Search NASA⌕ Search

SEARCH · Search NASA

Results for “Small”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

SU-E-T-323: Dosimetric Evaluation of Small Fields for SBRT Treatment

Purpose: Stereotactic body radiation therapy (SBRT) is commonly employed to treat small targets for effective tumor control with radiation beams of small field sizes. The goal of this work was to evaluate dosimetrically a treatment planning system (TPS) by comparing the calculated dose for SBRT treatment with ion-chamber measurements. Methods: 3D images of a solid-water phantom with a pinpoint ion-chamber (0.015cm3) inside were acquired with a CT scanner. Active volume of the ion-chamber was delineated on CT images. Targets with a diameter of 1.5cm, 2cm, 3cm, 4cm and 5cm were drawn around the chamber. 3DCRT plans were generated for each target size with centrally opened 6MV beams and off-axis beams by changing the isocenter location, respectively, using a TPS with the Analytical Anisotropic Algorithm. A 21iX linear accelerator was employed for plan delivery. The measured and calculated doses were compared. To evaluate the dose calculations in heterogeneity for small fields SBRT treatment, similar plans were also generated and delivered on a heterogeneous thoracic phantom for 5 different size targets in the lung. Results: Dose comparisons between measurements and calculations showed 5.2%, 1.88%, 1.34%, 1.01% and 0.85% difference for SBRT plans with small central axis beams and 0.96%, 0.15%, 0.58%, 0.22% and 0.77% difference for plans with off-axis beams for five different size targets. For the thoracic phantom, the differences on dose between measurements and calculations are bigger, which are 8%, 5.9%, 4.5%, 3.9% and 4.5%, respectively. Conclusion: Dose verification for small fields used in the SBRT treatment has been performed based on ion-chamber measurements in both homogenous and heterogeneous phantoms. More than a 5% difference has been observed in the heterogeneous phantom, especially for very small fields. To meet the ICRU recommendation on a dose difference of no more than 5%, some corrections on the commissioning parameters of the TPS are needed.

60 APPLIED LIFE SCIENCES↗

WE-G-BRD-05: Inline Magnetic Fields Enhance Tumor Dose for Small Lung Cancers

Purpose: To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. Methods: 9 clinical lung plans were recalculated using Monte Carlo methods and external inline (parallel to the beam direction) magnetic fields of 0.5 T, 1.0 T and 3 T were included. Three plans were 6MV 3D-CRT and six were 6MV IMRT. The GTV’s ranged from 0.8 cc to 73 cc, while the PTV ranged from 1 cc to 180 cc. Results: The inline magnetic field has a moderate impact in lung dose distributions by reducing the lateral scatter of secondary electrons and causing a small local dose increase. Superposition of multiple small beams acts to superimpose the small dose increases and can lead to significant dose enhancements, especially when the GTV is low density. Two plans with very small, low mean density GTV’s (<1 cc, ρ(mean)<0.35g/cc) showed uniform increases of 16% and 23% at 1 T throughout the PTV. Three plans with moderate mean density PTV’s (3–13 cc, ρ(mean)=0.58–0.67 g/cc) showed 6% mean dose enhancement at 1 T in the PTV, however not uniform throughout the GTV/PTV. Replanning would benefit these cases. The remaining 5 plans had large dense GTV’s (∼ 1 g/cc) and so only a minimal (<2%) enhancement was seen. In general the mean dose enhancement at 0.5 T was 60% less than 1 T, while 5–50% higher at 3 T. Conclusions: A paradigm shift in the efficacy of small lung tumor radiotherapy is predicted with future inline MRI-linac systems. This will be achieved by carefully taking advantage of the reduction of lateral electronic disequilibrium withing lung tissue that is induced naturally inside strong inline magnetic fields.

60 APPLIED LIFE SCIENCES↗

A Big Problem for Small Earthquakes: Benchmarking Routine Magnitudes and Conversion Relationships with Coda Envelope-Derived Mw in Southern Kansas and Northern Oklahoma

