Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Investigation of Materials for Radio Frequency Antenna Plasma Facing Components

Here, the interaction of radio frequency (RF) sheaths with fusion reactor relevant materials (e.g., tungsten and titanium diboride) is being studied on the RF Plasma Interaction Experiment (RF PIE). The RF PIE consists of an electron cyclotron resonance (ECR) plasma source (2.45 GHz, 5 kW) with a biased and heated RF electrode that is used to simulate antenna surfaces in contact with the edge plasma. Helium plasmas (density of ~1e18/m 3 , electron temperature of 4–5 eV) are being used to explore sheath formation on material surfaces with biases up to 500 V. The erosion of a tungsten surface is being studied spectroscopically using a mirror-linked 1 m Czerny-Turner UV imaging spectrometer with a spectral resolution of 0.012 nm for measuring plasma emission in and near the sheath. Tungsten line emission intensity is higher for RF versus dc biasing for similar plasma conditions and average ion energy. RF biasing causes a broadening of the ion energy distribution function (IEDF) due to the RF sheath, as determined from the hPIC2 code, and results in enhanced sputtering. Calculations of the expected sputtering yield for dc and RF biasing are consistent with experimental observations of changes in the 400.9 nm tungsten line emission intensity as a function of ion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of High-efficiency and Cost-effective Forged Ingot Niobium Technology for Science Frontiers and Accelerator Applications

