Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tensile Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Development of Ultra Small Scale Mechanical Testing and Localized He Implantation for Nuclear Applications

Mechanical properties degradation of components deployed in nuclear applications has been a concern since the deployment of first generation nuclear power plants. Radiation damage along with environmental degradation, elevated temperatures, and long term deployment of nuclear structures pose a challenging environment for all materials in these applications. Traditionally, the mechanical properties are assessed by standardized macroscopic testing methods. While those are providing engineering relevant data these techniques do have limitations, especially on reactor irradiated materials, due to the large size of the samples. Limitations on the amount of radioactivity of large samples must be applied for research applications as they are conducted at universities. In addition it can be difficult to retrieve sufficiently large amounts of material from an operating reactor component. Therefore smaller sample sizes are desirable and reduce the amount of radioactive material which needs to be handled or material which needs to be retrieved. In addition, the number of tests which can be performed on materials irradiated in a test reactor program is limited due to limited space in specific dose and temperature positions. Downsizing of the mechanical test can overcome this issue and perform more tests on the same amount of irradiated materials, reducing the statistical uncertainties. In addition, smaller scale samples allow access to specific regions of interest in a material or component, be it the zone in front of a crack tip or the sampling of very small components like springs or welded areas. In addition ion beam irradiation has become an integral part of nuclear materials research to enhance the understanding of radiation damage in materials in a time and cost effective fashion. The drawback of ion beam irradiation is the small penetration depth of the ions into the material making localized microstructural characterization as well as small scale mechanical testing necessary. Another more fundamental motivation is the fact that since the beginning of electron microscopy, one has been concerned about imaging and quantifying defects in materials. Multiscale tools to image a large range of radiation induced defects have been established starting from atom probe tomography to transmission electron microscopy, up to scattering techniques. Mechanical testing, however, has always been performed on a large scale, and an attempt to match the same scale where a defect is observed with the materials' mechanical property response has not yet been realized. However, the question of separate effects testing on specific radiation induced defects remains and is an additional driving force for small scale mechanical testing. In this work we present an approach for small scale mechanical testing in irradiated materials and the variety of possible test methods developed today. We also present recent efforts of performing localized ion beam implantation to achieve a number of different doses in the same region of interest enhancing comparability and quantification of observed phenomena. It is the intention to give the reader an overview of the different microscale mechanical testing techniques possible today as well as an introduction of a novel ion beam irradiation method using a newly established capability. In this paper we can't discuss all aspects of all small scale mechanical testing of irradiated materials However, It does give an overview over the techniques enabled due to recent effort and enhanced instrument capability. While indentation or micro compression testing has been performed previously tensile testing and ion beam irradiation using the He ion beam microscope are novel approaches not attempted previously. (authors)

36 MATERIALS SCIENCE↗

Mechanical Testing of IN718 Lattice Block Structures

Lattice block construction produces a flat, structurally rigid panel composed of thin ligaments of material arranged in a three-dimensional triangulated truss-like structure. Low-cost methods of producing cast metallic lattice block panels are now available that greatly expand opportunities for using this unique material system in today's high-performance structures. Additional advances are being made in NASA's Ultra Efficient Engine Technology (UEET) program to extend the lattice block concept to superalloy materials. Advantages offered by this combination include high strength, light weight, high stiffness, and elevated temperature capabilities. Recently under UEET, the nickel-based superalloy Inconel 718 (IN718) was investment cast into lattice block panels with great success. To evaluate casting quality and lattice block architecture merit, individual ligaments, and structural subelement specimens were extracted from the panels. Tensile tests, structural compression, and bending strength tests were performed on these specimens. Fatigue testing was also completed for several bend test specimens. This paper first presents metallurgical and optical microscopy analysis of the castings. This is followed by mechanical test results for the tensile ligament tests and the subelement compression and bending strength tests, as well as for the fatigue tests that were performed. These tests generally showed comparable properties to base IN718 with the same heat treatment, and they underscored the benefits offered by lattice block materials. These benefits might be extended with improved architecture such as face sheets.

Krause, David L.↗

Pectin methylesterase selectively softens the onion epidermal wall yet reduces acid-induced creep

De-esterification of homogalacturonan (HG) is thought to stiffen pectin gels and primary cell walls by increasing calcium cross-linking between HG chains. Contrary to this idea, recent studies found that HG de-esterification correlated with reduced stiffness of living tissues, measured by surface indentation. The physical basis of such apparent wall softening is unclear, but possibly involves complex biological responses to HG modification. To assess the direct physical consequences of HG de-esterification on wall mechanics without such complications, we treated isolated onion (Allium cepa) epidermal walls with pectin methylesterase (PME) and assessed wall biomechanics with indentation and tensile tests. In nanoindentation assays, PME action softened the wall (reduced the indentation modulus). In tensile force/extension assays, PME increased plasticity, but not elasticity. These softening effects are attributed, at least in part, to increased electrostatic repulsion and swelling of the wall after PME treatment. Despite softening and swelling upon HG de-esterification, PME treatment alone failed to induce cell wall creep. Instead, acid-induced creep, mediated by endogenous α-expansin, was reduced. We conclude that HG de-esterification physically softens the onion wall, yet reduces expansin-mediated wall extensibility.