Earthquake magnitudes are widely relied upon measures of earthquake size. Although moment magnitude (M w ) has become the established standard for moderate and large earthquakes, difficulty in reliably measuring seismic moments for small (generally M w <4) earthquakes has meant that magnitudes for these events remain plagued by a patchwork of inconsistent measurement scales. Because of this, magnitudes of small earthquakes and statistics derived from them can be biased. Furthermore, because small earthquakes are much more numerous than large ones, many applications, such as seismic hazard modeling, depend critically on analysis of events characterized by magnitudes other than M w . Therefore, to assess this problem, we apply coda envelope analysis to reliably determine moment magnitudes for a case study of small earthquakes from northern Oklahoma and southern Kansas. Not surprisingly, we find significant differences among M L , m bLg , and M w for M ~2–4 earthquakes examined here. More troublingly, we find that relations designed to convert other magnitudes to M w , which are relied upon for important applications such as seismic hazard analysis, often increase rather than decrease this bias for our dataset. In our case study, we find that converted magnitudes can result in a systematic bias sometimes exceeding 0.5 magnitude units, a difference that typically corresponds to a factor of ~3 in seismicity rate. Moreover, we find a correspondingly large bias in Gutenberg–Richter b-values, controlled primarily by inaccurate magnitude scaling in the conversion relationships. Although this study focuses on a relatively small geographic area, we can expect that similar issues exist with varying severity in other regions. Therefore, magnitudes of small earthquakes and their associated statistics, including seismicity rates and b-values, should be treated with caution.

58 GEOSCIENCES↗

Exploring Uncertainty in Moment Estimation for Small Earthquakes in Southern Nevada Using the Coda Envelope Method

Compiling source parameter estimates for small earthquakes is important both for our understanding of earthquake physics and for accurately assessing earthquake hazard. Reliable source parameter estimates are difficult to achieve for small earthquakes, in part due to our inability to accurately model the relevant physical processes at high frequencies. The coda envelope methodology developed by Mayeda and Walter (1996) and Mayeda et al. (2003) can mitigate this concern and estimate the moment of small earthquakes by determining the parameters that control the shape of the S-wave coda envelope while eliminating path effects by minimizing the scatter between seismic stations. Here, we use an open-source implementation of this technique called the Coda Calibration Tool (CCT; Barno, 2017) to calculate CCT-based moment magnitude estimates of small earthquakes (M L 0–3) in the Rock Valley, Nevada, region within the Nevada National Security Site. The Rock Valley data set is of particular interest because it allows us to explore the changes in uncertainties of the coda calibration method with earthquake size and depth. We found that a consistent linear relationship exists between the local magnitude M L and our coda-derived M w estimates for earthquakes as small as M L 0–3, but that current CCT workflows do not accurately characterize very shallow events. We also demonstrate that the epistemic uncertainty in the apparent stress value assumed by the CCT algorithm can influence magnitude estimates of small earthquakes. In conclusion, these results provide valuable insight into the seismicity of this region, and inform future analysis and modeling efforts for nuclear monitoring and seismic hazard.

58 GEOSCIENCES↗

Environmental Survey Report for ORNL: Small Mammal Abundance and Distribution Survey Oak Ridge National Environmental Research Park 2009 - 2010

This report summarizes a 1-year small mammal biodiversity survey conducted on the Oak Ridge National Environmental Research Park (OR Research Park). The task was implemented through the Oak Ridge National Laboratory (ORNL) Natural Resources Management Program and included researchers from the ORNL Environmental Sciences Division, interns in the Oak Ridge Institute for Science and Education Higher Education Research Experiences Program, and ORNL Environmental Protection Services staff. Eight sites were surveyed reservation wide. The survey was conducted in an effort to determine species abundance and diversity of small mammal populations throughout the reservation and to continue the historical inventory of small mammal presence for biodiversity records. This data collection effort was in support of the approved Wildlife Management Plan for the Oak Ridge Reservation, a major goal of which is to maintain and enhance wildlife biodiversity on the Reservation. Three of the sites (Poplar Creek, McNew Hollow, and Deer Check Station Field) were previously surveyed during a major natural resources inventory conducted in 1996. Five new sites were included in this study: Bearden Creek, Rainy Knob (Natural Area 21), Gum Hollow, White Oak Creek and Melton Branch. The 2009-2010 small mammal surveys were conducted from June 2009 to July 2010 on the Oak Ridge National Environmental Research Park (OR Research Park). The survey had two main goals: (1) to determine species abundance and diversity and (2) to update historical records on the OR Research Park. The park is located on the Department of Energy-owned Oak Ridge Reservation, which encompasses 13,580 ha. The primary focus of the study was riparian zones. In addition to small mammal sampling, vegetation and coarse woody debris samples were taken at certain sites to determine any correlations between habitat and species presence. During the survey all specimens were captured and released using live trapping techniques including Sherman and pitfall traps. In total 227 small mammals representing nine species were captured during the course of the study. The most common species found in the study was the white-footed mouse (Peromyscus leucopus). The least common species found were the deer mouse (Peromyscus maniculatus), meadow jumping mouse (Zapus hudsonius), woodland vole (Microtus pinetorum), and northern short-tailed shrew (Blarina brevicauda).

