Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid State Devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Eye-Safe Lidar

Laser infrared radar (lidar) undergoing development harmless to human eyes, consists almost entirely of solid-state components, and offers high range resolution. Operates at wavelength of about 2 micrometers. If radiation from such device strikes eye, almost completely absorbed by cornea without causing damage, even if aimed directly at eye. Continuous-wave light from laser oscillator amplified and modulated for transmission from telescope. Small portion of output of oscillator fed to single-mode fiber coupler, where mixed with return pulses. Intended for remote Doppler measurements of winds and differential-absorption measurements of concentrations of gases in atmosphere.

Byer, Robert L.↗

Solid State Research

This report covers in detail the research work of the Solid State Division at Lincoln Laboratory for the period 1 May-31 July 1995. The topics covered are: Electrooptical Devices, Quantum Electronics, Materials Research, Submicrometer Technology, High Speed Electronics, Microelectronics, and analog device technology. Funding is provided primarily by the Air Force, with additional Support provided by the Army, ARPA, Navy, BMDO, NASA and NIST.

Shaver, David C.↗

Solid-state switch modeling

A model for predicting voltages and currents of passive loads during turn on and turn off of remote power controllers is presented. The model is concerned with two devices, a five ampere device and a twenty ampere device. The model is presented as a general circuit diagram. The load current is determined by the load parameters and the conditions at switching and the steady state conditions are reached according to time constants determined by the load. The model is used to analyze the turn on and turn off conditions of certain loads including a R-C load and a R-L load.

Raburn, W. D.↗

Dual-function lignin monomers enable high-performance graphene electrodes via interface confinement and proton transfer enhancement

Graphene oxide (GO)-based energy storage faces dual bottlenecks: unsustainable reduction methods and sluggish proton transfer kinetics. Here, we introduce a groundbreaking green strategy using lignin-derived vanillyl alcohol (VA) as a dual-function monomer to simultaneously address these challenges. By thermally annealing GO/VA films at mild temperatures (<100 °C), VA triggers an interface-confined reduction of GO while self-polymerizing into redox-active oligomers (P-VA) that intercalate between graphene layers. This dual role-reducing agent and proton highway enables a 3D conductive network with minimized graphene restacking, abundant redox sites, and rapid H + transport pathways. Density Functional Theory (DFT) reveals how P-VA optimizes proton dynamics, while the resulting rGO-P-VA4-T90 electrode achieves a record volumetric capacitance of 311.1F/cm 3 (777.8F/cm 2 ) and retains 87.8 % capacity after 10,000 cycles. Flexible solid-state supercapacitors deliver 94.2 μWh/cm 2 energy density at 63.8 μW/cm 2 , rivaling state-of-the-art devices. Furthermore, this work redefines sustainable graphene engineering, merging biomass valorization with high-performance energy storage in a scalable, eco-friendly paradigm.

Graphene oxide reduction↗

Epitaxial growth of III-V compounds for electroluminescent light sources

The epitaxial growth techniques used in the fabrication of III-V compound electroluminescent devices are reviewed. Both vapor and liquid phase epitaxial techniques are discussed, including the applications of these techniques to well established materials as well as newer materials. The state of the art of light-emitting devices fabricated from members of the III-V compounds and their solid solutions is also reviewed.

Chu, T. L.↗

Diode laser-pumped solid-state lasers

Recently, interest in diode laser-pumped solid-state lasers has increased due to their advantages over flashlamp-pumped solid-state lasers. A historical overview is presented of semiconductor diode-pumped solid-state lasers beginning with work in the early 1960s and continuing through recent work on wavelength extension of these devices by laser operation on new transitions. Modeling of these devices by rate equations to obtain expressions for threshold, slope efficiency, and figures of merit is also given.

Fan, Tso Yee↗

Nasicon dual ion conductors for all solid-state batteries

A super ion conductor composition is disclosed. The super ion conductor composition has the general formula: A 1+x M x/2 Zr 2−x/2 (PO 4 ) 3 , where each A is independently Na or Li, M is Mn or Mg, and subscript x is from 0.5 to 3. A solid electrolyte comprising the super ion conductor composition, and a method of preparing the solid electrolyte, are also disclosed. The method comprises combining a zirconium compound, a manganese or magnesium compound, a sodium compound, and a phosphate compound to give a mixture; and calcining the mixture to give the super ion conductor composition, thereby preparing the solid electrolyte. Functional materials and devices comprising the super ion conductor composition are also disclosed, including a catholyte composition, an ion conducting solid electrolyte membrane, as well as all-solid-state batteries.

Amin, Ruhul↗

Solid state switch panel

An intensive study of various forms of transducers was conducted with application towards hermetically sealing the transducer pick off and all electronics. The results indicated that the Hall effect devices and a LED/phototransistor combination were the most practical for this type of application. Therefore, hardware was developed utilizing a magnet/Hall effect transducer for single action switches and LED/phototransistor transducers for rotary multiposition or potentiometer applications. A number of switches were built and models were hermetically sealed to prove the feasibility of this type of fabrication. One of each type of switch was subjected to temperature cycling, vibration, and EMI tests.

