Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

SU-D-16A-03: A Radiation Pneumonitis Dose-Response Model Incorporating Non- Local Radiation-Induced Bystander Effect

Purpose: Dose-response models that can reliably predict radiation pneumonitis (RP) to guide radiation therapy (RT) for lung cancer presently do not exist. A model is proposed that incorporates non-local radiationinduced bystander effect (RIBE). Methods: A single sigmoid response function, derived from published data for whole lung irradiation, relates RP probability to cumulative lung damage, regardless of fractionation scheme. Lung damage is assumed to be caused by direct local radiation damage, quantified via the linear-quadratic (LQ) model, and RIBE. Based on published data, RIBE is assumed to be activated when per-fraction dose rises above ∼0.6 Gy, but is constant with dose above that threshold. Integral RIBE damage is assumed proportional to lung volume irradiated above ∼0.6 Gy per fraction. Key model parameters include LQ α and β, and two RIBE parameters: the single-fraction probability δ of damage, and a proportionality parameter κ that relates the potential for RIBE damage to irradiated lung volume. All parameters are tentatively fitted from published data, the RIBE parameters from published RP rates for conventionally fractionated RT (CFRT) and stereotactic body RT (SBRT). Results: The model predicts dose-response curves that are consistent with clinical experience. It provides a tentative explanation for why V20 (33 fractions), V13 (20 fractions) and V5 (<10 fractions) are observed to be correlated with RP. It also provides a plausible explanation for the success of SBRT — RIBE damage increases with the number of fractions, so penalizes CFRT relative to SBRT. Conclusion: The proposed model is relatively simple, extrapolates from published data, plausibly explains several clinical observations, and produces dose-response curves that are consistent with clinical experience. While capable of elaboration, its ability to explain doseresponse experience with different fractionation schemes using a small number of assumptions and parameters is an advantage.

60 APPLIED LIFE SCIENCES↗

SU-E-T-300: Dosimetric Comparision of 4D Radiation Therapy and 3D Radiation Therapy for the Liver Tumor Based On 4D Medical Image

Purpose: The purpose of this work was to determine the dosimetric benefit to normal tissues by tracking liver tumor dose in four dimensional radiation therapy (4DRT) on ten phases of four dimensional computer tomagraphy(4DCT) images. Methods: Target tracking each phase with the beam aperture for ten liver cancer patients were converted to cumulative plan and compared to the 3D plan with a merged target volume based on 4DCT image in radiation treatment planning system (TPS). The change in normal tissue dose was evaluated in the plan by using the parameters V5, V10, V15, V20,V25, V30, V35 and V40 (volumes receiving 5, 10, 15, 20, 25, 30, 35 and 40Gy, respectively) in the dose-volume histogram for the liver; mean dose for the following structures: liver, left kidney and right kidney; and maximum dose for the following structures: bowel, duodenum, esophagus, stomach and heart. Results: There was significant difference between 4D PTV(average 115.71cm3 )and ITV(169.86 cm3). When the planning objective is 95% volume of PTV covered by the prescription dose, the mean dose for the liver, left kidney and right kidney have an average decrease 23.13%, 49.51%, and 54.38%, respectively. The maximum dose for bowel, duodenum,esophagus, stomach and heart have an average decrease 16.77%, 28.07%, 24.28%, 4.89%, and 4.45%, respectively. Compared to 3D RT, radiation volume for the liver V5, V10, V15, V20, V25, V30, V35 and V40 by using the 4D plans have a significant decrease(P≤0.05). Conclusion: The 4D plan method creates plans that permit better sparing of the normal structures than the commonly used ITV method, which delivers the same dosimetric effects to the target.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-08: Novel Iron-Based Radiation Reporting Systems as 4D Dosimeters for MR-Guided Radiation Therapy

