THERMAL MODELING OF HANFORD CESIUM AND STRONTIUM CANISTERS DURING SIMULATED LOADING

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies within a canister and overpack for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to make pretest numerical predictions for the behavior of the heated canister during the simulated radiolytic decay heat testing, which simulates the dry storage system during loading operations. The simulated radiolytic decay heat test is planned for mid-2024 in a configuration that includes the heater assembly, overpack, and canister, but with the lids removed to allow loading cesium and strontium capsules into the canister. One of the goals of the test is to evaluate the thermal behavior of the canister and overpack assembly in the ambient air of the test facility, which will provide data critical to validating the thermal models and understanding how the HLC will perform as a system once deployed. To best approximate real-world conditions, the CFD model includes the full air volume of the mock-up truck bay the heated canister test will be performed in, enabling detailed investigation of how the heated canister affects airflow around it. Rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2028 timeframe. This study presents the pre-test temperature predictions of the simulated radiolytic decay heat test. A description of the heater assembly, canister, and overpack system is presented. The model was developed with the commercial CFD software STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was preformed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Carpenter-Graffy, Dina E.↗

Performance Evaluation of a Respirator Vortex Cooling Device

The United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina, is dedicated to promoting site-level, risk-based inspection practices to maintain a safe and productive work environment. Protective suits are worn by personnel working in contaminated environments. These suits require that cooling be applied to keep the interior temperature within safe and comfortable limits. A vortex tube, also known as the Ranque-Hilsch vortex tube (RHVT), can provide the necessary cooling. As mechanical devices void of moving components, vortex tubes separate a compressed gas into hot and cold streams—the air emerging from the “hot” end reaching a temperature of 433.2 K and the air emerging from the “cold” end reaching a temperature of 241.5 K (Hilsch, 1946, “Die Expansion Von Gasen Im Zentrifugalfeld Als Kälteprozeß,” Z. Für Naturforsch., 1, pp. 208–214). Routing the cold stream of the vortex tube to the user's protective suit facilitates the required cooling. Vortex tubes currently in use at SRS are preset, through modification solely by and within the SRS respiratory equipment facility (REF), to provide a temperature reduction between 22.2 and 25.0 K. When a new model of vortex tube capable of user adjustment during operation recently became available, prototype testing was conducted for product comparison. Ultimately, it was identified that similar cooling performance between the old and new models is achievable. Production units were acquired to be subjected to complete product analysis at SRS utilizing a statistical test plan. Finally, the statistical test plan, data, thermodynamic calculations, and conclusions were reviewed to determine acceptability for site use.

47 OTHER INSTRUMENTATION↗

Flight Test Hazard Planning Near the Speed of Light

A viewgraph presentation describing flight test safety near the speed of light is shown. The topics include: 1) Concept; 2) Portal Content; 3) Activity to Date; 4) FTS Database Updatd FAA Program; 5) FAA Flight Test Risk Management; 6) CFR 14 Part 21.35 Current and proposed changes; 7) An Online Resource for Flight Test Safety Planning; 8) Data Gathering; 9) NTPS Role; 10) Example Maturation; 11) Many Varied Inputs; 12) Matured Stall Hazards; 13) Loss of Control Mitigations; 14) FAA Access; 15) NASA PBMA Website Link; 16) FAR Reference Search; 17) Record Field Search; 18) Keyword Search; and 19) Results of FAR Reference Search.

Henwood, Bart↗

Preparation and Testing of Sorbents Mixed with an Oxidizing Chemical

This procedure outlines the requirements and steps to perform an evaluation of the relative oxidizing hazard of sorbents amalgamated with potassium nitrite. This testing is based on a modified version of Test Method for Oxidizing Solids (SW-846 Method 1040) outlined in Test Plan for Preparation and Testing of Sorbents Mixed with an Oxidizing Chemical (DWT-TP-002). This work is a continuation of Preparation and Testing of Sorbents Mixed with Oxidizer Found in Transuranic Waste (DWT-TST-001) test plan that was written to provide results to inform the Department of Energy (DOE) Carlsbad Field Office (CBFO) Basis of Knowledge. Documentation of the fastest-burning oxidizer, potassium nitrite, was determined in Oxidizer Scoping Studies (DWT-RPT-001), and the use of Quik Solid as the fastest-burning engineered organic polymer was documented in Sorbent Scoping Studies (DWT-RPT-002).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems

