Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Glycerol Adsorption on TiO 2 Surfaces: A Systematic Periodic DFT Study

Abstract Conversion of glycerol to added‐value products is desirable due to its surplus during biodiesel synthesis. TiO 2 has been the most explored catalyst. We performed a systematic study of glycerol adsorption on anatase (101), anatase (001), and rutile (110) TiO 2 at the Density Functional Theory level. We found several adsorption modes on these surfaces, with anatase (101) being the less reactive one, leading to adsorption energies between −0.8 and −0.4 eV, with all adsorptions molecular in nature. On the contrary, anatase (001) is the most reactive surface, leading to both molecular and dissociative adsorption modes, with energies ranging from −4 to −1 eV and undergoing severe surface reconstructions in some cases. Rutile (110) also shows both molecular and dissociative adsorptions, but it is less reactive than anatase (001). Surfaces with oxygen vacancies affects the adsorbed states and energies. The electronic structure analysis reveals that glycerol adsorption mainly affects the band gap of the material and not the individual contributions to the valence and conduction band. Bader charge analysis shows that strong adsorption modes on anatase (001) and rutile (110) are associated with large charge transfer from glycerol to the surface, while weak and molecular adsorption modes involve low charge transfer.

Chemistry↗

A systematic evaluation of wind's capacity credit in the Western United States

Abstract The degree to which wind energy can contribute to the capacity needed to meet resource adequacy requirements, also known as capacity credit (CC), can be impacted by many factors. The CC varies regionally with wind resource and correlation to net load and may also vary with wind technology (land‐based versus offshore) and turbine specifications. We use a probabilistic resource adequacy tool to systematically assess the CC of multiple technologies for near‐term wind deployment across the Western US power system to help inform planning decisions. We find that wind CC varies by weather year and location but averages 16% for land‐based turbines and 41% for offshore turbines, with large regional variations. The average wind CC increases to 20% for land‐based and 53% for offshore when considering only the sites in the top 25th percentile of capacity factor. The CC of land‐based wind is generally lower than its capacity factor, which indicates a low correlation of generation to system needs. However, offshore wind shows a substantially higher CC, which is driven by not only a higher capacity factor but also a greater correlation with system needs.

17 WIND ENERGY↗

Systematizing the effective theory of self-interacting dark matter

If dark matter has strong self-interactions, future astrophysical and cosmological observations, together with a clearer understanding of baryonic feedback effects, might be used to extract the velocity dependence of the dark matter scattering rate. To interpret such data, we should understand what predictions for this quantity are made by various models of the underlying particle nature of dark matter. In this paper, we systematically compute this function for fermionic dark matter with light bosonic mediators of vector, scalar, axial vector, and pseudoscalar type. We do this by matching to the nonrelativistic effective theory of self-interacting dark matter and then computing the spin-averaged viscosity cross section nonperturbatively by solving the Schrödinger equation, thus accounting for any possible Sommerfeld enhancement of the low-velocity cross section. In the pseudoscalar case, this requires a coupled-channel analysis of different angular momentum modes. We find, contrary to some earlier analyses, that nonrelativistic effects only provide a significant enhancement for the cases of light scalar and vector mediators. Scattering from light pseudoscalar and axial vector mediators is well described by tree-level quantum field theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diagnostic performance of F-18 FDG PET/CT for prediction of KRAS mutation in colorectal cancer patients: a systematic review and meta-analysis

