Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Towards Scalable 3D Integration of 2T-nC FeRAM with Hundreds of Layer Stacking

In this article, we study the limits of the number of capacitors and read history dependence in a 2T-nC ferroelectric random-access memory (FeRAM) cell, paving the way for its high-density integration toward hundreds of stacked layers. Through a comprehensive experimental and simulation study on the scaling behavior of the 2T-nC FeRAM architecture, we demonstrate: (i) successful fabrication of 2T-64C cells with robust memory operation and clearly distinguishable ‘0’ and ‘1’ states, even in 64- capacitor configurations; (ii) that the parasitic capacitance of the floating node originates predominantly from the linear component of the ferroelectric capacitor, and its impact on n-scaling—due to degraded sense margin—can be mitigated by floating unselected capacitors with enough TΩ isolation; (iii) that sharing write and read transistors among n capacitors introduces a read history dependence issue due to fluctuating floating node voltage (VFN); and (iv) that a proposed FN discharge scheme can effectively eliminate read-sequence dependence, at the cost of reduced read endurance.

36 MATERIALS SCIENCE↗

SU-E-T-173: Evaluation of the MicroSTAR Reader for the OSLD System for Remote Dosimetry Audits at the IROC HQAC

Purpose: Analysis of the performance of the microSTARii reader for optically stimulated luminescence dosimeters (OSLD) used by the IROC Houston Quality Assurance Center (IROC HQAC) for external audits compare to the characteristics of the Microstar reader. Methods: The IROC HQAC uses the Microstar reader for the OSLD program for verification of output of photon, electron and proton beams. The calculation of dose from the OSLD system is based on a group of factors defined at time of the commissioning of a batch of detectors. Factors like system sensitivity (SS), depletion (KD), element correction factor (ECF), linearity (KL), energy correction (KE). The new microSTARii unit presents many hardware and software upgrades that were considered useful for this program. Based on these changes many factors, that were considered reader dependent, were revised in order to analyze the effect of the new reading process. The SS, KD, ECF and KL were evaluated and compared with data defined based on reading done on Microstar reader. Results: The SS is reader specific and specified at 100 cGy dose level. This value is define per reading session and monitored over time. The KD factor was found to be different because of reading procedure are different. The ECF values changed for a group of nano dots compare to values defined based on reading done on the Microstar reader. The KL was defined for the reader. Conclusion: The new microSTARii reader presents new features that improve the efficiency of the OSLD program at the IROC HQAC. New characterization is needed before final implementation is done to match the requirements of the existing OSLD system defined for the Microstar reader. Changes in uncertainty of the results has not been analized.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-222: Investigation of Pre and Post Irradiation Fading of the TLD100 Thermoluminescence Dosimetry for Photon Beams

Purpose: The pre-irradiation and post-irradiation fading of the Thermoluminescense dosimeter signals were investigated in this study. Methods: Two groups of TLD chips with pre-determined ECC values were used in this study. The two groups were divided into 6 series, each composing of 5 TLD chips.The first group was used for pre-irradiation fading. 5 TLDs were exposed to a known amount of radiation from Cs-137 source, and were read out the next day. After seven days, the other 5 TLDs were exposed to the same amount of radiation and were read out after a day. The other series of 5 TLDs were also exposed after 7,19,28, 59, and 90 days, and were read out a day after irradiation. The loss in TLD signal were obtained for all the above cases. The second group, was used for postirradiation fading. All the TLDs of this group were exposed to a known amount of radiation from Cs-137 source. The 6 series composed of 5 TLDs were read out after 1,7,19,28,59, and 90 days. The above-mentioned procedures for obtaining pre-irradiation, and post-irradiation fading were performed for three storage temperatures (25°C, 4°C, and −18°C). Results: According to the results obtained in this study, in case of pre-irradiation fading study, the signal losses after 90 days are 12%, 24%, and 17% for 25°C, 4°C, and −18°C respectively. In case of post-irradiation fading study, the sensitivity losses after 90 days are 25%, 216%, and 20% for 25°C, 4°C, and −18°C respectively. Conclusion: The results indicate that the optimized time between exposing and reading out, and also the optimized time between annealing and exposing is 1 day.The reduction of Storage temperature will reduce the post-irradiation fading, While temperature reduction does not have any effect on pre-irradiation fading.