Development of Forged Ingot Niobium Technology: Worlds science frontier programs and SRF accelerator applications demand high performance and cost-effective SRF accelerator technology [1-8]. Fine-grain (FG) and Large-grain (LG) ingot niobium technologies have been very well developed and implemented in all the present-day accelerator projects. However, forged ingot niobium technology which is the focus of this development proposal will be much more cost-effective and expected to have several technical advantages. FG niobium sheet production is very complex involving more than ten processing steps making them prone to contamination. As a result, they are very expensive to produce and require stringent QA procedure to be ready for SRF cavity production. The accelerating cavity process steps are also numerous and require strict procedures in order to achieve high accelerating gradients and quality factors needed for science frontier programs. LG niobium disc production, directly sliced from the ingot, is relatively simple and straight forward to keep surface cleanness. The disc production cost is significantly low compared to FG niobium sheet production. However, there are (some) draw backs due to non-homogeneity of the grain boundary distribution, resulting in non-uniform mechanical properties and complex cavity fabrication, although the LG cavities achieve the expected high-gradient performance goals with lower cost. Medium-grain (MG) niobium disk production may be realized with a new approach/process, the disc directly sliced from the forged ingot, involves a simpler process steps contributing major production cost reduction [9]. These discs are expected to be superior as they tend to be homogenous with uniform sub millimeter grains and mechanical properties. We are eagerly looking forward to developing the forged ingot niobium SRF accelerator technology for the benefit of the world-wide science frontier programs, green energy subcritical nuclear energy systems and a wide variety of industrial applications including the production of radio isotopes and nuclear transmutation applications. Measurement of thermal characteristics of the forged ingot niobium: Measurement of the thermal diffusivity, D, of superconducting MG niobium is important to be understood in comparison with FG sheet and LG disc, as well as that of advanced composite material of Nb3Sn film sputtered on forged ingot Nb, which will be determined using transient pump-probe thermo-modulation [10,11]. Transient thermo-modulation is based on using an ultrafast laser pulse to heat the superconducting materials by a few K, then a synchronized laser pulse probes the reflectance of the heated material. For thin films on a substrate (e.g, 100-nm Nb3Sn on Nb), it takes <100 ps for the heat to reach the substrate by diffusion. Therefore, an ultrafast method is needed to probe D of the studied material. D will be measured from room temperature to liquid helium temperatures. Fundamental Research: The increase of rf loss in SRF cavities is related to trapping of residual magnetic field during the cavity cool-down. The study suggested that the micro structure plays the role in flux trapping sensitivity. The research includes the flux trapping and expulsion study as forged ingot niobium goes through several mechanical deformations, crystallization leading to the optimal SRF cavity performance. Furthermore, the cavity made from FG, MG, and LG sheet/disc will be compared to understand the optimal re-crystallization temperature that cavity needed to be heat treated which minimize the flux trapping and increase SRF cavity performance. References: 1. S. Belomestnykh, Overview of recent SRF developments for ERLs, presented at the SRF 2015, Whistler, BC, Canada (2015). 2. A. Yamamoto, M. Yamanaka and G. Myneni, Ingot Nb based SRF Technology for the International Linear Collider, in Science and Technology of Ingot Niobium for Superconducting Radio Frequency Applications, AIP Conf. Proc. 1687, 030005-1 ? 03005-6, 2015 3. Report of the Workshop on Energy and Environmental Applications of Accelerators, DOE Workshop Report. https://science.osti.gov/-/media/hep/pdf/Reports/2020/CASM_WorkshopReport.pdf? la=en&hash=AEB0B318ED0436B1C5FF4EE0FDD6DEB84C2F15B2 4. G. Ciovati, et al., Design of a cw, low-energy, high-power superconducting linac for environmental applications, Phys. Rev. Accel. Beams 21, 091601 (2018). 5. P. Dhakal, et al., Effect of high temperature heat treatments on the quality factor of a large-grain superconducting radio-frequency niobium cavity, Phys. Rev. ST Accel. Beams 16, 042001 (2013). 6. P. Kneisel et al., Review of ingot niobium as a material for superconducting radio frequency accelerating cavities, Nuclear Instruments and Methods in Physics Research A 774, 133 (2015). 7. G. Ciovati, P. Dhakal, and G. R, Myneni, Superconducting radio-frequency cavities made from medium and low-purity niobium ingots, Supercond. Sci. Technol. 29, 064002 (2016). 8. M. Drury et al., commissioning of the prototype C75 cavities in a CEBAF cryomodule, in Proc. of IPAC 2018, Vancouver, BC, Canada (2018) 9. Feasibility of forged-ingot niobium disc and SRF cavity fabrication technology recently demonstrated in cooperation of ATI, BSCE, and KEK (2020). 10. Hani E. Elsayed-Ali, ?Measurements of heat transport in thin films by ultrafast laser-based techniques,? 3rd International Conference on Thermal Issues in Emerging Technologies Theory and Applications, Cairo, Egypt, pp. 347 ? 350 (2010). DOI: 10.1109/ThETA17616.2010 11. W. M. G. Ibrahim, H. E. Elsayed-Ali, M. Schinn, and C. A. Bonner, Jr., ?Ultrafast investigation of electron dynamics in multilayer metals,? Int. J. Heat and Mass Transfer, 47(10?11), 2261?2268 (2004).

Myneni, G.↗

Probe Station Antenna Range

This summer I was given the task of programming a Probe Station to collect near field antenna patterns and convert them to far field patterns. The purpose of this project is to provide NASA with another means of antenna characterizing. Currently, NASA Glenn can measure near field and far field patterns of many different types of antennas. The antennas targeted for this lab are small patch antennas at high frequencies that require probe biasing. The Probe Station contains two probes for RF signals and another two for DC Biasing. The way this lab works is as follows: A patch antenna is placed on the probe station and biased properly for testing. This antenna is known as the Antenna Under Test (AUT). The AUT is supplied with an RF signal from a probe that is connected to a network analyzer. Above the AUT hangs a probe for measuring the electric field emitted by the AUT. The probe is controlled by four axis. The axis of movements for this probe are back and forth, left and right, up and down, and rotation. The network analyzer and axis controllers are tied into a computer for reading commands and recording data. The probe scans a rectangular pattern above the AUT to measure the electric field emitted by the AUT. This data is then recorded and analyzed back at the computer.