Objective: The purpose of the current study was to investigate the diagnostic performance of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the prediction of v-Ki-ras-2 Kirsten rat sarcoma viral oncogene homolog (KRAS) mutation in colorectal cancer (CRC) patients through a systematic review and meta-analysis. Methods: The PubMed and EMBASE database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for prediction of KRAS mutation in CRC patients. Results: Across 9 studies (804 patients), the pooled sensitivity for F-18 FDG PET/CT was 0.66 (95% CI 0.60–0.73) without heterogeneity (I{sup 2} = 34.1, p = 0.14) and a pooled specificity of 0.67 (95% CI 0.62–0.72) without heterogeneity (I{sup 2} = 1.63, p = 0.42). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 2.0 (95% CI 1.7–2.4) and negative likelihood ratio (LR−) of 0.5 (95% CI 0.41–0.61). The pooled diagnostic odds ratio (DOR) was 4 (95% CI 3–6). Hierarchical summary receiver operating characteristic (ROC) curve indicates that the areas under the curve were 0.69 (95% CI 0.65–0.73). Conclusion: The current meta-analysis showed the low sensitivity and specificity of F-18 FDG PET/CT for prediction of KRAS mutation in CRC patients. The DOR was very low and the likelihood ratio scatter-gram indicated that F-18 FDG PET/CT might not be useful for prediction of KRAS mutation and not for its exclusion. Therefore, cautious application and interpretation should be paid to the F-18 FDG PET/CT for prediction of KRAS mutation in CRC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic accuracy of F-18 FDG PET/CT for characterization of colorectal focal FDG uptake: a systematic review and meta-analysis

Introduction: We aimed to explore the role of the diagnostic accuracy of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) for characterization of incidental colorectal focal FDG uptake through a systematic review and meta-analysis. Methods: The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR−), and constructed summary receiver operating characteristic curves. Results: Across 8 studies (1451 patients), the pooled sensitivity for F-18 FDG PET/CT was 0.87 (95% CI 0.82–0.90) without heterogeneity (χ{sup 2} = 10.84, p = 0.37) and a pooled specificity of 0.83 (95% CI 0.76–0.89) with heterogeneity (χ{sup 2} = 130.1, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 5.2 (95% CI 3.6–7.4) and negative likelihood ratio (LR−) of 0.16 (95% CI 0.12–0.22). The pooled DOR was 32 (95% CI 20–51). Conclusion: F-18 FDG PET/CT demonstrated good sensitivity and specificity for characterization of incidental colorectal focal FDG uptake. At present, the literature regarding the use of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subintimal Angioplasty for Peripheral Arterial Occlusive Disease: A Systematic Review

The objective of this study was to summarize outcomes of subintimal angioplasty (SA) for peripheral arterial occlusive disease. The Cochrane Library, Medline and Embase databases were searched to perform a systematic review of the literature from 1966 through May 2007 on outcomes of SA for peripheral arterial occlusive disease of the infrainguinal vessels. The keywords 'percutaneous intentional extraluminal revascularization,' 'subintimal angioplasty,' 'peripheral arterial disease,' 'femoral artery,' 'popliteal artery,' and 'tibial artery' were used. Assessment of study quality was done using a form based on a checklist of the Dutch Cochrane Centre. The recorded outcomes were technical and clinical success, primary (assisted) patency, limb salvage, complications, and survival, in relation to the clinical grade of disease (intermittent claudication or critical limb ischemia [CLI] or mixed) and location of lesion (femoropopliteal, crural, or mixed). Twenty-three cohort studies including a total of 1549 patients (range, 27 to 148) were included in this review. Methodological and reporting quality were moderate, e.g., there was selection bias and reporting was not done according to the reporting standards. These and significant clinical heterogeneity obstructed a meta-analysis. Reports about length of the lesion and TASC classification were too various to summarize or were not mentioned at all. The technical success rates varied between 80% and 90%, with lower rates for crural lesions compared with femoral lesions. Complication rates ranged between 8% and 17% and most complications were minor. After 1 year, clinical success was between 50% and 70%, primary patency was around 50% and limb salvage varied from 80% to 90%. In conclusion, taking into account the methodological shortcomings of the included studies, SA can play an important role in the treatment of peripheral arterial disease, especially in the case of critical limb ischemia. Despite the moderate patency rates after one year, SA may serve as a 'temporary bypass' to provide wound healing and limb salvage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization Before Liver Resection: A Systematic Review

