Search NASA⌕ Search

SEARCH · Search NASA

Results for “Simulation science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Grain incompatibility determines the local structure of amorphous grain boundary complexions

Amorphous grain boundary complexions lack long-range crystalline order but are not featureless, as distinct gradients in structural short-range order have been reported through their thickness. In this work, we test the hypothesis that the distribution of short-range order is determined by the confining crystals using atomistic simulations of both Cu-Zr bicrystals and a random polycrystal. Voronoi polyhedra with structures similar to that of perfect face-centered cubic serve as signatures of high structural order and are only found at the amorphous-crystalline transition regions. The density of the ordered structural motifs within a specific amorphous-crystalline transition region is found to not be directly determined by the orientation and symmetry of the grain which touches it, but rather by the incompatibility between the two confining grains. Further, ordered polyhedra density is found to be inversely related to grain incompatibility, meaning that large incompatibilities between the confining crystals lead to less order in the amorphous-crystalline transition region. The finding that the entire grain-film-grain system must be considered to understand local structure unequivocally demonstrates that amorphous complexions are not simply a collection of independent phases which happen to nucleate at a grain boundary. Rather, an amorphous grain boundary complexion is a single entity that finds a local equilibrium configuration.

36 MATERIALS SCIENCE↗

Control of the hierarchical assembly of π-conjugated optoelectronic peptides by pH and flow

Self-assembled nanoaggregates of p-conjugated peptides possess optoelectronic properties due to electron delocalization over the conjugated peptide groups that make them attractive candidates for the fabrication of bioelectronic materials. We present a computational and theoretical study to resolve the microscopic effects of pH and flow on the non-equilibrium morphology and kinetics of early-stage assembly of an experimentally-realizable optoelectronic peptide that displays pH triggerable assembly. Employing coarse-grained molecular dynamics simulations, we probe the effects of pH on growth kinetics and aggregate morphology to show that control of the peptide protonation state by pH can be used to modulate the assembly rates, degree of molecular alignment, and resulting morphologies within the self-assembling nanoaggregates. We also quantify the time and length scales at which convective flows employed in directed assembly compete with microscopic diffusion to show that flow influences cluster alignment and assembly rate during early-stage assembly only at extremely high shear rates. This suggests that observed improvements in optoelectronic properties at experimentally-accessible shear rates are due to the alignment of large aggregates of hundreds of monomers on time scales in excess of hundreds of nanoseconds. Lastly, our work provides new fundamental understanding of the effects of pH and flow to control the morphology and kinetics of early-stage assembly of p-conjugated peptides and lays the groundwork for the rational manipulation of environmental conditions to direct assembly and the attendant emergent optoelectronic properties.

36 MATERIALS SCIENCE↗

Simulation of the ohmic loss in photovoltaic laser-power converters for wavelengths of 809 and 1064 nm

The method of mathematical simulation is used to examine the influence exerted by the characteristics of the epitaxial structure and contact grid of photovoltaic laser-power converters on their ohmic loss. The maximum attainable photoconverter efficiency at a Gaussian distribution of the laser-beam intensity on the surface of a photovoltaic converter and at dark-current densities of p–n junctions typical of structures grown by the metal-organic vapor-phase epitaxy (MOVPE) technique are determined. An approach to finding the optimal parameters of GaAs and In{sub 0.24}Ga{sub 0.76}As/GaAs photovoltaic converters in relation to the optical power being converted is suggested, and the structural parameters for incident-power values of 5, 20, and 50 W at wavelengths of 809 and 1064 nm are determined. It is found that, at laser-light intensities of up to 5 W, >60% efficiency can be achieved in laser-light conversion at a wavelength of 809 nm and >55% efficiency, at a wavelength of 1064 nm.

