At least 487 records · Page 27

Low-loss millimeter-wave resonators with an improved coupling structure

Millimeter-wave superconducting resonators are a useful tool for studying quantum device coherence in a new frequency domain. However, improving resonators is difficult without a robust and reliable method for coupling millimeter-wave signals to 2D structures. We develop and characterize a tapered transition structure coupling a rectangular waveguide to a planar slotline waveguide with better than 0.5 dB efficiency over 14 GHz, and use it to measure ground-shielded resonators in the W band (75–110 GHz). Having decoupled the resonators from radiative losses, we consistently achieve single-photon quality factors above 10 5 , with a two-level-system loss limit above 10 6 , and verify the effectiveness of oxide removal treatments to reduce loss. These values are 4–5 times higher than those previously reported in the W band, and much closer to typical planar microwave resonators. The improved losses demonstrated by these on-chip millimeter-wave devices shed new light on quantum decoherence in a different frequency regime, offer increased selectivity for high-frequency detectors, and enables new possibilities for hybrid quantum experiments integrating millimeter-wave frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization and Optimization of Skipper CCDs for the SOAR Integral Field Spectrograph

We present results from the characterization and optimization of Skipper charge-coupled devices (CCDs) for use in a focal plane prototype for the Southern Astrophysical Research Integral Field Spectrograph (SIFS). We tested eight Skipper CCDs and selected six for SIFS based on performance results. The Skipper CCDs are 6k × 1k, 15 μm pixels, thick, fully depleted, p-channel devices that have been thinned to ~250 μm, backside processed, and treated with an anti-reflective coating. We demonstrate a single-sample readout noise of <4.3 e - rms pixel -1 in all amplifiers. We optimize the readout sequence timing to achieve a readout noise of 0.5 e - rms pixel -1 after 74 non-destructive measurements, which can be accomplished in a region covering 5% of the detector area in a readout time of <4 minutes. We demonstrate single-photon-counting in all 24 amplifiers (four amplifiers per detector) with a readnoise of σ N ~ 0.18 e - rms pixel -1 after N samp = 400 samples, and we constrain the degree of nonlinearity to be ≲1% at low signal levels (0 e - to 50 e - ). Clock-induced charge (CIC) remains an important issue when the Skipper CCD is configured to provide a large full-well capacity. We achieve a CIC rate of <1.45 × 10 -3 e - pixel -1 frame -1 for a full-well capacity of ~900 e - , which increases to a CIC rate of ~3 e - pixel -1 frame -1 for full-well capacities ~40,000-65,000 e - . We also perform conventional CCD characterization measurements such as charge transfer inefficiency (3.44 × 10 -7 on average), dark current (~2 × 10 -4 e - pixel -1 s -1 ), photon transfer curves, cosmetic defects (<0.45% “bad” pixels), and charge diffusion (point-spread function < 7.5 μm) to verify that these properties are consistent with expectations from conventional p-channel CCDs used for astronomy. Furthermore, we provide the first measurements of the brighter-fatter effect and absolute quantum efficiency (≳80% between 450 and 980 nm; ≳90% between 600 and 900 nm) using Skipper CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracing inter-Coulombic decay of molecular dimers

We have conducted an experimental study on the photo double ionization (PDI) of carbon dioxide dimers and oxygen dimers, while focusing on the dissociation dynamics upon single photon absorption. The results in terms of the kinetic energy and angular distributions of the charged particles show unambiguous experimental evidence of intermolecular Coulombic decay (ICD) in carbon dioxide dimers. In the oxygen dimer, the results show that ICD is accompanied by knock-off ionization mechanisms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of the DUNE photodetectors and study of the event burst phenomenon

The Deep Underground Neutrino Experiment (DUNE) is an upcoming neutrino physics experiment that will answer some of the most compelling questions in particle physics and cosmology. The DUNE far detectors employ silicon photomultipliers (SiPMs) to detect light produced by charged particles interacting in a large liquid argon time projection chamber (LArTPC). The SiPMs are photosensors consisting of an array of single-photon avalanche diodes (SPAD) operating in Geiger mode. Their high sensitivity and dynamic range, as well as the possibility to fill large surfaces with high-granularity sensors, makes them an ideal choice for DUNE. An international consortium of research groups is currently engaged in a systematic comparison of the performances of the SiPM models that have been custom developed for DUNE by two manufacturers. Such detailed studies, which include gain measurements and a structure study of the dark count rate at 77 K, are meant to determine the best choice of the photodetection system for DUNE, as well as characterize the response of the chosen detectors for the DUNE simulation. Moreover, an investigation of a newly observed phenomenon, in which quick bursts of tens of events at close range are collected in individual SiPMs, is being carried out, which potentially impacts the design of future models and their implementation in particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of ePixM, a fully-depleted monolithic CMOS active pixel sensor for soft X-ray experiments at LCLS-II

