At least 487 records · Page 27

Algorithm for Estimating the Plume Centerline Temperature and Ceiling Jet Temperature in the Presence of a Hot Upper Layer

The experiments were designed to provide insight into the behavior of jet fuel fires in aircraft hangars and to study the impact of these fires on the design and operation of a variety of fire protection systems. As a result, the test series included small fires designed to investigate the operation of UV/IR detectors and smoke detectors as well as large fires which were used to investigate the operation of ceiling mounted heat detectors and sprinklers. The impact of the presence or absence of draft curtains was also studied in the 15 m hangar. It is shown that in order to predict the plume centerline temperature within experimental uncertainty, the entrainment of the upper layer gas must be modeled. For large fires, the impact of a changing radiation fraction must also be included in the calculation. The dependence of the radial temperature profile of the ceiling jet as a function of layer development is demonstrated and a ceiling jet temperature algorithm which includes the impact of a growing layer is developed.

ALGORITHMS↗

Estimation of Biomass Fire Temperature and Areal Extent from Calibrated AVIRIS Spectra

This paper describes an approach to derive a range of biomass fire parameters from spectra measured by NASA's Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). AVIRIS measures images of the upwelling spectral radiance from 400 to 2500 nm at 10nm intervals. Images are measured of 11 by up to 100 km with 20 by 20 m spatial resolution.

Biomass AVRIS biomass fire smoke cloud aerosol and↗

A Method for Obtaining High Time and Spatial Resolution Convective Cloud Top Data for the TTL

A method for obtaining high time and spatial resolution convective cloud top data for the TTL Leonhard Pfister, Eric Jensen, Rei Ueyama, Eliot Atlas, and Maria Navarro Convective systems in the tropics have a maximum in the cloud top altitude distribution of about 13.5 km. However, there is a significant tail to this distribution -- a few percent reach the cold point tropopause (CPT) at 16.5 km, and there has been clear evidence of convective mass deposited as high as 19 km in the tropics. The region between 13.5 km and the cold point tropopause is transitional, between the free tropical troposphere where convective mixing dominates, and the stratosphere where slow upward ascent dominates. In this region (the Tropical Tropopause Layer), convective injection, slow ascent, and mixing from midlatitudes all have similar time scales. So, even though only a few percent of convective systems reach the CPT, convection is important. Space Based Lidar and cloud radar measurements have yielded information about long term average statistical distributions of cloud altitude as a function of location. However, we also need time-dependent cloud top altitude and cloud top potential temperature information, primarily to understand the water vapor and TTL cloud distributions. This is because the effect of convection depends on the local temperature, and on the subsequent temperature history. Time dependent cloud top information is also needed to understand short-lived tracers because cross-isentropic flow is time and space dependent. This paper presents a method of obtaining time and space dependent convective cloud top theta (and altitude) information using 3-hourly geostationary brightness temperature data, coupled with global 3 -hourly rainfall estimates and temperature analyses. We explore different mixing algorithms to obtain the most reasonable agreement with near-simultaneous observations by cloudsat and calipso. Observations of short-lived tracers from ATTREX, coupled with short-term trajectories are used to test the method's accuracy. An important caveat is the ambiguity of evaluating convective cloud top altitudes under from combined cloudsat and calipso measurements.

cold point tropopause (CPT)↗

Estimation of tropical forest canopy temperatures, thermal response numbers, and evapotranspiration using an aircraft-based thermal sensor

Thermal infrared Multispectral Scanner (TIMS) data were collected at a resolution of 5 to 10 m from a tropical rain forest over an elevation gradient from 35 to 2700 m in the Braulio Carrillo National Park in Costa Rica. Flight lines were repeated with a 15 to 30 minute time difference for measurement of forest canopy thermal response over time. Concurrent radiosonde measurements of atmospheric profiles of air temperature and moisture provided inputs to LOWTRAN6 for atmospheric radiance corrections of the TIMS data. Techniques for using calibrated aircraft-based thermal scanner data to examine tropical forest canopy thermal properties are described. Forest canopy temperature changes over time assessed between repeated, duplicated flight lines were combined with estimates of surface radiative energy measurements from towers above the forest canopy to determine temperature spatial variability, calculate Thermal Response Numbers (TRN), and estimate evapotranspiration along the elevation gradient from selected one hectare forest inventory plots.