60 APPLIED LIFE SCIENCES↗

TU-F-BRE-05: Experimental Determination of K Factor in Small Field Dosimetry

Purpose: Small-field dosimetry is challenging due to charged-particle disequilibrium, source occlusion and more importantly finite size of detectors. IAEA/AAPM has published approach to convert detector readings to dose by k factor. Manufacturers have been trying to provide various types of micro-detectors that could be used in small fields. However k factors depends on detector perturbations and are derived using Monte Carlo simulation. PTW has introduced a microDiamond for small-field dosimetry. An experimental approach is presented to derive the k factor for this detector. Methods: PTW microDiamond is a small volume detector with 1.1 mm radius and 1.0 micron thick synthetic diamond. Output factors were measured from 1×1cm2 to 12×12 cm2 on a Varian machine at various depths using various micro-detectors with published k factors. Dose is calculated as reading * K. Assuming k factor is accurate, output factor should be identical with every micro-detectors. Hence published k values (Francescon et al Med Phys 35, 504-513,2008) were used to covert readings and then output factors were computed. Based on the converged curve from other detectors, k factor for microDiamond was computed versus field size. Results: Traditional output factors as ratio of readings normalized to 10×10 cm2 differ significantly for micro-detectors for fields smaller than 3×3 cm2 which are now being used extensively. When readings are converted to dose, the output factor is independent of detector. Based on this method, k factor for microDiamond was estimated to be nearly constant 0.993±0.007 over varied field sizes. Conclusion: Our method provides a unique opportunity to determine the k factor for any unknown detector. It is shown that even though k factor depends on machine type due to focal spot, however for fields ≥1×1 cm2 this method provides accurate evaluation of k factor. Additionally microDiamond could be used with assumption that k factor is nearly unity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-CD-BRA-03: Direct Measurement of Magnetic Field Correction Factors, KQB, for Application in Future Codes of Practice for Reference Dosimetry

Purpose: With an MR-linac, radiation is delivered in the presence of a magnetic field. Modifications in the codes of practice (CoPs) for reference dosimetry are required to incorporate the effect of the magnetic field. Methods: In most CoPs the absorbed dose is determined using the well-known kQ formalism as the product of the calibration coefficient, the corrected electrometer reading and kQ, to account for the difference in beam quality. To keep a similar formalism a single correction factor is introduced which replaces kQ, and which corrects for beam quality and B-field, kQ,B. In this study we propose a method to determine kQ,B under reference conditions in the MRLinac without using a primary standard, as the product of:- the ratio between detector readings without and with B-field (kB),- the ratio between doses in the point of measurement with and without B-field (rho),- kQ in the absence of the B-field in the MRLinac beam (kQmrl0,Q0),The ratio of the readings, which covers the change in detector reading due to the different electron trajectories in the detector, was measured with a waterproof ionization chamber (IBA-FC65g) in a water phantom in the MRLinac without and with B-field. The change in dose-to-water in the point of measurement due to the B-field was determined with a Monte Carlo based TPS. Results: For the presented approach, the measured ratio of readings is 0.956, the calculated ratio of doses in the point of measurement is 0.995. Based on TPR20,10 measurements kQ was calculated as 0.989 using NCS-18. This yields a value of 0.9408 for kQ,B. Conclusion: The presented approach to determine kQ,B agrees with a method based on primary standards within 0.4% with an uncertainty of 1% (1 std.uncert). It differs from a similar approach using a PMMA-phantom and an NE2571 chamber with 1.3%.