The LCLS-II Free Electron Laser (FEL) will produce X-ray pulses with a repetition rate of up to 1 MHz and energies between 250 eV and 5 keV. Experiments conducted at LCLS-II will require 2D imaging detectors with a unique set of features, such as high-spatial resolution, low-noise performance, high-dynamic range and high-frame rates up to 1 MHz. We present the design of ePixM, a fully-depleted monolithic CMOS detector tailored for soft X-rays applications at high-repetition rates FEL. It consists of an array of 384×192 active pixel sensors, with a pixel size of 50×50 μm 2 and a total sensitive area of 2×1 cm 2 . ePixM has been designed in a 150 nm CMOS technology on high-resistivity substrate to achieve full depletion of the substrate. Each pixel includes a Charge Sensitive Amplifier (CSA) with gain auto-ranging capability and a noise-shaper performing Correlated Double Sampling (CDS). A novel technique named correlated pre-charging removes the excess noise introduced by the gain-switching mechanism. The performance of the design has been evaluated through post-layout simulations. The Equivalent Noise Charge (ENC) of 11.3 electrons enables single-photon detection at X-ray energies down to 250 eV, and the dynamic range exceeds 10 3 photons at 500 eV thanks to the auto-ranging circuitry.

47 OTHER INSTRUMENTATION↗

Multi-Anode Square Microchannel Plate Photomultiplier Tube

Photek has developed a high performance 4096-anode photomultiplier tube using microchannel plates as the gain medium. Additionally, the detector has been designed in a square format to maximise the active area and allow for easy tiling to cover large areas using multiple units. This paper analyses the detector performance in terms of gain and photocathode uniformity, single photon timing accuracy, count rate capability, cross talk and magnetic field susceptibility.

47 OTHER INSTRUMENTATION↗

Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes

Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.

47 OTHER INSTRUMENTATION↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗

Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

Effect of environmental screening and strain on optoelectronic properties of two-dimensional quantum defects

Point defects in hexagonal boron nitride (hBN) are promising candidates as single-photon emitters (SPEs) in nanophotonics and quantum information applications. The precise control of SPEs requires in-depth understanding of their optoelectronic properties. However, how the surrounding environment of host materials, including the number of layers, substrates, and strain, influences SPEs has not been fully understood. Here, in this work, we study the dielectric screening effect due to the number of layers and substrates, and the strain effect on the optical properties of carbon dimer and nitrogen vacancy defects in hBN from first-principles many-body perturbation theory. We report that environmental screening causes a lowering of the quasiparticle gap and exciton binding energy, leading to nearly constant optical excitation energy and exciton radiative lifetime. We explain the results with an analytical model starting from the Bethe–Salpeter equation Hamiltonian with Wannier basis. We also show that optical properties of quantum defects are largely tunable by strain with highly anisotropic response, in good agreement with experimental measurements. Our work clarifies the effect of environmental screening and strain on optoelectronic properties of quantum defects in two-dimensional insulators, facilitating future applications of SPEs and spin qubits in low-dimensional systems.

36 MATERIALS SCIENCE↗

Dispersion-engineered χ(2) nanophotonics: a flexible tool for nonclassical light

Abstract This article reviews recent progress in quasi-phasematched χ ( 2 ) nonlinear nanophotonics, with a particular focus on dispersion-engineered nonlinear interactions. Throughout this article, we establish design rules for the bandwidth and interaction lengths of various nonlinear processes, and provide examples for how these processes can be engineered in nanophotonic devices. In particular, we apply these rules towards the design of sources of non-classical light and show that dispersion-engineered devices can outperform their conventional counterparts. Examples include ultra-broadband optical parametric amplification as a resource for measurement-based quantum computation, dispersion-engineered spontaneous parametric downconversion as a source of separable biphotons, and synchronously pumped nonlinear resonators as a potential route towards single-photon nonlinearities.