Luvall, Jeffrey C.↗

Conditions of origin of natural diamonds of peridotite affinity

Studies of mineral inclusions in natural diamonds and rare diamondiferous xenoliths from kimberlites show that most diamonds are associated with a dunite or harzburgite paragenesis. The diamondiferous periodites and dunites have predominantly coarse or tabular textures that suggest low-temperature (less than 1100 C) equilibration. Application of the K(D) Fe/Mg(Ga/Ol) geothermometer of O'Neill and Wood to analytical data for the minerals in these rocks shows that most have equilibrated below 1100 C. Application of this thermometer to pairs of olivine and garnet crystals included in individual diamonds indicates that the diamonds have crystallized in the range 900-1300 C, with a majority of estimated equilibration temperatures falling in the range below 1150 C. Comparison of these estimates of equilibration temperature with the zone of invariant vapor composition solidus for kimberlite and garnet lherzolite determined by Eggler and Wendlandt (1979) suggests that many diamonds may have formed in subsolidus events.

Boyd, F. R.↗

Developing an Effective Model for Predicting Spatially and Temporally Continuous Stream Temperatures from Remotely Sensed Land Surface Temperatures

Although water temperature is important to stream biota, it is difficult to collect in a spatially and temporally continuous fashion. We used remotely-sensed Land Surface Temperature (LST) data to estimate mean daily stream temperature for every confluence-to-confluence reach in the John Day River, OR, USA for a ten year period. Models were built at three spatial scales: site-specific, subwatershed, and basin-wide. Model quality was assessed using jackknife and cross-validation. Model metrics for linear regressions of the predicted vs. observed data across all sites and years: site-specific r2 = 0.95, Root Mean Squared Error (RMSE) = 1.25 °C; subwatershed r2 = 0.88, RMSE = 2.02 °C; and basin-wide r2 = 0.87, RMSE = 2.12 °C. Similar analyses were conducted using 2012 eight-day composite LST and eight-day mean stream temperature in five watersheds in the interior Columbia River basin. Mean model metrics across all basins: r2 = 0.91, RMSE = 1.29 °C. Sensitivity analyses indicated accurate basin-wide models can be parameterized using data from as few as four temperature logger sites. This approach generates robust estimates of stream temperature through time for broad spatial regions for which there is only spatially and temporally patchy observational data, and may be useful for managers and researchers interested in stream biota.

McNyset, Kristina↗

CORONAL SEISMOLOGY USING EIT WAVES: ESTIMATION OF THE CORONAL MAGNETIC FIELD STRENGTH IN THE QUIET SUN

Coronal EIT waves have been observed for many years. The nature of EIT waves is still contentious, however, there is strong evidence that some of them might be fast magnetosonic waves, or at least have a fast magnetosonic wave component. The fast magnetosonic wave speed is formed from two components; the Alfven speed (magnetic) and the sound speed (thermal). By making measurements of the wave speed, coronal density and temperature it is possible to calculate the quiet-Sun coronal magnetic field strength through coronal seismology. In this paper, we investigate an EIT wave observed on 2009 February 13 by the SECCHI/EUVI instruments on board the STEREO satellites. The wave epicenter was observed at disk center in the STEREO B (Behind) satellite. At this time, the STEREO satellites were separated by approximately 90 deg., and as a consequence the STEREO A (Ahead) satellite observed the wave on the solar limb. These observations allowed us to make accurate speed measurements of the wave. The background coronal density was derived through Hinode/Extreme-ultraviolet Imaging Spectrometer observations of the quiet Sun and the temperature was estimated through the narrow temperature response in the EUVI bandpasses. The density, temperature, and speed measurements allowed us to estimate the quiet-Sun coronal magnetic field strength to be approximately 0.7 {+-} 0.7 G.