54 ENVIRONMENTAL SCIENCES↗

Small-Scale Drying: FY2020 Interim Report

This report documents the interim experimental status of small-scale drying tests currently being performed at Pacific Northwest National Laboratory. These small-scale drying tests are to develop the technical bases for sensors, techniques, and approaches that will be used to address the challenges faced when determining moisture content from gas samples taken at the North Anna Nuclear Generating Station for the High Burnup Demonstration Project. Specifically, the purpose of these tests is to support Sandia National Laboratories gas sample methods and analyses through a series of small-scale experiments. Key focus areas include performing tests to: • Correlate sample bottle measurements to in-cask conditions • Estimate the amount of trapped and absorbed water on cask features and surfaces that can contribute to water vapor • Assess the accuracy of the hygrometer used in the measurements under similar conditions • Identify additional methods for measuring humidity in casks easily and accurately using lessons-learned from Sandia National Laboratories, including direct gravimetric and isotopic tracer techniques. To address these topics this report outlines a series of five tests and any data collected to date that were planned for FY 2020 that include 1) humidity measurement method development, 2) gas bottle sampling tests, 3) surface drying tests on cladding, 4) small-scale drying of cladding, and 5) small-scale drying of guide-tube/dashpots. This interim report documents the experimental background, design and progress of these small-scale drying tests. Further data gathered will be summarized in the FY 2021 report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Open Automated Demand Response for Small Commerical Buildings

This report characterizes small commercial buildings by market segments, systems and end-uses; develops a framework for identifying demand response (DR) enabling technologies and communication means; and reports on the design and development of a low-cost OpenADR enabling technology that delivers demand reductions as a percentage of the total predicted building peak electric demand. The results show that small offices, restaurants and retail buildings are the major contributors making up over one third of the small commercial peak demand. The majority of the small commercial buildings in California are located in southern inland areas and the central valley. Single-zone packaged units with manual and programmable thermostat controls make up the majority of heating ventilation and air conditioning (HVAC) systems for small commercial buildings with less than 200 kW peak electric demand. Fluorescent tubes with magnetic ballast and manual controls dominate this customer group's lighting systems. There are various ways, each with its pros and cons for a particular application, to communicate with these systems and three methods to enable automated DR in small commercial buildings using the Open Automated Demand Response (or OpenADR) communications infrastructure. Development of DR strategies must consider building characteristics, such as weather sensitivity and load variability, as well as system design (i.e. under-sizing, under-lighting, over-sizing, etc). Finally, field tests show that requesting demand reductions as a percentage of the total building predicted peak electric demand is feasible using the OpenADR infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Greenhouse Gas Emission Assessments of Solar and Energy Efficiency Improvements at Small Water Resource Recovery Facilities

Small water resource recovery facilities (WRRFs) account for the majority of centralized systems in the world and have higher energy intensities than large facilities. This study compares potential greenhouse gas emission reductions based on on-site solar energy and energy efficiency (E2) improvements made at small WRRFs. Case study data from 31 existing small WRRFs in Nebraska were collected and included 35 site-specific energy efficiency (E2) recommendations and on-site solar renewable energy systems integrated at three facilities, and the data were used to compare the benefits of on-site solar energy and E2 improvements made at small WRRFs. Improvements in E2 (e.g., improved aeration control) presented the largest reduction in emissions per dollar invested. They often exhibited shorter paybacks, with operational changes in aeration strategies showing the highest impact (up to 0.2 kg CO2eq/m3 treated water). On-site solar systems showed the largest net potential for reducing environmental footprint (0.35 kg CO2eq/m3) but often showed the smallest emissions reduction per cost. While the use of both E2 improvements and the integration of on-site solar renewable energy can significantly improve the sustainability of small WRRFs, on-site solar has advantages for small facilities in that it often requires less operational involvement, allows for greater facility resiliency, and presents less uncertainty in terms of environmental benefit.