36 MATERIALS SCIENCE↗

Short-wavelength-sensitive 2 (Sws2) visual photopigment models combined with atomistic molecular simulations to predict spectral peaks of absorbance

For many species, vision is one of the most important sensory modalities for mediating essential tasks that include navigation, predation and foraging, predator avoidance, and numerous social behaviors. The vertebrate visual process begins when photons of the light interact with rod and cone photoreceptors that are present in the neural retina. Vertebrate visual photopigments are housed within these photoreceptor cells and are sensitive to a wide range of wavelengths that peak within the light spectrum, the latter of which is a function of the type of chromophore used and how it interacts with specific amino acid residues found within the opsin protein sequence. Minor differences in the amino acid sequences of the opsins are known to lead to large differences in the spectral peak of absorbance (i.e. the λ max value). In our prior studies, we developed a new approach that combined homology modeling and molecular dynamics simulations to gather structural information associated with chromophore conformation, then used it to generate statistical models for the accurate prediction of λ max values for photopigments derived from Rh1 and Rh2 amino acid sequences. In the present study, we test our novel approach to predict the λ max of phylogenetically distant Sws2 cone opsins. To build a model that can predict the λ max using our approach presented in our prior studies, we selected a spectrally-diverse set of 11 teleost Sws2 photopigments for which both amino acid sequence information and experimentally measured λ max values are known. The final first-order regression model, consisting of three terms associated with chromophore conformation, was sufficient to predict the λ max of Sws2 photopigments with high accuracy. This study further highlights the breadth of our approach in reliably predicting λ max values of Sws2 cone photopigments, evolutionary-more distant from template bovine RH1, and provided mechanistic insights into the role of known spectral tuning sites.

59 BASIC BIOLOGICAL SCIENCES↗

Relaxation mechanisms, structure and properties of semi-coherent interfaces

In this work, using the Cu–Ni (111) semi-coherent interface as a model system, we combine atomistic simulations and defect theory to reveal the relaxation mechanisms, structure, and properties of semi-coherent interfaces. By calculating the generalized stacking fault energy (GSFE) profile of the interface, two stable structures and a high-energy structure are located. During the relaxation, the regions that possess the stable structures expand and develop into coherent regions; the regions with high-energy structure shrink into the intersection of misfit dislocations (nodes). This process reduces the interface excess potential energy but increases the core energy of the misfit dislocations and nodes. The core width is dependent on the GSFE of the interface. The high-energy structure relaxes by relative rotation and dilatation between the crystals. The relative rotation is responsible for the spiral pattern at nodes. The relative dilatation is responsible for the creation of free volume at nodes, which facilitates the nodes’ structural transformation. Several node structures have been observed and analyzed. In conclusion, the various structures have significant impact on the plastic deformation in terms of lattice dislocation nucleation, as well as the point defect formation energies.

36 MATERIALS SCIENCE↗

TH-A-18C-11: An Investigation of KV CBCT Image Quality and Dose Reduction for Volume-Of-Interest Imaging Using Dynamic Collimation

Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kV-CBCT using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of one-dimensional translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian OBI system. CBCT and planar image quality was investigated as a function of aperture radius, while maintaining the same dose to the VOI, for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various anatomical sites were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 cm to 2.4 cm (at isocenter). Similarly, this change in iris diameter corresponds to a factor increase of approximately 1.4 and 1.5 in image contrast for CBCT and planar images, respectively, and similarly a factor decrease in image noise of approximately 1.7 and 1.5. This results in a measured gain in contrast-to-noise ratio of a factor of approximately 2.3 for both CBCT and planar images. Depending upon the anatomical site, dose was reduced to 10%–70% of the full field value along the central axis plane and down to 2% along the axial planes, while maintaining the same dose to the VOI compared to full-field techniques. Conclusion: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.

60 APPLIED LIFE SCIENCES↗

Neutron-induced electronic failures around a high-energy linear accelerator

Purpose: After a new in-vault CT-on-rails system repeatedly malfunctioned following use of a high-energy radiotherapy beam, we investigated the presence and impact of neutron radiation on this electronic system, as well as neutron shielding options. Methods: We first determined the CT scanner's failure rate as a function of the number of 18 MV monitor units (MUs) delivered. We then re-examined the failure rate with both 2.7-cm-thick and 7.6-cm-thick borated polyethylene (BPE) covering the linac head for neutron shielding. To further examine shielding options, as well as to explore which neutrons were relevant to the scanner failure, Monte Carlo simulations were used to calculate the neutron fluence and spectrum in the bore of the CT scanner. Simulations included BPE covering the CT scanner itself as well as covering the linac head. Results: We found that the CT scanner had a 57% chance of failure after the delivery of 200 MUs. While the addition of neutron shielding to the accelerator head reduced this risk of failure, the benefit was minimal and even 7.6 cm of BPE was still associated with a 29% chance of failure after the delivery of 200 MU. This shielding benefit was achieved regardless of whether the linac head or CT scanner was shielded. Additionally, it was determined that fast neutrons were primarily responsible for the electronic failures. Conclusions: As illustrated by the CT-on-rails system in the current study, physicists should be aware that electronic systems may be highly sensitive to neutron radiation. Medical physicists should therefore monitor electronic systems that have not been evaluated for potential neutron sensitivity. This is particularly relevant as electronics are increasingly common in the therapy vault and newer electronic systems may exhibit increased sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opening new institutional spaces for grappling with uncertainty: A constructivist perspective

