Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRACE CONTAMINANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Lunar Impact Melt Crystallization Produces Reflectance Spectra Dominated By Clinopyroxene Signatures: Implications for the Origin of Pink Spinel Anorthosite

Magma-wallrock interaction and impact melt crystallization are the two leading hypotheses for the formation of orbitally detected lunar “pink” spinel anorthosite (PSA) [1-3]. Distinguishing among hypotheses is complicated because both require mixing of anorthositic crust and MgO-rich ultramafic components. Models for PSA formation need to account for either the thermodynamic hurdles of crustal assimilation, or the size of impactor and composition of target material needed to generate spinel during crater and basin formation. Determining whether the energy source is endogenic or exogenic is important for understanding the thermal and chemical evolution of the lunar crust. Here we test the impact melt hypothesis by performing controlled cooling experiments on two hypothetical impact melt compositions. The compositions represent mixing of ultramafic magma and anorthositic crust in molar ratios of approximately 50:50 and 25:75. Synthetic crystallized assemblages were prepared for chemical analysis and bidirectional reflectance spectroscopy in the visible to near-infrared wavelengths. All crystallization experiments contained plagioclase, olivine, and clinopyroxene, but trace amounts of spinel were only observed in the 50:50 mix. The experimental spinel is similar to the compositions inferred from remote observations. However, the high-Ca pyroxene in our experimental assemblages (9 – 18 wt.%) resulted in 1 and 2 µm absorption band center positions consistent with synthetic clinopyroxene. The clinopyroxene absorptions are present regardless of specific mineral modes and the presence of either olivine or spinel. These results suggest that impact melt crystallization will produce clinopyroxene-bearing lithologies, the presence of which masks spectral contributions from coexisting spinel and olivine. Assuming that the trace amounts of spinel observed in our experiments could be concentrated and isolated from the mafic silicates by convection or density settling in the impact melt sheet, the spinel-rich areas would still be proximally associated with the remaining silicate-dominated assemblage exhibiting strong clinopyroxene spectral signatures. We conclude that impact melting of the lunar crust can explain rare cases of PSA in association with clinopyroxene. Previous investigations of magma-wallrock interactions [2] demonstrate that small plagioclase-contaminated regions of an ultramafic intrusion can concentrate spinel whereas larger portions of the same intrusion remain relatively uncontaminated and yield olivine and orthopyroxene, consistent with the more common occurrence of PSAs in association with orthopyroxene ±olivine in the remote sensing database (e.g., Moscoviense Basin) [4].

petrology↗

Simulation of the Charged Particle Deflection From the Sweeping Magnet Array in the Lunar Environment Heliospheric X-Ray Imager

The Lunar Environment heliospheric X-ray Imager (LEXI) is an instrument built to image x-rays from solar wind charge exchange in Earth’s magneto sheath. Monitoring the position of the magnetopause at the inner boundary of the magneto sheath allows us to understand how magnetic reconnection regulates how energy from the solar wind is deposited into Earth’s magnetosphere. LEXI is part of an upcoming lunar lander mission set to land in Mare Crisium. To repel unwanted charged particles, the instrument carries a permanent magnet array composed of 48 neodymium magnets. The array was designed to maximize charged particle deflection while minimizing stray magnetic fields, which could impact other instruments or spacecraft operation. A Runge–Kutta-based fully kinetic particle tracing model was created to evaluate the effectiveness of LEXI’s unique charged particle deflector array. Combined with the other particle suppression measures of the instrument, including physical structures and filters, the simulations show proton and electron transmission to the LEXI detector is expected to be sufficiently reduced to allow successful imaging. The flexible simulation model can be generalized to be used in examining the magnetic deflector array effectiveness of other instruments whose signals could be compromised by unwanted charged particle contamination.