Thompson, Matthew↗

NASA technology utilization program: The small business market

Technology transfer programs were studied to determine how they might be more useful to the small business community. The status, needs, and technology use patterns of small firms are reported. Small business problems and failures are considered. Innovation, capitalization, R and D, and market share problems are discussed. Pocket, captive, and new markets are summarized. Small manufacturers and technology acquisition are discussed, covering external and internal sources, and NASA technology. Small business and the technology utilization program are discussed, covering publications and industrial applications centers. Observations and recommendations include small business market development and contracting, and NASA management technology.

Vannoy, J. K.↗

A nonlinear fracture mechanics approach to the growth of small cracks

An analytical model of crack closure is used to study the crack growth and closure behavior of small cracks in plates and at notches. The calculated crack opening stresses for small and large cracks, together with elastic and elastic plastic fracture mechanics analyses, are used to correlate crack growth rate data. At equivalent elastic stress intensity factor levels, calculations predict that small cracks in plates and at notches should grow faster than large cracks because the applied stress needed to open a small crack is less than that needed to open a large crack. These predictions agree with observed trends in test data. The calculations from the model also imply that many of the stress intensity factor thresholds that are developed in tests with large cracks and with load reduction schemes do not apply to the growth of small cracks. The current calculations are based upon continuum mechanics principles and, thus, some crack size and grain structure exist where the underlying fracture mechanics assumptions become invalid because of material inhomogeneity (grains, inclusions, etc.). Admittedly, much more effort is needed to develop the mechanics of a noncontinuum. Nevertheless, these results indicate the importance of crack closure in predicting the growth of small cracks from large crack data.

Newman, J. C., Jr.↗

On the use of marker loads and replicas for measuring growth rates for small cracks

The initiation and growth of small cracks (5-500 microns m) from edge notches in 2024-T3 aluminum alloy sheets were studied under constant amplitude loading. Two methods were used to measure crack shape and size. In the first method, striation marker bands were periodically formed along the crack front by interrupting the constant amplitude loading by either an elevated R-ratio load sequence, or by an overload sequence. In the second method, the surface crack length was monitored by taking surface replicas at regular intervals. The marker band techniques did not provide reliable crack length and crack shape information for cracks smaller than 2 mm. The replica technique provided accurate information for surface crack length at all crack lengths, and fracture tests on specimens with small cracks provided crack-shape information. Crack growth rates were plotted against the stress intensity factor ranges. The results exhibited the small crack effect, in that the small cracks grew faster than large cracks at the same stress-intensity factor range. A crack closure model was also used to analyze the growth of small cracks from small (inclusion) defects at the notch surface.

Swain, M. H.↗

Small-scale eruptive filaments on the quiet sun

A study of a little known class of eruptive events on the quiet sun was conducted. All of 61 small-scale eruptive filamentary structures were identified in a systematic survey of 32 days of H alpha time-lapse films of the quiet sun acquired at Big Bear Solar Observatory. When fully developed, these structures have an average length of 15 arc seconds before eruption. They appear to be the small-scale analog of large-scale eruptive filaments observed against the disk. At the observed rate of 1.9 small-scale eruptive features per field of view per average 7.0 hour day, the rate of occurence of these events on the sun were estimated to be greater than 600 per 24 hour day.. The average duration of the eruptive phase was 26 minutes while the average lifetime from formation through eruption was 70 minutes. A majority of the small-scale filamentary sturctures were spatially related to cancelling magnetic features in line-of-sight photospheric magnetograms. Similar to large-scale filaments, the small-scale filamentary structures sometimes divided opposite polarity cancelling fragments but often had one or both ends terminating at a cancellation site. Their high numbers appear to reflect the much greater flux on the quiet sun. From their characteristics, evolution, and relationship to photospheric magnetic flux, it was concluded that the structures described are small-scale eruptive filaments and are a subset of all filaments.

Hermans, Linda M.↗

Impact of small-crack effects on design-life calculations

The potential impact of the observed small-crack-effect in 2024-T3 aluminum alloy on calculated crack-growth lives is described. The significance of the small-crack effect is assessed by comparing lives computed using only large-crack data to those computed using a combined small- and large-crack data base for constant-amplitude (R = -1 and 0) and fighter-wing spectrum loading (FALSTAFF) conditions. Based on the life calculations, the small-crack effect would have no impact on life analyses that assume an initial crack larger than about 0.3 mm; only a small impact on life analyses that assume an initial crack of 0.1 mm; but a large impact on life analyses that assume an initial crack of about 0.01 mm. When small-crack effects are taken into account, fatigue life analyses based solely on crack growth may provide a viable alternative to traditional two-part initiation-plus-crack-growth life analyses.

