Calibration of measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy using a contact detection method

An accurate experimental method is proposed for on-spot calibration of the measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy. One of the key techniques devised for this method is a reliable contact detection mechanism that detects the tip-surface contact instantly. At the contact instant, the oscillation amplitude of the tip deflection, converted to that of the deflection signal in laser reading through the measurement sensitivity, exactly equals to the distance between the sample surface and the cantilever base position. Therefore, the proposed method utilizes the recorded oscillation amplitude of the deflection signal and the base position of the cantilever at the contact instant for the measurement sensitivity calibration. Experimental apparatus along with various signal processing and control modules was realized to enable automatic and rapid acquisition of multiple sets of data, with which the calibration of a single dynamic mode could be completed in less than 1 s to suppress the effect of thermal drift and measurement noise. Calibration of the measurement sensitivities of the first and second dynamic modes of three micro-cantilevers having distinct geometries was successfully demonstrated. The dependence of the measurement sensitivity on laser spot location was also experimentally investigated. Finally, an experiment was performed to validate the calibrated measurement sensitivity of the second dynamic mode of a micro-cantilever.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of intrinsic magnetostriction on tube-topology magnetoelectric sensors with high magnetic field sensitivity

Three quasi-one-dimensional magnetoelectric (ME) magnetic field sensors, each with a different magnetostrictive wire material, were investigated in terms of sensitivity and noise floor. Magnetostrictive Galfenol, iron-cobalt-vanadium, and iron-nickel wires were examined. Sensitivity profiles, hysteresis effects, and noise floor measurements for both optimally biased and zero-biased conditions are presented. The FeNi wire (FN) exhibits high sensitivity (5.36 mV/Oe) at bias fields below 22 Oe and an optimal bias of 10 Oe, whereas FeGa wire (FG) exhibits higher sensitivity (6.89 mW/Oe) at bias fields >22 Oe. The sensor of FeCoV wire (FC) presents relatively low sensitivity (2.12 mV/Oe), due to low magnetostrictive coefficient. Each ME tube-topology sensor demonstrates relatively high sensitivity at zero bias field, which results from a magnetic shape anisotropy and internal strain of the thin magnetostrictive wire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel method to control explosive shock sensitivity: Formulations, experiments and modeling

The microstructure of a heterogeneous high explosive (HE) affects its shock initiation sensitivity and detonation performance. Alteration of the void content and/or void structure (i.e., bulk heating or mechanical damage) therefore changes the shock initiation behavior. Controlling and predicting the change in shock sensitivity after an HE has undergone microstructural changes addresses an important and challenging goal for the design and understanding of novel energetic material formulations. In this study, we aimed to develop HE systems to precisely tune shock sensitivity by a thermal treatment prior to use. Specifically, we incorporated a small fraction (1 wt% or less) of thermally expandable microspheres (TEMs) during the formulation process of various plastic-bonded explosives (PBX). TEMs typically consist of a thermoplastic acrylonitrile shell (10-50 µm diameter), which encapsulates an inert low boiling hydrocarbon. Upon heating, the TEMs expand as the shell softens while the hydrocarbon gasifies, increasing the internal pressure and expanding the particle by as much as 120 vol% (irreversibly). Here, we present our progress on shock sensitivity comparisons of HE formulations doped with TEMs after heating and expansion. Experiments, using Composition C-4 thermally cycled to 120°C, showed an increase in shock sensitivity. Additionally, mesoscale modeling revealed that the TEM itself does not act as a hotspot, but instead has a secondary effect on the response of nearby voids. We conclude that TEMs indeed do provide a method to tune shock sensitivity. Further, our results emphasize the non-uniformity of shock waves at the mesoscale, and that upstream defects influence the reactivity of downstream defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and investigation into explosive sensitivity for a series of new picramide explosives