Zaman, Afroz↗

Early performance of the 12-GHz, 200-watt transmitter experiment package in the communications technology satellite

Measured performance characteristics of the transmitter experiment package (TEP) aboard the Communications Technology Satellite for the first 90 operating days in orbit are presented. The TEP consists of a nominal 200-watt output stage tube (OST), a supporting power processing system (PPS), and a variable-conductance heat pipe system (VCHPS). The OST, a traveling-wave tube augmented with a 10-stage depressed collector, has an overall saturated average efficiency of 51.5 percent and an average saturated radiofrequency (RF) output power at center-band frequency of 240 watts. The PPS operated with a measured efficiency of 86.5 percent to 88.5 percent. The VCHPS, using three pipes to conduct heat from the PPS and the body of the OST to a 52-centimeter by 124-centimeter (20.5-in. by 48.75-in.) radiator fin, maintained by the PPS baseplate temperature below 50 C for all operating conditions. The TEP performance characteristics presented include frequency response, RF output power, efficiency, and distortions. Communications characteristics were evaluated by using both video and audio modulated signals.

Source record↗

High Average Power RF Window with Improved Multipactor Coating

Multipactor emission can be a serious issue for vacuum electron devices operating at megawatt power levels. It can lead to catastrophic failure from surface arcs or excessive heating of ceramic windows. Titanium nitride is effective at suppressing multipactor emission; however, sputter coating is not strongly bonded to surfaces and issue related to lifetime have arisen. It’s difficult to ensure a uniform coating over large surfaces. This research investigated atomic layer deposition (ALD) as an improved alternative to sputtered coatings. Test windows were fabricated and coated with TiN using ALD, then tested for RF loss and secondary emission. All ALD samples showed RF loss less than 0.01dB with secondary emission yield equal to or better than reported measurements with sputter coated windows. The program also designed a preliminary ALD system capable of coating windows up to 24 inches in diameter.

43 PARTICLE ACCELERATORS↗

Mass Spectrometric and Langmuir Probe Measurements in Inductively Coupled Plasmas in Ar, CHF3/Ar and CHF3/Ar/O2 Mixtures

Absolute fluxes and energy distributions of ions in inductively coupled plasmas of Ar, CHF3/Ar, and CHF3/Ar/O2 have been measured. These plasmas were generated in a Gaseous Electronics Conference (GEC) cell modified for inductive coupling at pressures 10-50 mTorr and 100-300 W of 13.56 MHz radio frequency (RF) power in various feedgas mixtures. In pure Ar plasmas, the Ar(+) flux increases linearly with pressure as well as RF-power. Total ion flux in CHF3 mixtures decreases with increase in pressure and also CHF3 concentration. Relative ion fluxes observed in the present studies are analyzed with the help of available cross sections for electron impact ionization and charge-exchange ion-molecule reactions. Measurements of plasma potential, electron and ion number densities, electron energy distribution function, and mean electron energy have also been made in the center of the plasma with a RF compensated Langmuir probe. Plasma potential values are compared with the mean ion energies determined from the measured ion energy distributions and are consistent. Electron temperature, plasma potential, and mean ion energy vary inversely with pressure, but increase with CHF3 content in the mixture.

Kim, J. S.↗

Investigations of high power problems in space shuttle antenna designs

A study program is discussed which includes a survey of industry and government laboratories and was undertaken to determine the state of the art in dealing with problems of high power levels in reentry antenna design. A laboratory program to develop techniques for testing dielectric materials for effects on RF transmission is also considered, with emphasis on high power applications in space and reentry flights. The study program resulted in a set of guidelines for avoiding breakdown in antenna design. A discussion of temperature effects on dielectric breakdown is also given. From the laboratory program, a description is presented of techniques for (1) heating with a carbon arc image furnace, (2) temperature measurement (using thermocouples and an infrared pyrometer), (3) mass spectrometric monitoring of outgassing, (4) testing for RF breakdown in both heated dielectrics and the dielectric/air and dielectric/plasma interfaces. Data and observations are reported from technique development using candidate shuttle materials falling into three categories: (1) lightweight refractory foams, (2) dense RF window materials, and (3) ablative materials.