60 APPLIED LIFE SCIENCES↗

A model for optimizing file access patterns using spatio-temporal parallelism. In: UltraVis '13 Proceedings of the 8th International Workshop on Ultrascale Visualization, Article No. 4

For many years now, I/O read time has been recognized as the primary bottleneck for parallel visualization and analysis of large-scale data. In this paper, we introduce a model that can estimate the read time for a file stored in a parallel filesystem when given the file access pattern. Read times ultimately depend on how the file is stored and the access pattern used to read the file. The file access pattern will be dictated by the type of parallel decomposition used. We employ spatio-temporal parallelism, which combines both spatial and temporal parallelism, to provide greater flexibility to possible file access patterns. Using our model, we were able to configure the spatio-temporal parallelism to design optimized read access patterns that resulted in a speedup factor of approximately 400 over traditional file access patterns.

Nouanesengsy, Boonthanome↗

ADEPT, a dynamic next generation sequencing data error-detection program with trimming

Illumina is the most widely used next generation sequencing technology and produces millions of short reads that contain errors. These sequencing errors constitute a major problem in applications such as de novo genome assembly, metagenomics analysis and single nucleotide polymorphism discovery. In this study, we present ADEPT, a dynamic error detection method, based on the quality scores of each nucleotide and its neighboring nucleotides, together with their positions within the read and compares this to the position-specific quality score distribution of all bases within the sequencing run. This method greatly improves upon other available methods in terms of the true positive rate of error discovery without affecting the false positive rate, particularly within the middle of reads. We conclude that ADEPT is the only tool to date that dynamically assesses errors within reads by comparing position-specific and neighboring base quality scores with the distribution of quality scores for the dataset being analyzed. The result is a method that is less prone to position-dependent under-prediction, which is one of the most prominent issues in error prediction. The outcome is that ADEPT improves upon prior efforts in identifying true errors, primarily within the middle of reads, while reducing the false positive rate.

59 BASIC BIOLOGICAL SCIENCES↗

Metagenomic analysis of planktonic microbial consortia from a non-tidal urban-impacted segment of James River

Knowledge of the diversity and ecological function of the microbial consortia of James River in Virginia, USA, is essential to developing a more complete understanding of the ecology of this model river system. Metagenomic analysis of James River's planktonic microbial community was performed for the first time using an unamplified genomic library and a 16S rDNA amplicon library prepared and sequenced by Ion PGM and MiSeq, respectively. From the 0.46-Gb WGS library (GenBank:SRR1146621; MG-RAST:4532156.3), 4 x 10 6 reads revealed >3 x 10 6 genes, 240 families of prokaryotes, and 155 families of eukaryotes. From the 0.68-Gb 16S library (GenBank:SRR2124995; MG-RAST:4631271.3; EMB:2184), 4 x 10 6 reads revealed 259 families of eubacteria. Results of the WGS and 16S analyses were highly consistent and indicated that more than half of the bacterial sequences were Proteobacteria , predominantly Comamonadaceae . The most numerous genera in this group were Acidovorax (including iron oxidizers, nitrotolulene degraders, and plant pathogens), which accounted for 10 % of assigned bacterial reads. Polaromonas were another 6 % of all bacterial reads, with many assignments to groups capable of degrading polycyclic aromatic hydrocarbons. Albidiferax (iron reducers) and Variovorax (biodegraders of a variety of natural biogenic compounds as well as anthropogenic contaminants such as polycyclic aromatic hydrocarbons and endocrine disruptors) each accounted for an additional 3% of bacterial reads. Comparison of these data to other publically-available aquatic metagenomes revealed that this stretch of James River is highly similar to the upper Mississippi River, and that these river systems are more similar to aquaculture and sludge ecosystems than they are to lakes or to a pristine section of the upper Amazon River. Altogether, these analyses exposed previously unknown aspects of microbial biodiversity, documented the ecological responses of microbes to urban effects, and revealed the noteworthy presence of 22 human-pathogenic bacterial genera (e.g., Enterobacteriaceae , pathogenic Pseudomonadaceae , and ‘Vibrionales' ) and 6 pathogenic eukaryotic genera (e.g., Trypanosomatidae and Vahlkampfiidae). This information about pathogen diversity may be used to promote human epidemiological studies, enhance existing water quality monitoring efforts, and increase awareness of the possible health risks associated with recreational use of James River.