Tailoring the molecular properties that govern energetic material sensitivity is essential to improve safety and help develop new energetic materials. Despite this need, understanding the complex chemistry and physics of explosive initiation and propagation is still a challenge. Recent work by our group has reinforced the view that explosive sensitivity under sub-shock conditions is connected to the strength of the weakest covalent bond in the molecule, that is, its “trigger linkage.” These correlations have been observed with different classes of energetic molecules and indicate that “trigger linkage” bond breaking, and heat of explosion are good indicators for the sensitivity trends. Herein we report the synthesis of aliphatic energetic materials with ethane, propane and neopentane backbones. Experimental and computational studies show that the trigger linkage model, based on results from quantum molecular dynamics simulations, correctly predicts trends observed in the impact sensitivity of the molecules. However, while the model predicts the impact sensitivities of the ethane series, the neopentane series has higher impact sensitivities than predicted, which is presumably influenced by crystal packing effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Sensitive Volumes Associated with Ion-and Laser-Induced Charge Collection in an Epitaxial Silicon Diode

A sensitive volume is developed using pulsed laser-induced collected charge for two bias conditions in an epitaxial silicon diode. These sensitive volumes show good agreement with experimental two photon absorption laser-induced collected charge at a variety of focal positions and pulse energies. When compared to ion-induced collected charge, the laser-based sensitive volume over predicts the experimental collected charge at low bias and agrees at high bias. Here, a sensitive volume based on ion-induced collected charge adequately describes the ion experimental results at both biases. Differences in the amount of potential modulation explain the differences between the ion-and laser-based sensitive volumes at the lower bias. Truncation of potential modulation by the highly doped substrate at the higher bias results in similar sensitive volumes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

60 APPLIED LIFE SCIENCES↗

Experimental and theoretical studies of the characteristics of position-sensitive photodetectors based on n-CdSe/mica epitaxial layers

The experimental results of studying the output characteristics of four-contact semiconductor position-sensitive photodetectors fabricated on the basis of photosensitive n-CdSe/mica epitaxial layers are presented. The position sensitivity of layers was theoretically analyzed based on elementary current flow theory and the electric dipole model. It is found that the theoretical characteristics of the coordinate sensitivity of the studied position-sensitive photodetectors correlate with the experimental dependences in terms of both curve shape and positions of the maxima. The results of determining the specific spectral sensitivity indicate the prospects for n-CdSe layers as position-sensitive photodetectors.

36 MATERIALS SCIENCE↗

Sensitivity enhancement of grating interferometer based two-dimensional sensor arrays using two-wavelength readout

Diffraction gratings integrated with microelectromechanical systems (MEMS) sensors offer displacement measurements with subnanometer sensitivity. However, the sensitivity of the interferometric readout may drop significantly based on the gap between the grating and the reference surface. A two-wavelength (2-{lambda}) readout method was previously tested using a single MEMS sensor for illustrating increased displacement measurement capability. This work demonstrates sensitivity enhancement on a sensor array with large scale parallelization ({approx}20,000 sensors). The statistical representation, which is developed to model sensitivity enhancement within a grating based sensor array, is supported by experimental results using a thermal sensor array. In the experiments, two lasers at different wavelengths (633 and 650 nm) illuminate the thermal sensor array from the backside, time-sequentially. The diffracted first order light from the array is imaged onto a single CCD camera. The target scene is reconstructed by observing the change in the first diffracted order diffraction intensity for both wavelengths. Merging of the data from two measurements with two lasers was performed by taking the larger of the two CCD measurements with respect to the reference image for each sensor. {approx}30% increase in the average sensitivity was demonstrated for a 160x120 pixel IR sensor array. Proposed architecture is also applicable to a variety of sensing applications, such as parallel biosensing and atomic force microscopy, for improved displacement measurements and enhanced sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MCNP6 Results for the Phase III Sensitivity Benchmark of the OCED/NEA Expert Group on Uncertainty Analysis for Criticality Safety Assessment

