Search NASA⌕ Search

SEARCH · Search NASA

Results for “Robotics Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Development of high-performance X-ray transparent crystallization plates for in situ protein crystal screening and analysis

An optically, UV and X-ray transparent crystallization plate suitable for in situ analysis has been developed. The plate uses contact line pinning rather than wells to confine the liquids. X-ray transparent crystallization plates based upon a novel drop-pinning technology provide a flexible, simple and inexpensive approach to protein crystallization and screening. The plates consist of open cells sealed top and bottom by thin optically, UV and X-ray transparent films. The plates do not need wells or depressions to contain liquids. Instead, protein drops and reservoir solution are held in place by rings with micrometre dimensions that are patterned onto the bottom film. These rings strongly pin the liquid contact lines, thereby improving drop shape and position uniformity, and thus crystallization reproducibility, and simplifying automated image analysis of drop contents. The same rings effectively pin solutions containing salts, proteins, cryoprotectants, oils, alcohols and detergents. Strong pinning by rings allows the plates to be rotated without liquid mixing to 90° for X-ray data collection or to be inverted for hanging-drop crystallization. The plates have the standard SBS format and are compatible with standard liquid-handling robots.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Designing, synthesizing, and modeling active fluids

We review recent advances in the design, synthesis, and modeling of active fluids. Active fluids have been at the center of many technological innovations and theoretical advances over the past two decades. Research on this new class of fluids has been inspired by the fascinating and remarkably efficient strategies that biological systems employ, leading to the development of biomimetic nano- and micro-machines and swimmers. The review encompasses active fluids on both the nano- and micro-scale. We start with examples of biological active systems before we discuss how experimentalists leverage novel propulsion mechanisms to power nano- and micro-machines. Furthermore, we then examine how the study of these far-from-equilibrium systems has prompted the development of new simulation methods and theoretical models in nonequilibrium physics to account for their mechanical, thermodynamic, and emergent properties. Recent advances in the field have paved the way for the design, synthesis, and modeling of autonomous systems at the nano- and micro-scale and opened the door to the development of soft matter robotics.

36 MATERIALS SCIENCE↗

Small Reactor Designs Suitable for Direct Nuclear Thermal Propulsion (Interim Report)

Advancement of U.S. scientific, security, and economic interests requires high performance propulsion systems to support missions beyond low Earth orbit. A robust space exploration program will include robotic outer planet and crewed missions to a variety of destinations including the moon, near Earth objects, and eventually Mars. Past studies, in particular those in support of both the Strategic Defense Initiative (SDI) and the Space Exploration Initiative (SEI), have shown nuclear thermal propulsion systems provide superior performance for high mass high propulsive delta-V missions. In NASA's recent Mars Design Reference Architecture (DRA) 5.0 study, nuclear thermal propulsion (NTP) was again selected over chemical propulsion as the preferred in-space transportation system option for the human exploration of Mars because of its high thrust and high specific impulse (~900 s) capability, increased tolerance to payload mass growth and architecture changes, and lower total initial mass in low Earth orbit. The recently announced national space policy supports the development and use of space nuclear power systems where such systems safely enable or significantly enhance space exploration or operational capabilities. An extensive nuclear thermal rocket technology development effort was conducted under the Rover/NERVA, GE-710 and ANL nuclear rocket programs (1955-1973). Both graphite and refractory metal alloy fuel types were pursued. The primary and significantly larger Rover/NERVA program focused on graphite type fuels. Research, development, and testing of high temperature graphite fuels was conducted. Reactors and engines employing these fuels were designed, built, and ground tested. The GE-710 and ANL programs focused on an alternative ceramic-metallic 'cermet' fuel type consisting of UO 2 (or UN) fuel embedded in a refractory metal matrix such as tungsten. The General Electric program examined closed loop concepts for space or terrestrial applications as well as open loop systems for direct nuclear thermal propulsion. Although a number of fast spectrum reactor and engine designs suitable for direct nuclear thermal propulsion were proposed and designed, none were built. This report summarizes status results of evaluations of small nuclear reactor designs suitable for direct nuclear thermal propulsion.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Update on Investigations of Viability of Cold Spray and FSW as a Spent Nuclear Fuel Dry Storage Canister Mitigation Tool