Purpose: To compare novel radiation reporting systems utilizing ferric ion (Fe{sup 3+}) reduction versus ferrous ion (Fe{sup 2+}) oxidation in gelatin matrixes for 3D and 4D (3D+time) MR-guided radiation therapy dosimetry. Methods: Dosimeters were irradiated using an integrated 1.5T MRI and 7MV linear accelerator (MR-Linac). Dosimeters were read-out with both a spectrophotometer and the MRI component of the MR-Linac immediately after irradiation. Changes in optical density (OD) were measured using a spectrophotometer; changes in MR signal intensity due to the paramagnetic differences in the iron ions were measured using the MR-Linac in real-time during irradiation (balanced-FFE sequences) and immediately after irradiation (T{sub 1}-weighted and inversion recovery sequences). Results: Irradiation of Fe{sup 3+} reduction dosimeters resulted in a stable red color with an absorbance peak at 512 nm. The change in OD relative to dose exhibited a linear response up to 100 Gy (R{sup 2}=1.00). T{sub 1}-weighted-MR signal intensity (SI) changed minimally after irradiation with increases of 8.0% for 17 Gy and 9.7% after escalation to 35 Gy compared to the un-irradiated region. Irradiation of Fe{sup 2+} oxidation dosimeters resulted in a stable purple color with absorbance peaks at 440 and 585 nm. The changes in OD, T{sub 1}-weighted-MR SI, and R{sub 1} relative to dose exhibited a linear response up to at least 8 Gy (R{sup 2}=1.00, 0.98, and 0.99) with OD saturation above 40 Gy. The T{sub 1}-weighted-MR SI increased 50.3% for 17 Gy compared to the un-irradiated region. The change in SI was observed in both 2D+time and 4D (3D+time) acquisitions post-irradiation and in real-time during irradiation with a linear increase with respect to dose (R{sup 2}>0.93). Conclusion: The Fe{sup 2+} oxidation-based system was superior as 4D dosimeters for MR-guided radiation therapy due to its higher sensitivity in both optical and MR signal readout and feasibility for real-time 4D dose readout. The Fe{sup 3+} reduction system is recommended for high dose applications. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship Program under Grant No. LH-102SPS.

60 APPLIED LIFE SCIENCES↗

Should regional ventilation function be considered during radiation treatment planning to prevent radiation-induced complications?

Purpose: To investigate the incorporation of pretherapy regional ventilation function in predicting radiation fibrosis (RF) in stage III nonsmall cell lung cancer (NSCLC) patients treated with concurrent thoracic chemoradiotherapy. Methods: Thirty-seven patients with stage III NSCLC were retrospectively studied. Patients received one cycle of cisplatin–gemcitabine, followed by two to three cycles of cisplatin–etoposide concurrently with involved-field thoracic radiotherapy (46–66 Gy; 2 Gy/fraction). Pretherapy regional ventilation images of the lung were derived from 4D computed tomography via a density change–based algorithm with mass correction. In addition to the conventional dose–volume metrics (V{sub 20}, V{sub 30}, V{sub 40}, and mean lung dose), dose–function metrics (fV{sub 20}, fV{sub 30}, fV{sub 40}, and functional mean lung dose) were generated by combining regional ventilation and radiation dose. A new class of metrics was derived and referred to as dose–subvolume metrics (sV{sub 20}, sV{sub 30}, sV{sub 40}, and subvolume mean lung dose); these were defined as the conventional dose–volume metrics computed on the functional lung. Area under the receiver operating characteristic curve (AUC) values and logistic regression analyses were used to evaluate these metrics in predicting hallmark characteristics of RF (lung consolidation, volume loss, and airway dilation). Results: AUC values for the dose–volume metrics in predicting lung consolidation, volume loss, and airway dilation were 0.65–0.69, 0.57–0.70, and 0.69–0.76, respectively. The respective ranges for dose–function metrics were 0.63–0.66, 0.61–0.71, and 0.72–0.80 and for dose–subvolume metrics were 0.50–0.65, 0.65–0.75, and 0.73–0.85. Using an AUC value = 0.70 as cutoff value suggested that at least one of each type of metrics (dose–volume, dose–function, dose–subvolume) was predictive for volume loss and airway dilation, whereas lung consolidation cannot be accurately predicted by any of the metrics. Logistic regression analyses showed that dose–function and dose–subvolume metrics were significant (P values ≤ 0.02) in predicting volume airway dilation. Likelihood ratio test showed that when combining dose–function and/or dose–subvolume metrics with dose–volume metrics, the achieved improvements of prediction accuracy on volume loss and airway dilation were significant (P values ≤ 0.04). Conclusions: The authors’ results demonstrated that the inclusion of regional ventilation function improved accuracy in predicting RF. In particular, dose–subvolume metrics provided a promising method for preventing radiation-induced pulmonary complications.