Space environment effects↗

Calibration and Sequence Development Status for the Sample Analysis at Mars Investigation on the Mars Science Laboratory

The measurement goals of the Sample Analysis at Mars (SAM) instrument suite on the "Curiosity" Rover of the Mars Science Laboratory (MSL) include chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples [1,2]. SAM directly supports the ambitious goals of the MSL mission to provide a quantitative assessment of habitability and preservation in Gale crater by means of a range of chemical and geological measurements [3]. The SAM FM combined calibration and environmental testing took place primarily in 2010 with a limited set of tests implemented after integration into the rover in January 2011. The scope of SAM FM testing was limited both to preserve SAM consumables such as life time of its electromechanical elements and to minimize the level of terrestrial contamination in the SAM instrument. A more comprehensive calibration of a SAM-like suite of instruments will be implemented in 2012 with calibration runs planned for the SAM testbed. The SAM Testbed is nearly identical to the SAM FM and operates in a ambient pressure chamber. The SAM Instrument Suite: SAM's instruments are a Quadrupole Mass Spectrometer (QMS), a 6-column Gas Chromatograph (GC), and a 2-channel Tunable Laser Spectrometer (TLS). Gas Chromatography Mass Spectrometry is designed for identification of even trace organic compounds. The TLS [5] secures the C, H, and O isotopic composition in carbon dioxide, water, and methane. Sieved materials are delivered from the MSL sample acquisition and processing system to one of68 cups of the Sample Manipulation System (SMS). 59 of these cups are fabricated from inert quartz. After sample delivery, a cup is inserted into one of 2 ovens for evolved gas analysis (EGA ambient to >9500C) by the QMS and TLS. A portion of the gas released can be trapped and subsequently analyzed by GCMS. Nine sealed cups contain liquid solvents and chemical derivatization or thermochemolysis agents to extract and transform polar molecules such as amino acids, nucleobases, and carboxylic acids into compounds that are sufficiently volatile to transmit through the GC columns. The remaining 6 cups contain calibrants. SAM FM Calibration Overview: The SAM FM calibration in the Mars chamber employed a variety of pure gases, gas mixtures, and solid materials. Isotope calibration runs for the TLS utilized 13C enriched C02 standards and 0 enriched CH4. A variety of fluorocarbon compounds that spanned the entire mass range of the QMS as well as C3-C6 hydrocarbons were utilized for calibration of the GCMS. Solid samples consisting of a mixture of calcite, melanterite, and inert silica glass either doped or not with fluorocarbons were introduced into the SAM FM cups through the SAM inlet funnel/tube system.

Mahaffy, Paul R.↗

Investigating Commercial Off-The-Shelf (COTS) Glovebox and Support Components Compared to Custom Curatorial Laboratories

There is a need envisioned to investigate the application of commercial off-the-shelf (COTS) systems as tools that could be used within commercial preliminary curation as the expected space economy is supported and begins to take flight. NASA is involved with supporting and developing the space economy [1] and therefore it’s feasible that at some point, a commercial space company would bring back materials and either store initially, or permanently, within COTS equipment as a stand-in for custom curation laboratories. While utilizing opportunities to explore this capability at NASA-Johnson Space Center (JSC) during the establishment of other laboratories [2] it was realized that cleanliness and/or other properties could be evaluated for these COTS systems during their installation in advanced research facilities that are not ISO-class rated clean rooms. Several aspects of a COTS-Curation system were explored including various gloves for curation manipulation within a negative pressure glovebox (Fig.1), Balazs organic and inorganic contaminant levels testing prior to glovebox ever being used, mode swapping comparison of recirculation vs. single pass, constant monitoring of oxygen (O2) and moisture (H2O) levels in various conditions, etc. To acquire inorganic and organic compound loads inside the glovebox, Balazs wafer testing and gas sampling were implemented. These are standardized analytical tests provided by Balazs™ NanoAnalysis, a division of Air Liquide USA. Deployment of 8-inch silicon wafer witness plates for 24-hours in an undisturbed environment capture the organic compound load and inorganic trace metal contents which can be obtained by Vapor Phase Decomposition Inductively Coupled Plasma Mass Spectrometry (VPD ICP-MS). Balazs gas sample analysis was also performed for better measurements of volatile organic compounds (VOC) in glovebox air analyzed by Thermal Desorption Gas Chromatography Mass Spectrometry (TD GC-MS). These analytical testings were carried out in a controlled ultra high pure (UHP) gaseous nitrogen (N2)-purged environment where oxygen and moisture contents were continuously monitored at certain temperature and pressure. The preliminary outcomes of these testings are promising. The COTS systems appear to maintain the steady-state controlled environment for days, if not weeks, with uninterrupted gaseous N2-supply which was operated from a standard medium pressure LN2 250L 230L dewar, exchanged as needed. The outgassing load can be maintained by selecting the glove materials that have the least outgassing and particle shedding performances. Further experiments will be considered to validate the preliminary findings. While this project is exploratory, it is not intended as an endorsement by NASA Curation for approved materials or usage for advanced curatorial activities. NASA does not endorse nor promote any one particular product or company. References: [1] McCubbin F. M. et al. (2019) Space Science Reviews 215:A48. [2] Lewis, E.K. et. al (2024) LPSC LV, Abstract #2457.