This is a review of literature on the indications, technique, and outcome of portal vein embolization (PVE). A systematic literature search on outcome of PVE from 1990 to 2011 was performed in Medline, Cochrane, and Embase databases. Forty-four articles were selected, including 1,791 patients with a mean age of 61 {+-} 4.1 years. Overall technical success rate was 99.3 %. The mean hypertrophy rate of the FRL after PVE was 37.9 {+-} 0.1 %. In 70 patients (3.9 %), surgery was not performed because of failure of PVE (clinical success rate 96.1 %). In 51 patients (2.8 %), the hypertrophy response was insufficient to perform liver resection. In the other 17 cases, 12 did not technically succeed (0.7 %) and 7 caused a complication leading to unresectability (0.4 %). In 6.1 %, resection was cancelled because of local tumor progression after PVE. Major complications were seen in 2.5 %, and the mortality rate was 0.1 %. A head-to-head comparison shows a negative effect of liver cirrhosis on hypertrophy response. The use of n-butyl cyanoacrylate seems to have a greater effect on hypertrophy, but the difference with other embolization materials did not reach statistical significance. No difference in regeneration is seen in patients with cholestasis or chemotherapy. Preoperative PVE has a high technical and clinical success rate. Liver cirrhosis has a negative effect on regeneration, but cholestasis and chemotherapy do not seem to have an influence on the hypertrophy response. The use of n-butyl cyanoacrylate may result in a greater hypertrophy response compared with other embolization materials used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Active Splenic Bleeding After Colonoscopy: A Systematic Review of the Literature

Purpose: Colonoscopy is reported to be a safe procedure that is routinely performed for the diagnosis and treatment of colorectal diseases. Splenic rupture is considered to be a rare complication with high mortality and morbidity that requires immediate diagnosis and management. Nonoperative management (NOM), surgical treatment (ST), and, more recently, proximal splenic artery embolization (PSAE) have been proposed as treatment options. The goal of this study was to assess whether PSAE is safe even in high-grade ruptures. Methods: We report two rare cases of post colonoscopy splenic rupture. A systematic review of the literature from 2002 to 2010 (first reported case of PSAE) was performed and the three types of treatment compared. Results: All patients reviewed (77 of 77) presented with intraperitoneal hemorrhage due to isolated splenic trauma. Splenic rupture was high-grade in most patients when grading was possible. Six of 77 patients (7.8 %) were treated with PSAE, including the 2 cases reported herein. Fifty-seven patients (74 %) underwent ST. NOM was attempted first in 25 patients with a high failure rate (11 of 25 [44 %]) and requiring a salvage procedure, such as PSAE or ST. Previous surgery (31 of 59 patients), adhesions (10 of 13), diagnostic colonoscopies (49 of 71), previous biopsies or polypectomies (31 of 57) and female sex (56 of 77) were identified as risk factors. In contrast, splenomegaly (0 of 77 patients), medications that increase the risk of bleeding (13 of 30) and difficult colonoscopies (16 of 51) were not identified as risk factors. PSAE was safe and effective even in elderly patients with comorbidities and those taking medications that increase the risk of bleeding, and the length of the hospital stay was similar to that after ST. Conclusion: We propose a treatment algorithm based on clinical and radiological criteria. Because of the high failure rate after NOM, PSAE should be the treatment of choice to manage grade I through IV splenic ruptures after colonoscopy in hemodynamically stabilized patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis

Purpose. To establish the efficacy and safety of the preclose technique in total percutaneous endovascular aortic repair (PEVAR).MethodsA systematic literature search of Medline database was conducted for series on PEVAR published between January 1999 and January 2012.ResultsThirty-six articles comprising 2,257 patients and 3,606 arterial accesses were included. Anatomical criteria used to exclude patients from undergoing PEVAR were not uniform across all series. The technical success rate was 94 % per arterial access. Failure was unilateral in the majority (93 %) of the 133 failed PEVAR cases. The groin complication rate in PEVAR was 3.6 %; a minority (1.6 %) of these groin complications required open surgery. The groin complication rate in failed PEVAR cases converted to groin cutdown was 6.1 %. A significantly higher technical success rate was achieved when arterial access was performed via ultrasound guidance. Technical failure rate was significantly higher with larger sheath size ({>=}20F). Conclusion. The preclose technique in PEVAR has a high technical success rate and a low groin complication rate. Technical success tends to increase with ultrasound-guided arterial access and decrease with larger access. When failure occurs, it is unilateral in the majority of cases, and conversion to surgical cutdown does not appear to increase the operative risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How MRI Compatible is 'MRI Compatible'? A Systematic Comparison of Artifacts Caused by Biopsy Needles at 3.0 and 1.5 T