In the context of an increasing reliance on predictive computer simulation models to calculate potential project impacts, it has become common practice in impact assessment (IA) to call on proponents to disclose uncertainties in assumptions and conclusions assembled in support of a development project. Understandably, it is assumed that such disclosures lead to greater scrutiny and better policy decisions. This paper questions this assumption. Drawing on constructivist theories of knowledge and an analysis of the role of narratives in managing uncertainty, I argue that the disclosure of uncertainty can obscure as much as it reveals about the impacts of a development project. It is proposed that the opening up of institutional spaces that can facilitate the negotiation and deliberation of foundational assumptions and parameters that feed into predictive models could engender greater legitimacy and credibility for IA outcomes. - Highlights: Black-Right-Pointing-Pointer A reliance on supposedly objective disclosure is unreliable in the predictive model context in which IA is now embedded. Black-Right-Pointing-Pointer A reliance on disclosure runs the risk of reductionism and leaves unexamined the social-interactive aspects of uncertainty. Black-Right-Pointing-Pointer Opening new institutional spaces could facilitate deliberation on foundational predictive model assumptions.

54 ENVIRONMENTAL SCIENCES↗

Quantum approximate optimization of the long-range Ising model with a trapped-ion quantum simulator

Quantum computers and simulators may offer significant advantages over their classical counterparts, providing insights into quantum many-body systems and possibly improving performance for solving exponentially hard problems, such as optimization and satisfiability. Here, we report the implementation of a low-depth Quantum Approximate Optimization Algorithm (QAOA) using an analog quantum simulator. We estimate the ground-state energy of the Transverse Field Ising Model with long-range interactions with tunable range, and we optimize the corresponding combinatorial classical problem by sampling the QAOA output with high-fidelity, single-shot, individual qubit measurements. We execute the algorithm with both an exhaustive search and closed-loop optimization of the variational parameters, approximating the ground-state energy with up to 40 trapped-ion qubits. We benchmark the experiment with bootstrapping heuristic methods scaling polynomially with the system size. We observe, in agreement with numerics, that the QAOA performance does not degrade significantly as we scale up the system size and that the runtime is approximately independent from the number of qubits. We finally give a comprehensive analysis of the errors occurring in our system, a crucial step in the path forward toward the application of the QAOA to more general problem instances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impacts of anthropogenic aerosols on fog in North China Plain

Fog poses a sever environmental problem in the North China Plain (NCP), China, which has been witnessing increases anthropogenic emission since the early 1980s. Here, this work first uses the WRF/Chem model coupled with the local anthropogenic emissions to simulate and evaluate a severe fog event occurring in NCP. Comparison of the simulations against observations shows that WRF/Chem well reproduces the general features of temporal evolution of PM 2.5 mass concentration, fog spatial distribution, visibility, and vertical profiles of temperature, water vapor content and relative humidity in the planetary boundary layer throughout the whole period of the fog event. Sensitivity studies are then performed with five different levels of anthropogenic emission as model inputs to systematically examine the comprehensive impacts of aerosols on fog microphysical, macrophysical, radiative, and dynamical properties. The results show that as aerosol concentration increases, fog droplet number concentration and liquid water content all increase nonlinearly; but effective radius decreases. Macrophysical properties (fog fraction, fog duration, fog height, and liquid water path) also increase nonlinearly with increasing aerosol concentration, with rates of changes smaller than microphysical properties. Further analysis reveals distinct aerosol effects on thermodynamic and dynamical conditions during different stages of fog evolution: increasing aerosols invigorate fog formation and development by enhancing longwave-induced instability, fog droplet condensation accompanying latent heat release, and thus turbulence, but delay fog dissipation by reducing surface solar radiation, surface sensible and latent heat fluxes, and thus suppressing turbulence during the dissipation stage.