60 APPLIED LIFE SCIENCES↗

Behavioral consequences of radiation exposure to simulated space radiation in the C57BL/6 mouse: open field, rotorod, and acoustic startle

Two experiments were carried out to investigate the consequences of exposure to proton radiation, such as might occur for astronauts during space flight. C57BL/6 mice were exposed, either with or without 15-g/cm2 aluminum shielding, to 0-, 3-, or 4-Gy proton irradiation mimicking features of a solar particle event. Irradiation produced transient direct deficits in open-field exploratory behavior and acoustic startle habituation. Rotorod performance at 18 rpm was impaired by exposure to proton radiation and was impaired at 26 rpm, but only for mice irradiated with shielding and at the 4-Gy dose. Long-term (>2 weeks) indirect deficits in open-field activity appeared as a result of impaired experiential encoding immediately following exposure. A 2-week recovery prior to testing decreased most of the direct effects of exposure, with only rotorod performance at 26 rpm being impaired. These results suggest that the performance deficits may have been mediated by radiation damage to hippocampal, cerebellar, and possibly, forebrain dopaminergic function.

Non-NASA Center↗

Coupling of Dust Mineralogy to Radiation in NASA GISS ModelE: Impact Upon Dust Optical Properties and Direct Radiative Effect

Estimates of dust direct radiative effect (DRE) are still largely uncertain mainly due to the poor constraining of regional variations of dust absorption, whose known connection with mineral composition is still largely neglected by most Earth System Models. The inaccurate knowledge of soil mineralogy and insufficient measurements of dust physical and optical properties still present the main challenges for a proper representation of the dust-radiation interaction in climate models. We recently upgraded the coupling of dust minerals to shortwave radiation in the NASA GISS ModelE. In particular, we extended the interaction to online-calculated minerals and implemented two different mixing configurations: i) external mixing of three main mineral components and ii) internal mixing of all minerals, allowing a dynamic fraction of iron oxides. We used a semi-empirical approach for the optical calculations, mostly based on aerosol chamber measurements from natural soils, aiming to reduce the influence of uncertain assumptions on the optical properties and mixing state of individual minerals. In this contribution, we present the results of our first calculations of dust optical properties and DREs based on different mixing configurations of interactive minerals. We show the changes to dust optical depth and single scattering albedo, with respect to the control case using homogeneous dust composition, and the consequent global and regional variations in dust DREs at the top of atmosphere and at surface. We also compare the model optical properties with AERONET data, filtered to identify dust scenes. We find that accounting for the diverse properties of dust minerals modifies the pattern of regional dust absorption and therefore its impact upon climate. We also show that the mineralogy effect is sensitive to the assumed mixing state of minerals.

dust direct radiative effect↗

A GeoNEX-Based High-Spatiotemporal-Resolution Product of Land Surface Downward Shortwave Radiation and Photosynthetically Active Radiation

Surface downward shortwave radiation (DSR) and photosynthetically active radiation (PAR) play critical roles in the Earth’s surface processes. As the main inputs of various ecological, hydrological, carbon, and solar photovoltaic models, increasing requirements for high-spatiotemporal-resolution DSR and PAR es- timation with high accuracy have been observed in recent years. However, few existing products satisfy all of these requirements. This study employed a well-established physical-based lookup table (LUT) approach to the GeoNEX gridded top-of-atmosphere bidirectional reflectance factor data acquired by the Advanced Hi- mawari Imager (AHI) and Advanced Baseline Imager (ABI) sensors. It produced a data product of DSR and PAR over both AHI and ABI coverage at an hourly temporal step with a 1 km spatial resolution. GeoNEX DSR data were validated over 63 stations, and GeoNEX PAR data were validated over 27 stations. The vali- dation showed that the new GeoNEX DSR and PAR products have accuracy higher than other existing prod- ucts, with root mean square error (RMSE) of hourly GeoNEX DSR achieving 74.3Wm−2 (18.0%), daily DSR estimation achieving 18.0 W m−2 (9.2 %), hourly GeoNEX PAR achieving 34.9 W m−2 (19.6 %), and daily PAR achieving 9.5 W m−2 (10.5 %). The study also demonstrated the application of the high-spatiotemporal- resolution GeoNEX DSR product in investigating the spatial heterogeneity and temporal variability of surface solar radiation. The data product can be freely accessed through the NASA Advanced Supercomputing Division GeoNEX data portal: https://data.nas.nasa.gov/geonex/geonexdata/GOES16/GEONEX-L2/DSR-PAR/ (last ac- cess: 12 March 2023) and https://data.nas.nasa.gov/geonex/geonexdata/HIMAWARI8/GEONEX-L2/DSR-PAR/ (last access: 12 March 2023) (https://doi.org/10.5281/zenodo.7023863; Wang and Li, 2022).