This report summarizes the progress made during the April 01, 2010 – December 30, 2013 period under Cooperative Agreement DE-EE0002752 for the U.S. Department of Energy entitled “High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems.” The overall objective of this program is to advance the technology for well fluids lifting systems to meet the foreseeable pressure, temperature, and longevity needs of the Enhanced Geothermal Systems (EGS) industry for the coming ten years. In this program, lifting system requirements for EGS wells were established via consultation with industry experts and site visits. A number of artificial lift technologies were evaluated with regard to their applicability to EGS applications; it was determined that a system based on electric submersible pump (ESP) technology was best suited to EGS. Technical barriers were identified and a component-level technology development program was undertaken to address each barrier, with the most challenging being the development of a power-dense, small diameter motor that can operate reliably in a 300°C environment for up to three years. Some of the targeted individual component technologies include permanent magnet motor construction, high-temperature insulation, dielectrics, bearings, seals, thrust washers, and pump impellers/diffusers. Advances were also made in thermal management of electric motors. In addition to the overall system design for a full-scale EGS application, a subscale prototype was designed and fabricated. Like the full-scale design, the subscale prototype features a novel “flow-through-the-bore” permanent magnet electric motor that combines the use of high temperature materials with an internal cooling scheme that limits peak internal temperatures to <330°C. While the full-scale high-volume multi-stage pump is designed to lift up to 80 kg/s of process water, the subscale prototype is based on a production design that can pump 20 kg/s and has been modified for high-temperature operation. In parallel with the design and fabrication of the subscale prototype ESP system, a subscale test facility consisting of a high-temperature-high-pressure flow loop was designed, fabricated, and installed at GE Global Research in Niskayuna, NY. A test plan for the prototype system was also established. The original plan of testing the prototype hardware in the flow loop was delayed until a future date.

15 GEOTHERMAL ENERGY↗

NUCON Vapor Abatement Unit Performance on Hanford Tank Farm Chemicals of Potential Concern

This report provided the results and methods used in the NUCON Vapor Abatement Unit performance testing. The purpose of the Pacific Northwest National Laboratory (PNNL) testing was to assess the performance of the NUCON International, Inc., Vapor Abatement Unit (VAU) prototype for the reduction of Hanford Tank Farm vapors associated chemicals of potential concern (COPC). The testing was conducted in compliance with the PNNL Assessment of NUCON Vapor Abatement Unit for Single-Shell Tank (SST) Farm Off-Gas Chemicals of Potential Concern (COPCs) test plan. Performance testing started on May 4, 2018 and continued through June 13, 2018. Eleven (11) COPCs were chosen for testing out of the 61 identified COPCs. The COPCs were chosen either due to the importance of that COPC measured in Hanford high-level waste single-shell tank (SST) vapor emissions, as a surrogate to represent a class of COPC compounds, or both. Results of the performance tests are included.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

UPF and Y-12 Criticality Accident Alarm System (CAAS) Radiation Testing Report

This report documents the experimental conditions and results for the testing of the Mirion Technologies CAAS-3S Criticality Accident Alarm System (CAAS) for the Y-12 National Security Complex (Y-12) and Uranium Processing Facility (UPF). The testing was conducted at the Godiva IV Burst Reactor at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS) during the week of January 11, 2021. The testing was conducted in accordance with 25774-QL-POA-JR00-00002-VDE-27.0, CAAS-3S Radiation Testing of Cabinet Components Test Plan. The tests subjected the CAAS-3S system to intense and short duration mixed neutron and gamma radiation fields and to high integrated radiation doses. The purpose of the test was to environmentally qualify various CAAS-3S components in a radiation environment. Successful completion of the tests was predicated on the collaborative efforts of several organizations. Sandia National Laboratory (SNL) and Lawrence Livermore National Laboratory (LLNL) provided dosimetry to estimate photon and neutron dose. Los Alamos National Laboratory (LANL) manages the NCERC facility, operated the Godiva IV reactor, and provided field support for CAAS-3S placement and communications interface for data acquisition systems supplied by Mirion Technologies. Throughout the test campaign, Y-12 and UPF personnel provided technical support in determining changes to the test schedule, as needed, interpretation of the results, and comparison between the measured dosimetry data and predicted results. Throughout the test campaign, Mirion personnel provided technical support in the operation of the CAAS-3S system itself.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Corrosion Testing of Bubbler Materials for LAW Vitrification (Rev. 0)

This work involved crucible-scale corrosion tests using coupons of selected materials in the baseline glass formulations for the seven LAW Sub-Envelopes. The tests were performed with Inconel 690 and MA 758; per the Test Plan, selected tests were also performed with a proprietary high temperature alloy supplied by SRTC. Coupons of these materials were tested for their corrosion resistance to LAW baseline glasses in two test series: the first series was with a baseline glass only, the second series was with a baseline glass and an added salt layer.