59 BASIC BIOLOGICAL SCIENCES↗

The stress corrosion resistance and the cryogenic temperature mechanical properties of annealed Nitronic 60 bar material

Ambient and cryogenic temperature mechanical properties and the ambient temperature stress corrosion properties of annealed, straightened, and centerless ground Nitronic 60 stainless steel alloy bar material are presented. The mechanical properties of longitudinal specimens were evaluated at test temperatures from ambient to liquid hydrogen. The tensile test data indicated increasing strength with decreasing temperature to -196 C. Below liquid nitrogen temperature the smooth tensile and notched tensile strengths decreased slightly while the elongation and reduction of area decreased drastically. The Charpy V-notched impact energy decreased steadily with decreasing test temperature. Stress corrosion tests were performed on longitudinal tensile specimens and transverse C-ring specimens exposed to: alternate immersion in a 3.5% NaCl bath; humidity cabinet; and a 5% salt spray atmosphere. The longitudinal tensile specimens experienced no corrosive attack. Approximately 3/4 of the transverse C-rings exposed to alternate immersion and to salt spray experienced a pitting attack on the top and bottom ends. Additional stress corrosion tests were performed on transverse tensile specimens. No failures occurred in the 90% stressed specimens exposed for 90 days in the alternate immersion and salt spray environments

Montano, J. W. L.↗

Swab Testing Results- HP PA11 Rev 8 Summary

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking.

42 ENGINEERING↗

Aluminum Lithium Alloy 2195 Fusion Welding Improvements with New Filler Wire

A viewgraph presentation outlines NASA Marshall Space Flight Center, Lockheed Martin Michoud Space Systems, and McCook Metals' development an aluminum-copper weld filler wire for fusion welding 2195 aluminum lithium. The aluminum-copper based weld filler wire has been identified as B218, which is the result of six years of weld filler wire development funded by NASA, Lockheed Martin, and McCook Metals. The Super Lightweight External Tank for the NASA Space Shuttle Program consists of 2195 welded with 4043 aluminum-silicon weld filler wire. The B218 filler wire chemistry was developed to produce enhanced 2195 weld and repair weld mechanical properties. An initial characterization of the B218 weld filler wire was performed consisting of initial weld and repair weld evaluation comparing B218 and 4043. The testing involved room temperature and cryogenic tensile testing along with fracture toughness testing. B218 weld filler wire proved to produce enhanced initial and repair weld tensile and fracture properties over 4043. B218 weld filler wire has proved to be a superior weld filler wire for welding 2195 and other aluminum lithium alloys over 4043.

Russell, Carolyn↗

High-Temperature Tensile and Creep Test Results on Thin Wall Tube Specimens of ODS Alloys 14YWT and OFRAC

High-temperature tensile and strain rate jump (SRJ) creep tests were conducted on axial specimens fabricated from thin wall tubes of the oxide dispersion strengthened (ODS) alloys 14YWT and OFRAC. The dimensions of the 14YWT thin wall tube was 10.7 mm OD, 0.5 mm WT and 0.92 m and of the OFRAC thin wall tube was 8.5 mm OD + 0.5 mm WT and 1.78 m in length. The axial specimens fabricated from the thin wall tubes were based on a dual-gauge design with gauge dimensions of 4 mm long and 2 mm wide. The tensile tests were conducted in air at 800ºC, 900ºC and 1,000ºC and the SRJ creep tests were conducted in air at 800ºC. Two axial specimens were used in each tensile and SRJ creep tests. The results of the tensile tests showed much lower yield stress (YS) compared to ultimate tensile strength (UTS) indicative of large work hardening properties. The results showed the UTS of OFRAC was higher than that of 14YWT by ~35 MPa at 800ºC. At 900ºC, the UTS of OFRAC and 14YWT was similar at 900ºC and at 1000ºC, the UTS of 14YWT was higher than that of OFRAC by ~10 MPa. The ductility properties of OFRAC were greater than that of 14YWT with higher values of uniform elongation (UE) and total elongation (TE) at all tensile test temperatures. The creep properties of 14YWT and OFRAC were evaluated by the strain rate jump test method at 800ºC. The stress exponent (n) for creep was obtained from the SRJ test data by plotting the values of the log strain rate against the log stress, which is measured from the stress-strain curve generated during the SRJ test. The results showed the highest stress exponents of n = 19.8 and n = 35.0 were measured from the two SRJ tests on 14YWT. The stress exponent measured from one successful SRJ test on OFRAC was n = 13.3, which was lower than that of 14YWT. Nevertheless, these high values of stress exponent are consistent with ODS ferritic alloys such as 14YWT and OFRAC since they indicate dislocation-particle interactions are the dominant creep mechanism for specific ranges of temperature and stress. The results obtained from the tensile and SRJ creep tests conducted on axial specimens in this study indicate that 14YWT and OFRAC retain high strengths at temperatures up to 1,000ºC and good creep performance at 800ºC.