Surface downward shortwave radiation (DSR)↗

Low Dose Radiation Response Curves, Networks and Pathways in Human Lymphoblastoid Cells Exposed from 1 to 10 cGy of Acute Gamma Radiation

We investigated the low dose dependency of the transcriptional response of human cells to characterize the shape and biological functions associated with the dose response curve and to identify common and conserved functions of low dose expressed genes across cells and tissues. Human lymphoblastoid (HL) cells from two unrelated individuals were exposed to graded doses of radiation spanning the range of 1-10 cGy were analyzed by transcriptome profiling, qPCR and bioinformatics, in comparison to sham irradiated samples. A set of {approx}80 genes showed consistent responses in both cell lines; these genes were associated with homeostasis mechanisms (e.g., membrane signaling, molecule transport), subcellular locations (e.g., Golgi, and endoplasmic reticulum), and involved diverse signal transduction pathways. The majority of radiation-modulated genes had plateau-like responses across 1-10 cGy, some with suggestive evidence that transcription was modulated at doses below 1 cGy. MYC, FOS and TP53 were the major network nodes of the low-dose response in HL cells. Comparison our low dose expression findings in HL cells with those of prior studies in mouse brain after whole body exposure, in human keratinocyte cultures, and in endothelial cells cultures, indicates that certain components of the low dose radiation response are broadly conserved across cell types and tissues, independent of proliferation status.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of discrete {gamma} radiation in interactions of 14.9-MeV neutrons with natural silicon by a total {gamma}-radiation measurement technique

The discrete {gamma} radiation in the interaction of 14.9-MeV neutrons and a natural silicon sample is investigated with a total {gamma}-radiation measurement (TGRM) technique. Fifty prompt {gamma} lines, one delayed {gamma} line, and seven final nuclei are identified. Forty-one possible transitions are designated. Differential production cross sections of 40 {gamma} lines at 40 deg., 55 deg., 90 deg., 125 deg., and 140 deg. are determined. Using relative differential production cross sections, accurate integral isotopic cross sections of the {sup 28}Si(n,p){sup 28}Al reaction are determined, and partial integral isotopic cross sections of the {sup 28}Si(n,n'){sup 28}Si, {sup 28}Si(n,{alpha}){sup 25}Mg, {sup 29}Si(n,n'){sup 29}Si, and {sup 30}Si(n,n'){sup 30}Si reaction channels are also estimated. The present results are in good agreement with some recent experimental and evaluated results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electroweak radiative corrections for polarized Moller scattering at the future 11 GeV JLab experiment

We perform updated and detailed calculations of the complete NLO set of electroweak radiative corrections to parity violating e – e – → e – e – (γ) scattering asymmetries at energies relevant for the ultra-precise Moller experiment coming soon at JLab. Our numerical results are presented for a range of experimental cuts and relative importance of various contributions is analyzed. In addition, we also provide very compact expressions analytically free from non-physical parameters and show them to be valid for fast yet accurate estimations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for charmonium and charmoniumlike states in Υ ( 2 S ) radiative decays