Curation↗

Corrosion Prevention in Copper Combustion Chamber Liners of Liquid Oxygen/Methane Booster Engines

Prior research conducted by United Technologies Research Center and Rockwell International Rocketdyne Division encountered severe copper corrosion while flowing hydrocarbon fuels through copper cooling tubes. These experimental results have very important implications for the development of low-cost, regeneratively cooled, oxygen/hydrocarbon bipropellant booster engines. Aerojet TechSystems undertook a program sponsored by NASA/Lewis Research Center in 1986 with two objectives: (1) to define the corrosive interaction process that occurs between hydrocarbon fuels and copper combustion chamber liner materials, using both static and dynamic test methods, and (2) to identify and demonstrate protective measures against this corrosive process. The results of the first program task demonstrated that the most damaging corrosive process was caused by trace amounts of sulfur-containing impurities in the hydrocarbon fuel which react with the copper chamber liner material to form cuprous sulfide (Cu2S), as reported in Paper No. AlAA 88-3215. Experiments were conducted which demonstrated this corrosive process with Mil-Spec RP-1, propane, and methane fuels in contact with OFHC, NASA-Z, and ZrCu coppers. The preliminary results of the second program task demonstrated that electrodeposited gold and platinum coatings held promise of preventing corrosion of copper chamber liners by methane contaminated with sulfur-containing impurities, as reported in Paper No. AIAA 89-2738. Experiments were conducted which demonstrated greatly reduced corrosion of copper by hydrogen sulfide (H2S) and methyl mercaptan (CH3SH) as measured impurities in methane. This paper presents the concluding, confirmatory results from the second program task. The efficacy of a protective gold coating on NASA-Z copper cooling channel walls was conclusively demonstrated. Tests were conducted in the Aerojet Carbothermal Test Facility which provide realistic simulations of booster engine cooling channel conditions such as temperature, pressure, flow velocity, and heat flux. Dynamic test series were performed with methane containing 5 and 10 ppm (by volume) hydrogen sulfide. Gold-plated and unplated copper alloy specimens were evaluated. The tests demonstrated that gold coatings were effective in preventing corrosion of the copper. Posttest metallographic examinations of the unplated specimens showed severe corrosion as a result of reaction with the sulfur containing contaminant in the fuel. In contrast, posttest metallographic examination of the gold-coated specimens showed no corrosion under similar operating conditions. The findings from metallurgical and chemical analyses of the copper specimens, chemical analysis of the methane, and description of all test conditions are provided. Conclusions are reached as to the efficacy of the plating methods and the effectiveness of the metal coatings in the prevention of corrosion in hydrocarbon-fueled booster engine combustion chamber liners.

S D Rosenberg↗

A Large, Deep 3 Deg2 Survey of Hα, [OIII], and [OII] Emitters from LAGER: Constraining Luminosity Functions