54 ENVIRONMENTAL SCIENCES↗

Thermal instability of silicon fullerenes stabilized with hydrogen: Computer simulation

The structure and kinetic properties of a hollow single-layer fullerene-structured Si{sub 60} cluster are treated theoretically by molecular dynamic simulation in the temperature range 10 K {<=} T {<=} 1760 K. Five series of calculations are conducted, with simulation of several media inside and outside the Si{sub 60} cluster, specifically, vacuum and interior spaces filled with 30 and 60 hydrogen atoms with and without the exterior hydrogen environment of 60 atoms. The average radius of the silicon cluster, R-bar {sub cl}increases with increasing temperature, reaching a maximal value in the absence of hydrogen near the cluster and taking smaller values if the unpaired bonds of silicon atoms are fully compensated with hydrogen atoms located inside the cluster and there is no exterior hydrogen 'coat.' An increase in temperature yields a decrease in the average number of Si-Si bonds per atom in the silicon cluster, n-bar{sub b}, and in the average length L-bar{sub b} of the Si-Si bonds. The higher stability of the quantities n-bar {sub b} and L-bar{sub b} in the entire temperature region under consideration is characteristic of the Si{sub 60} fullerene surrounded by a hydrogen 'coat' and containing 60 hydrogen atoms in the interior space. Such clusters have smaller self-diffusion coefficients at high temperatures. The fullerene stabilized with hydrogen is stable to the formation of linear atomic chains up to the temperatures 270-280 K.

36 MATERIALS SCIENCE↗

Force transduction and lipid binding in MscL: A continuum-molecular approach

The bacterial mechanosensitive channel MscL, a small protein mainly activated by membrane tension, is a central model system to study the transduction of mechanical stimuli into chemical signals. Mutagenic studies suggest that MscL gating strongly depends on both intra-protein and interfacial lipid-protein interactions. However, there is a gap between this detailed chemical information and current mechanical models of MscL gating. Here, we investigate the MscL bilayer-protein interface through molecular dynamics simulations, and take a combined continuum-molecular approach to connect chemistry and mechanics. We quantify the effect of membrane tension on the forces acting on the surface of the channel, and identify interactions that may be critical in the force transduction between the membrane and MscL. We find that the local stress distribution on the protein surface is largely asymmetric, particularly under tension, with the cytoplasmic side showing significantly larger and more localized forces, which pull the protein radially outward. The molecular interactions that mediate this behavior arise from hydrogen bonds between the electronegative oxygens in the lipid headgroup and a cluster of positively charged lysine residues on the amphipathic S1 domain and the C-terminal end of the second trans-membrane helix. We take advantage of this strong interaction (estimated to be 10–13 kT per lipid) to actuate the channel (by applying forces on protein-bound lipids) and explore its sensitivity to the pulling magnitude and direction. We conclude by highlighting the simple motif that confers MscL with strong anchoring to the bilayer, and its presence in various integral membrane proteins including the human mechanosensitive channel K2P1 and bovine rhodopsin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-C-BRD-04: Beam Modeling and Validation with Triple and Double Gaussian Dose Kernel for Spot Scanning Proton Beams

Purpose: To present the validity of our beam modeling with double and triple Gaussian dose kernels for spot scanning proton beams in Nagoya Proton Therapy Center. This study investigates the conformance between the measurements and calculation results in absolute dose with two types of beam kernel. Methods: A dose kernel is one of the important input data required for the treatment planning software. The dose kernel is the 3D dose distribution of an infinitesimal pencil beam of protons in water and consists of integral depth doses and lateral distributions. We have adopted double and triple Gaussian model as lateral distribution in order to take account of the large angle scattering due to nuclear reaction by fitting simulated inwater lateral dose profile for needle proton beam at various depths. The fitted parameters were interpolated as a function of depth in water and were stored as a separate look-up table for the each beam energy. The process of beam modeling is based on the method of MDACC [X.R.Zhu 2013]. Results: From the comparison results between the absolute doses calculated by double Gaussian model and those measured at the center of SOBP, the difference is increased up to 3.5% in the high-energy region because the large angle scattering due to nuclear reaction is not sufficiently considered at intermediate depths in the double Gaussian model. In case of employing triple Gaussian dose kernels, the measured absolute dose at the center of SOBP agrees with calculation within ±1% regardless of the SOBP width and maximum range. Conclusion: We have demonstrated the beam modeling results of dose distribution employing double and triple Gaussian dose kernel. Treatment planning system with the triple Gaussian dose kernel has been successfully verified and applied to the patient treatment with a spot scanning technique in Nagoya Proton Therapy Center.