79 ASTRONOMY AND ASTROPHYSICS↗

CMB lensing and primordial squeezed non-gaussianity

Squeezed primordial non-Gaussianity can strongly constrain early-universe physics, but it can only be observed on the CMB after it has been gravitationally lensed. We give a new simple non-perturbative prescription for accurately calculating the effect of lensing on any squeezed primordial bispectrum shape, and test it with simulations. We give the generalization to polarization bispectra, and discuss the effect of lensing on the trispectrum. We explain why neglecting the lensing smoothing effect does not significantly bias estimators of local primordial non-Gaussianity, even though the change in shape can be ∼>10%. We also show how τ{sub NL} trispectrum estimators can be well approximated by much simpler CMB temperature modulation estimators, and hence that there is potentially a ∼ 10–30% bias due to very large-scale lensing modes, depending on the range of modulation scales included. Including dipole sky modulations can halve the τ{sub NL} error bar if kinematic effects can be subtracted using known properties of the CMB temperature dipole. Lensing effects on the g{sub NL} trispectrum are small compared to the error bar. In appendices we give the general result for lensing of any primordial bispectrum, and show how any full-sky squeezed bispectrum can be decomposed into orthogonal modes of distinct angular dependence.

79 ASTRONOMY AND ASTROPHYSICS↗

Upper bounds for 21st-century surface air temperatures in the Western United States

The last decade has seen a large number of severe heatwaves that were unprecedented in the observational record, highlighting challenges associated with observationally-based statistical quantification of the likelihood and magnitude of future extreme temperatures. An alternative to such probabilistic assessments is identification of upper bounds that quantify the hottest surface air temperatures that can possibly be achieved by the end of the 21st century. Theory, simulations, and observational analyses support the existence of a finite upper bound for surface air temperature; however, estimates for future upper-bound values that are realistic and usable for planning remain unavailable. Here, we combine atmospheric theory with large ensembles of dynamically downscaled projections to estimate historical and end-of-century upper bounds for surface air temperatures. A number of physical mechanisms can influence upper bounds, and at the end of the 21st century, estimates based on mechanisms that yield more moderate upper-bounds produce values around 60∘C for much of the Western United States and in excess of 80∘C for the hottest parts of the domain. Even cooler high-altitude locations have end-of-century upper bounds over 50∘C. Although these upper-bound estimates might seem implausibly large, increases in the upper bounds over the 21st century are similar to increases in dynamically downscaled peak surface temperatures after adjusting those downscaled temperatures to eliminate the possibly biased model trends in surface specific humidity. While upper bound estimates are high relative to historical observations, they nonetheless suggest that heatwave intensity risk is bounded, with uncertainty dominated by projections of surface and upper-level humidity.

Risser, Mark D↗

Estimation of radiative properties and temperature distributions in coal-fired boiler furnaces by a portable image processing system

This paper presented an experimental investigation on the estimation of radiative properties and temperature distributions in a 670 t/h coal-fired boiler furnace by a portable imaging processing system. The portable system has been calibrated by a blackbody furnace. Flame temperatures and emissivities were measured by the portable system and equivalent blackbody temperatures were deduced. Comparing the equivalent blackbody temperatures measured by the portable system and the infrared pyrometer, the relative difference is less than 4%. The reconstructed pseudo-instantaneous 2-D temperature distributions in two cross-sections can disclose the combustion status inside the furnace. The measured radiative properties of particles in the furnace proved there is significant scattering in coal-fired boiler furnaces and it can provide useful information for the calculation of radiative heat transfer and numerical simulation of combustion in coal-fired boiler furnaces. The preliminary experimental results show this technology will be helpful for the combustion diagnosis in coal-fired boiler furnaces. (author)

01 COAL, LIGNITE, AND PEAT↗

A Study on the Temperature Correlation between a Surface of Dry Storage Canister and Spent Fuel Clad - 16446