54 ENVIRONMENTAL SCIENCES↗

FY11 Report on Metagenome Analysis using Pathogen Marker Libraries

A method, sequence library, and software suite was invented to rapidly assess whether any member of a pre-specified list of threat organisms or their near neighbors is present in a metagenome. The system was designed to handle mega- to giga-bases of FASTA-formatted raw sequence reads from short or long read next generation sequencing platforms. The approach is to pre-calculate a viral and a bacterial "Pathogen Marker Library" (PML) containing sub-sequences specific to pathogens or their near neighbors. A list of expected matches comparing every bacterial or viral genome against the PML sequences is also pre-calculated. To analyze a metagenome, reads are compared to the PML, and observed PML-metagenome matches are compared to the expected PML-genome matches, and the ratio of observed relative to expected matches is reported. In other words, a 3-way comparison among the PML, metagenome, and existing genome sequences is used to quickly assess which (if any) species included in the PML is likely to be present in the metagenome, based on available sequence data. Our tests showed that the species with the most PML matches correctly indicated the organism sequenced for empirical metagenomes consisting of a cultured, relatively pure isolate. These runs completed in 1 minute to 3 hours on 12 CPU (1 thread/CPU), depending on the metagenome and PML. Using more threads on the same number of CPU resulted in speed improvements roughly proportional to the number of threads. Simulations indicated that detection sensitivity depends on both sequencing coverage levels for a species and the size of the PML: species were correctly detected even at ~0.003x coverage by the large PMLs, and at ~0.03x coverage by the smaller PMLs. Matches to true positive species were 3-4 orders of magnitude higher than to false positives. Simulations with short reads (36 nt and ~260 nt) showed that species were usually detected for metagenome coverage above 0.005x and coverage in the PML above 0.05x, and detection probability appears to be a function of both coverages. Multiple species could be detected simultaneously in a simulated low-coverage, complex metagenome, and the largest PML gave no false negative species and no false positive genera. The presence of multiple species was predicted in a complex metagenome from a human gut microbiome with 1.9 GB of short reads (75 nt); the species predicted were reasonable gut flora and no biothreat agents were detected, showing the feasibility of PML analysis of empirical complex metagenomes.

59 BASIC BIOLOGICAL SCIENCES↗

A Two-Step PCR Protocol Enabling Flexible Primer Choice and High Sequencing Yield for Illumina MiSeq Meta-Barcoding

High-throughput amplicon sequencing that primarily targets the 16S ribosomal DNA (rDNA) (for bacteria and archaea) and the Internal Transcribed Spacer rDNA (for fungi) have facilitated microbial community discovery across diverse environments. A three-step PCR that utilizes flexible primer choices to construct the library for Illumina amplicon sequencing has been applied to several studies in forest and agricultural systems. The three-step PCR protocol, while producing high-quality reads, often yields a large number (up to 46%) of reads that are unable to be assigned to a specific sample according to its barcode. Here, we improve this technique through an optimized two-step PCR protocol. We tested and compared the improved two-step PCR meta-barcoding protocol against the three-step PCR protocol using four different primer pairs (fungal ITS: ITS1F-ITS2 and ITS1F-ITS4, and bacterial 16S: 515F-806R and 341F-806R). We demonstrate that the sequence quantity and recovery rate were significantly improved with the two-step PCR approach (fourfold more read counts per sample; determined reads ≈90% per run) while retaining high read quality (Q30 > 80%). Given that synthetic barcodes are incorporated independently from any specific primers, this two-step PCR protocol can be broadly adapted to different genomic regions and organisms of scientific interest.