Purpose: This study was designed to systematically investigate artifacts caused by interventional needles recommended for use in MRI, with focus on field strength, needle/mandrin type, orientation and sequence. Methods: Eight different MRI compatible needles were placed in porcine tissue and examined at 1.5 and 3.0 T with balanced-steady-state-free-precession (B-SSFP) and T1-weighted-spoiled-gradient-echo (T1-SPGR) sequences in different orientations to B{sub 0}. Artifact diameters with regards to the primary, inner, and secondary, outer artifacts were assessed and statistically evaluated. Results: The types and degree of artifacts varied considerably, especially between different mandrin types even for the same needles. Orientation of the needle in the magnetic field was another main contributor to the artifact dimensions. Less important factors were the type of pulse sequence and field strength. Artifacts ranged from 0.7 mm (steel, 0 Degree-Sign , B-SSFP, 3.0 T, inner) to 71.4 mm (nitinol, 90 Degree-Sign , B-SSFP, 1.5 T, outer). Inner artifact diameters in B-SSFP were slightly larger (8.2 {+-} 5.7 mm) than those in T1-SPGR (7.6 {+-} 5.4 mm) and comparable between 1.5 and 3.0 T (e.g., 8.0 vs. 8.4 mm, B-SSFP). Conclusions: Although all were sold as 'MR compatible,' the artifacts differed greatly between needle types, and even more so for different mandrins. The results suggest an empirical approach to the needle choice based on lesion type and approach angle.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Management of Cephalic Arch Stenosis in Arteriovenous Fistulas for Hemodialysis: A Systematic Review

AimTo conduct a systematic review of management of current cephalic arch stenosis (CAS) and associated outcomes in the context of dysfunctional hemodialysis access.Materials and MethodsPubMed, Web of Science, and Cochrane Library were searched to retrieve literature on the management of CAS. Studies had to focus on management of access stenosis solely in the cephalic arch. Case reports and literature reviews were excluded. Studies were categorized by intervention, and primary and secondary patency data were compiled. Studies were aggregated, and meta-analyses were performed where possible.ResultsNine papers satisfied the aforementioned criteria: five were retrospective studies and four were prospective studies. CAS management strategies have included percutaneous transluminal balloon angioplasty (PTA), peripheral cutting balloons, surgical cephalic vein transpositions, bare stents, and stent grafts. Reporting strategies varied between studies. Meta-analyses showed that results were variable even within studies using the same modality, particularly for PTA.ConclusionNo singular, definitive management strategy exists for CAS. Current studies are limited by being primarily single-center retrospective trials featuring heterogenous patient populations, interventions, and endpoints. Priorities for future studies should include larger randomized trials, more uniform management strategies and endpoints, and a longer duration of follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency and Microwave Ablation Compared to Systemic Chemotherapy and to Partial Hepatectomy in the Treatment of Colorectal Liver Metastases: A Systematic Review and Meta-Analysis

PurposeTo assess safety and outcome of radiofrequency ablation (RFA) and microwave ablation (MWA) as compared to systemic chemotherapy and partial hepatectomy (PH) in the treatment of colorectal liver metastases (CRLM).MethodsMEDLINE, Embase and the Cochrane Library were searched. Randomized trials and comparative observational studies with multivariate analysis and/or matching were included. Guidelines from National Guideline Clearinghouse and Guidelines International Network were assessed using the AGREE II instrument.ResultsThe search revealed 3530 records; 328 were selected for full-text review; 48 were included: 8 systematic reviews, 2 randomized studies, 26 comparative observational studies, 2 guideline-articles and 10 case series; in addition 13 guidelines were evaluated. Literature to assess the effectiveness of ablation was limited. RFA + systemic chemotherapy was superior to chemotherapy alone. PH was superior to RFA alone but not to RFA + PH or to MWA. Compared to PH, RFA showed fewer complications, MWA did not. Outcomes were subject to residual confounding since ablation was only employed for unresectable disease.ConclusionThe results from the EORTC-CLOCC trial, the comparable survival for ablation + PH versus PH alone, the potential to induce long-term disease control and the low complication rate argue in favour of ablation over chemotherapy alone. Further randomized comparisons of ablation to current-day chemotherapy alone should therefore be considered unethical. Hence, the highest achievable level of evidence for unresectable CRLM seems reached. The apparent selection bias from previous studies and the superior safety profile mandate the setup of randomized controlled trials comparing ablation to surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization of Spontaneous Soft Tissue Hematomas: A Systematic Review