We present our measurements of the Hα, [OIII], and [O II] luminosity functions as part of the Lyman Alpha Galaxies at Epoch of Reionization (LAGER) survey using our samples of 1577 z=0.47Hα-, 3933 z=0.93 [O III]-, and 5367 z=1.59 [O II]-selected emission line galaxies in a 3 deg2 single, CTIO/Blanco DECam pointing of the COSMOS field. Our observations reach 5σ depths of 8.2 × 10−18 erg s−1 cm−2 and comoving volumes of (1−7) × 105 Mpc3 making our survey one of the deepest narrow-band surveys. We select our emission line galaxies via spectroscopic confirmation, photometric redshifts, and colour–colour selections. We measure the observed luminosity functions for each sample and find best fits of φ* = 10−3.16+0.09 −0.09 Mpc−3and L* = 1041.72+0.09 −0.09 erg s−1 for Hα, φ* = 10−2.16+0.10−0.12 Mpc−3 and L* = 1041.38+0.07 −0.06 erg s−1 for [O III], and φ* = 10−1.97+0.07−0.07 Mpc−3 and L* = 1041.66+0.03−0.03 erg s−1 for [OII], with α fixed to −1.75, −1.6, and −1.3, respectively. An excess of bright >1042 erg s−1 [O III] emitters is observed and may be due to active galactic nucleus (AGN) contamination. Corrections for dust attenuation are applied assuming AHα = 1 mag. We also design our own empirical restframe g − r calibration using SDSS DR12 data, test it against our z = 0.47 Hα emitters with zCOSMOS 1D spectra, and calibrate it for (g − r) between −0.8 and 1.3 mag. Dust and AGN corrected star formation rate densities (SFRDs) are measured as log10ρSFR/(Msun yr−1 Mpc−3)=−1.63 ± 0.04, −1.07 ± 0.06, and −0.90 ± 0.10 for Hα, [OIII], and [O II], respectively. We find our [O III] and [O II] samples fully trace cosmic star formation activity at their respective redshifts in comparison to multiwavelength SFRDs, while the Hα sample traces ∼70 per cent of the total z = 0.47 SFRD.

galaxies↗

The Surfaces of Pluto and Charon

Much of the surface of Pluto consists of high-albedo regions covered to an unknown depth by Beta-N2, contaminated with CH4, CO, and other molecules. A portion of the exposed surface appears to consist of solid H2O. The remainder is covered by lower albedo material of unknown composition. The N2 ice may occur as polar caps of large extent, leaving ices and other solids of lower volatility in the equatorial regions. The low-albedo material found primarily in the equatorial regions may consist in part of solid hydrocarbons and nitriles produced from N2 and CH4 in the atmosphere or in the surface ices. Alternatively, it may arise from deposition from impacting bodies and/or the chemistry of the impact process itself. Charon's surface is probably more compositionally uniform than that of Pluto, and is covered by H2O ice with possible contaminants or exposures of other materials that are as yet unidentified. The molecular ices discovered on Pluto and Charon have been identified from near-infrared spectra obtained with Earth-based telescopes. The quantitative interpretation of those data has been achieved through the computation of synthetic spectra using the Hapke scattering theory and the optical constants of various ices observed in the laboratory. Despite limitations imposed by the availability of laboratory data on ices in various mixtures, certain specific results have been obtained. It appears that CH4 and CO are trace constituents, and that some fraction of the CH4 (and probably the CO) on Pluto is dissolved in the matrix of solid N2. Pure CH4 probably also occurs on Pluto's surface, allowing direct access to the atmosphere. Study of the nitrogen absorption band at 2.148 micrometers shows that the temperature of the N2 in the present epoch is 40 +/-2 K. The global temperature regime of Pluto can be modeled from observations of the thermal flux at far-infrared and millimeter wavelengths. The low-albedo equatorial regions must be significantly warmer than the polar regions covered by N2 (at T = 40 K) to account for the total thermal flux measured. At the present season, the diurnal skin depth of the insolation-driven thermal wave is small, and the observed mm-wave fluxes may arise from a greater depth. Alternatively, the mm-wave flux may arise from the cool, sublimation source region. The surface microstructure in the regions covered by N2 ice is likely governed by the sintering properties of this highly volatile material. The observed nitrogen infrared band strength requires that expanses of the surface be covered with cm-sized crystals of N2. Grains of H2O ice on Charon, in contrast, are probably of order 50 micrometers in size, and do not metamorphose into larger grains at a significant rate. Because of the similarities in size, density, atmosphere and surface composition between Pluto and Neptune's satellite Triton, the surface structures observed by Voyager on Triton serve as a plausible paradigm for what might be expected on Pluto. Such crater forms, tectonic structures, aeolian features, cryovolcanic structures, and sublimation-degraded topography as are eventually observed on Pluto and Charon by spacecraft will give information on their interior compositions and structures, as well as on the temperature and wind regimes over the planet's extreme seasonal cycle.

Cruikshank, Dale P.↗

Abundance of 17 trace elements in carbonaceous chondrites.