Using a sample of 158 x 10⁶ Υ(2S) events collected with the Belle detector, charmonium and charmoniumlike states with even charge parity are searched for in Υ(2S) radiative decays. No significant Xcl or nc signal is observed, and the following upper limits at 90% confidence level (C. L.) are obtained: Β(Υ(2S)→YXco)<1.0×10 - ⁴, Β(Υ(2S)→yxc1)<3.6×10 - ⁶, Β(Υ(2S)→yxc2)<1.5 x 10 - ⁵, and Β(Υ(2S)→ync)<2.7×10 - ⁵. No significant signal of any charmoniumlike state is observed, and we obtain the limits Β(Υ(2S)→yX(3872)) x Β(X(3872)→π⁺π⁻J/ψ)<0.8×10-6, Β(Υ(2S)→γX(3872))× Β(X(3872)→ π⁺π⁻π⁰Jlψ)<2.4 x 10⁻⁶, Β(Υ(2S)→γX(3915))× Β(X(3915)→ωJ/ψ)<2.8×10⁻⁶, Β(Υ(2S)→γY(4140)) x Β(Y(4140)→$\phi$J/ψ))<1.2 x 10 - ⁶, and Β(Υ(2S)→yX(4350))× Β(X(4350)→$\phi$J/ψ))<1.3×10⁻⁶ at 90% C. L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Zone Plate Properties using Monochromatic Synchrotron Radiation in the 2 to 20 nm Wavelength Range

A zone plate composed of Mo zones having 4 mm outermost zone diameter, 100 nm outermost zone width, and supported on a silicon nitride membrane was characterized using monochromatic synchrotron radiation in the 2 to 20 nm wavelength range. The zero and first order efficiencies were measured and compared to ab initio calculations that account for the optical properties of the materials, the width and shape of the zones, and multiple-layer thin-film effects. It is shown that the thicknesses of the Mo zones and the membrane and the ratio of the zone width to zone period can be independently determined from the measured diffraction efficiencies in the zero and first orders and that the computational code can be used to reliably design zone plates that are optimized for applications such as solar irradiance monitors in the extreme ultraviolet region.

36 MATERIALS SCIENCE↗

Long-Term Results of Concomitant Boost Radiation Plus Concurrent Cisplatin for Advanced Head and Neck Carcinomas: A Phase II Trial of the Radiation Therapy Oncology Group (RTOG 99-14)

Purpose: The feasibility of combining concomitant boost-accelerated radiation regimen (AFX-C) with cisplatin was previously demonstrated in this Phase II trial. This article reports the long-term toxicity, relapse patterns, and survival in patients with advanced head and neck carcinoma. Methods and Materials: Between April and November 2000, 84 patients with Stage III-IV HNC were enrolled, and 76 patients were analyzable. Radiation consisted of 72 Gy over 6 weeks. Cisplatin dose was 100 mg/m{sup 2} on Days 1 and 22. Tumor and clinical status were assessed, and acute-late toxicities were graded. Results: The median follow-up for surviving patients is 4.3 years. The 2- and 4-year locoregional failure rates were 33% and 36%, respectively, and the 2- and 4-year survival rates were 70% and 54%, respectively. The worst overall late Grade 3 or 4 toxicity rate was 42%. The prevalence rates of a gastrostomy at any time during follow-up, at 12 months, and at 48 months were 83%, 41%, and 17%, respectively. Five of 36 patients (14%) alive and without disease at last follow-up were gastrostomy-tube dependent. Conclusion: These data of long-term follow-up of patients treated with AFX-C with cisplatin show encouraging results with regard to locoregional disease control and survival, with few recurrences after 2 years. The late toxicity rates are relatively high. However, although prolonged dysphagia was noted in our preliminary report, its prevalence does decreased over time. A Phase III trial comparing AFX-C plus cisplatin against standard radiation plus cisplatin has completed accrual.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Induction and Concurrent Taxanes Enhance Both the Pulmonary Metabolic Radiation Response and the Radiation Pneumonitis Response in Patients With Esophagus Cancer