Analysis of temperature correlation between dry canister surface and spent fuel cladding is performed in this study. The result shows that the spent fuel cladding temperature is possibly estimated using canister surface temperature in normal condition and the result of estimation is depended on analysis model. Two analysis models are designed by using a hypothetical spent fuel model and thermal analysis for the models is performed by using CFX(v11.0) code. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Osmotic potential calculations of inorganic and organic aqueous solutions over wide solute concentration levels and temperatures

Purpose: To demonstrate that the authors’ new “aqueous solution vs pure water” equation to calculate osmotic potential may be used to calculate the osmotic potentials of inorganic and organic aqueous solutions over wide ranges of solute concentrations and temperatures. Currently, the osmotic potentials of solutions used for medical purposes are calculated from equations based on the thermodynamics of the gas laws which are only accurate at low temperature and solute concentration levels. Some solutions used in medicine may need their osmotic potentials calculated more accurately to take into account solute concentrations and temperatures. Methods: The authors experimented with their new equation for calculating the osmotic potentials of inorganic and organic aqueous solutions up to and beyond body temperatures by adjusting three of its factors; (a) the volume property of pure water, (b) the number of “free” water molecules per unit volume of solution, “N{sub f},” and (c) the “t” factor expressing the cooperative structural relaxation time of pure water at given temperatures. Adequate information on the volume property of pure water at different temperatures is available in the literature. However, as little information on the relative densities of inorganic and organic solutions, respectively, at varying temperatures needed to calculate N{sub f} was available, provisional equations were formulated to approximate values. Those values together with tentative t values for different temperatures chosen from values calculated by different workers were substituted into the authors’ equation to demonstrate how osmotic potentials could be estimated over temperatures up to and beyond bodily temperatures. Results: The provisional equations formulated to calculate N{sub f}, the number of free water molecules per unit volume of inorganic and organic solute solutions, respectively, over wide concentration ranges compared well with the calculations of N{sub f} using recorded relative density data at 20 °C. They were subsequently used to estimate N{sub f} values at temperatures up to and excess of body temperatures. Those values, together with t values at temperatures up to and in excess of body temperatures recorded in the literature, were substituted in the authors’ equation for the provisional calculation of osmotic potentials. The calculations indicated that solution temperatures and solute concentrations have a marked effect on osmotic potentials. Conclusions: Following work to measure the relative densities of aqueous solutions for the calculation of N{sub f} values and the determination of definitive t values up to and beyond bodily temperatures, the authors’ equation would enable the accurate estimations of the osmotic potentials of wide concentrations of aqueous solutions of inorganic and organic solutes over the temperature range. The study illustrates that not only solute concentrations but also temperatures have a marked effect on osmotic potentials, an observation of medical and biological significance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

gaia: An R package to estimate crop yield responses to temperature and precipitation

gaia is an open-source R package designed to estimate crop yield shocks in response to annual weather variations and CO 2 concentrations at the country scale for 17 major crops. This innovative tool streamlines the workflow from raw climate data processing to projections of annual shocks to crop yields at the country level, using the response surfaces from an empirical econometric model developed and documented in Waldhoff et al. (2020), which leverages historical weather, CO 2 , and crop yield data for robust empirical fitting for 17 crops. gaia uses these response surfaces with monthly temperature and precipitation projections (e.g., from the Coupled Model Intercomparison Project Phase 6 (CMIP6) (O’Neill et al., 2016) climate data bias-adjusted and statistically downscaled by the ISIMIP3BASD approach (Lange, 2019) in the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP) (Warszawski et al., 2014)) to project yield shocks that can be applied to agricultural productivity changes at the country level for use in multisectoral economic models. The historical and future projections use gridded, country-and-crop specific monthly growing season precipitation and temperature data, aggregated to the national level, and weighted by cropland area derived from the global Monthly Irrigated and Rainfed Crop Areas around the year 2000 (MIRCA2000) dataset (Portmann et al., 2010). These annual, country, and crop-specific yield shocks can be aggregated to different definitions of regions, crop commodities, and time periods, as needed by specific multisectoral economic models. gaia serves as a lightweight, powerful tool that can aid exploration of crop yield responses under a broad range of future climate projections, enhancing human-Earth system analysis capabilities.