36 MATERIALS SCIENCE↗

Testing filamentary composites

NOL ring split-dee tensile test has the advantages that the specimen is readily fabricated by winding and the test is performed in a conventional testing machine without special fixtures. Strain gages cannot be mounted, however, and substantial bending moments are introduced.

Dow, N. F.↗

Irradiation of Advanced Cladding Specimens in the High Flux Isotope Reactor: Capsule Designs and Test Matrix

The Advanced Fuels Campaign (AFC) has initiated the Advanced Reactor Cladding (ARC) irradiation campaign to generate irradiation performance data for candidate fuel cladding concepts. The campaign includes a diverse set of ferritic/martensitic steels, oxide dispersion strengthened (ODS) alloys, FeCrAlbased alloys, coated materials, and welded cladding specimens produced through multiple US Department of Energy (DOE) programs and international collaborations. Three complementary experimental thrusts comprise the campaign: tensile testing (ARC Tensile) to rapidly screen candidate alloys, fracture toughness testing (ARC Fracture) to evaluate irradiation effects on crack resistance, and tubular weld testing (ARC Weld) to quantify irradiation-induced changes in the mechanical performance of end cap welds. This report documents the irradiation campaign design, including the selected materials, specimen types, irradiation matrix, and capsule designs for irradiation within the High Flux Isotope Reactor (HFIR). A total of 14 irradiation capsules were developed to achieve target irradiation temperatures between 300°C and 600°C and doses up to 30 dpa. Thermal analyses were performed using finite element methods to establish capsule geometries capable of achieving the desired specimen temperatures while accommodating differences in specimen geometry and material properties. The resulting capsule designs provide the basis for irradiation of the AFC-ARC experimental matrix and subsequent post-irradiation examination to assess the effects of neutron irradiation on advanced cladding materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Twinning and martensitic transformations in nickel-enriched 304 austenitic steel during tensile and indentation deformations

Twinning and martensitic transformation have been investigated in nickel-enriched AISI 304 stainless steel subjected to tensile and indentation deformation. Using electron backscatter diffraction (EBSD), the morphology of alpha- and epsilon-martensite and the effect of grain orientation to load axis on phase and structure transformations were analyzed in detail. It was found that the twinning occurred less frequently under indentation than under tension; also, twinning was not observed in [001] and [101] grains. In tensile tests, the martensite particles preferably formed at the deformation twins, intersections between twins, or at twin-grain boundary intersections. Conversely, martensite formation in the indentation tests was not closely associated with twinning; instead, the majority of martensite was concentrated in the dense colonies near grain boundaries. Martensitic transformation seemed to be obstructed in the [001] grains in both tensile and indentation test cases. Under a tensile stress of 800 MPa, both alpha- and epsilon-martensite were found in the microstructure, but at 1100 MPa only -martensite presented in the specimen. Under indentation, alpha- and epsilon-martensite were observed in the material regardless of stress level.

Gussev, Maxim N↗

Prediction of Aluminum to Steel RSW Joint Failure (CRADA 405)

General Motors, LLC has developed a resistance spot welding process to join aluminum sheet to steel for body-in-white manufacturing. Efforts to develop the process for any one joint configuration (combination of alloy and thicknesses) is intensive. To aid in process understanding and eventual reduction in process development efforts, an initiative was created to develop an finite element model of the various destructive test configurations (lap shear, cross-tension, and coach peel) to help predict the failure mode and load displacement curves under tensile testing. This report describes the finite element modeling approach, the means by which local material properties were determined, as well as model validation and refinement efforts.

