Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing at Long Duration.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Prototype Aerogel Insulation for Melamine-Foam Substitute: Critical Space Station Express Rack Technology

There is a current lack of environmentally acceptable foams to insulate Long-Duration Human Spaceflight Missions, including the experimental Express Rack for the Space Station. A recent 60-day manned test in a sealed chamber at Johnson Space Center (JSC) was nearly aborted, because of persistently high formaldehyde concentrations in the chamber. Subsequent investigation showed that the source was melamine foam (used extensively for acoustic insulation). The thermal and acoustic potential for melamine-foam substitutes is evaluated for scale-up to a silica-based foam and aerogel, which is environmentally benign for long duration space flight. These features will be discussed in reference to an aerogel prototype to: 1) assemble material strength data for various formulated aerogels, both silica and organic carbon aerogels; 2) assemble the aerogel into panels of mylar/vacuum-encapsulated rigid boards which can be molded in various shapes and rigidities; and 3) describe a process for space applications for formaldehyde-free, long duration thermal and acoustic insulators.

Noever, David A.↗

Long Term Performance Retention Test Using High Power COTS NiCd and NiMH Cells

This slide presentation reviews the tests and results for performance retention of high powered commercial off the shelf (COTS) NiCd, and NiMH cells. Electromechanical actuators for space flight requires short duration high power batteries. The concern is that NiCd battery designs demonstrate an unfavorable power degradation after long periods of inactivity. Cycling can recover some of the decay, but this reduces the readiness that these batteries must have. Two 5-cell SubC stick test batteries ere chosen using NiCd and NiMH were tested and then the differences for charge maintenance were compared.

Hall, Dan↗

Balloon-Borne Observations of the Anisotropy of the Cosmic Microwave'Background on Angular Scales of 0.2 to 40 Degrees'

During this final period, BOOMERANG was deployed to McMurdo Mtn., Antarctica in late 1998 and successfully flew a 10.5 day long duration flight. The experiment returned excellent data, and produced the first resolved images of the early universe. These results, as well as those produced during a test flight over North America in August, 1997, are given in the references below. Analysis of the data from the 1998 flight is continuing. In parallel, we have begun to prepare the payload for a long-duration flight from McMurdo in December 2001. For this flight, the focal plane is being outfitted with polarization sensitive detectors, with the goal of detecting the polarization of the CMB that is predicted to exist at degree angular scales.

Source record↗

Risk of Orthostatic Intolerance During Re-Exposure to Gravity

Post-spaceflight orthostatic intolerance remains a significant concern to NASA. In Space Shuttle missions, astronauts wore anti-gravity suits and liquid cooling garments to protect against orthostatic intolerance during re-entry and landing, but in-flight exercise and the end-of-mission fluid loading failed to protect approximately 30% of Shuttle astronauts when these garments were not worn. The severity of the problem appears to be increased after long-duration space flight. Five of six US astronauts could not complete a 10-minutes upright-posture tilt testing on landing day following 4-5 month stays aboard the Mir space station. The majority of these astronauts had experienced no problems of orthostatic intolerance following their shorter Shuttle flights. More recently, four of six US astronauts could not complete a tilt test on landing day following approximately 6 month stays on the International Space Station. Similar observations were made in the Soviet and Russian space programs, such that some cosmonauts wear the Russian compression garments (Kentavr) up to 4 days after landing. Future exploration missions, such as those to Mars or Near Earth Objects, will be long duration, and astronauts will be landing on planetary bodies with no ground-support teams. The occurrence of severe orthostatic hypotension could threaten the astronauts' health and safety and success of the mission.

Platts, Steven↗

Development and Provision of Functional Foods to Promote Health on Long-Duration Space Missions