Taylor, W. C.↗

A microwave SQUID multiplexer optimized for bolometric applications

A microwave SQUID (superconducting quantum interference device) has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/ $\sqrt{Hz}$, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design considerations for gallium arsenide pulse compression photoconductive switch

In this paper, we present the physics and design-space exploration of a novel pulse compression photoconductive switch (PCPS) using semi-insulating gallium arsenide (GaAs) operating in the negative differential mobility (NDM) regime of electron transport. We systematically quantify the relationship between the PCPS performance and various design options, including contact separation, laser energy and placement, and trap dynamics. Specifically, we report the full-width at half-maximum and the peak output current generated by the PCPS as a function of applied electrical and optical bias. We discuss the optimal spacing between the electrodes and the distance of the laser spot to the anode to achieve higher electron confinement and superior radio-frequency (RF) metrics. Reducing the laser energy is important to prevent the appearance of secondary peaks due to diffusive transport, but there exists a trade-off between the bandwidth and the maximum current of the PCPS. We also compare the PCPS response with and without trap dynamics and find that the electrostatic screening from the trap-induced space charge is time-independent when the trapping time constant is set larger than the recombination lifetime. Overall, trap dynamics are detrimental to performance, unless the compensation doping scheme to achieve semi-insulating GaAs is carefully selected. Results presented in this paper can be used by experimentalists to fine-tune the PCPS design parameters to meet the specifications of various RF applications. Moreover, our results will provide a strong theoretical basis to the measurements of PCPS devices using GaAs and other NDM materials under investigation.

42 ENGINEERING↗

Time-walk and jitter correction in SNSPDs at high count rates

Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion heating in the PISCES-RF liquid-cooled high-power, steady-state, helicon plasma device

Radio frequency (RF) driven helicon plasma sources are commonly used for their ability to produce high-density argon plasmas ( n > 10 19 m -3 ) at relatively moderate powers (typical RF power < 2 kW). Typical electron temperatures are <10 eV and typical ion temperatures are <0.6 eV. A newly designed helicon antenna assembly (with concentric, double-layered, fully liquid-cooled RF-transparent windows) operates in steady-state at RF powers up to 10 kW. We report on the dependence of argon plasma density, electron temperature and ion temperature on RF power. At 10 kW, ion temperatures >2 eV in argon plasmas are measured with laser induced fluorescence, which is consistent with a simple volume averaged 0D power balance model. 1D Monte Carlo simulations of the neutral density profile for these plasma conditions show strong neutral depletion near the core and predict neutral temperatures well above room temperatures. The plasmas created in this high-power helicon source (when light ions are employed) are ideally suited for fusion divertor plasma-material interaction studies and negative ion production for neutral beams.

Physics↗

Quantifying the Operational Impacts of Cyber Events on Enterprise Network Environments

The "Quantifying the Operational Impacts of Cyber Events on Enterprise Network Environments" Feasibility Study addressed the question: Can an existing (novel) class of network characterization and change detection algorithms previously developed at LLNL for internal enterprise datasets, be effectively applied to assess and measure the analytic value of features derived from datasets composed of passively collected RF and wireless network data?