Seventeen trace elements (Ag, Au, Bi, Br, Cd, Cs, Ge, In, Ir, Rb, Re, Sb, Se, Te, Tl, U, and Zn) were measured by neutron activation analysis in eight C1 samples (1 Alais, 3 Ivuna, 4 Orgueil and in three C2 samples (one each of Mighei, Murchison, Murray). The results show far less scatter than earlier literature data. The standard deviation of a single measurement from the mean of eight C1 samples lies between 2 and 14%, except for the following four elements: Au, Ag, Rb, and Br. The first two probably reflect contamination and sample heterogeneity, the last two, analytical error. Apparently C1 chondrites have a far more uniform composition than some authors have claimed.

Kraehenbuehl, U.↗

The Space Station neutral gas environment and the concomitant requirements for monitoring

At 340 km, for typical conditions, the neutral atmospheric density is several times 10E8/cc and is thus more abundant than the ionized component by several factors of 10. At that altitude, the principal series is atomic oxygen with 10 percent N2, and 1 percent He, and trace amounts of O2, H, N, NO, and Ar. The constituent densities are highly variable with local time, latitude, and geophysical indices. The physical interaction with surfaces at orbital velocity leads to large buildup of density on forward faces and great depletions in the wakes of objects. Chemical reactions lead to major modifications in constituent densities as in the case of the conversion of most colliding oxygen atoms to oxygen bearing molecules. The neutral environment about an orbiting body is thus a complex product of many variables even without a source of neutral contaminants. The addition of fluxes of gases emanating from the orbiting vehicle, as will be the case for the Space Station, with the associated physical and chemical interactions adds another level of complexity to the character of the environment and mandates a sophisticated measurement capability if the neutral environment is to be quantitatively characterized.

Carignan, George↗

Geochemistry of amphibolites from the Kolar Schist Belt

How the Nd isotope data suggest that the amphibolites from the schist belt were derived from long-term depleted mantle sources at about 2.7 Ga is described. Trace element and Pb isotope data from the amphibolites also suggest that the sources for the amphibolites on the western and eastern sides of the narrow schist belt were derived from different sources. The Pb data from one outcrop of the central tholeiitic amphibolites lies on a 2.7 Ga isochron with a low model. The other amphibolites (W komatiitic, E komatiitic, and E tholeiitic) do not define isochrons, but suggest that they were derived from sources with distinct histories of U/Pb. There is some suggestion that the E komatiitic amphibolites may have been contaminated by fluids carrying Pb from a long-term, high U/Pb source, such as the old granitic crust on the west side of the schist belt. This is consistent with published galena Pb isotope data from the ore lodes within the belt, which also show a history of long-term U/Pb enrichment.

Balakrishnan, S.↗

Satellite data - Analysis techniques and applications to meteorology

The history of meteorological satellites is traced, together with current instrumental and data analysis capabilities. Photographs taken from rockets launched in the late 1950s encouraged placing spacecraft such as the Nimbus I in sunsynchronous orbit beginning in 1964, and eventually the GOES, GMS, TIROS and Meteosat spacecraft into GEO in the 1970s. Visible, UV, IR and microwave sensors provide data on cloud patterns, wind fields, vertical temperature and humidity profiles and the surface temperature. Corrections have been developed in the data analyses programs to account for the atmospheric effects on upwelling radiation, fractional cloudiness, cloud-top heights and cloud contamination factors.

Szejwach, G.↗

Great New Insights from Failed Experiments, Unanticipated Results and Embracing Controversial Observations