Beenfeldt, E.↗

Field ionization device used for measuring the pulse height defect of He/+/ in silicon

A neutral particle detector using field ionization and liquid-nitrogen-cooled solid state detectors has been developed to investigate the pulse height defect of low energy He(+) ions in silicon. The field ionization tip is fabricated from a short length of tungsten wire; a typical detector is of the surface-barrier Si type with a thin Au window and low capacitance (about 15 pF); the assembly is mounted in a cylindrical vacuum chamber which is pumped to about 10 to the -6th torr. As an example, pulse height distributions for He(+) and H(+) taken at tip bias of 25.7 kV are presented. The detected energy of the H and He ions are studied as a function of the actual energies of accelerated ions, for a detector having a gold front conducting surface layer of 32 micrograms/sq cm.

Curtis, C. C.↗

Solid state switch panel

An intensive study of various forms of transducers was conducted with application towards hermetically sealing the transducer and all electronics. The results of the study indicated that the Hall effect devices and a LED/phototransistor combination were the most practical for this type of application. Therefore, hardware was developed utilizing a magnet/Hall effect transducer for single action switches and LED/phototransistor transducers for rotary multiposition or potentiometer applications. All electronics could be housed in a hermetically sealed compartment. A number of switches were built and models were hermetically sealed to prove the feasibility of this type of fabrication. One of each type of switch was subjected to temperature cycling, vibration, and EMI tests. The results of these tests are presented.

Beenfeldt, E.↗

Design and Testing of a Small Inductive Pulsed Plasma Thruster

The design and testing of a small inductive pulsed plasma thruster (IPPT), shown in Fig. 1 with all the major subsystems required for a thruster of this kind are described. Thrust measurements and imaging of the device operated in rep-rated mode are presented to quantify the performance envelope of the device. The small IPPT described in this paper was designed to serve as a test-bed for the pulsed gas-valves and solid-state switches required for a IPPTs. A modular design approach was used to permit future modifications and upgrades. The thruster consists of the following sub-systems: a) a multi-turn, spiral-wound acceleration coil (27 cm o.d., 10 cm i.d.) driven by a 10 microFarad capacitor and switched with a high-voltage thyristor, b) a fast pulsed gas-valve, and c.) a glow-discharge pre-ionizer (PI) circuit. The acceleration-coil circuit may be operated at voltages up to 4 kV (the thyristor limit is 4.5 kV). The device may be operated at rep-rates up to 30 Hz with the present gas-valve. Thrust measurements and imaging of the device operated in rep-rated mode will be presented. The pre-ionizer consists of a 0.3 microFarad capacitor charged to 4 kV and connected to two annular stainless-steel electrodes bounding the area of the coil-face. The 4 kV potential is held across them and when the gas is puffed in over the coil, the PI circuit is completed, and a plasma is formed. Even at the less than optimal base-pressure in the chamber (approximately 5 × 10(exp −4) torr), the PI held-off the applied voltage, and only discharged upon command. For a capacitor charge of 2 kV the peak coil current is 4.1 kA, and during this pulse a very bright discharge (much brighter than from the PI alone) was observed (see Fig. 2). Interestingly, for discharges at this charge voltage the PI was not required as the current rise rate, dI/dt, of the coil itself was sufficient to ionize the gas.

Martin, Adam K.↗

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The information systems heritage

This paper addresses key developments in the evolution of information systems over the past five decades. Major areas covered include the growth of imaging sensors from such pioneering devices as the iconoscope and orthicon which ushered in television, through a wide range of vidicon tubes, to the solid-state arrays which characterize current systems; the phenomenal expansion of electronic communications from telegraph and telephone wires, through the introduction of broadcast and microwave relay services, to the present era of worldwide satellite communications and data networks; and the key role of digital computers from their ancient precursors like the abacus and the mechanical calculating engines, through the appearance of the first large-scale electronic computers and their transistorized successors, to the rapid proliferation of miniaturized processors which impact every aspect of aerospace systems today.

Kurzhals, P. R.↗

Advanced technology for earth observation - Data processing

The Experimental Land Observing System (ELOS) is to demonstrate major advances in space-based land observation. Program success will depend upon successful demonstration of both space-segment performance and ground-system capabilities. Increases in data-rate, volume, and processing requirements present substantial challenges to the ground data processing system. ELOS is based on the utilization of the multispectral linear array (MLA) sensor, a solid-state, electronically scanned instrument. Current MLA instrument designs offer a number of capabilities beyond those provided in the Landsat imaging devices. These capabilities include greater resolution, inherent registration, onboard calibration, off-nadir pointing capability, and fore/aft pointing capability. The proposed MLA flight mission scenario will be one of continued growth and will include flights on the Space Transportation System. Attention is also given to ground-to-ground data transport, data capture, and the use of high speed computers.

Heffner, P.↗

A 20-GHz IMPATT transmitter

The engineering development of a solid state transmitter amplifier operating in the 20 GHz frequency band. The development effort involved a variety of disciplines including IMPATT device development, circulator design, simple and multiple diode circuits designs, and amplifier integration and test.

Chan, J. L.↗