Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining Astrometry and Elemental Abundances: The Case of the Candidate Pre-Gaia Halo Moving Groups G03-37, G18-39, and G21-22

While most moving groups are young and nearby, a small number have been identified in the Galactic halo. Understanding the origin and evolution of these groups is an important piece of reconstructing the formation history of the halo. Here we report on our analysis of three putative halo moving groups: G03-37, G18-39, and G21-22. Based on Gaia EDR3 data, the stars associated with each group show some scatter in velocity (e.g., Toomre diagram) and integrals of motion (energy, angular momentum) spaces, counter to expectations of moving-group stars. We choose the best candidate of the three groups, G21-22, for follow-up chemical analysis based on high-resolution spectroscopy of six presumptive members. Using a new Python code that uses a Bayesian method to self-consistently propagate uncertainties from stellar atmosphere solutions in calculating individual abundances and spectral synthesis, we derive the abundances of α- (Mg, Si, Ca, Ti), Fe-peak (Cr, Sc, Mn, Fe, Ni), odd-Z (Na, Al, V), and neutron-capture (Ba, Eu) elements for each star. We find that the G21-22 stars are not chemically homogeneous. Based on the kinematic analysis for all three groups and the chemical analysis for G21-22, we conclude the three are not genuine moving groups. The case for G21-22 demonstrates the benefit of combining kinematic and chemical information in identifying conatal populations when either alone may be insufficient. Comparing the integrals of motion and velocities of the six G21-22 stars with those of known structures in the halo, we tentatively associate them with the Gaia-Enceladus accretion event.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aerosol Inlets for a Mid-Sized Uncrewed Aerial System (UAS)

The purpose of this technical report is to document the efforts to design and test two inlet systems for aerosol sampling suitable for deployment on a medium-sized fixed-wing Uncrewed Aerial System (UAS). This work, which was supported by the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, was conducted at the Pacific Northwest National Laboratory (PNNL) for the ARM Aircraft Facility (AAF) starting in November 2017. The current work is a part of AAF efforts to instrument the ArcticShark (a mid-sized UAS owned and operated by the AAF) for atmospheric research and develop a scientific payload for deployment on a similar-sized UAS with minimal adaptation and integration. An aerosol inlet system is necessary to sample and transport ambient air sample to the scientific instrumentation with minimal distortions to the aerosols. Two isokinetic aerosol inlets were designed: the first is a simple passive system for a single instrument suitable to be installed in a wing pylon; the second is a system with active control designed to sample and distribute air among several heterogeneous instruments and to provide basic humidity control of the air sample so that the measured aerosol parameters should correspond to “dry” conditions (a common requirement). Both systems could be easily adapted for deployment on another platform and/or with a different set of instrumentation. Several conducted flight tests showed that the inlets’ performance met our design goals.

42 ENGINEERING↗

Intermediate-mass Early-type Disk Galaxies in the Virgo Cluster. II. Near-Infrared Spectra and Evidence for Differences in Evolution

We discuss near-infrared (NIR) slit spectra of six early-type disk galaxies in the Virgo Cluster that were examined previously at visible/red wavelengths. Despite having similar intrinsic luminosities, colors, and morphologies, the NIR spectrophotometric properties of these galaxies indicate that they are not a homogeneous ensemble differing only in terms of luminosity-weighted age and metallicity. While the depth of the CO(2,0) band is consistent with the centers of these galaxies having solar or slightly sub-solar luminosity-weighted metallicities, galaxy-to-galaxy variations in the depth of the Na i 2.21 μm doublet are found, with Na i2.21 μm lines in three galaxies (NGC 4491, NGC 4584, and NGC 4620) that are deeper than those predicted for a solar chemical mixture and a solar-neighborhood mass function. In contrast, the Ca i2.26 μm triplet shows good galaxy-to-galaxy agreement but tends to be deeper than the model prediction. Considering the depth of the NaD lines, the deep Na i2.21 μm lines are tentatively attributed to a bottom-heavy mass function. This is counter to observed trends between mass function slope and velocity dispersion, and so the possibility of a super-solar [Na/Fe] is also discussed. Two of the three galaxies with deep Na i 2.21 μm (NGC 4584 and NGC 4620) have Sérsic exponents that are consistent with a classical bulge. As for NGC 4491, its central NIR spectrum contains prominent emission lines. The relative strengths of Brγ and H{sub 2}S(1), the presence of [Fe ii] emission, and the mid-infrared spectral-energy distribution are all consistent with intense recent star formation near the center of that galaxy. The NIR spectrum of NGC 4584 is devoid of line emission in the NIR, suggesting that star formation does not power the emission detected at visible wavelengths from that galaxy. Wavelengths that contain the Ballick–Ramsey C{sub 2} band at 1.76 μm are matched by moderately metal-poor E-MILES model spectra with an age of 2 Gyr. The radial age trends in these galaxies are in the opposite sense to those in late-type disk galaxies, and it is concluded that they have evolved in a cluster environment for at least several Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Neutron Temporal Signatures for Uranium Enrichment Measurement NA-241 SGTech (Final Report)