Experimental data and observations, whether telescopic or analytical, are never wrong, though data derived from such sources can be misinterpreted or applied inappropriately to derive conclusions that are incorrect. Given that nature always behaves according to the laws of physics and chemistry, rather than according to currently popular models and theories, experimental results should always be considered correct even when the results are far from those that one might initially expect. We discuss a number of cases where the results of experiments, even one carried out as a simple calibration measure, produced wildly different results that generally required many years of effort or contemplation to understand. On the positive side, exploration of the circumstances that produced the errant results often led to new and interesting insights concerning processes that might occur in natural environments and that were well worth the effort involved. Specifically, we show how an experiment that "failed" due to a broken conductor led to experiments that made the first refractory oxide solids containing mass independently fractionated oxygen isotopes and to 1998 predictions of the oxygen isotopic composition of the sun that were confirmed by the analysis of Genesis samples in 2011. We describe a calibration experiment that unexpectedly produced single magnetic domain iron particles. We discuss how tracking down a persistent source of "contamination" in experiments intended to produce amorphous iron and magnesium silicate smokes led to a series of studies on the synthesis of carbonaceous grain coatings that turn out to be very efficient Fischer-Tropsch catalysts and have great potential for trapping the planetary noble gases found in meteorites. We describe how models predicting the instability of silicate grains in circumstellar environments spurred new measurements of the vapor pressure of SiO partially based on previous experiments showing unexpected but systematic non-equilibrium behavior instead of the anticipated equilibrium products resembling meteoritic minerals. We trace the process that led from observations of the presence of crystalline minerals detected in the comae of some comets to the 1999 prediction of large-scale circulation of materials from the hot, innermost regions of the solar nebula out to the cold dark nebular environments where comets form. This large-scale circulation was ultimately confirmed by analyses of highly refractory Stardust samples collected from the Kuiper Belt Comet Wild 2. Finally we discuss a modern and still unresolved conflict between the assumptions built into three well known processes: the CO Self Shielding Model for mass independent isotopic fractionation of oxygen in solar system solids, rapid and thorough mixing within the solar nebula, and the efficient conversion of CO into organic coatings and volatiles on the surfaces of nebular grains via Fischer-Tropsch-type processes.

controversial↗

Searching for Extraterrestrial Amino Acids in a Contaminated Meteorite: Amino Acid Analyses of the Canakkale L6 Chondrite

Amino acids can serve as important markers of cosmochemistry, as their abundances and isomeric and isotopic compositions have been found to vary predictably with changes in parent body chemistry and alteration processes. Amino acids are also of astrobiological interest because they are essential for life on Earth. Analyses of a range of meteorites, including all groups of carbonaceous chondrites, along with H, R, and LL chondrites, ureilites, and a martian shergottite, have revealed that amino acids of plausible extraterrestrial origin can be formed in and persist after a wide range of parent body conditions. However, amino acid analyses of L6 chondrites to date have not provided evidence for indigenous amino acids. In the present study, we performed amino acid analysis on larger samples of a different L6 chondite, Canakkale, to determine whether or not trace levels of indigenous amino acids could be found. The Canakkale meteor was an observed fall in late July, 1964, near Canakkale, Turkey. The meteorite samples (1.36 and 1.09 g) analyzed in this study were allocated by C. Y. Ornek, along with a soil sample (1.5 g) collected near the Canakkale recovery site.

Burton, A. S.↗

Tracing the Cosmological Evolution of Stars and Cold Gas with CMB Spectral Surveys

A full account of galaxy evolution in the context of ΛCDM cosmology requires measurements of the average star-formation rate (SFR) and cold gas abundance across cosmic time. Emission from the CO ladder traces cold gas, and [C II] fine structure emission at 158 μm traces the SFR. Intensity mapping surveys the cumulative surface brightness of emitting lines as a function of redshift, rather than individual galaxies. CMB spectral distortion instruments are sensitive to both the mean and anisotropy of the intensity of redshifted CO and [C II] emission. Large-scale anisotropy is proportional to the product of the mean surface brightness and the line luminosity-weighted bias. The bias provides a connection between galaxy evolution and its cosmological context, and is a unique asset of intensity mapping. Cross-correlation with galaxy redshift surveys allows unambiguous measurements of redshifted line brightness despite residual continuum contamination and interlopers. Measurement of line brightness through cross-correlation also evades cosmic variance and suggests new observation strategies. Galactic foreground emission is ≈10(exp 3) times larger than the expected signals, and this places stringent requirements on instrument calibration and stability. Under a range of assumptions, a linear combination of bands cleans continuum contamination sufficiently that residuals produce a modest penalty over the instrumental noise. For PIXIE, the 2σ sensitivity to CO and [C II] emission scales from »5 ´ 10-2 kJy sr-1 at low redshift to ≈2 kJy sr(exp -1) by reionization.