Purpose: The primary aim of this study was to assess pulmonary radiation toxicity quantitatively in patients who received thoracic radiotherapy combined with induction and/or concurrent chemotherapy with or without taxanes for esophageal cancer. Methods and Materials: The study subjects were 139 patients treated at the University of Texas M.D. Anderson Cancer Center for esophageal cancer and who had undergone [{sup 18}F]-fluorodeoxyglucose positron emission tomography/computed tomography between November 1, 2003 and December 15, 2007 for disease restaging after chemoradiotherapy. The patients were grouped into those who had not received taxanes (Group 1), those who had received induction or concurrent taxanes (Group 2), and those who had received both induction and concurrent taxanes (Group 3). Clinical pulmonary toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. Linear regression was applied to the fluorodeoxyglucose uptake vs. radiation dose to determine the pulmonary metabolic radiation response (PMRR) for each case. The clinical toxicity scores and PMRR among the groups were evaluated for significance differences. Results: The crude rate of pneumonitis symptoms was 46%, 62%, and 74% for Group 1, 2, and 3, respectively. The analysis of variance test of log(PMRR) by treatment was significant (p = .0046). Group 3 had a 61% greater PMRR compared with Group 1 (p = .002). Group 2 had a 38% greater PMRR compared with Group 1 (p = .015). Finally, Group 3 had a 17% greater PMRR compared with Group 2 (p = .31). A PMRR enhancement ratio of 1.60 (95% confidence interval, 1.19-2.14) was observed for Group 3 vs. Group 1. Conclusion: Patients given induction and concurrent taxane chemotherapy had a significantly greater PMRR and clinical pneumonitis symptoms compared with the patients whose chemotherapy regimen did not include taxanes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lowering Whole-Body Radiation Doses in Pediatric Intensity-Modulated Radiotherapy Through the Use of Unflattened Photon Beams;Flattening filter; Pediatric; Intensity-modulated radiotherapy; Second cancers; Radiation-induced malignancies

Purpose: Intensity modulated radiotherapy (IMRT) has been linked with an increased risk of secondary cancer induction due to the extra leakage radiation associated with delivery of these techniques. Removal of the flattening filter offers a simple way of reducing head leakage, and it may be possible to generate equivalent IMRT plans and to deliver these on a standard linear accelerator operating in unflattened mode. Methods and Materials: An Elekta Precise linear accelerator has been commissioned to operate in both conventional and unflattened modes (energy matched at 6 MV) and a direct comparison made between the treatment planning and delivery of pediatric intracranial treatments using both approaches. These plans have been evaluated and delivered to an anthropomorphic phantom. Results: Plans generated in unflattened mode are clinically identical to those for conventional IMRT but can be delivered with greatly reduced leakage radiation. Measurements in an anthropomorphic phantom at clinically relevant positions including the thyroid, lung, ovaries, and testes show an average reduction in peripheral doses of 23.7%, 29.9%, 64.9%, and 70.0%, respectively, for identical plan delivery compared to conventional IMRT. Conclusions: IMRT delivery in unflattened mode removes an unwanted and unnecessary source of scatter from the treatment head and lowers leakage doses by up to 70%, thereby reducing the risk of radiation-induced second cancers. Removal of the flattening filter is recommended for IMRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Rib Fractures After Hypofractionated Stereotactic Body Radiation Therapy: Risk Factors and Dose-Volume Relationship

Purpose: The purpose of this study was to clarify the incidence, the clinical risk factors, and the dose-volume relationship of radiation-induced rib fracture (RIRF) after hypofractionated stereotactic body radiation therapy (SBRT). Methods and Materials: One hundred sixteen patients treated with SBRT for primary or metastatic lung cancer at our institution, with at least 6 months of follow-up and no previous overlapping radiation exposure, were included in this study. To determine the clinical risk factors associated with RIRF, correlations between the incidence of RIRF and the variables, including age, sex, diagnosis, gross tumor volume diameter, rib-tumor distance, and use of steroid administration, were analyzed. Dose-volume histogram analysis was also conducted. Regarding the maximum dose, V10, V20, V30, and V40 of the rib, and the incidences of RIRF were compared between the two groups divided by the cutoff value determined by the receiver operating characteristic curves. Results: One hundred sixteen patients and 374 ribs met the inclusion criteria. Among the 116 patients, 28 patients (46 ribs) experienced RIRF. The estimated incidence of rib fracture was 37.7% at 3 years. Limited distance from the rib to the tumor (<2.0 cm) was the only significant risk factor for RIRF (p = 0.0001). Among the dosimetric parameters used for receiver operating characteristic analysis, the maximum dose showed the highest area under the curve. The 3-year estimated risk of RIRF and the determined cutoff value were 45.8% vs. 1.4% (maximum dose, {>=}42.4 Gy or less), 51.6% vs. 2.0% (V40, {>=}0.29 cm{sup 3} or less), 45.8% vs. 2.2% (V30, {>=}1.35 cm{sup 3} or less), 42.0% vs. 8.5% (V20, {>=}3.62 cm{sup 3} or less), or 25.9% vs. 10.5% (V10, {>=}5.03 cm{sup 3} or less). Conclusions: The incidence of RIRF after hypofractionated SBRT is relatively high. The maximum dose and high-dose volume are strongly correlated with RIRF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential for Improved Intelligence Quotient Using Volumetric Modulated Arc Therapy Compared With Conventional 3-Dimensional Conformal Radiation for Whole-Ventricular Radiation in Children