Nondestructive determination of uranium enrichment is a core capability for nuclear material accounting and control (NMAC) and safeguards verification measurements; however, traditional gamma spectroscopy-based techniques for enrichment measurement rely on significant assumptions of material composition and geometry, precluding their use in scenarios where a heterogeneous spatial distribution of enrichments is encountered. As an alternative, we are developing a technique to use delayed neutron temporal signatures for the measurement of uranium enrichment. Each uranium isotope has unique delayed neutron group yields, resulting in a unique delayed neutron decay time profile which can be analyzed to determine enrichment without the need for calibration sources. As part of this effort, we performed a series of measurement campaigns in which we used an active well coincidence counter (AWCC) retrofitted with commercial D-D and D-T generators to evaluate the operational characteristics of this method in response to a set of uranium enrichment and mass standards, as well as representative diversion scenarios in which either “concealed” enriched uranium is shielded by depleted uranium or declared enriched uranium is “hollowed out” and replaced with a central region of depleted uranium. A standard operating procedure and best practices were compiled to facilitate the use of delayed neutron-based enrichment measurements for international safeguards inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for electron-neutrino transitions to sterile states in the BEST experiment

The Baksan Experiment on Sterile Transitions (BEST) probes the gallium anomaly and its possible connections to oscillations between active and sterile neutrinos. Based on the Gallium-Germanium Neutrino Telescope (GGNT) technology of the SAGE experiment, BEST employs two zones of liquid Ga target to explore neutrino oscillations on the meter scale. Oscillations on this short scale could produce deficits in the 71 Ge production rates within the two zones, as well as a possible rate difference between the zones. From July 5th to October 13th 2019, the two-zone target was exposed to a primarily monoenergetic, 3.4-MCi 51 Cr neutrino source 10 times for a total of 20 independent 71 Ge extractions from the two Ga targets. The 71 Ge production rates from the neutrino source were measured from July 2019 to March 2020. At the end of these measurements, the counters were filled with 71 Ge doped gas and calibrated during November 2020. In this paper, results from the BEST sterile neutrino oscillation experiment are presented in details. The ratio of the measured 71 Ge production rates to the predicted rates for the inner and the outer target volumes are calculated from the known neutrino capture cross section. Comparable deficits in the measured ratios relative to predicted values are found for both zones, with the 4⁢𝜎 deviations from unity consistent with the previously reported gallium anomaly. Finally, if interpreted in the context of neutrino oscillations, the deficits give best-fit oscillation parameters of Δ⁢𝑚 2 = 3.3$^{+∞}{−2.3}$ eV 2 and sin 2 ⁡2⁢𝜃 = 0.42$^{+0.15}{−0.17}$, consistent with 𝜈 𝑒 →𝜈 𝑠 oscillations governed by a surprisingly large mixing angle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wall effects observed in tissue-equivalent proportional counters from 1.05 GeV/nucleon iron-56 particles

Tissue-equivalent proportional counters (TEPCs) have been used to measure energy deposition in simulated volumes of tissue ranging in diameter from 0.1 to 10 microm. There has been some concern that the wall used to define the volume of interest could influence energy deposition within the sensitive volume because it has a density significantly greater than that of the cavity gas. These effects become important for high-velocity heavy ions. Measurements of energy deposition were made for 1 GeV/nucleon iron particles in a TEPC simulating a 1-microm-diameter sphere of tissue. The TEPC was nested within a particle spectrometer that provided identification and flight path of individual particles. Energy deposition was studied as a function of pathlength through the TEPC. Approximately 30% of the energy transfer along trajectories through the center of the detector escapes the sensitive volume. The response of the TEPC, for trajectories through the detector, is always larger than calculations for energy loss in a homogeneous medium. This enhancement is greatest for trajectories near the cavity/wall interface. An integration of the response indicates that charged-particle equilibrium is essentially achieved for a wall thickness of 2.54 mm. However, estimates of the linear energy transfer for the incident particles are influenced by these wall effects.

Non-NASA Center↗

Analysis of humidity sensitivity of silicon strip sensors for ATLAS upgrade tracker, pre- and post-irradiation

During the prototyping phase of the new ATLAS Inner-Tracker (ITk) strip sensors, a degradation of the device breakdown voltage at high humidity was observed. Although the degradation was temporary, showing a fast recovery in dry conditions, the study of the influence of humidity on the sensor performance was critical to establish counter-measures and handling protocols during production testing in order to ensure the proper performance of the upgraded detector. The work presented here has the objective to study for the first time the breakdown voltage deterioration in presence of ambient humidity of ATLAS ITk production-layout strip sensors with different surface properties, before and after proton, neutron and gamma irradiations. A study of the humidity sensitivity of miniature ATLAS ITk strip sensors, before and after proton irradiations, is also presented to compare the sensitivity of devices with different sizes. The sensors were also exposed for several days to high humidity with the aim to recreate and evaluate the influence of the detector integration environment expected during the Large Hadron Collider (LHC) Long Shutdown 3 (LS3) in 2026, where the sensors will be exposed to ambient humidity for prolonged times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Triaxiality and the nature of low-energy excitations in Ge 76