Switzer, Eric R.↗

Assessing the Oxygen Permeability of Candidate Asteroid Sample Containers With Optochemical Sensors

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center currently curates 500 mg (10%) of carbonaceous asteroid Ryugu regolith collected by the Japan Aerospace and Exploration Agency’s Hayabusa II spacecraft and returned to Earth in 2021. In September 2023, NASA’s OSIRIS-REx spacecraft returned at least 70 grams of regolith collected from the surface of Carbonaceous Asteroid Bennu. These new astromaterials collections are stored and handled in gloveboxes and desiccators that are continuously purged with ultrapure nitrogen in order to minimize contamination and alteration of extraterrestrial samples from terrestrial environments, e.g., reaction with terrestrial oxygen and water. Ito et al. have previously reported on the development of containers to transport samples between facilities in inert, sealed environments; Hayabusa2 samples allocated to investigators by JAXA’s Extraterrestrial Sample Curation Center (ESCuC) are shipped in these Facility-to-Facility Transfer Containers (FFTCs). NASA curation has also been investigating sealed containers for storage, transportation, and allocation of Bennu and Ryugu regolith in sealed anoxic environments. In order to assess the ability of candidate sample containers to maintain nitrogen environments, we have utilized optochemical sensors to measure trace oxygen levels within sealed volumes.

C J Snead↗

Contamination and Radiation Effects on Nonlinear Crystals for Space Laser Systems

Space Lasers are vital tools for NASA s space missions and military applications. Although, lasers are highly reliable on the ground, several past space laser missions proved to be short-lived and unreliable. In this communication, we are shedding more light on the contamination and radiation issues, which are the most common causes for optical damages and laser failures in space. At first, we will present results based on the study of liquids and subsequently correlate these results to the particulates of the laser system environment. We present a model explaining how the laser beam traps contaminants against the optical surfaces and cause optical damages and the role of gravity in the process. We also report the results of the second harmonic generation efficiency for nonlinear optical crystals irradiated with high-energy beams of protons. In addition, we are proposing to employ the technique of adsorption to minimize the presence of adsorbing molecules present in the laser compartment.

Abdeldayem, Hossain A.↗

Comprehensive analysis of airborne contaminants from recent Spacelab missions

The Shuttle experiences unique air contamination problems because of microgravity and the closed environment. Contaminant build-up in the closed atmosphere and the lack of a gravitational settling mechanism have produced some concern in previous missions about the amount of solid and volatile airborne contaminants in the Orbiter and Spacelab. Degradation of air quality in the Orbiter/Spacelab environment, through processes such as chemical contamination, high solid-particulate levels, and high microbial levels, may affect crew performance and health. A comprehensive assessment of the Shuttle air quality was undertaken during STS-40 and STS-42 missions, in which a variety of air sampling and monitoring techniques were employed to determine the contaminant load by characterizing and quantitating airborne contaminants. Data were collected on the airborne concentrations of volatile organic compounds, microorganisms, and particulate matter collected on Orbiter/Spacelab air filters. The results showed that STS-40/42 Orbiter/Spacelab air was toxicologically safe to breathe, except during STS-40 when the Orbiter Refrigerator/Freezer unit was releasing noxious gases in the middeck. On STS-40, the levels of airborne bacteria appeared to increase as the mission progressed; however, this trend was not observed for the STS-42 mission. Particulate matter in the Orbiter/Spacelab air filters was chemically analyzed in order to determine the source of particles. Only small amounts of rat hair and food bar (STS-40) and traces of soiless medium (STS-42) were detected in the Spacelab air filters, indicating that containment for Spacelab experiments was effective.

Matney, M. L.↗

Gas chromatography/ion mobility spectrometry as a hyphenated technique for improved explosives detection and analysis

Ion Mobility Spectrometry (IMS) is currently being successfully applied to the problem of on-line trace detection of plastic and other explosives in airports and other facilities. The methods of sample retrieval primarily consist of batch sampling for particulate residue on a filter card for introduction into the IMS. The sample is desorbed into the IMS using air as the carrier and negative ions of the explosives are detected, some as an adduct with a reagent ion such as Cl(-). Based on studies and tests conducted by different airport authorities, this method seems to work well for low vapor pressure explosives such as RDX and PETN, as well as TNT that are highly adsorptive and can be found in nanogram quantities on contaminated surfaces. Recently, the changing terrorist threat and the adoption of new marking agents for plastic explosives has meant that the sample introduction and analysis capabilities of the IMS must be enhanced in order to keep up with other detector developments. The IMS has sufficient analytical resolution for a few threat compounds but the IMS Plasmogram becomes increasingly more difficult to interpret when the sample mixture gets more complex.

Mercado, AL↗