36 MATERIALS SCIENCE↗

Mechanical Properties, Microstructural Evolution, and the Effect of Friction on the Plastic Flow of the AISI 321 Austenitic Stainless Steel Tube During Cold Pilgering: An Experimental and Simulation Analysis

The mechanical properties, microstructural evolution, and the effect of friction on the plastic flow of the AISI 321 austenitic stainless steel (ASS) tube were investigated during the cold pilger process. The elastic–plastic behavior of as-received tube was simulated by the Johnson-cook model. The model parameters were obtained by the compression and tensile tests. The mechanical properties of the material were examined by the tensile and microhardness tests. Based on the ring compression test results, three different situations for friction conditions were considered. The stress and strain states at these conditions were examined for the outer and inner surfaces of the tube. Numerical evaluation of plastic shearing due to the cold pilgering of the AISI321 tube was performed. The X-ray diffraction, ferrite scope tests, and optical microscope were also used for the microstructure evaluation and verification of the simulation results, respectively. The Latham-Cockcraft damage was calculated for different conditions by introducing the new subroutine, showing that it was strongly dependent on the friction conditions and the shear strain, ε{sub zr}, respectively. It was shown that the friction coefficient of 0.3 resulted in the minimum damage of the tube and the different friction conditions between the two surfaces of the tube enhanced the damage function. Also, the strain induced ά-martensite increased the work-hardening capacity and affected the ductility of the tube.

36 MATERIALS SCIENCE↗

Effect of Martensite Content on Failure Behavior of Laser Welded Dual-Phase Steel Joints During Deformation

Laser welding was applied to three types of dual-phase (DP) steel sheets (DP590, DP780, and DP980) with different martensite contents. The microstructure of laser welded joints was observed by optical microscope and scanning electron microscope, and the hardness of welded joints was measured by a microhardness tester. The tensile testing machine and the Erichsen test machine were employed to measure the tensile properties and forming properties of welded joints, respectively. The microstructure model showed that the welded joints of three different materials all contained a hardened zone (HZ) that was composed of a fusion zone, a coarse-grained heat-affected zone, and fine-grained heat-affected zone. The microstructure of the HZ contained mainly martensite such that the average martensite content of welded joints was increased by 1.9-9.8%, and the microhardness of the HZ was 1.2-1.9 times that of the base metal (BM). Moreover, the elongation of welded joints decreased with decreasing martensite content in the BM, and the effect was severe for the DP590 welded joint (21.8%) compared to the other two welded joints. During the Erichsen test, deformation failure varied among the welded joints with different martensite contents, and it was determined by the HZ and softened zone. The fracture occurred in the softened zone and ran parallel along the zone for DP980 welded joints, whereas the fracture occurred in the HZ and ran perpendicular to this zone for the other two welded joints. The Erichsen values of the DP590, DP780, and DP980 welded joints were 81.1, 91.7, and 85.0% of the BM, respectively.

36 MATERIALS SCIENCE↗

Creep of Refractory Fibers and Modeling of Metal and Ceramic Matrix Composite Creep Behavior

Our concentration during this research was on the following subprograms. (1) Ultra high vacuum creep tests on 218, ST300 and WHfC tungsten and MoHfC molybdenum alloy wires, temperature range from 1100 K to 1500 K, creep time of 1 to 500 hours. (2) High temperature vacuum tensile tests on 218, ST300 and WHfC tungsten and MoHfC molybdenum alloy wires. (3) Air and vacuum tensile creep tests on polycrystalline and single crystal alumina fibers, such as alumina-mullite Nextel fiber, yttrium aluminum ganet (YAG) and Saphikon, temperature range from 1150 K to 1470 K, creep time of 2 to 200 hours. (4) Microstructural evaluation of crept fibers, TEM study on the crept metal wires, SEM study on the fracture surface of ceramic fibers. (5) Metal Matrix Composite creep models, based on the fiber creep properties and fiber-matrix interface zone formation.

Tewari, S.N.↗

Effect of Heat Treatment on the Microstructure and Mechanical Properties of Monel K500 Alloy Fabricated Via L-PBF and LP-DED

This study examines and compares the effect of different heat treatments (HT) on the microstructure and mechanical properties of Monel K500 fabricated using laser powder bed fusion (L-PBF) and laser powder directed energy deposition (LP-DED) technologies. The as-fabricated Monel K500 specimens exhibited dendritic microstructure and elemental micro-segregation due to high cooling rates induced during the fabrication process. The applicability of HT proposed in the literature for wrought Monel K500 was investigated for L-PBF and LP-DED using four different HT procedures involving hot isostatic pressing (HIP), solution annealing (SA), and aging. The mechanical properties of test specimens were evaluated using uniaxial tensile testing at room temperature. The microstructural evolution of test specimens during HT was analyzed using a scanning electron microscope. For all HT conditions investigated, L-PBF Monel K500 specimens consistently displayed higher strength and lower ductility compared to the LP-DED counterparts. The HT procedure involving HIP at 1160°C for 3hr at 100 MPa, SA at 1100°C for 15 min, and three step aging at 610°C for 16 hr, 540°C for 6 hr, and 480°C for 8 hr resulted in highest strength for both L-PBF and LP-DED fabricated Monel K500.

Additive manufacturing↗

Wide Panel Testing Technique for Evaluating Repair Weld Strengths

This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

Rogers, Patrick R.↗