During long-duration NASA space missions, such as proposed missions to Mars, astronauts may experience negative physiological effects such as bone loss. Functional foods such as high-lycopene, high-flavonoids and high-omega-3 products and fruits and vegetables may mitigate the negative effects of spaceflight on physiological factors including the bone health of crewmembers. Previous studies showed that current ISS provisions provide high-lycopene and high-omega-3 food items but the variety is limited, which could promote menu fatigue. Bioactive compounds can degrade like other chemical compounds and lose functionality. The native concentrations and stability of bioactive compounds have never been determined in spaceflight foods, and adequate information is not available for commercial products for the storage durations required for space exploration (5 years). The purpose of this task is to develop new spaceflight foods that are high in omega-3 fatty acids, lycopene, or flavonoids, identify commercial products with these bioactive compounds that meet spaceflight requirements, and define the stability of these nutrients in storage to enable purposeful functional food incorporation into the space food system. The impact of storage temperature on the stability of lutein, lycopene, beta-carotene, omega-3 fatty acids, phenolics, anthocyanins and sterols is being studied in 12 ISS menu items stored at three different temperatures (4, 21, 35 degree C) over 2 years. Additionally, nutrient and quality stability are being assessed on a larger food set stored at 21 degree C over 2 years that contains twelve newly developed foods, 10 commercial products repackaged to spaceflight requirements, and another 5 current ISS menu items expected to be good sources of omega-3 fatty acids, lycopene, or flavonoids. All items were shipped overnight to the Linus Pauling Institute at Oregon State University (Corvalis, OR) after processing and 1-year of storage and analyzed for bioactive compound concentrations. Sensory evaluation was conducted on the newly developed functional foods and commercial products with untrained panelists (n is greater than or equal to 25) using a 9-point Hedonic scale to test sensory attributes and overall acceptability after processing and 1-year of storage (21 degree C). Repeat nutritional and sensory analyses will be conducted in the same foods after the 2-year storage period is completed. The stability of bioactive compounds in the selected foods was dependent on storage temperature and food matrix. Omega-3 showed excellent stability in the analyzed products after 1-year of storage, regardless of the storage temperature; phenolic compounds also showed good stability. Lycopene was more stable in oil-based products rather than water-based products because of the protection that lipids offer to lycopene molecules. Also, lycopene was more stable in freeze-dried products than in high moisture foods. The 12 newly developed functional foods showed good overall acceptability in sensory attributes after processing (average score 7.2 out of 9.0) and maintained sensory quality through 1-year (21 degree C); the overall acceptability was on average 7.1 after storage. Similar behavior was observed for the 10 commercial products after 1 year. The developed products are good sources of omega-3 (both plant and marine), vegetables (7 vegetable-based products), and good sources of carotenoids, such as the Curry Pumpkin Soup and the Sweet and Savory Kale. Nine of the new products, such as Mango Salad, Pickled Beets, and Braised Red Cabbage, are rich in phenolic compounds. Stability of most of the studied nutrients seems to be adequate after 1-year of storage in most of the tested foods. However, storage temperature of the food must be considered during long-duration space missions to achieve stability of all nutrients. Likewise, more information is needed regarding nutrient retention after 2-years of storage to identify nutritional gaps that may be expected over the 5-year shelf life required for a Mars mission. New developed products will be filling a gap in the current space food system to minimize menu fatigue, provide specific nutrients to reduce the negative effects of long-duration space missions and maintain crew members' health. Information about bioactive compounds in developed products after 1-year and 2-year of storage will provide the knowledge base for further product development.

Bermudez-Aguirre, D.↗

Increased Treadmill Running and Lower-Body Resistance Training Intensity May Attenuate Aerobic Capacity Loss During Spaceflight

BACKGROUND: In-flight exercise training is the primary countermeasure to mitigate spaceflight-induced decrements in strength and aerobic capacity. Despite high-quality exercise capabilities and prescriptions aboard the International Space Station (ISS), most astronauts experience strength and aerobic capacity loss; however, significant individual variability exists. Recent findings suggest that greater in-flight running (i.e., distance per session) and lower-body resistance exercise intensity (i.e., load relative to body weight) help preserve strength. Whether similar variables contribute to the preservation of aerobic capacity during spaceflight is unknown. METHODS: A NASA database of exercise performance metrics was used to identify long-duration (≥ 90 days) ISS crew who completed pre- and post-flight aerobic capacity testing (VO2peak, cycle ergometry, n = 44). “Responders” (R) were classified as those that maintained or improved VO2peak (n = 13; 1.4 ± 3.3%), and “non-responders” (NR) were those with the most severe decrements (n = 13; -20.0 ± 3.4%) from pre- to post-flight. In-flight exercise records (cycling, treadmill, resistance exercise) were aggregated across flight weeks. Independent t-tests or Mann-Whitney U tests were used to compare training variables (i.e., frequency, time, intensity, volume) between R and NR. RESULTS: Consistent with the variables contributing to strength protection, in-flight running distance (R: 5.0 ± 0.7; NR: 4.2 ± 1.0 km/session, p = 0.020) and lower-body resistance exercise intensity (R: 110.9 ± 27.3; NR: 91.7 ± 16.5% body weight, p = 0.040) were greater in R than NR. Active running time was also greater in R than NR (R: 101.1 ± 20.4; NR: 82.3 ± 23.5 min/wk; p = 0.039). However, no group differences in cycling frequency, intensity, or time, as well as upper body or core resistance exercise intensity, volume, or frequency were observed. CONCLUSIONS: Although physiologically distinct stimuli, the exercise training variables contributing to the preservation of both strength and aerobic capacity during microgravity exposure appear to be consistent. Increased running time and distance, but not cycling, combined with higher-intensity lower-body resistance exercise, may help mitigate losses in both aerobic capacity and strength during long-duration spaceflight.