The deformation properties of the low-lying states in 76 Ge have been investigated following a safe energy Coulomb excitation measurement with the GRETINA tracking array and CHICO2 heavy-ion counter at the ATLAS accelerator facility at Argonne National Laboratory. A comprehensive set of transition and static E2 matrix elements were extracted from the measured differential Coulomb cross-sections, and compared with results of configuration interaction shell-model calculations and computations carried out within the framework of the generalized triaxial rotor model. The remarkable agreement between the calculated and experimental data supports a near-maximum triaxial deformation for the ground state of 76 Ge. Additionally, the degree of softness of the asymmetry in 76 Ge and 76 Se was investigated using rotational invariants generated from configuration interaction shell-model wave functions computed with the jj44b and JUN45 effective interactions. The resulting invariants are shown to be consistent with a stiff triaxial deformation in 76 Ge and a predominantly soft triaxial potential for 76 Se, in agreement with the conclusions of recent works by this collaboration.

59 ≤ A ≤ 89↗

Design and Development of a Robotic Exoskeleton Device for use in Glove Boxes - 20374

Glovebox operators in nuclear facilities often operate under radioactive environment and typically perform monotonous, dull and repetitive work. This can result in muscle fatigue leading to increased levels of accidents. Current research work aims in assisting the glovebox operators by designing a novel upper limb exoskeleton device to reduce injuries and increase worker efficiency. Almost none of the commercially available hand and upper body exoskeletons are directly suitable for use in gloveboxes. This explains the novelty of the present work in developing a wearable powered robotic exoskeleton device. The device consists of electronics, motors and spring systems mounted on adjustable plates and is supported by a stationary frame behind the worker. The device is intended to be portable and adjustable according to the operator height. The elbow has a flexion movement assisted with motor control by way of a Bowden cable system. The system is floated on a spring and pulley combination that allows for extra safety and smoothness of operation. The end points are fixed near the pivot points to help minimize unwanted movement/torque. The extension movement of the upper and lower arm are assisted by gravity and a counter spring. The shoulder and upper arm movement are held in a neutral position with a spring system for counter balance allowing small movements within the glovebox. This initial concept considers only the vertical movement of the arm. The abduction and adduction movement will not be assisted or impeded by the over shoulder plate or at the forearm plate allowing for full range of motion. Several glovebox aspects such as the level of task assistance, ergonomic design, minimum hindrance in dexterity/operator movements and tear resistance for hazardous safety reasons will be considered in the design of the exoskeleton. Computer models will be simulated to test the load levels and stress conditions on the exoskeleton to enhance the designs. The exoskeleton focusses on major muscular involvement reduction through weight offset and active assistance with minimal parts and hence the device is derived with several joint links and contains both passive and active joints. The paper details the various stages in the design development and prototype testing of the exoskeleton device. Upon successful prototype device development, human testing will be conducted in a replica of the SRS-235F hot cell facility constructed at FIU-ARC. The final stage of the project will be potential testing/deployment of the exoskeleton device in one of the glovebox facilities in Savannah River Nuclear Waste site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charge trapping correction and energy performance of the Majorana Demonstrator

P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the Majorana Demonstrator, a neutrinoless double-β decay experiment deploying PPC detectors enriched in 76 Ge, has led to several novel improvements in the analysis of PPC signals. Here, in this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal, and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the Majorana Demonstrator by approximately 30 % to around 2.4 keV full width at half-maximum at 2039 keV, the 76 Ge Q value. An alternative approach achieving similar resolution enhancement is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CLAS12 High Threshold Cherenkov Counter

The High Threshold Cherenkov Counter (HTCC) is one of the detector systems of the CLAS12 spectrometer, and is used to generate a fast trigger signal in electron scattering experiments in the polar angle range from 5°to 35°. The HTCC is installed in front of the drift chambers and introduces a minimal amount of additional material within the acceptance. The HTCC is one unit whose core component is a multifocal mirror that consists of 60 lightweight ellipsoidal mirrors. It is important that the HTCC provides efficient coverage of the CLAS12 forward acceptance with no gaps. In order to achieve this, each sector of the CLAS12 Forward Detector is covered by 2 identical half-sector mirrors that focus Cherenkov light on 8 phototubes. The HTCC has a total of 48 channels with Electron Tubes 9823QKB photomultipliers that have a 5-in quartz face plate to detect Cherenkov light. The system provides rejection of charged -mesons with momenta below 4.8 GeV for the reliable identification of scattered electrons. In this paper the details of the design, construction, calibration, and performance results of the HTCC are presented

Sharabian, Y. G.↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of 10 B to convert epithermal neutrons into detectable α and 7 Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 μm boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV–500 keV epithermal energy range. For a 10 cm 2 active area, the detector achieves sensitivity to H 2 O weight fractions as low as 0.01 wt% in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

Detector modelling and simulations I (interaction ↗