Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST PROTOCOL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

How to achieve patient-centered testing: role of the protocol nurse

Introduction: Patient-centered cardiac testing is predicated on choosing the right test for the right patient. We studied the effects of changing from script-driven scheduling to nurse-driven protocoling of stress tests. Methods and Results: A protocol nurse reviewed records before scheduling and communicated with patients and ordering providers if needed. We found that instituting nurse protocolling of all non-imaging (ETT) and nuclear (MPI) stress tests (N = 3071) resulted in protocol changes in 37% of our patients, and reduced the proportion of tests that could not be performed as scheduled by 56% and cancelations by 71% (P < 0.001 for each). These changes were sustained over two successive 6-month periods following a baseline observation period of 6 months. For MPI, the most frequent nurse interventions were re-protocoling as stress-first MPI (12% of tests), changing test location for clinical reasons (13%), changing stress modality (7%), and care coordination (5%). Conclusions: Changing from script-driven scheduling to protocol nursing contributed measurably to patient-centered testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced orbiting systems test-bedding and protocol verification

The Consultative Committee for Space Data Systems (CCSDS) has begun the development of a set of protocol recommendations for Advanced Orbiting Systems (SOS). The AOS validation program and formal definition of AOS protocols are reviewed, and the configuration control of the AOS formal specifications is summarized. Independent implementations of the AOS protocols by NASA and ESA are discussed, and cross-support/interoperability tests which will allow the space agencies of various countries to share AOS communication facilities are addressed.

Noles, James↗

Human Factors Ground Test Assessment and Protocol Development for Space Radiation Protection Concepts

Human factors evaluations and procedures were developed in a series of ground tests in order to assess novel radiation protection concepts developed by industry leaders in aerospace. In addition, NASA’s current prototype space radiation protection vest and storm shelter concept were tested using the newly drafted human factors assessment materials. Evaluation procedures and wearable garment technology were tested at Johnson Space Center (JSC) using a small sample of current NASA crewmembers for garment testing. Results for the garment analysis indicated that the current radiation vest ultimately did not hinder task performance or impede mobility. Results from the storm shelter analysis indicated that crew were able to construct the shelter within the time allotment without difficulty and limited reference to instruction materials. These data will be used to further develop wearable garment technology and storm shelter designs. Newly developed procedures will be used in future ground tests to further assess novel radiation protection concepts.

Hanson, Julie A.↗

Development, Validation and Approval of A Planetary Extravehicular Activity Prebreathe Protocol: NASA Exploration Atmosphere Tests 1 & 2

INTRODUCTION: Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions as planned by the Artemis program. Living in an “Exploration Atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. A prebreathe validation campaign at NASA’s Johnson Space Center in 2022–2023 has aimed to validate the prebreathe durations and is being operationalized by NASA for use in upcoming Lunar EVAs. METHODS: Twelve volunteers lived in a hyboparic chamber for 11 days with an “exploration atmosphere” of 56.6kPa/34% O2 66% N2. Subjects acclimated to this atmosphere for 48 hrs and thereafter participated in five 6-hour simulated EVAs at 34kPa/85% O2 / 15% N2 over the course of 11 days. Prior to each simulated EVA, subjects underwent a 20-minute prebreathe at 85% O2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was evaluated during the simulated EVA by serial doppler and echocardiographs alternating every 15 min, as well as clinical monitoring for DCS signs/symptoms. Venous gas emboli (VGE) and DCS outcomes were verified against NASA Standard 3001, which guides allowable prebreathe protocol acceptance criteria. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were identified during EVAs. No Grade IV VGE were observed. Two cases of mild, Type I DCS were identified in the subjects over the course of 50 EVA exposures. Ten planned EVA exposures were eliminated due to mask fit, metabolic rate, or subject safety concerns. One subject was removed from the study due to presence of left ventricular VGE. Additionally, two doppler techs also experienced DCS, and one case of hypoxia was noted. All cases of DCS resolved with treatment. No cases of severe DCS were observed. The observed incidence (4%, 1.1–13.5% at 95% confidence) met the NASA Standard 3001 criteria leading to the transition of this protocol from research to operational use for upcoming Lunar missions.

Exploration Atmosphere↗

Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits

A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have beendeveloped for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits

A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have been developed for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advances in benchmarking and round robin testing for PEM water electrolysis: Reference protocol and hardware

While the number of publications in the PEM water electrolysis community increases each year, no common ground concerning reference hardware (test cells and test bench) and testing protocols has been yet established. This would, however, be necessary for the comparability of experimental results. First attempts for such reference hardware and procedures have been made in the framework of the Task 30 Electrolysis within the Technology Collaboration Programme on Advanced Fuel Cells (AFC TCP) of the International Energy Agency (IEA). Since then, improvements of both the test hardware (test cell and components) as well as the measurement protocol were identified, and a revised methodology and key results based on a comprehensive measurement series have been obtained. A detailed protocol for testing commercial reference components with a reference laboratory test cell developed in-house by Fraunhofer ISE is presented. For evaluation of the protocol and the hardware, it was tested at three different institutions at the same time. Impedance spectroscopic and polarization data was acquired and analyzed. The obtained differences in performance were calculated to give the community an expectation window to compare own data to. Finally, the importance of a thorough temperature control and the conditioning phase are demonstrated.

08 HYDROGEN↗

Internet Protocol Over Telemetry Testing for Earth Science Capability Demo Summary

The development and flight tests described here focused on utilizing existing pulse code modulation (PCM) telemetry equipment to enable on-vehicle networks of instruments and computers to be a simple extension of the ground station network. This capability is envisioned as a necessary component of a global range that supports test and development of manned and unmanned airborne vehicles.