16S rDNA↗

Benchmarking viromics: an in silico evaluation of metagenome-enabled estimates of viral community composition and diversity

Background: Viral metagenomics (viromics) is increasingly used to obtain uncultivated viral genomes, evaluate community diversity, and assess ecological hypotheses. While viromic experimental methods are relatively mature and widely accepted by the research community, robust bioinformatics standards remain to be established. Here we used in silico mock viral communities to evaluate the viromic sequence-to-ecological-inference pipeline, including (i) read pre-processing and metagenome assembly, (ii) thresholds applied to estimate viral relative abundances based on read mapping to assembled contigs, and (iii) normalization methods applied to the matrix of viral relative abundances for alpha and beta diversity estimates. Results: Tools specifically designed for metagenomes, specifically metaSPAdes, MEGAHIT, and IDBA-UD, were the most effective at assembling viromes. Read pre-processing, such as partitioning, had virtually no impact on assembly output, but may be useful when hardware is limited. Viral populations with 2–5 × coverage typically assembled well, whereas lesser coverage led to fragmented assembly. Strain heterogeneity within populations hampered assembly, especially when strains were closely related (average nucleotide identity, or ANI ≥97%) and when the most abundant strain represented <50% of the population. Viral community composition assessments based on read recruitment were generally accurate when the following thresholds for detection were applied: (i) ≥10 kb contig lengths to define populations, (ii) coverage defined from reads mapping at ≥90% identity, and (iii) ≥75% of contig length with ≥1 × coverage. Finally, although data are limited to the most abundant viruses in a community, alpha and beta diversity patterns were robustly estimated (±10%) when comparing samples of similar sequencing depth, but more divergent (up to 80%) when sequencing depth was uneven across the dataset. In the latter cases, the use of normalization methods specifically developed for metagenomes provided the best estimates. Conclusions: These simulations provide benchmarks for selecting analysis cut-offs and establish that an optimized sample-to-ecological-inference viromics pipeline is robust for making ecological inferences from natural viral communities. Continued development to better accessing RNA, rare, and/or diverse viral populations and improved reference viral genome availability will alleviate many of viromics remaining limitations.

59 BASIC BIOLOGICAL SCIENCES↗

Software approach to automatic patching of analog computer

The Automatic Patching Verification program (APV) is described which provides the hybrid computer programmer with a convenient method of performing a static check of the analog portion of his study. The static check insures that the program is patched as specified, and that the computing components being used are operating correctly. The APV language the programmer uses to specify his conditions and interconnections is similar to the FORTRAN language in syntax. The APV control program reads APV source program statements from an assigned input device. Each source program statement is processed immediately after it is read. A statement may select an analog console, set an analog mode, set a potentiometer or DAC, or read from the analog console and perform a test. Statements are read and processed sequentially. If an error condition is detected, an output occurs on an assigned output device. When an end statement is read, the test is terminated.

Source record↗

Development of an Automated Reader for Analysis and Storage of Personnel Dosimeter Badge Data

The collection and archiving of data from personnel dosimeters has become increasingly important in light of the lowered Threshold Limit Values (TLV) for HydraZine (HZ), MonoMethylHydrazine (MMH), and Unsymmetrical DiMethylHydrazine (UDMH). The American Conference of Government Industrial Hygienists (ACGIH) lowered the TLV from 100 parts per billion (ppb) to IO ppb and has caused increased concern over long term exposures of personnel to trace levels of these hypergols and other potentially harmful chemicals. An automated system of reading the exposure levels of personnel dosimeters and storing exposure data for subsequent evaluation has been developed. The reading of personnel dosimeter badges for exposure to potentially harmful vapor concentrations of hydrazines or other chemicals is performed visually by comparing the color developed by the badge with a calibrated color comparator. The result obtained using visual comparisons of the developed badge color with the comparator may vary widely from user to user. The automated badge reader takes the variability out of the dosimeter reading by accurately comparing the reflectance obtained from a colored spot on the badge with a reading on the same spot prior to any exposure to chemical vapors. The observed difference between the reflectance values is used as part of a calculation of the dose value for the badge based on a stored calibration curve. The badge reader also stores bar-code data unique to each badge, as well as bar-code information on the user, as part of the permanent badge record. The start and stop exposure times for each badge are recorded and can be used as part of the calculated concentration, in ppm, for each badge logged during a recording period. The badge reader is equipped with a number of badge holders, each of which is unique to a specific type of personnel dosimeter badge. This gives the reader maximum flexibility to allow for the reading of several different types of badges. Test results of the badge reader for several different types of personnel dosimeter badges are presented within the body of this paper.