07 ISOTOPE AND RADIATION SOURCES↗

Size-dependent radiation damage mechanisms in nanowires and nanoporous structures

Nanostructures with a high density of interfaces, such as in nanoporous materials and nanowires, resist radiation damage by promoting the annihilation and migration of defects. This study details the size effect and origins of the radiation damage mechanisms in nanowires and nanoporous structures in model face-centered (gold) and body-centered (niobium) cubic nanostructures using accelerated multi-cascade atomistic simulations and in-situ ion irradiation experiments. Our results reveal three different size-dependent mechanisms of damage accumulation in irradiated nanowires and nanoporous structures: sputtering for very small nanowires and ligaments, the formation and accumulation of point defects and dislocation loops in larger nanowires, and a face-centered-cubic to hexagonal-close-packed phase transformation for a narrow range of wire diameters in the case of gold nanowires. Smaller nanowires and ligaments have a net effect of lowering the radiation damage as compared to larger wires that can be traced back to the fact that smaller nanowires transition from a rapid accumulation of defects to a saturation and annihilation mechanism at a lower dose than larger nanowires. These irradiation damage mechanisms are accompanied with radiation-induced surface roughening resulting from defect-surface interactions. Comparisons between nanowires and nanoporous structures show that the various mechanisms seen in nanowires provide adequate bounds for the defect accumulation mechanisms in nanoporous structures with the difference attributed to the role of nodes connecting ligaments in nanoporous structures. Altogether, our results shed light on the compounded, size-dependent mechanisms leading to the radiation resistance of nanowires and nanoporous structures.

36 MATERIALS SCIENCE↗

Structural analysis of WO 3 -TeO 2 glasses by neutron, high energy X-ray diffraction, reverse Monte Carlo simulations and XANES

The structure of WO 3 -TeO 2 glasses containing 15, 20 and 25 mol% WO 3 are studied by neutron diffraction (ND), high energy X-ray diffraction (XRD) and X-ray Absorption Near Edge spectroscopy (XANES). The short-range structural properties of glasses i.e. Te-O and W-O speciation, coordination number distributions, bond-lengths, and the O-Te-O, O-W-O and O-O-O bond angle distributions in the glass network are determined by the Reverse Monte Carlo (RMC) simulations of the ND and XRD data. RMC technique successfully determined all partial pair correlation functions and the coordination number distributions revealed that glass network consists predominantly of TeO 4 and WO 4 units with small amounts of triangular, penta and hexa co-ordinated units. The average W-O and Te-O bond lengths are in the ranges: 1.69-1.75 +/- 0.01 angstrom and 1.99-2.00 +/- 0.01 angstrom respectively. Both W-O and Te-O correlation peaks are asymmetrical, that indicate a distribution of their bond lengths in the respective structural units. The O-Te-O bond angle distribution has a peak at 107 +/- 2 degrees. Similarly the O-W-O bond angle distribution has a peak at 108 +/- 5 degrees. On increasing the WO3 concentration from 15 to 25 mol%, the average Te-O coordination number decreases from 3.80 to 3.61 +/- 0.02 due to the structural transformation: TeO 4 → TeO 3 , similarly the W-O coordination also decreases and is in the range: 3.79-3.67 +/- 0.02. XANES studies found that the oxidation state of Te and W ions in the glasses are 4 + and 6 + respectively.