The purpose of this work is to investigate the use of cold spray and friction stir welding or processing (FSW/P) for repair and mitigation of chloride-induced stress corrosion cracking (CISCC) in dry cask storage system (DCSS) canisters to ensure integrity far beyond their original license period. This report provides a viability analysis of cold spray and friction stir welding for repair and fabrication of DCSS canisters. This report presents experimental work and a research strategy to optimize and evaluate cold spray and FSW/P for CISCC resistance. The literature reports that the following three conditions must exist for CISCC to occur: tensile stress, corrosive environment, and susceptible material. These conditions must be understood and accounted for while evaluating CISCC susceptibility. Furthermore, non-obvious factors, such as surface conditions and geometric confinement, can dramatically increase the intensity of one or more of the three listed conditions for CISCC. Arc welding should be considered for either temporary or permanent repair when combined with a mitigation technology. It is known that alloys used in the existing inventory of spent nuclear fuel storage canisters become sensitized in areas around fusion welds. Technologies, such as cold spray or FSW, can mitigate the sensitization caused by fusion welds. FSW/P and cold spray, potential alternatives for fabrication and repair, are solid-phase processes. No melting occurs and the energy input can be controlled such that no harm is done to the base metal during these processes. FSW/P should be considered for use in new fabrication of canisters and repair of existing canisters. Low heat input and grain refinement result in material with improved mechanical properties and comparable generalized corrosion performance relative to base metal. FSW/P offers the potential of through-thickness CISCC resistance. Cold spray should be considered for production, mitigation, and repair of canisters. Cold spray has demonstrated the ability to deposit stainless steel, Inconel alloys, and other alloys on stainless steel 304L such that galvanic potential is matched and resistance to pitting is improved. The technical basis for cold spray mitigation and repair within the overpack using remote robotic equipment is established. A non-obvious application to the research community is the sealing of crevices. All reported instances of CISCC in the fielded nuclear applications were associated with crevice corrosion. This can be avoided by cold spraying to seal crevices. The bulk of the work planned for FY 2020 will be generating coupons for CISCC testing by collaborative projects at Pacific Northwest National Laboratory and Sandia National Laboratories. First an exploratory study will be executed that will include screening studies and process optimization. This task will identify the effect of process parameters on microstructure and CISCC resistance. Optimized parameters will be used to produce a smaller number of coupons for full testing and evaluation. Test methods for evaluating CISCC resistance must meet the following criteria: (1) normalized surface geometry and exposed process microstructure, (2) account for residual stresses, (3) be in a controlled and appropriate test environment, and (4) be numerically quantifiable and repeatable. Failure to meet these criteria could lead to results that cannot be used for comparative analysis of processes and materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

How Advances in Imaging Will Affect Precision Radiation Oncology

Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set–rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose–volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology–National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

OAOWFC: Okayama Astrophysical Observatory NIR Wide-Field Camera

In order to detect and trace the early phase of near-infrared (NIR) afterglows of Gamma Ray Bursts (GRBs) quickly, we are now developing the Okayama Astrophysical Observatory Wide-Field Camera, OAOWFC. The aperture size of OAOWFC is 91 cm. The focal plane is covered by a 2Kx2K HAWAII2-RG detector with a pixel size of 18.5 {mu}mx18.5 {mu}m, resulting 0.95x0.95 deg{sup 2} field of view with an image scale of 1.6 arcsec/pixel. OAOWFC is designed to be a fully robotic instrument. This camera forms a part of Multicolor Imaging Telescopes for Survey and Monstrous Explosions (MITSuME), a multi telescope system dedicated to optical-NIR follow-up observations of GRB afterglows. Very wide field of view of OAOWFC enables us to catch GRB afterglows under less accurate localization sometimes given by the first alert. OAOWFC has an ability to detect bright GRB afterglow located at z = 10 easily, and it might be detectable at z = 18 if the conditions are met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TESTING OF THE RADBALL TECHNOLOGY AT SAVANNAH RIVER NATIONAL LABORATORY