Purpose: To compare volumetric modulated arc therapy (VMAT) with 3-dimensional conformal radiation therapy (3D-CRT) in the treatment of localized intracranial germinoma. We modeled the effect of the dosimetric differences on intelligence quotient (IQ). Method and Materials: Ten children with intracranial germinomas were used for planning. The prescription doses were 23.4 Gy to the ventricles followed by 21.6 Gy to the tumor located in the pineal region. For each child, a 3D-CRT and full arc VMAT was generated. Coverage of the target was assessed by computing a conformity index and heterogeneity index. We also generated VMAT plans with explicit temporal lobe sparing and with smaller ventricular margin expansions. Mean dose to the temporal lobe was used to estimate IQ 5 years after completion of radiation, using a patient age of 10 years. Results: Compared with the 3D-CRT plan, VMAT improved conformality (conformity index 1.10 vs 1.85), with slightly higher heterogeneity (heterogeneity index 1.09 vs 1.06). The averaged mean doses for left and right temporal lobes were 31.3 and 31.7 Gy, respectively, for VMAT plans and 37.7 and 37.6 Gy for 3D-CRT plans. This difference in mean temporal lobe dose resulted in an estimated IQ difference of 3.1 points at 5 years after radiation therapy. When the temporal lobes were explicitly included in the VMAT optimization, the mean temporal lobe dose was reduced 5.6-5.7 Gy, resulting in an estimated IQ difference of an additional 3 points. Reducing the ventricular margin from 1.5 cm to 0.5 cm decreased mean temporal lobe dose 11.4-13.1 Gy, corresponding to an estimated increase in IQ of 7 points. Conclusion: For treatment of children with intracranial pure germinomas, VMAT compared with 3D-CRT provides increased conformality and reduces doses to normal tissue. This may result in improvements in IQ in these children.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase II Study of Intensity Modulated Radiation Therapy to the Pelvis for Postoperative Patients With Endometrial Carcinoma: Radiation Therapy Oncology Group Trial 0418

Purpose: To determine the feasibility of pelvic intensity modulated radiation therapy (IMRT) for patients with endometrial cancer in a multi-institutional setting and to determine whether this treatment is associated with fewer short-term bowel adverse events than standard radiation therapy. Methods: Patients with adenocarcinoma of the endometrium treated with pelvic radiation therapy alone were eligible. Guidelines for target definition and delineation, dose prescription, and dose-volume constraints for the targets and critical normal structures were detailed in the study protocol and a web-based atlas. Results: Fifty-eight patients were accrued by 25 institutions; 43 were eligible for analysis. Forty-two patients (98%) had an acceptable IMRT plan; 1 had an unacceptable variation from the prescribed dose to the nodal planning target volume. The proportions of cases in which doses to critical normal structures exceeded protocol criteria were as follows: bladder, 67%; rectum, 76%; bowel, 17%; and femoral heads, 33%. Twelve patients (28%) developed grade {>=}2 short-term bowel adverse events. Conclusions: Pelvic IMRT for endometrial cancer is feasible across multiple institutions with use of a detailed protocol and centralized quality assurance (QA). For future trials, contouring of vaginal and nodal tissue will need continued monitoring with good QA and better definitions will be needed for organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