Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Anatomy of Protein Electrospray Ionization Mass Spectra by Superconducting Tunnel Junction Mass and Energy Spectrometry

Cryogenic superconducting tunnel junction (STJ) detectors have the advantage of single-particle sensitivity, high quantum efficiency, low noise, and the ability to detect the time and relative impact energy of deposited ions. This makes them attractive for use in mass spectrometry (MS) and as a form of energy spectrometry. STJ cryodetectors have been coupled to time-offlight (TOF) mass spectrometers equipped with a matrix-assisted laser desorption ionization (MALDI) source and to an electrospray ionization (ESI) TOF mass spectrometer. Here, a lab-made linear ion trap (LIT) mass spectrometer system was coupled to an ESI source and a 16-channel Nb-STJ array with improved readout electronics. The goal was to investigate fundamentals of ESI-generated protein ions by further exploiting the advantage of resolving these ions in a third dimension of the relative energy deposited into the STJs. The proteins equine cytochrome c, bovine carbonic anhydrase, bovine serum albumin, and murine immunoglobulin G were studied using this ESI-LIT-STJ-MS instrument. Multiply charged monomers, multimers, and fragments from metastable ions were resolved from monomer peaks by differences in ion deposition energy even when these ions have the same mass-to-charge ratio as the corresponding monomer. The determination of fragment mass from metastable decomposition is accomplished without knowing the charge state of the fragment. The average charge state of the multimers is reduced with each addition of a protein which is a direct reflection of the surface area available for charging. Multiply charged in-source fragments have also been observed and distinguished in the mass spectrum of carbonic anhydrase by using the differences in the energy deposited in the STJs.

42 ENGINEERING↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Covalent Drug Binding in Live Cells Monitored by Mid-Infrared Quantum Cascade Laser Spectroscopy: Photoactive Yellow Protein as a Model System

The detection of drug-target interactions in live cells enables analysis of therapeutic compounds in a native cellular environment. Recent advances in spectroscopy and molecular biology have facilitated the development of genetically encoded vibrational probes like nitriles that can sensitively report on molecular interactions. Nitriles are powerful tools for measuring electrostatic environments within condensed media like proteins, but such measurements in live cells have been hindered by low signal-to-noise ratios. In this study, we design a spectrometer based on a double-beam quantum cascade laser (QCL)-based transmission infrared (IR) source with balanced detection that can significantly enhance sensitivity to nitrile vibrational probes embedded in proteins within cells compared to a conventional FTIR spectrometer. Here, using this approach, we detect small-molecule binding in Escherichia coli, with particular focus on the interaction between para-Coumaric acid (pCA) and nitrile-incorporated photoactive yellow protein (PYP). This system effectively serves as a model for investigating covalent drug binding in a cellular environment. Notably, we observe large spectral shifts of up to 15 cm –1 for nitriles embedded in PYP between the unbound and drug-bound states directly within bacteria, in agreement with observations for purified proteins. Such large spectral shifts are ascribed to the changes in the hydrogen-bonding environment around the local environment of nitriles, accurately modeled through high-level molecular dynamics simulations using the AMOEBA force field. Our findings underscore the QCL spectrometer’s ability to enhance sensitivity for monitoring drug–protein interactions, offering new opportunities for advanced methodologies in drug development and biochemical research.

chromophores↗

Mapping canopy traits over Québec using airborne and spaceborne imaging spectroscopy

Abstract The advent of new spaceborne imaging spectrometers offers new opportunities for ecologists to map vegetation traits at global scales. However, to date most imaging spectroscopy studies exploiting satellite spectrometers have been constrained to the landscape scale. In this paper we present a new method to map vegetation traits at the landscape scale and upscale trait maps to the continental level, using historical spaceborne imaging spectroscopy (Hyperion) to derive estimates of leaf mass per area, nitrogen, and carbon concentrations of forests in Québec, Canada. We compare estimates for each species with reference field values and obtain good agreement both at the landscape and continental scales, with patterns consistent with the leaf economic spectrum. By exploiting the Hyperion satellite archive to map these traits and successfully upscale the estimates to the continental scale, we demonstrate the great potential of recent and upcoming spaceborne spectrometers to benefit plant biodiversity monitoring and conservation efforts.

54 ENVIRONMENTAL SCIENCES↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

A new class of variable-radii diffraction optics for high-resolution x-ray spectroscopy at the National Ignition Facility (invited)

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

47 OTHER INSTRUMENTATION↗

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

A platform for non-local thermodynamic equilibrium atomic physics research using the buried layer target approach at a kJ level laser facility

Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.

3D printing↗

The inertial confinement fusion experimental platform and diagnostics for studies of nuclear reactions relevant to nuclear astrophysics

High energy density plasmas generated in laser-driven inertial confinement fusion implosions provide unparalleled laboratory conditions for studying stellar-relevant nuclear reactions: plasma environment; hot and dense; uniquely high achievable neutron flux. These experiments have the potential to address long-standing questions about plasma effects on nuclear reactions hitherto experimentally inaccessible, including nuclear rates with thermally distributed reactants, plasma screening, and reactions involving nuclei in excited states. The National Ignition Facility (NIF) and OMEGA lasers are two primary facilities for executing experiments of this type. Existing and future nuclear diagnostics, along with supporting diagnostics to characterize the platform, enable exploitation of these plasmas for such nuclear astrophysics-relevant experiments. Here, this review describes the nuclear diagnostic capabilities currently available for these types of experiments at the NIF and OMEGA, including neutron time-of-flight spectrometers, charged-particle detectors, gamma detectors and radiochemistry diagnostics, and briefly summarizes other available diagnostic capabilities used for platform characterization. Enabling tools not yet available are also identified, including a rapid radioactive sample retrieval system, a low-energy neutron spectrometer and a high-efficiency gamma spectrometer.