Alyssa N Varanoske↗

The Mach 10 Component of NASA's Hyper-X Ground Test Program

The Mach 10 Hyper-X ground test program is described, in which experimental flowpath parametric testing is being done in the HYPULSE facility. This facility has been upgraded for this effort by adding a reflected-shock-tunnel operating mode to access test conditions at Mach 10 and below. A large test section and hypersonic nozzle have been installed to provide full-scale engine test capability and the instrumentation systems have been expanded. A model of the Hyper-X engine flowpath has been built for freejet testing in the shock tunnel at both Mach 7 and 10 flight conditions. The model has over 180 instrumentation ports, a pitot rake mountable at the engine inlet or exit, and optical windows for visualization of the isolator, combustor, and nozzle. Testing in HYPULSE has been completed at Mach 7 conditions to provide a link between pulse facility data and the large Hyper-X performance database that is being accumulated in long-duration facilities. Comparisons of Mach 7 data with computational predictions and with data recently acquired for an identical flowpath being tested in the NASA 8-foot High Temperature Tunnel are presented.

Bakos, R. J.↗

Hollow Fiber Membrane Bioreactor Systems for Wastewater Processing: Effects of Environmental Stresses Including Dormancy Cycling and Antibiotic Dosing

Membrane-aerated biofilm reactors (MABRs) have been studied for a number of years as an alternate approach for treating wastewater streams during space exploration. While the technology provides a promising pre-treatment for lowering organic carbon and nitrogen content without the need for harsh stabilization chemicals, several challenges must be addressed before adoption of the technology in future missions. One challenge is the transportation of bioreactors containing intact, active biofilms as a means for rapid start-up on the International Space Station or beyond. Similarly, there could be a need for placing these biological systems into a dormant state for extended periods when the system is not in use, along with the ability for rapid restart. Previous studies indicated that there was little influence of storage condition (4 or 25 C, with or without bulk fluid) on recovery of bioreactors with immature biofilms (48 days old), but that an extensive recovery time was required (20+ days). Bioreactors with fully established biofilms (13 months) were able to recover from a 7-month dormancy within 4 days (approximately 1 residence). Further dormancy and recovery testing is presented here that examines the role of biofilm age on recovery requirements, repeated dormancy cycle capabilities, and effects of long-duration dormancy cycles (8-9 months) on HFMB systems. Another challenge that must be addressed is the possibility of antibiotics entering the wastewater stream. Currently, for most laboratory tests of biological water processors, donors providing urine may not contribute to the study when taking antibiotics because the effects on the system are yet uncharacterized. A simulated urinary tract infection event, where an opportunistic, pathogenic organism, E. coli, was introduced to the HFMBs followed by dosing with an antibiotic, ciprofloxacin, was completed to study the effect of the antibiotic on reactor performance and to also examine the development of antibiotic-resistant communities within the system.

Bioreactor Systems↗

Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

Laughlin, Mitzi S.↗

Demonstrating Next Generation High-Altitude, Long Endurance Aircraft for Earth Science

This paper will address NASA activities to monitor and study Earth processes from long-duration unmanned aircraft systems (UAS). NASA is currently supporting both large and small UAS development and demonstration. In a follow-on to previous work, NASA Armstrong Flight Research Center is hosting test flights of a large AeroVironment solar-powered aircraft, while NASA Ames Research Center is supporting the demonstration of a light-weight solar powered aircraft by Swift Engineering. Both are designed for long duration, multi-day flight. NASA Earth Science and Aeronautics researchers have been involved in the development and use of High Altitude Long Endurance (HALE) UAS since the 1990's. The NASA Environmental Research Aircraft Sensor and Technology Program (ERAST) demonstrated the promise of HALE aircraft for providing observations while also proving the importance of triple-redundant avionics to improve system reliability for large unmanned aircraft. Early efforts to develop an operational HALE capability for earth observations languished for nearly two decades owing to insufficient solar panel efficiency, battery power density, and light-weight, yet strong, materials. During this time NASA researchers focused on using the Global Hawk to demonstrate the utility of providing diurnal measurements over severe storms (i.e. HS3) and to track stratospheric water vapor transport (ATTREX). Recent significant commercial investments are now leading to the realization of a long-held goal of week- to month-long sustained observations and measurements from the stratosphere. In addition to a historical review of NASA use and interest in HALE aircraft, this paper will present current concepts for exploiting current and planned HALE aircraft capabilities including in situ characterization of atmospheric composition and dynamics as well as imagery collection and internet connectivity. NASA researchers anticipate HALE will also provide a useful means to test smallsat instruments and components. Observations from HALE-based instruments might also provide useful gap-filler observations to flagship satellite missions where the repeat time doesn't allow for measurements of quickly changing phenomenon. HALE will likely also provide measurements and communications relay to facilitate other aircraft in multi-aircraft campaigns. We will also report on progress towards a NASA-supported flight tests solar electric vehicles planned for 2019. One is the Swift Engineering UAS designed to carry 7kg (15lbs) for 30 days at 20km altitude. The other is the AeroVironment Hawk 30, also designed for multi-day flight.