97 MATHEMATICS AND COMPUTING↗

Characterization of dissipative regions of a N-doped superconducting radio-frequency cavity

We report radio-frequency measurements of quality factors and temperature mapping of a nitrogen doped Nb superconducting RF cavity. Cavity cutouts of hot and cold spots were studied with low temperature scanning tunneling microscopy and spectroscopy, X-ray photoelectron spectroscopy and secondary electron microscopy. Temperature mapping revealed a substantial reduction of the residual resistance upon cooling the cavity with a greater temperature gradient and hysteretic losses at the quench location, pointing to trapped vortices as the dominant source of residual surface resistance. Analysis of the tunneling spectra in the framework of a proximity effect theory shows that hot spots have a reduced pair potential and a wider distribution of the contact resistance between the Nb and the top Nb oxide. Alone, these degraded superconducting properties account for a much weaker excess dissipation as compared with the vortex contribution. Based on the correlation between the quasiparticle density of states and temperature mapping, we suggest that degraded superconducting properties may facilitate vortex nucleation or settling of trapped flux during cooling the cavity through the critical temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complex permittivity measurements during high temperature recycling of space shuttle antenna window and dielectric heat shield materials

The research performed and the data obtained on candidate space shuttle antenna window and heat shield materials are presented. The measurement technique employs a free-space focused beam microwave bridge for obtaining RF transmission data, and a device which rotates a sample holder which is heated on one side by natural gas-air flames. The surface temperature of each sample is monitored by IR pyrometry; embedded and rear surface thermocouples are also used in obtaining temperature data. The surface of the sample undergoing test is subjected to approximately the same temperature/time profile that occurs at a proposed antenna position on the space shuttle as it re-enters. The samples are cycled through ten of these temperature profiles to determine the recycling effects. Very little change was noted in the materials due to the recycling.

Bassett, H. L.↗

The effects of an ion-thruster exhaust plume on S-band carrier transmission

The magnitude of the effects of an ion thruster plume on S-band signals is measured. Modeling techniques are developed to predict the effects. Results show that the RF signal transmitted through an ion thruster plume is reduced in amplitude and shifted in phase. An increase in noise is also experienced.

Ackerknecht, W. E., III↗

Enhanced thermal emittance of space radiators by ion-discharge chamber texturing

The discharge chamber of a 30-cm argon ion source was successfully used to texture potential space radiator materials for the purpose of obtaining values of thermal emittance greater than 0.85 at 700 and 900 K. Some samples were also treated in acid prior to texturing. To evaluate the durability of the textured materials to atomic oxygen, samples were exposed to an RF air plasma environment. The spectral emittance between 2.0 anf 15.0 microns was measured before and after the textured materials were exposed to the plasma asher. The results indicate that copper with extremely high values of emittance after texturing (0.978 and 0.983) at 700 and 900 K, respectively,did not change its values of emittance after ashing, whereas the emittance of stainless steel fell below 0.85 after ashing. These data, along with scanning electron photomicrographs, and the results of texturing and ashing titanium and Nb(1)Zr are presented .

Mirtich, Michael J.↗

Bragg-cell receiver study

Bragg-cell receivers are employed in specialized Electronic Warfare (EW) applications for the measurement of frequency. Bragg-cell receiver characteristics are fully characterized for simple RF emitter signals. This receiver is early in its development cycle when compared to the IFM receiver. Functional mathematical models are derived and presented in this report for the Bragg-cell receiver. Theoretical analysis is presented and digital computer signal processing results are presented for the Bragg-cell receiver. Probability density function analysis are performed for output frequency. Probability density function distributions are observed to depart from assumed distributions for wideband and complex RF signals. This analysis is significant for high resolution and fine grain EW Bragg-cell receiver systems.

Wilson, Lonnie A.↗

Radio Frequency Survey of the 21-cm Wavelength(l.4 GHz) Allocation for Passive Microwave Observing

Because of the need to develop 1.4-GHz radiometers, a set of RF surveys was conducted in and around our laboratories. In this paper, a measurement campaign and analysis of radio frequency interference (RFI) in the 21 cm wavelength allocation for passive microwave observing, was undertaken. The experimental setup and measurement procedure are outlined and measured data are interpreted. Significant signals were discovered within and surrounding the allocated spectrum at 1.4 GHz. Some implications for remote sensing are discussed.

J R Piepmeier↗