Within the last decade, there has been increasing interest in the calculation of cross section sensitivity coefficients of k eff for integral experiment design and uncertainty analysis. The OECD/NEA has an Expert Group devoted to Sensitivity and Uncertainty Analysis within the Working Party for Nuclear Criticality Safety. This expert group has developed benchmarks to assess code capabilities and performance for doing sensitivity and uncertainty analysis. Phase III of a set of sensitivity benchmarks evaluates capabilities for computing sensitivity coefficients. MCNP6 has the capability to compute cross section sensitivities for k eff using continuous-energy physics. To help verify this capability, results for the Phase III benchmark cases are generated and submitted to the Expert Group for comparison. The Phase III benchmark has three cases: III.1, an array of MOX fuel pins, III.2, a series of infinite lattices of MOX fuel pins with varying pitches, and III.3 two spheres with homogeneous mixtures of UF 4 and polyethylene with different enrichments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EUCLID Sensitivity Database

This report documents the EUCLID sensitivity database along with its several use-cases. EUCLID computed sensitivities for the following integral responses: Criticality of ICSBEP critical assemblies, LLNL pulsed-sphere neutron-leakage spectra, reaction rates in selected ICBSEP critical assemblies, delayed neutron factions of selected ICSBEP critical assemblies, reactivity coefficients in two ICSBEP critical assemblies, sub-critical assembly responses and Rossi-alpha of selected critical assemblies. It is described for each response what the reported observable constitutes, the method we used to obtain the sensitivities, and which integral experiments were studied. It is also documented briefly in what format these sensitivities are stored. These sensitivities were used for many aspects of the EUCLID project, like ML-supported large-scale nuclear-data validation, or optimization of integral experiments. But these sensitivities can also be applied for more established processes in the nuclear-data application field such as adjustment or assessing the upper sub-critical limit.

Delayed Neutron Fraction↗

Numerical Modeling of Anisotropic Elastic-Wave Sensitivity Propagation for Optimal Design of Time-Lapse Seismic Surveys

Reliable subsurface time-lapse seismic monitoring is crucial for many geophysical applications, such as enhanced geothermal system characterization, geologic carbon utilization and storage, and conventional and unconventional oil/gas reservoir characterization, etc. In this work, we develop an elastic-wave sensitivity propagation method for optimal design of cost-effective time-lapse seismic surveys considering the fact that most of subsurface geologic layers and fractured reservoirs are anisotropic instead of isotropic. For anisotropic media, we define monitoring criteria using qP- and qS-wave sensitivity energies after decomposing qP- and qS-wave components from the total elastic-wave sensitivity wavefield using a hybrid time- and frequency-domain approach. Geophones should therefore be placed at locations with significant qP- and qS-wave sensitivity energies for cost-effective time-lapse seismic monitoring in an anisotropic geology setting. Our numerical modeling results for a modified anisotropic Hess model demonstrate that, compared with the isotropic case, subsurface anisotropy changes the spatial distributions of elastic-wave sensitivity energies. Consequently, it is necessary to consider subsurface anisotropies when designing the spatial distribution of geophones for cost-effective time-lapse seismic monitoring. This finding suggests that it is essential to use our new anisotropic elastic-wave sensitivity modeling method for optimal design of time-lapse seismic surveys to reliably monitor the changes in subsurface reservoirs, fracture zones or target monitoring regions.

97 MATHEMATICS AND COMPUTING↗

Short ensembles: An Efficient Method for Discerning Climate-relevant Sensitivities in Atmospheric General Circulation Models

This paper explores the feasibility of an experimentation strategy for investigating sensitivities in fast components of atmospheric general circulation models. The basic idea is to replace the traditional serial-in-time long-term climate integrations by representative ensembles of shorter simulations. The key advantage of the proposed method lies in its efficiency: since fewer days of simulation are needed, the computational cost is less, and because individual realizations are independent and can be integrated simultaneously, the new dimension of parallelism can dramatically reduce the turnaround time in benchmark tests, sensitivities studies, and model tuning exercises. The strategy is not appropriate for exploring sensitivity of all model features, but it is very effective in many situations. Two examples are presented using the Community Atmosphere Model version 5. The first example demonstrates that the method is capable of characterizing the model cloud and precipitation sensitivity to time step length. A nudging technique is also applied to an additional set of simulations to help understand the contribution of physics-dynamics interaction to the detected time step sensitivity. In the second example, multiple empirical parameters related to cloud microphysics and aerosol lifecycle are perturbed simultaneously in order to explore which parameters have the largest impact on the simulated global mean top-of-atmosphere radiation balance. Results show that in both examples, short ensembles are able to correctly reproduce the main signals of model sensitivities revealed by traditional long-term climate simulations for fast processes in the climate system. The efficiency of the ensemble method makes it particularly useful for the development of high-resolution, costly and complex climate models.