Franz, Russ↗

Microgravity Flame Spread in Exploration Atmospheres: Pressure, Oxygen, and Velocity Effects on Opposed and Concurrent Flame Spread

Microgravity tests of flammability and flame spread were performed in a low-speed flow tunnel to simulate spacecraft ventilation flows. Three thin fuels were tested for flammability (Ultem 1000 (General Electric Company), 10 mil film, Nomex (Dupont) HT90-40, and Mylar G (Dupont) and one fuel for flame spread testing (Kimwipes (Kimberly-Clark Worldwide, Inc.). The 1g Upward Limiting Oxygen Index (ULOI) and 1g Maximum Oxygen Concentration (MOC) are found to be greater than those in 0g, by up to 4% oxygen mole fraction, meaning that the fuels burned in 0g at lower oxygen concentrations than they did using the NASA Standard 6001 Test 1 protocol. Flame spread tests with Kimwipes were used to develop correlations that capture the effects of flow velocity, oxygen concentration, and pressure on flame spread rate. These correlations were used to determine that over virtually the entire range of spacecraft atmospheres and flow conditions, the opposed spread is faster, especially for normoxic atmospheres. The correlations were also compared with 1g MOC for various materials as a function of pressure and oxygen. The lines of constant opposed flow agreed best with the 1g MOC trends, which indicates that Test 1 limits are essentially dictated by the critical heat flux for ignition. Further evaluation of these and other materials is continuing to better understand the 0g flammability of materials and its effect on the oxygen margin of safety.

Olson, Sandra L.↗

SCPS-TP, TCP, and Rate-Based Protocol Evaluation

Tests were performed at Glenn Research Center to compare the performance of the Space Communications Protocol Standard Transport Protocol (SCPS TP, otherwise known as "TCP Tranquility") relative to other variants of TCP and to determine the implementation maturity level of these protocols, particularly for higher speeds. The testing was performed over reasonably high data rates of up to 100 Mbps with delays that are characteristic of near-planetary environments. The tests were run for a fixed packet size, but for variously errored environments. This report documents the testing performed to date.

Tran, Diepchi T.↗

Design of a Channel Error Simulator using Virtual Instrument Techniques for the Initial Testing of TCP/IP and SCPS Protocols

There exists a need for designers and developers to have a method to conveniently test a variety of communications parameters for an overall system design. This is no different when testing network protocols as when testing modulation formats. In this report, we discuss a means of providing a networking test device specifically designed to be used for space communications. This test device is a PC-based Virtual Instrument (VI) programmed using the LabVIEW(TM) version 5 software suite developed by National Instruments(TM)TM. This instrument was designed to be portable and usable by others without special, additional equipment. The programming was designed to replicate a VME-based hardware module developed earlier at New Mexico State University (NMSU) and to provide expanded capabilities exceeding the baseline configuration existing in that module. This report describes the design goals for the VI module in the next section and follows that with a description of the design of the VI instrument. This is followed with a description of the validation tests run on the VI. An application of the error-generating VI to networking protocols is then given.

Horan, Stephen↗

CAPTIONALS: A computer aided testing environment for the verification and validation of communication protocols

This paper covers the verification and protocol validation for distributed computer and communication systems using a computer aided testing approach. Validation and verification make up the so-called process of conformance testing. Protocol applications which pass conformance testing are then checked to see whether they can operate together. This is referred to as interoperability testing. A new comprehensive approach to protocol testing is presented which address: (1) modeling for inter-layer representation for compatibility between conformance and interoperability testing; (2) computational improvement to current testing methods by using the proposed model inclusive of formulation of new qualitative and quantitative measures and time-dependent behavior; (3) analysis and evaluation of protocol behavior for interactive testing without extensive simulation.

Feng, C.↗

Verification and performance tests of HYCAR program

The HYCAR program simulates the network protocols of HYPERchannel and Fiber Optic Demonstration System (FODS) and other related protocols. Verification tests of the program were conducted using the FODS protocol. The tests validated the operation of the program through deterministic and analytical means. Extensive experimentation with the simulator produced a set of performance characteristics for the FODS protocol under varied loading conditions. These characteristics are consistent with those expected, and are documented with the validation tests.

Bhatia, Veena↗

Phase III integrated water recovery testing at MSFC - Design, plans, and protocols

A series of tests is being conducted at the NASA Marshall Space Flight Center (MSFC) to evaluate the performance of a closed-loop water recovery system. Testing will be conducted at various levels of integration and loop-closure, culminating in complete closure of the water system with man-in-the-loop. This paper summarizes the test goals and objectives as well as the system design, plans, and protocols which have been established.

Bagdigian, Robert M.↗

Development and Field-Testing of a Study Protocol, including a Web-Based Occupant Survey Tool, for Use in Intervention Studies of Indoor Environmental Quality

We developed and pilot-tested an overall protocol for intervention studies to evaluate the effects of indoor environmental changes in office buildings on the health symptoms and comfort of occupants. The protocol includes a web-based survey to assess the occupant's responses, as well as specific features of study design and analysis. The pilot study, carried out on two similar floors in a single building, compared two types of ventilation system filter media. With support from the building's Facilities staff, the implementation of the filter change intervention went well. While the web-based survey tool worked well also, low overall response rates (21-34percent among the three work groups included) limited our ability to evaluate the filter intervention., The total number of questionnaires returned was low even though we extended the study from eight to ten weeks. Because another simultaneous study we conducted elsewhere using the same survey had a high response rate (>70percent), we conclude that the low response here resulted from issues specific to this pilot, including unexpected restrictions by some employing agencies on communication with occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