The United Kingdom's National Nuclear Laboratory (NNL) has developed a remote, nonelectrical, radiation-mapping device known as RadBall (patent pending), which offers a means to locate and quantify radiation hazards and sources within contaminated areas of the nuclear industry. Positive results from initial deployment trials in nuclear waste reprocessing plants at Sellafield in the United Kingdom and the anticipated future potential use of RadBall throughout the U.S. Department of Energy Complex have led to the NNL partnering with the Savannah River National Laboratory (SRNL) to further test, underpin, and strengthen the technical performance of the technology. The study completed at SRNL addresses key aspects of the testing of the RadBall technology. The first set of tests was performed at Savannah River Nuclear Solutions Health Physics Instrument Calibration Laboratory (HPICL) using various gamma-ray sources and an x-ray machine with known radiological characteristics. The objective of these preliminary tests was to identify the optimal dose and collimator thickness. The second set of tests involved a highly contaminated hot cell. The objective of this testing was to characterize a hot cell with unknown radiation sources. The RadBall calibration experiments and hot cell deployment were successful in that for each trial radiation tracks were visible. The deployment of RadBall can be accomplished in different ways depending on the size and characteristics of the contaminated area (e.g., a hot cell that already has a crane/manipulator available or highly contaminated room that requires the use of a remote control device with sensor and video equipment to position RadBall). This report also presents SRNL-designed RadBall accessories for future RadBall deployment (a harness, PODS, and robot).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and Implementation of a Facility for Discovering New Scintillator Materials

We describe the design and operation of a high-throughput facility for synthesizing thousands of inorganic crystalline samples per year and evaluating them as potential scintillation detector materials. This facility includes a robotic dispenser, arrays of automated furnaces, a dual-beam X-ray generator for diffractometery and luminescence spectroscopy, a pulsed X-ray generator for time response measurements, computer-controlled sample changers, an optical spectrometer, and a network-accessible database management system that captures all synthesis and measurement data.

36 MATERIALS SCIENCE↗

High-Fidelity Accelerated Design of High-performance Electrochemical Systems

Large-scale electrification is vital to addressing the climate crisis, but several scientific and technological challenges remain to fully electrify both the chemical industry and transportation. In both of these areas, new electrochemical materials will be critical, but their development currently relies heavily on human-time-intensive experimental trial and error and computationally expensive first-principles, meso-scale and continuum simulations. To accelerate this process, our team has developed the AutoMat platform. AutoMat can accelerate development of new electrochemical materials along two avenues: first, automated input generation and management of simulations at multiple lengthscales as well as “handoff” of outputs from one lengthscale as inputs to the next; and second, replacement of the most computationally intensive simulation processes with machine-learned surrogate models. The crux of our team’s effort was not “reinventing the wheel” by developing entirely new techniques, but rather building a “superhighway” that allows existing state-of-the-art techniques to run faster and more smoothly than before. AutoMat can utilize tools spanning from first-principles quantum chemistry computations to automated robotic experimentation, and is driven by design space search techniques to reduce the number of iterations through the full simulation loop by rapidly targeting promising regions of design spaces such as single-atom alloy catalysts or blends of liquid electrolytes.

25 ENERGY STORAGE↗

Methods for Mapping of Surface Charge Density on Arbitrary Dielectric Objects

A system to map surface charge densities on dielectric objects – e.g. PTFE, PMMA, and PA6 – is described to study maximum surface charge limits discharge and decay characteristics. Two electromechanical movements are used to achieve these goals: a three-axis robotic arm with an electrostatic probe and a three-axis auxiliary movement fitted with a current viewing resistor and laser displacement sensor. Dielectric objects no larger than a cylinder of eight-inch diameter and twelve inches in height are analyzed to create surface point clouds and generate a set of scan points. The arbitrary object is positioned upon a rotational axis with a laser displacement sensor oriented radially towards the rotational axis of the platform to determine the object’s physical limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Importance Sampling Model-Based Diffusion for Trajectory Optimization

Trajectory optimization for robotic systems remains a challenging problem. This is especially true for robotic systems featuring nonlinear dynamics and many degrees of freedom. Data-based or model-free diffusion has recently been popularized in the fields of artificial intelligence and trajectory optimization. Model-Based Diffusion provides a data-free method of trajectory optimization, trained at runtime on a system dynamics model, suitable for high-dimensional models. This paper examines how importance sampling can enhance the performance of Model-Based Diffusion for trajectory optimization. Here, we quantify the benefits of importance sampling across three long horizon planning tasks. These results show as much as a 13x improvement in sample efficiency depending on environment and optimization parameters.