36 MATERIALS SCIENCE↗

SU-E-T-358: Monte Carlo Dose Calculation of Small Field Electron Beams

Purpose: Dynamic radiotherapy involving electron beams such as Dynamic Electron Arc Radiotherapy (DEAR) requires accurate dose modelling of small field sizes, similar to the requirement of IMRT field on the small photon field. The current commercial electron Monte Carlo algorithms such as eMC v11 in Eclipse were developed for standard field sizes and do not support the planning of dynamic therapy yet. The purpose of this study is to develop a method to accurately model small field electron beam dosimetry using Monte Carlo simulations. Methods: Comparison between eMC, phantom measurements (diode), and Monte Carlo (MC) simulations (BEAMnrc/DOSYZnrc) were performed for a Varian TrueBeam linac. MC simulations utilized Varian TrueBeam phase space files which had been validated in another study. Static single small field was assessed by comparing dose distributions in water for a 16 MeV beam for circular (2 cm diameter) and rectangular (1×10 cm{sup 2}) cut-out. MC was performed with a resolution of 2.5×2.5×2 mm{sup 2} and statistical uncertainty < 4%. The dose distribution was averaged over adjacent bins to improve precision. Depth dose and orthogonal profiles were evaluated. Results: Small field PDDs differ from those with standard cones. For both circular and rectangular cutouts, the difference in range R8 0-R1 0 is less than 2 mm and in dose within 2%. For the orthogonal profiles, field size and penumbra differences were within 1 mm at depth of maximum dose. The eMC displayed a distinctive “step” in the out-field dose profile in disagreement with both measurement and MC results and needs further investigation. Conclusion: MC was able to characterize the small field dosimetry with good agreement with the measurement data, and thus offers the opportunity for treatment planning of dynamic radiotherapy. Analyses for all other electron energies and cut-out sizes are under way and results will be included in the presentation.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-163: A Biomechanical Lung Model for Respiratory Motion Study

Purpose: This work presents a biomechanical model to investigate the complex respiratory motion for the lung tumor tracking in radiosurgery by computer simulation. Methods: The models include networked massspring-dampers to describe the tumor motion, different types of surrogate signals, and the force generated by the diaphragm. Each mass-springdamper has the same mechanical structure and each model can have different numbers of mass-spring-dampers. Both linear and nonlinear stiffness parameters were considered, and the damping ratio was tuned in a range so that the tumor motion was over-damped (no natural tumor oscillation occurs without force from the diaphragm). The simulation was run by using ODE45 (ordinary differential equations by Runge-Kutta method) in MATLAB, and all time courses of motions and inputs (force) were generated and compared. Results: The curvature of the motion time courses around their peaks was sensitive to the damping ratio. Therefore, the damping ratio can be determined based on the clinical data of a high sampling rate. The peak values of different signals and the time the peaks occurred were compared, and it was found that the diaphragm force had a time lead over the tumor motion, and the lead time (0.1–0.4 seconds) depended on the distance between the tumor and the diaphragm. Conclusion: We reported a model based analysis approach for the spatial and temporal relation between the motion of the lung tumor and the surrogate signals. Due to the phase lead of the diaphragm in comparing with the lung tumor motion, the measurement of diaphragm motion (or its electromyography signal) can be used as a beam gating signal in radiosurgery, and it can also be an additional surrogate signal for better tumor motion tracking. The research is funded by the American Cancer Society (ACS) grant. The grant name is: Frameless SRS Based on Robotic Head Motion Cancellation. The grant number is: RSG-13-313-01-CCE.

60 APPLIED LIFE SCIENCES↗

Data Management Challenges of Exascale Scientific Simulations: A Case Study with the Gyrokinetic Toroidal Code and ADIOS

The push towards exascale computing and the recent introduction of multi-petascale supercomputers have enabled science applications to run complex simulations. However, the gap between compute and I/O has grown wider, even as applications seek to generate and persist increasing amounts of data. Optimizing I/O is challenging and remains a bottleneck at scale. In this paper, we present initial I/O performance results of running Gyrokinetic Toroidal Code (GTC) on Summit, a 200 Petaflop system at Oak Ridge National Laboratory. To manage the complex data in GTC, we use ADIOS, an I/O and data management middleware that provides a rich set of APIs to manage and interact with scientific data. We discuss optimizations performed to obtain improvements in I/O performance and identify a set of challenges that will drive the design and development of next generation data management libraries.

Wan, Lipeng↗