Background: Severe spontaneous soft tissue hematomas (SSTH) are usually treated with transcatheter arterial embolization (TAE) although only limited retrospective studies exist evaluating this treatment option. The aim of this study was to systematically assess the efficacy and safety of TAE for the management of SSTH. Methods: Medline, EMBASE, PubMed and Cochrane Library were searched from inception to July 2017 using MeSH headings and a combination of keywords. Eligibility was restricted to original studies with patients suffering from SSTH treated with TAE. Patients with traumatic hematomas or who were treated with solely conservative or surgical management were excluded. For each publication, clinical success based on the control of the bleed, rebleeding rates and complications (including mortality) was collected, as well as technical details. Results: Sixty-three studies met the inclusion criteria, with an aggregate total of 267 patients. Follow-up extended from 1 day to 10 years. Bleeding was mainly localized to the iliopsoas (n = 113/267, 42.3%) and anterior abdominal wall (n = 145/266, 54.7%). When information was available, 81.0% (n = 158/195) of patients were on anticoagulant therapy prior to the bleeding episode. Initial stabilization with control of the bleed was obtained in 93.1% (n = 242 patients, n = 60 studies). The most common embolic materials were coils (n = 129, 54.4%). Rebleeding was reported in 25 patients (9.4%). Only two embolization complications were reported (0.7%). The 30-day mortality was 22.7% (n = 42/1857). Conclusion: TAE represents a safe and effective procedure in the management of SSTH. We present a management algorithm based on these data, but further studies are needed to address the knowledge gap.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reynolds stress tensor measurements using magnetic resonance velocimetry: expansion of the dynamic measurement range and analysis of systematic measurement errors

This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.

42 ENGINEERING↗

Systematic Layout Planning of a Radiology Reporting Area to Optimize Radiologists’ Performance

Optimizing radiologists’ performance is a major priority for managers of health services/systems, since the radiologists’ reporting activity imposes a severe constraint on radiology productivity. Despite that, methods to optimize radiologists’ reporting workplace layout are scarce in the literature. This study was performed in the Radiology Division (RD) of an 850-bed University-based general hospital. The analysis of the reporting workplace layout was carried out using the systematic layout planning (SLP) method, in association with cluster analysis as a complementary tool in early stages of SLP. Radiologists, architects, and hospital managers were the stakeholders consulted for the completion of different stages of the layout planning process. A step-by-step description of the proposed methodology to plan an RD reporting layout is presented. Clusters of radiologists were defined using types of exams reported and their frequency of occurrence as clustering variables. Sectors with high degree of interaction were placed in proximity in the new RD layout, with separation of noisy and quiet areas. Four reporting cells were positioned in the quiet area, grouping radiologists by subspecialty, as follows: cluster 1-abdomen; cluster 2-musculoskeletal; cluster 3-neurological, vascular and head & neck; cluster 4-thoracic and cardiac. The creation of reporting cells has the potential to limit unplanned interruptions and enhance the exchange of knowledge and information within cells, joining radiologists with the same expertise. That should lead to improvements in productivity, allowing managers to more easily monitor radiologists’ performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The environmental impact of hydropower: a systematic review of the ecological effects of sub-daily flow variability on riverine fish