Golembeski, Seth [Georgia Institute of Technology,↗

Development of the Intelligent, Preventive Infrared (IR) Inspection System Housed in Hybrid Robotic Platforms

Robots and robotic systems that are designed for inspection, environmental study, and health and safety aid are becoming an increasing necessity. However, there is a number of challenges that accompany robots that are designed for these specific applications. These challenges include: navigating compact, enclosed spaces, travelling over multiple terrains and large obstacles, using the proper sensing and detection methods to assess an environment, and the use of lightweight and durable materials. The robotic platforms currently in development look at all of these challenges and attempt to overcome them. These designs specific use of hybrid robotic platforms, or platform that utilizes soft and rigid materials, allows for a more flexible platform and makes environments more navigable. To further improve the navigation of the platforms and environmental assessment, a novel infrared detection system is housed in the platforms to create a robot that can be used for the applications listed above and more. Objectives: Further develop two types of robotic platforms that utilize additive manufacturing, soft materials, and rigid materials. Continue the development of an intelligent and inhibitory infrared detection system based on an artificial intelligence (AI) algorithm. Continued study and fabrication of active soft materials designed for both sensing and actuation in hybrid robotic systems. Improve additive manufacturing fabrication to design rigid and semi-rigid components for hybrid robotic platforms. Transformable Wheel Robotic Platform: The chassis, wheels, tires and inspection system housing use different additive manufacturing techniques for fabrication. Continued work with additive manufacturing has lead to studies in metal-based printing and modular design and manufacturing. The new platform design with integrated electrical component printed. This will allow integration of the sensor housing onto the platform. Electrical components are being tested for battery life and performance. To improve this performance, such as integration of Lithium Polymer (LiPo) batteries. Snake Robotic Platform: The main focus of the development has centered around liquid-based soft actuators. That act on the principles of electrostatic and hydraulic actuation. A liquid dielectric sits between two compliant electrodes, contained by a flexible polymer shell. The electrodes and film gradually collapse toward each other from one corner of the electrode to the other. When the electrodes and film close together, a majority of the fluid is pushed into the area not covered by an electrode. A thin layer of the liquid dielectric remains between the electrode. The actuators will be stacked to cause large displacement, and move the linkages. The chassis of this platform uses purely additively manufactured linkages. Intelligent, Preventive IR Inspection System: Development of the AI for the system has lead to using a Scikit-Learn which assists in creating predictive models based on Regression, clustering, classification etc. To improve the infrared thermometry for low emissivity sources, work on the fabrication of a tandem photoconductive infrared thermometer was a main focus. Distance-Voltage-Temperature response data has been collected in the range of 7 cm - 100 cm and 200-400 deg. C. Modifications were made to the existing test bench to have a better control over the data. Automated data collection was realized using a Python code and an Arduino controlled stepper motor to increase the sample rate. A protective enclosure has been built around the setup to minimize the effect of the environment on the measurements. To better predict temperature, different AI models are being optimized. The regression model, LARS showed a high accuracy but had convergence issues and only works for the current test set-up. Results: The Transformable Wheel Robot has developed into a more flexible and modular platform. With the improvements to the current work, effort on the tire or soft gripper design been a large focus. The soft grippers will be interchange able to allow for increased performance in identified terrain types. The development of the liquid-based actuators allows the snake robotic platform to achieve the goals of being flexible and able to navigate confined spaces. However, there is room for improvement. Optimization work is currently being done in COMSOL Multiphysics. With the current IR system set-up the LARS model perfectly predicts the data; however, considering the mobility aspect of the project other models will allow for an optimized system. Testing of other model types is currently being done.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zwitterionic Photocurable Resin for High‐Resolution 3D Printing of Ultralow‐Fouling Microstructures