atmospheric general circulation models↗

Inhomogeneous Forcing and Transient Climate Sensitivity

Understanding climate sensitivity is critical to projecting climate change in response to a given forcing scenario. Recent analyses have suggested that transient climate sensitivity is at the low end of the present model range taking into account the reduced warming rates during the past 10-15 years during which forcing has increased markedly. In contrast, comparisons of modelled feedback processes with observations indicate that the most realistic models have higher sensitivities. Here I analyse results from recent climate modelling intercomparison projects to demonstrate that transient climate sensitivity to historical aerosols and ozone is substantially greater than the transient climate sensitivity to CO2. This enhanced sensitivity is primarily caused by more of the forcing being located at Northern Hemisphere middle to high latitudes where it triggers more rapid land responses and stronger feedbacks. I find that accounting for this enhancement largely reconciles the two sets of results, and I conclude that the lowest end of the range of transient climate response to CO2 in present models and assessments (less than 1.3 C) is very unlikely.

sensitivity↗

Sensitivity Analysis of the Human Research Program’s Impact 1.0 Model

Sensitivity analysis estimates the relative contribution of the uncertainty in input values to the uncertainty of model outputs. Partial Rank Correlation Coefficient (PRCC) and Leave One Out (LOO) are methods of conducting sensitivity analysis on non-linear simulation models like the IMPACT Model. The PRCC method estimates the sensitivity using partial correlation of the ranks of the generated input values to each generated output value. The “partial” part is due to the adjustments made for the linear effects of all the other input values in the calculation of correlation between a particular input and each output. LOO removes a medical condition from test suite and calculates the change in the outcome. This is used to identify the influence of the condition input in the model The inputs to the sensitivity procedures include the number of occurrences of each of the one hundred plus IMPACT medical conditions generated over the simulations, and the IMPACT outputs from the MEDPRAT mathematical model. The outputs total task time lost (TTL), number of return to definitive care (RTDC), and number of loss of crew lives (LOCL). The IMPACT team will report the results of using PRCC and LOO on IMPACT 1.0. Tornado plots will assist in the visualization of the condition-related input sensitivities to each of the main outcomes. The outcomes of this sensitivity analysis will drive review focus by identifying conditions where changes in uncertainty, and input values could drive changes in overall model output uncertainty. These efforts are an integral part of the overall verification, validation, and credibility review of IMPACT 1.0.

Sensitivity Anaylsis↗

Sensitivity Study of Impact Risk Model Results to Thermal Radiation Damage Model for Large Objects

NASA’s Probabilistic Asteroid Impact Risk (PAIR) assessment model assesses the likelihood of potential damage for asteroid impact scenarios. Fast-running models are used to capture the effects of different hazards. This paper looks specifically at local ground damage hazards, including blast overpressure and thermal radiation damage, for large object impact scenarios. A sensitivity study is conducted to determine which parameters, and over what ranges, cause impact risks to become sensitive to thermal damage. Two additional thermal models with different approaches are used for comparison. The study determined the current thermal model is most sensitive to the luminous efficiency parameter that reflects the model’s uncertainty in the amount of energy contributing to the thermal radiation damage. This sensitivity was most apparent for the highest severity damage levels. Comparisons of the three models showed that in addition to sensitivities within the models, the impact risks are also sensitive to the choice of thermal model. The study results were applied to the 2023 PDC hypothetical asteroid impact scenario and parameter ranges of interest determined. At the serious damage level, luminous efficiencies above 0.006 showed a small chance of thermal playing an important role, while luminous efficiencies above 0.0008 led to thermal playing a significant role at the unsurvivable damage severity level. Study results are used to identify key areas where additional model refinement and better knowledge of asteroid properties may be important for improving damage estimates.