Phillips, E. P.↗

A search for small solar-system bodies near the earth using a ground-based telescope - Technique and observations

A large, previously undetected flux of small bodies near earth is identified by employing the standard technique of detection of an individual object in two consecutive frames. The observational periods and viewing coordinates for the search for small bodies are presented. A null test is performed in order to further demonstrate that the signatures in the images are not due to instrumental artifacts. The observed fluxes, orbital motions, and radii of the small bodies detected are in agreement with those for the small cometlike objects previously reported. It is pointed out that the radii of the small bodies would be in the range of meters. Since an alternative interpretation of the small bodies is possible, it is suggested that the use of a telescope with larger aperture and/or array detectors with lesser noise levels is necessary to confirm the present observations.

Frank, L. A.↗

Small planetary mission plan: Report to Congress

This document outlines NASA's small planetary projects plan within the context of overall agency planning. In particular, this plan is consistent with Vision 21: The NASA Strategic Plan, and the Office of Space Science and Applications (OSSA) Strategic Plan. Small planetary projects address focused scientific objectives using a limited number of mature instruments, and are designed to require little or no new technology development. Small missions can be implemented by university and industry partnerships in coordination with a NASA Center to use the unique services the agency provides. The timeframe for small missions is consistent with academic degree programs, which makes them an excellent training ground for graduate students and post-doctoral candidates. Because small missions can be conducted relatively quickly and inexpensively, they provide greater opportunity for increased access to space. In addition, small missions contribute to sustaining a vital scientific community by increasing the available opportunities for direct investigator involvement from just a few projects in a career to many.

Source record↗

Fracture mechanics parameters for small fatigue cracks

This paper presents a review of some common small-crack test specimens, the underlying causes of the small-crack effect, and the fracture-mechanics parameters that have been used to correlate or predict their growth behavior. This review concentrates on continuum mechanics concepts and on the nonlinear behavior of small cracks. The paper reviews some stress-intensity factor solutions for small-crack test specimens and develops some simple elastic-plastic J integral and cyclic J integral expressions that include the influence of crack-closure. These parameters were applied to small-crack growth data on two aluminum alloys, and a fatigue life prediction methodology is demonstrated. For these materials, the crack-closure transient from the plastic wake was found to be the major factor in causing the small-crack effect.

Newman, J. C., Jr.↗

Review of modelling small-crack behavior and fatigue-life predictions for aluminum alloys

The small-crack effect, where small fatigue cracks grow faster and at lower stress-intensity factors than large cracks, has been found to be significant for many materials and loading conditions. In this paper, plasticity effects and crack-closure modelling of small fatigue cracks are reviewed. A crack-closure model with a cyclic-plastic-zone-corrected effective stress-intensity factor range (related to the cyclic J-integral) and microstructural data on crack-initiation sites were used to calculate small-crack growth rates and fatigue lives for unnotched and notched specimens made of two aluminum alloys. The crack-closure transient from the plastic wake was shown to be the dominant cause of the small-crack effect and plasticity effects on the cyclic-plastic-zone-corrected stress-intensity factor range were negligible except at extremely high stress levels. Small-crack growth rates and fatigue lives under both constant-amplitude and spectrum loading from tests and analyses agreed well.

CRACK CLOSURE MODELLING↗

A Review Of Modelling Small-Crack Behavior And Fatigue-Life Predictions For Aluminum Alloys

The small-crack effect, where small fatigue cracks grow faster and at lower stress-intensity factors than large cracks, has been found to be significant for many materials and loading conditions. In this paper, plasticity effects and crack-closure modelling of small fatigue cracks are reviewed. A crack-closure model with a cyclic-plastic zone-corrected effective stress-intensity factor range (related to the cyclic J-integral) and microstructural data on crack-initiation sites were used to calculate small-crack growth rates and fatigue lives for unnotched and notched specimens made of two aluminum alloys. The crack-closure transient from the plastic wake was shown to be the dominant cause of the small-crack effect and plasticity effects on the cyclic-plastic zone-corrected stress-intensity factor range were negligible except at extremely high stress levels. Small-crack growth rates and fatigue lives under both constant-amplitude and spectrum loading from tests and analyses agreed well.

Newman, J. C., Jr.↗