60 APPLIED LIFE SCIENCES↗

Cryogenically cooled octupole ion trap for spectroscopy of biomolecular ions

We present here the design of a linear octupole ion trap, suitable for collisional cryogenic cooling and spectroscopy of large ions. The performance of this trap has been assessed using ultraviolet (UV) photofragmentation spectroscopy of protonated dipeptides. At the trap temperature of 6.1 K, the vibrational temperature of the ions reaches 9.1 K, although their estimated translational temperature is ∼150 K. This observation suggests that, despite the significant translational heating by radio-frequency electrical field, vibrational cooling of heavy ions in the octupole is at least as efficient as in the 22-pole ion traps previously used in our laboratory. In contrast to the 22-pole traps, excellent radial confinement of ions in the octupole makes it convenient for laser spectroscopy and boosts the dissociation yield of the stored ions to 30%. Overlap of the entire ion cloud by the laser beam in the octupole also allows for efficient UV depletion spectroscopy of ion–He clusters. The measured electronic spectra of the dipeptides and the clusters differ drastically, complicating a use of UV tagging spectroscopy for structural determination of large species.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature distribution in a laser-heated diamond anvil cell as described by finite element analysis

Finite element analysis (FEA) is a powerful tool for numerically solving partial differential equations over complex geometries and is thus useful for analyzing heat transport in laser-heated diamond anvil cell (LHDAC) experiments. Our models expand on previously published simulations by calculating the volume-averaged temperatures of both the sample and insulation/pressure media under steady-state heating to determine the thermal pressure of the hot sample. Our goal is to produce an accurate relationship between the measured surface temperature of the absorbing sample and the temperature of the transparent insulating media, which is used to determine thermal pressure but susceptible to steep temperature gradients. We find that in doing so, our FEA models of temperature within the pressure/insulation media can differ from simplified estimates of temperature gradients by more than a factor of 2. We also explore temperature-dependent and temperature-independent thermal conductivity models and find that the volume-averaged temperatures differ by up to a factor of 1.3, forcing the predicted thermal pressures determined to also differ by up to a factor of 1.5 at a temperature of 2000 K at 50 GPa for neon. Higher temperatures exacerbate this difference. We also find that unintentional asymmetric sample insertion and sample heating, which are common in LHDAC experiments, do not have a first-order effect on volume-averaged temperatures. The FEA models, available in both Python and FlexPDE, are versatile across different sample geometries, materials, and heat source laser shapes.

Farah, Frederick↗

State-of-the-Art for Hygrothermal Simulation Tools

The hygrothermal (heat and moisture) performance of buildings can be assessed by utilizing simulation tools. There are currently a number of available hygrothermal calculation tools available which vary in their degree of sophistication and runtime requirements. This report investigates three of the most commonly used models (WUFI, HAMT, and EMPD) to assess their limitations and potential to generate physically realistic results to prioritize improvements for EnergyPlus (which uses HAMT and EMPD). The outcome of the study shows that, out of these three tools, WUFI has the greatest hygrothermal capabilities. Limitations of these tools were also assessed including: WUFI’s inability to properly account for air leakage and transfer at surface boundaries; HAMT’s inability to handle air leakage, precipitationrelated moisture problems, or condensation problems from high relative humidity; and multiple limitations for EMPD as a simplified method to estimate indoor temperature and humidity levels and generally not used to estimate the hygrothermal performance of the building envelope materials. In conclusion, out of the three investigated simulation tools, HAMT has the greatest modeling potential, is open source, and we have prioritized specific features that can enable EnergyPlus to model all relevant heat and moisture transfer mechanisms that impact the performance of building envelope components.