Jankowski, Marc (ORCID:0000000318457415)↗

High-frequency gravitational wave detection by the BREAD experiment

The use of experiments searching for light axion dark matter as high-frequency gravitational wave detectors has garnered increasing attention in recent years. We explore the capabilities of the Broadband Reflector Experiment for Axion Detection (BREAD) in probing the GW parameter space and study the directional dependence of its coverage. This detector can investigate frequencies ranging from 0.05 to 200 THz. We find that by employing single photon detectors, BREAD is sensitive to GWs with characteristic strains as low as 10 −21 at 0.1 THz and 10 −25 at 200 THz with a year exposure time, making it competitive with other proposals operating at similar frequencies.

axions↗

Parameter extraction for a SPICE model of an hTron superconducting thermal switch

Efficiently simulating large circuits is crucial to the development of superconducting nanowire-based electronics. However, current simulation tools for this technology are not adapted to the scaling of circuit size and complexity. We focus on the multilayered heater-nanocryotron (hTron), a promising superconducting nanowire-based switch used in applications such as superconducting nanowire single-photon detector readout. Previously, the hTron was modeled using traditional finite-element methods, which fall short in simulating systems at a larger scale. An empirical-based method would be better adapted to this task, enhancing both simulation speed and agreement with experimental data. In this work, we perform switching current and activation delay measurements on 17 hTron devices. We then develop a method for extracting physical fitting parameters used to characterize the devices. We build a SPICE behavioral model that reproduces the static and transient device behavior using these parameters, and validate it by comparing its performance to a model developed in prior work, showing an improvement in simulation time by several orders of magnitude. Furthermore, our model provides circuit designers with a tool to help understand the hTron’s behavior during all design stages, thus enabling broader use of the hTron across various new areas of application.

Caloritronics↗

Direct observation of ion micromotion in a linear Paul trap

In this paper, the first direct observation of micromotion for multiple ions in a laser-cooled trapped ion crystal is discussed along with a novel measurement technique for micromotion amplitude. Micromotion is directly observed using a time-resolving, single-photon sensitive camera that provides both fluorescence and position data for each ion on the nanosecond time scale. Micromotion amplitude and phase for each ion in the crystal is measured which allows this method to be sensitive to tilts and shifts of the ion chain from the null of the radiofrequency quadrupole potential in the linear trap. Spatial resolution makes this micromotion detection technique suitable for complex ion configurations, including two-dimensional geometries. It does not require any additional equipment or laser beams, and the modulation of the cooling lasers or trap voltages is not necessary for detection, as it is in other methods.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-fidelity simultaneous detection of a trapped-ion qubit register

Qubit state detection is an important part of a quantum computation. As number of qubits in a quantum register increases, it is necessary to maintain high fidelity detection to accurately measure the multi-qubit state. Here we present experimental demonstration of high-fidelity detection of a multi-qubit trapped ion register with average single qubit detection error of 4.2(1.5) ppm and a 4-qubit state detection error of 17(2) ppm, limited by the decay lifetime of the qubit, using a novel single-photon-sensitive camera with fast data collection, excellent temporal and spatial resolution, and low instrumental crosstalk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strong-field ionization of water. II. Electronic and nuclear dynamics en route to double ionization

We investigate the role of nuclear motion and strong-field-induced electronic couplings during the double ionization of deuterated water using momentum-resolved coincidence spectroscopy. By examining the three-body dicationic dissociation channel, D$^{+}$/D$^{+}$/O, for both few- and multi-cycle laser pulses, strong evidence for intra-pulse dynamics is observed. The extracted angle- and energy-resolved double ionization yields are compared to classical trajectory simulations of the dissociation dynamics occurring from different electronic states of the dication. In contrast with measurements of single photon double ionization, pronounced departure from the expectations for vertical ionization is observed, even for pulses as short as 10~fs in duration. We outline numerous mechanisms by which the strong laser field can modify the nuclear wavefunction en-route to final states of the dication where molecular fragmentation occurs. Specifically, we consider the possibility of a coordinate-dependence to the strong-field ionization rate, intermediate nuclear motion in monocation states prior to double ionization, and near-resonant laser-induced dipole couplings in the ion. These results highlight the fact that, for small and light molecules such as D$_2$O, a vertical-transition treatment of the ionization dynamics is not sufficient to reproduce the features seen experimentally in the strong field coincidence double-ionization data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Partial-wave decomposition of the Keldysh ionization amplitude

We present an alternative way of calculating the Keldysh amplitude, i.e., the length-gauge form of the ionization amplitude in the strong-field approximation. The amplitude is evaluated exactly by expanding it in Fourier components and partial waves. Comparisons of the semianalytic model predictions with results of ab initio numerical simulations of the time-dependent Schrödinger equation for the interaction of electrons in short-range potentials with intense laser light yield excellent agreement, for wavelengths from the single photon to the multiphoton to the tunneling regime. Specifically, for ionization from initial states with higher angular momentum quantum number, e.g., p states, a significant improvement over predictions based on the popular saddle-point approximation is found. Furthermore, the current model rate allows for interpretation of the strong-field ionization process in terms of multiphoton absorption pathways and angular momentum selection rules.