefficients, and (3) ratio of the aerosol and Rayleigh coefficients to accentuate layers.

Tingey, D. L.↗

Quantitative observation of light flash sensations experiment MA-106

Light flashes caused by the interaction of cosmic particles with the visual apparatus have been observed by astronauts on all space missions since Apollo 11. This Apollo Soyuz Test Project experiment compared measurements of the observer's visual sensitivity with measurements of the ambient radiation environment and with the frequency and character of the flashes observed. The data obtained reveal a latitude dependence of the frequency of observed flashes. This distribution of flashes is correlated with the distribution of cosmic particles with stopping power greater than 15 keV/ micrometers in the eye. The interaction of dark adaptation, specific ionization, and range of particles in the retina as factors in the visualization of particle passage is discussed.

Budinger, T. F.↗

Use of LARS system for the quantitative determination of smoke plume lateral diffusion coefficients from ERTS images of Virginia

A technique for measuring smoke plume of large industrial sources observed by satellite using LARSYS is proposed. A Gaussian plume model is described, integrated in the vertical, and inverted to yield a form for the lateral diffusion coefficient, Ky. Given u, wind speed; y sub l, the horizontal distance of a line of constant brightness from the plume symmetry axis a distance x sub l, downstream from reference point at x=x sub 2, y=0, then K sub y = u ((y sub 1) to the 2nd power)/2 x sub 1 1n (x sub 2/x sub 1). The technique is applied to a plume from a power plant at Chester, Virginia, imaged August 31, 1973 by LANDSAT I. The plume bends slightly to the left 4.3 km from the source and estimates yield Ky of 28 sq m/sec near the source, and 19 sq m/sec beyond the bend. Maximum ground concentrations are estimated between 32 and 64 ug/cu m. Existing meteorological data would not explain such concentrations.

Blais, R. N.↗

Quantitative sediment mapping from remotely sensed multispectral data

Multiple regression techniques were used to correlate ERTS-1 data with measured values of suspended sediment. The resultant equation was applied to a different ERTS scene using a deepwater area for atmospheric calibration. This approach provides greater accuracy than previously reported methods. Suspended sediment contours are plotted for the Potomac River, Virginia, using Chesapeake Bay deep water for atmospheric calibration.

Johnson, R. W.↗

Acquisition of quantitative physiological data and computerized image reconstruction using a single scan TV system

A single-scan radiography system has been interfaced to a minicomputer, and the combined system has been used with a variety of fluoroscopic systems and image intensifiers available in clinical facilities. The system's response range is analyzed, and several applications are described. These include determination of the gray scale for typical X-ray-fluoroscopic-television chains, measurement of gallstone volume in patients, localization of markers or other small anatomical features, determinations of organ areas and volumes, computer reconstruction of tomographic sections of organs in motion, and computer reconstruction of transverse axial body sections from fluoroscopic images. It is concluded that this type of system combined with a minimum of statistical processing shows excellent capabilities for delineating small changes in differential X-ray attenuation.

Baily, N. A.↗

Quantitative measurement of the "feel" of fabric

Device handle of fabric is a property related to flexibility, pliability, or compressibility. Technique requires extraction of flat circular sample of fabric through convergent nozzle.

Alley, V. L., Jr.↗

Quantitative three-dimensional dynamic imaging of structure and function of the cardiopulmonary and circulatory systems in all regions of the body

The background for, and design of a third generation, general purpose, all electronic spatial scanning system, the DSR is described. Its specified performance capabilities provide dynamic and stop action three dimensional spatial reconstructions of any portion of the body based on a minimum exposure time of 0.01 second for each 28 multiplanar 180 deg scanning set, a maximum scan repetition rate of sixty 28 multiplane scan sets per second, each scan set consisting of a maximum of 240 parallel cross sections of a minimum thickness of 0.9 mm, and encompassing a maximum cylindrical volume about 23 cm in length and up to 38 cm in diameter.

Sturm, R. E.↗

Acquisition of quantitative physiological data and computerized image reconstruction using a single scan TV system

Single scan operation of television X-ray fluoroscopic systems allow both analog and digital reconstruction of tomographic sections from single plan images. This type of system combined with a minimum of statistical processing showed excellent capabilities for delineating small changes in differential X-ray attenuation. Patient dose reduction is significant when compared to normal operation or film recording. Flat screen, low light level systems were both rugged and light in weight, making them applicable for a variety of special purposes. Three dimensional information was available from the tomographic methods and the recorded data was sufficient when used with appropriate computer display devices to give representative 3D images.

Baily, N. A.↗