High‐resolution 3D printing technologies are enabling a new generation of microstructured materials for applications where biocompatibility is critical. However, most conventional 3D‐printable resins yield materials that exhibit trade‐offs between antifouling properties and mechanical robustness, limiting their applicability in living systems. In nature, zwitterionic surface groups form tightly bound hydration layers that act as effective barriers against protein and cell attachment. Inspired by this strategy, a zwitterionic acrylamide‐based photoresist—carboxybetaine di‐methacrylamide (CBDA)—is developed for projection‐based vat photopolymerization, enabling the fabrication of complex microarchitectures with exceptional antifouling properties. The bifunctional monomer allows the formation of dense, cross‐linked networks that resist swelling while maintaining a high density of zwitterionic groups. Printed structures exhibit strong resistance to protein and cell adhesion, as confirmed by porcine blood assays, alongside robust mechanical performance. As a demonstration, a tubular structure featuring a negative Poisson's ratio lattice is printed to showcase structural fidelity and versatility. This resin formulation offers a broadly applicable strategy for fabricating microscale devices and surfaces where antifouling performance and structural integrity are both essential—spanning biomedical interfaces, soft robotics, and beyond.

3D printing↗

ALFA Shared Autonomy Manipulation Data with a Seabotix vLBV300

This report outlines marine field demonstrations for manipulation tasks with a semi-Autonomous Underwater Vehicle (sAUV). The vehicle is built off a Seabotix vLBV300 platform with custom software interfacing it with the Robot Operating System (ROS). The vehicle utilizes an inertial navigation system available from Greensea Systems, Inc. based on a Gladiator Landmark 40 IMU coupled with a Teledyne Explorer Doppler Velocity Log to perform station keeping at a desired location and orientation. We performed two marine trials with the vehicle: a near-shore shared autonomy manipulation trial and an offshore attempted intervention trial. These demonstrations were designed to show the capabilities of our sAUV system for inspection and basic manipulation tasks in real marine environments.

16 TIDAL AND WAVE POWER↗

Machine Learning Algorithms for Automated NIF Capsule Mandrel Selection

Small shells, approximately 2 mm in diameter, made from Poly(α-methylstyrene) (PAMS) are used as mandrels in the production of glow discharge polymer capsules located at the center of inertial confinement fusion experiments. The visual inspection process of microscope images of these shell mandrels, including detection of micron-sized defects on the shell surface as well as the handling and sorting, is a very labor-intensive, repetitive, and highly subjective process that stands to benefit greatly from automation. As part of an effort to decrease the number of labor hours spent in capsule handling, inspection, and metrology, the development of robotic systems was presented in a paper by Carlson et al., “Automation in Target Fabrication” [Fusion Sci. Technol., Vol. 70, p. 274 (2016)]. The current work expands the automated image acquisition systems developed previously and adds the use of convolutional neural networks to select capsules best suited for use in the downstream production process. Through the use of these machine learning algorithms, the selection process becomes robust, repeatable, and operator independent. Finally, as an added benefit the system developed as part of this work is able to provide defect statistics on entire shell batches and feed this information upstream to the production team.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact low resolution spectrograph, an imaging and long slit spectrograph for robotic telescopes

The COmpact LOw REsolution Spectrograph (COLORES) is a compact and lightweight (13 kg) f/8 imaging spectrograph designed for robotic telescopes, now installed and operating on the TELMA, a rapid-slewing 60 cm telescope of the BOOTES-2 observatory in Málaga (Spain). COLORES is a multi-mode instrument that enables the observer to seamlessly switch between low-dispersion spectroscopy and direct imaging modes during an observation. In this paper, we describe the instrument and its development, from the initial scientific requirements through the optical design process to final configuration with theoretical performance calculations. The mechanical and electronic design is described, methods of calibration are discussed and early laboratory and scientific results are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