36 MATERIALS SCIENCE↗

FINAL REPORT FOR THE REDUCTION OF CHROME (VI) TO CHROME (III) IN THE SECONDARY WASTE STREAM OF THE EFFLUENT TREATMENT FACILITY

This report documents the laboratory results of RPP-PLAN-35958, Test Plan for the Effluent Treatment Facility to Reduce Chrome (VI) to Chrome (III) in the Secondary Waste Stream With the exception of the electrochemical corrosion scans, all work was carried out at the Center for Laboratory Science (CLS) located at the Columbia Basin College. This document summarizes the work carried out at CLS and includes the electrochemical scans and associated corrosion rates for 304 and 316L stainless steel.

36 MATERIALS SCIENCE↗

ASSESSMENT OF TECHNETIUM LEACHABILITY IN CEMENT STABILIZED BASIN 43 GROUNDWATER BRINE

This report is an initial report on the laboratory effort executed under RPP-PLAN-33338, Test Plan for the Assessment of Technetium Leachability in Cement-Stabilized Basin 43 Groundwater Brine. This report delineates preliminary data obtained under subcontract 21065, release 30, from the RJ Lee Group, Inc., Center for Laboratory Sciences. The report is predicated on CLS RPT-816, Draft Report: Assessment of Technetium Leachability in Cement Stabilized Basin 43 Groundwater Brine. This document will be revised on receipt of the final RJ Lee Group, Inc., Center for Laboratory Sciences report, which will contain data subjected to quality control and quality assurance criteria.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-KW dc distribution system technology research study

The Multi-KW DC Distribution System Technology Research Study is the third phase of the NASA/MSFC study program. The purpose of this contract was to complete the design of the integrated technology test facility, provide test planning, support test operations and evaluate test results. The subjet of this study is a continuation of this contract. The purpose of this continuation is to study and analyze high voltage system safety, to determine optimum voltage levels versus power, to identify power distribution system components which require development for higher voltage systems and finally to determine what modifications must be made to the Power Distribution System Simulator (PDSS) to demonstrate 300 Vdc distribution capability.

Dawson, S. G.↗

Ground shake test of the UH-60A helicopter airframe and comparison with NASTRAN finite element model predictions

Sikorsky Aircraft, together with the other major helicopter airframe manufacturers, is engaged in a study to improve the use of finite element analysis to predict the dynamic behavior of helicopter airframes, under a rotorcraft structural dynamics program called DAMVIBS (Design Analysis Methods for VIBrationS), sponsored by the NASA-Langley. The test plan and test results are presented for a shake test of the UH-60A BLACK HAWK helicopter. A comparison is also presented of test results with results obtained from analysis using a NASTRAN finite element model.

Howland, G. R.↗

Systems special investigation group

An interim report concerning the Long Duration Exposure Facility (LDEF) is presented by a Boeing Systems special investigation group (SIG). The SIG activities were divided into five engineering disciplines: electrical, mechanical, optics, thermal, and batteries/solar cells. The responsibilities of the SIG included the following areas: support de-integration at Kennedy Space Center (KSC); testing of hardware at Boeing; review of principal investigator (PI) test plans and test results; support of test activities at PI labs; and collation of all test results into the SIG database.

Source record↗

Systems integration test laboratory - Application and experiences

The experiences gained from the development of the X-29 aircraft's digital flight control system is discussed. The master test plan, validation testing, verification testing, and flight hardware testing of the system are briefly reviewed, and the test facilities are described. Simulator verification and results are summarized.

Rimer, Melvyn↗

Flight-determined engine exhaust characteristics of an F404 engine in an F-18 airplane

The exhaust characteristics of the F-18 aircraft with an F404 engine are examined with reference to the results of an acoustic flight testing program. The discussion covers an overview of the flight test planning, instrumentation, test procedures, data analysis, engine modeling codes, and results. In addition, the paper presents the exhaust velocity and Mach number data for the climb-to-cruise, Aircraft Noise Prediction Program validation, and ground tests.

Ennix, Kimberly A.↗

On-orbit test of the HST Zero-Gyro safemode controller

The purpose of this paper is to document the on-orbit testing of the Zero-Gyro Sunpoint mode for Hubble Space Telescope, a safemode designed to ensure a power positive state without the use of rate gyros. This paper presents an overview of the test planning and test results.