Meneghelli, B. J.↗

Development of an Automated Reader for Analysis and Storage of Personnel Dosimeter Badge Data

The collection and archiving of data from personnel dosimeters has become increasingly important in light of the lowered threshold limit values (TLV) for hydrazine (HZ), monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH). The American Conference of Government Industrial Hygienists (ACGIH) lowered the TLV from 100 parts per billion (ppb) to 10 ppb and has caused increased concern over long term exposures of personnel to trace levels of these hypergols and other potentially harmful chemicals. An automated system of reading the exposure levels of personnel dosimeters and storing exposure data for subsequent evaluation has been developed. The reading of personnel dosimeter badges for exposure lo potentially harmful vapor concentrations of hydrazines or other chemicals is performed visually by comparing the color developed by the badge with a calibrated color comparator. The result obtained using visual comparisons of the developed badge color with the comparator may vary widely from user to user. The automated badge reader takes the variability out of the dosimeter reading by accurately comparing the reflectance obtained from a colored spot on the badge with a reading on the same spot prior to any exposure to chemical vapors. The observed difference between the reflectance values is used as part of a calculation of the dose value for the badge based on a stored calibration curve. The badge reader also stores bar-code data unique to each badge, as well as bar-code information on the user, as part of the permanent badge record. The start and stop exposure times for each badge are recorded and can be used as part of the calculated concentration, in ppm, for each badge logged during a recording period. The badge reader is equipped with a number of badge holders, each of which is unique to a specific type of personnel dosimeter badge. This gives the reader maximum flexibility to allow for the reading of several different types of badges. Test results of the badge reader for several different types of personnel dosimeter badges are presented within the body of this paper.

Meneghelli, B. J.↗

Hiding the Disk and Network Latency of Out-of-Core Visualization

This paper describes an algorithm that improves the performance of application-controlled demand paging for out-of-core visualization by hiding the latency of reading data from both local disks or disks on remote servers. The performance improvements come from better overlapping the computation with the page reading process, and by performing multiple page reads in parallel. The paper includes measurements that show that the new multithreaded paging algorithm decreases the time needed to compute visualizations by one third when using one processor and reading data from local disk. The time needed when using one processor and reading data from remote disk decreased by two thirds. Visualization runs using data from remote disk actually ran faster than ones using data from local disk because the remote runs were able to make use of the remote server's high performance disk array.

Ellsworth, David↗

Algorithm for Detecting a Bright Spot in an Image

An algorithm processes the pixel intensities of a digitized image to detect and locate a circular bright spot, the approximate size of which is known in advance. The algorithm is used to find images of the Sun in cameras aboard the Mars Exploration Rovers. (The images are used in estimating orientations of the Rovers relative to the direction to the Sun.) The algorithm can also be adapted to tracking of circular shaped bright targets in other diverse applications. The first step in the algorithm is to calculate a dark-current ramp a correction necessitated by the scheme that governs the readout of pixel charges in the charge-coupled-device camera in the original Mars Exploration Rover application. In this scheme, the fraction of each frame period during which dark current is accumulated in a given pixel (and, hence, the dark-current contribution to the pixel image-intensity reading) is proportional to the pixel row number. For the purpose of the algorithm, the dark-current contribution to the intensity reading from each pixel is assumed to equal the average of intensity readings from all pixels in the same row, and the factor of proportionality is estimated on the basis of this assumption. Then the product of the row number and the factor of proportionality is subtracted from the reading from each pixel to obtain a dark-current-corrected intensity reading. The next step in the algorithm is to determine the best location, within the overall image, for a window of N N pixels (where N is an odd number) large enough to contain the bright spot of interest plus a small margin. (In the original application, the overall image contains 1,024 by 1,024 pixels, the image of the Sun is about 22 pixels in diameter, and N is chosen to be 29.)