National Ignition Facility↗

The meV-resolved Inelastic X-ray Scattering Beamline at NSLS-II: Design and Performance

The ultrahigh resolution inelastic X-ray scattering (IXS) beamline at NSLS-II is designed and built to achieve sub-meV resolution at a moderate energy of 9.13 keV for IXS experiments with high momentum resolution and high spectral contrast. The key instrument is a novel spectrometer featuring a new type of analyzer optics, which combines post-sample collimation with angular dispersive crystal optics. As the first user instrument of its kind, the spectrometer has demonstrated unique research capabilities in exploring low momentum transfer (Q), THz dynamics in soft material systems characterized by mesoscopic heterogeneity and complexity, such as liquid crystals and bio-membranes. Ongoing efforts to improve performance since the start of user operations have resulted in a state-of-the-art energy resolution in routine operations of less than 1.4 meV, with sharp Gaussian-like tails, making it a premier IXS spectrometer for studying the dynamics of soft materials, while also delivering competitive performance for investigating phonon dynamics in hard condensed matter systems, including a broad range of quantum materials.

43 PARTICLE ACCELERATORS↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct Reactions and Spectroscopy with Hydrogen Targets at the RIBF

The implementation of MINOS, a liquid-hydrogen target and vertex-tracking system, at the Radioactive Isotope Beam Factory (RIBF) of the RIKEN Nishina Center has led to numerous nuclear physics discoveries. In experiments involving rare-isotope beams at intermediate energies, MINOS was integrated with the DALI2 + γ-ray spectrometer and other auxiliary devices. These were positioned in front of both the ZeroDegree Spectrometer and the SAMURAI magnetic spectrometers for the identification of ejectiles following quasi-free scattering direct reactions. Notable outcomes include the first spectroscopy of unstable doubly magic nucleus, investigations into multi-neutron decays, and the study of shell evolution along isotopic chains. These studies have significantly advanced our understanding of nuclear structure, as well as the mechanism of direct reactions with fast beams. Simultaneously, these direct reactions enabled raising new physics questions and paved the way for next-generation experimental setups to address them. Through the combination of particle- and γ-spectroscopy with a broad range of nuclear reactions, new frontiers will be established in our understanding of nuclear structure and reaction mechanisms. Here, we review the past ten years of studies on direct reactions and spectroscopy of exotic nuclei with liquid-hydrogen targets at the RIBF and define a vision for the future.

Bertulani, Carlos A [East Texas A & M Univ., Comme↗

pathSQE : an automated workflow for single-crystal inelastic neutron scattering data processing and analysis

Inelastic neutron scattering (INS) experiments utilizing modern time-of-flight spectrometers enable the comprehensive mapping of the energy (E)- and momentum (Q)-resolved dynamical structure factor of single crystals, probing both the lattice and magnetic excitations. Yet, the large size and complexity of four-dimensional INS data are challenging current analysis workflows, often resulting in an underutilization of the measured information. To help address this issue, this paper introduces new software interfaced with the Mantid framework, pathSQE, designed to streamline the processing, analysis and interpretation of 4D single-crystal INS data. By automating key tasks such as 1D/2D slicing, symmetrization, Brillouin zone folding, data visualization, prioritization and filtering, and comparisons with simulations, pathSQE facilitates and accelerates INS data analysis workflows. Here, this paper outlines the features and implementation and provides several illustrations of the use of pathSQE on data collected on single crystals using direct-geometry time-of-flight spectrometers at the Spallation Neutron Source, including Ge, FeSi, MnO and SnS single-crystal measurements on the ARCS, HYSPEC and CNCS neutron spectrometers. Beyond streamlining post-experiment data processing, pathSQE establishes an automated and modular processing pipeline that could support future real-time experiment steering.

36 MATERIALS SCIENCE↗

Using photoelectron spectroscopy to measure resonant inelastic X-ray scattering: a computational investigation

Resonant inelastic X-ray scattering (RIXS) has become an important scientific tool. Nonetheless, conventional high-resolution (few hundred meV or less) RIXS measurements, especially in the soft X-ray range, require low-throughput grating spectrometers, which limits measurement accuracy. Here, the performance of a different method for measuring RIXS, i.e. photoelectron spectrometry for analysis of X-rays (PAX), is computationally investigated. This method transforms the X-ray measurement problem of RIXS to an electron measurement problem, enabling use of high-throughput, compact electron spectrometers. X-rays to be measured are incident on a converter material and the energy distribution of the resultant photoelectrons, the PAX spectrum, is measured with an electron spectrometer. A deconvolution algorithm for analysis of such PAX data is proposed. It is shown that the deconvolution algorithm works well on data recorded with ~0.5 eV resolution. Additional simulations show the potential of PAX for estimation of RIXS features with smaller widths. For simulations using the 3d levels of Ag as a converter material, and with 10 5 simulated detected electrons, it is estimated that features with a few hundred meV width can be accurately estimated in a model RIXS spectrum. For simulations using a sharp Fermi edge to encode RIXS spectra, it is estimated that one can accurately distinguish 100 meV FWHM peaks separated by 45 meV with 10 5 simulated detected electrons that were photoemitted from within 0.4 eV of the Fermi level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