SMD↗

Sensitivity Study of Impact Risk Model Results to Thermal Radiation Damage Model for Large Objects

NASA’s Probabilistic Asteroid Impact Risk (PAIR) assessment model assesses the likelihood of potential damage for asteroid impact scenarios. Fast-running models are used to capture the effects of different hazards. This paper looks specifically at local ground damage hazards, including blast overpressure and thermal radiation damage, for large object impact scenarios. A sensitivity study is conducted to determine which parameters, and over what ranges, cause impact risks to become sensitive to thermal damage. Two additional thermal models with different approaches are used for comparison. The study determined the current thermal model is most sensitive to the luminous efficiency parameter that reflects the model’s uncertainty in the amount of energy contributing to the thermal radiation damage. This sensitivity was most apparent for the highest severity damage levels. Comparisons of the three models showed that in addition to sensitivities within the models, the impact risks are also sensitive to the choice of thermal model. The study results were applied to the 2023 Planetary Defense Conference hypothetical asteroid impact scenario and parameter ranges of interest determined. At the serious damage level, luminous efficiencies above 0.006 showed a small chance of thermal playing an important role, while luminous efficiencies above 0.0008 led to thermal playing a significant role at the unsurvivable damage severity level. Study results are used to identify key areas where additional model refinement and better knowledge of asteroid properties may be important for improving damage estimates.

SMD↗

Monochromatic wavelength dispersive x-ray fluorescence providing sensitive and selective detection of uranium

Monochromatic wavelength dispersive X-ray fluorescence (MWDXRF) is a sensitive and selective method for elemental compositional analyses. The basis for this instrumental advance is the doubly curved crystal (DCC) optic. Previous work has demonstrated the feasibility of sensitive trace element detection for yttrium as a surrogate for curium in aqueous solutions. Additional measurements have demonstrated similar sensitivity in several different matrix environments which attests to the selectivity of the DCC optic as well as the capabilities of the MWDXRF concept. The objective of this effort is to develop an improved Pu characterization method for nuclear fuel reprocessing plants. The MWDXRF prototype instrument is the second step in a multi-year effort to achieve an improved Pu assay. This work will describe a prototype MWDXRF instrument designed for uranium detection and characterization. The prototype consists of an X-ray tube with a rhodium anode and a DCC excitation optic incorporated into the source. The DCC optic passes the RhK{alpha} line at 20.214 keV for monochromatic excitation of the sample. The source is capable of 50 W power at 50 kV and 1.0 mA operation. The x-ray emission from the sample is collected by a DCC optic set at the UL{alpha} line of 13.613 keV. The collection optic transmits the UL{alpha} x-rays to the silicon drift detector. The x-ray source, sample, collection optic and detector are all mounted on motion controlled stages for the critical alignment of these components. The sensitivity and selectivity of the instrument is obtained through the monochromatic excitation and the monochromatic detection. The prototype instrument performance has a demonstrated for sensitivity for uranium detection of around 2 ppm at the current state of development. Further improvement in sensitivity is expected with more detailed alignment.

47 OTHER INSTRUMENTATION↗

Scale/TSUNAMI Sensitivity Data for ICSBEP Evaluations

The Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI) software developed at Oak Ridge National Laboratory (ORNL) as part of the Scale code system provide unique methods for code validation, gap analysis, and experiment design. For TSUNAMI analysis, sensitivity data are generated for each application and each existing or proposed experiment used in the assessment. The validation of diverse sets of applications requires potentially thousands of data files to be maintained and organized by the user, and a growing number of these files are available through the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE) distributed through the International Criticality Safety Benchmark Evaluation Program (ICSBEP). To facilitate the use of the IHECSBE benchmarks in rigorous TSUNAMI validation and gap analysis techniques, ORNL generated SCALE/TSUNAMI sensitivity data files (SDFs) for several hundred benchmarks for distribution with the IHECSBE. For the 2010 edition of IHECSBE, the sensitivity data were generated using 238-group cross-section data based on ENDF/B-VII.0 for 494 benchmark experiments. Additionally, ORNL has developed a quality assurance procedure to guide the generation of Scale inputs and sensitivity data, as well as a graphical user interface to facilitate the use of sensitivity data in identifying experiments and applying them in validation studies.