Hydropower can help facilitate power grid decarbonization because it can respond to short-term changes in power demand and is comparatively more reliable than intermittent wind and solar. However, flexible hydropower operations can create rapid and abnormal fluctuations in downstream flow conditions, which can negatively impact aquatic ecosystems. Accordingly, we conducted a systematic review on the ecological effects of hydropower-driven sub-daily flow variability (SDFV) on riverine fishes. We reviewed and synthesized 109 articles relevant to fish-SDFV relationships from seven sources, most of which focused on Salmonids in North America and northern and western Europe and were published in the last 15 years. We found strong agreement in the literature that SDFV increases fish stranding risk, destabilizes habitat, and decreases production and diversity. We found moderate agreement that SDFV interrupts fish reproduction, increases or has no impact on condition, and prompts or discourages movement depending on local channel conditions. We found little to no agreement for relationships between SDFV and mortality, physiology, and behavior. The effects of SDFV on riverine fish ecology are intertwined in the complex suite of biotic and abiotic characteristics that structure aquatic ecosystems and are highly site-, species-, and life stage-specific. Assessments of the impact of SDFV on fish ecology should first characterize local habitat and channel quality and fish community composition to identify specific, measurable ecological outcomes to sustain or enhance, and then design mitigation strategies tailored to those ecological objectives.

13 HYDRO ENERGY↗

Systematic Insight into Chloride Concentration, Applied Potential and Time Effect on the Passive Film of Cu-Zn-Ni Ternary Alloy in Alkaline Solution

The effects of chloride concentration, applied potential and time on the passive film of Cu-Zn-Ni ternary alloy in alkaline solution were systematically investigated using potentiodynamic and potentiostatic polarizations, electrochemical impedance spectroscopy, Mott–Schottky analysis, laser confocal microscopy, atomic force microscopy and x-ray photoelectron spectroscopy. Results showed that the pitting potential decreased as a linear function of log(a{sub Cl{sup −}}), and the size of pits extended faster in the horizontal direction than in the vertical direction. The passive oxide film formed on Cu-Zn-Ni alloy mainly exhibited p-type semiconductor behavior, which was consistent with cuprous and nickel oxide, the main components in the film. The density of cation vacancy (approximately 10{sup 20}-10{sup 21} cm{sup −3}) increased with potentiostatic time but reduced by the increasing potentials. The kinetics of passive film growth followed a parabolic law D = m * t{sup n}, where m is a constant considered as the initial growth rate and n is the time exponent. Subsequent to the formation of a compact and coherent passive film at higher potential, it was hard for an ion to migrate or for an aggressive ion to penetrate, which indicated better corrosion resistance for passive film formed under higher potential.

36 MATERIALS SCIENCE↗

Systematic Ion Source Parameter Assessment by Automated Determination of the Distribution of Ion Acceptance (DIA) Using APLI

The determination of the spatially resolved ion signal with atmospheric pressure laser ionization (APLI), which was introduced as distribution of ion acceptance (DIA), serves as a valuable tool for the understanding of complex and highly dynamical conditions in modern atmospheric pressure (AP) ion sources. DIA provides information about fluid dynamics, ion transport, and ion transformation processes in such sources and is an ideal basis for the validation of numerical models of the dynamics in the ion source enclosure. We present a fully automated setup for DIA measurements, which enabled us to acquire a comprehensive dataset of over 700 individual DIA measurements in a commercial AP ion source (Bruker Multi Purpose Ion Source, MPIS). Ion source parameters as voltages, gas heater temperatures and gas flows, were varied, and the effect of those parameters on the DIA of a chemically inert analyte, pyrene, was systematically investigated. It is shown that the response of the DIA is nonlinear and that gas dynamics largely dominates the ion transport in the ion source. Particularly, the position of the heated nebulizer, which is used to introduce one of two gas flows and the analyte into the ion source chamber, had a profound effect on the DIA. This suggests that the gas dynamics in the source switches between different states. The now available comprehensive DIA dataset reveals such critical effects and will guide further numerical modeling efforts to understand the details of the dynamics of ions in the source chamber. .

74 ATOMIC AND MOLECULAR PHYSICS↗