Source record↗

Analog Nonvolatile Computer Memory Circuits

In nonvolatile random-access memory (RAM) circuits of a proposed type, digital data would be stored in analog form in ferroelectric field-effect transistors (FFETs). This type of memory circuit would offer advantages over prior volatile and nonvolatile types: In a conventional complementary metal oxide/semiconductor static RAM, six transistors must be used to store one bit, and storage is volatile in that data are lost when power is turned off. In a conventional dynamic RAM, three transistors must be used to store one bit, and the stored bit must be refreshed every few milliseconds. In contrast, in a RAM according to the proposal, data would be retained when power was turned off, each memory cell would contain only two FFETs, and the cell could store multiple bits (the exact number of bits depending on the specific design). Conventional flash memory circuits afford nonvolatile storage, but they operate at reading and writing times of the order of thousands of conventional computer memory reading and writing times and, hence, are suitable for use only as off-line storage devices. In addition, flash memories cease to function after limited numbers of writing cycles. The proposed memory circuits would not be subject to either of these limitations. Prior developmental nonvolatile ferroelectric memories are limited to one bit per cell, whereas, as stated above, the proposed memories would not be so limited. The design of a memory circuit according to the proposal must reflect the fact that FFET storage is only partly nonvolatile, in that the signal stored in an FFET decays gradually over time. (Retention times of some advanced FFETs exceed ten years.) Instead of storing a single bit of data as either a positively or negatively saturated state in a ferroelectric device, each memory cell according to the proposal would store two values. The two FFETs in each cell would be denoted the storage FFET and the control FFET. The storage FFET would store an analog signal value, between the positive and negative FFET saturation values. This signal value would represent a numerical value of interest corresponding to multiple bits: for example, if the memory circuit were designed to distinguish among 16 different analog values, then each cell could store 4 bits. Simultaneously with writing the signal value in the storage FFET, a negative saturation signal value would be stored in the control FFET. The decay of this control-FFET signal from the saturation value would serve as a model of the decay, for use in regenerating the numerical value of interest from its decaying analog signal value. The memory circuit would include addressing, reading, and writing circuitry that would have features in common with the corresponding parts of other memory circuits, but would also have several distinctive features. The writing circuitry would include a digital-to-analog converter (DAC); the reading circuitry would include an analog-to-digital converter (ADC). For writing a numerical value of interest in a given cell, that cell would be addressed, the saturation value would be written in the control FFET in that cell, and the non-saturation analog value representing the numerical value of interest would be generated by use of the DAC and stored in the storage FFET in that cell. For reading the numerical value of interest stored in a given cell, the cell would be addressed, the ADC would convert the decaying control and storage analog signal values to digital values, and an associated fast digital processing circuit would regenerate the numerical value from digital values.

MacLeod, Todd↗

Gigabit Ethernet Asynchronous Clock Compensation FIFO

Clock compensation for Gigabit Ethernet is necessary because the clock recovered from the 1.25 Gb/s serial data stream has the potential to be 200 ppm slower or faster than the system clock. The serial data is converted to 10-bit parallel data at a 125 MHz rate on a clock recovered from the serial data stream. This recovered data needs to be processed by a system clock that is also running at a nominal rate of 125 MHz, but not synchronous to the recovered clock. To cross clock domains, an asynchronous FIFO (first-in-first-out) is used, with the write pointer (wprt) in the recovered clock domain and the read pointer (rptr) in the system clock domain. Because the clocks are generated from separate sources, there is potential for FIFO overflow or underflow. Clock compensation in Gigabit Ethernet is possible by taking advantage of the protocol data stream features. There are two distinct data streams that occur in Gigabit Ethernet where identical data is transmitted for a period of time. The first is configuration, which happens during auto-negotiation. The second is idle, which occurs at the end of auto-negotiation and between every packet. The identical data in the FIFO can be repeated by decrementing the read pointer, thus compensating for a FIFO that is draining too fast. The identical data in the FIFO can also be skipped by incrementing the read pointer, which compensates for a FIFO draining too slowly. The unique and novel features of this FIFO are that it works in both the idle stream and the configuration streams. The increment or decrement of the read pointer is different in the idle and compensation streams to preserve disparity. Another unique feature is that the read pointer to write pointer difference range changes between compensation and idle to minimize FIFO latency during packet transmission.

Duhachek, Jeff↗