high-altitude↗

National Space Biomedical Research Institute

NSBRI partners with NASA to develop countermeasures against the deleterious effects of long duration space flight. NSBRI's science and technology projects are directed toward this goal, which is accomplished by: 1. Designing, testing and validating effective countermeasures to address the biological and environmental impediments to long-term human space flight. 2. Defining the molecular, cellular, organ-level, integrated responses and mechanistic relationships that ultimately determine these impediments, where such activity fosters the development of novel countermeasures. 3. Establishing biomedical support technologies to maximize human performance in space, reduce biomedical hazards to an acceptable level and deliver quality medical care. 4. Transferring and disseminating the biomedical advances in knowledge and technology acquired through living and working in space to the general benefit of humankind; including the treatment of patients suffering from gravity- and radiation-related conditions on Earth. and 5. ensuring open involvement of the scientific community,industry and the public in the Institute's activities and fostering a robust collaboration with NASA, particularly through JSC.

Source record↗

Stirling Convertor Extended Operation Testing and Data Analysis at GRC

This paper focuses on extended operation testing and data analysis of free-piston Stirling convertors at the NASA Glenn Research Center (GRC). Extended operation testing is essential to the development of radioisotope power systems and their potential use for long duration missions. To document the reliability of the convertors, regular monitoring and analysis of the extended operation data is particularly valuable; allowing us to better understand and quantity the long life characteristics of the convertors. Further, investigation and comparison of the extended operation data to baseline performance data provides us an opportunity for understanding system behavior should any off-nominal performance occur. GRC currently has 14 Stirling convertors under 24-hour unattended extended operation testing, including two operating the Advanced Stirling Radioisotope Generator Engineering Unit (ASRG-EU). 10 of the 14 Stirling convertors at GRC are the Advanced Stirling Convertors (ASC) developed by Sunpower, Incorporated. These are highly efficient (up to > 33.5% conversion efficiency), low mass convertors that have evolved through technologically progressive convertor builds. The remaining four convertors at GRC are Technology Demonstration Convertors (TDC) from Infinia Corporation. They have achieved> 27% conversion efficiency and have accumulated over 178,000 of the total 250,622 hours of extended operation currently at GRC. A synopsis of the Stirling convertor extended operation testing and data analysis at NASA GRC is presented in this paper, as well as how this testing has contributed to the Stirling convertor's progression toward flight.

Cornell, Peggy A.↗

Asymmetric Supercapacitor for Long-Duration Power Storage

A document discusses a project in which a series of novel hybrid positive electrode materials was developed and tested in asymmetric capacitors with carbon negative electrodes. The electrochemical performance of the hybrid capacitors was characterized by cyclic voltammetry and a DC charge/discharge test. The hybrid capacitor exhibited ideal capacitor behavior with an extended operating voltage of 1.6 V in aqueous electrolyte, and energy density higher than activated carbon-based supercapacitors. Nanostructured MnO2 is a promising material for electrochemical capacitors (ECS) because of its low cost, environmentally friendly nature, and reasonably high specific capacitance. The charge capacity of the capacitors can be further improved by increasing the specific surface area of the MnO2 electrode material. The power density and space radiation stability of the capacitors can be enhanced by coating the MnO2 nanoparticles with conducting polymers. The conducting polymer coating also helps in radiation-hardening the ECS.

Rangan, Krishnaswamy K.↗

Cardiovascular Aspects of Space Shuttle Flights: At the Heart of Three Decades of American Spaceflight Experience

The advent of the Space Shuttle era elevated cardiovascular deconditioning from a research topic in gravitational physiology to a concern with operational consequences during critical space mission phases. NASA has identified three primary cardiovascular risks associate with short-duration (less than 18 d) spaceflight: orthostatic intolerance; decreased maximal oxygen uptake; and cardiac arrhythmias. Orthostatic hypotension (OH) was observed postflight in Mercury astronauts, studied in Gemini and Apollo astronauts, and tracked as it developed in-flight during Skylab missions. A putative hypotensive episode in the pilot during an early shuttle landing, and well documented postflight hypotension in a quarter of crewmembers, catalyzed NASA's research effort to understand its mechanisms and develop countermeasures. Shuttle investigations documented the onset of OH, tested mechanistic hypotheses, and demonstrated countermeasures both simple and complex. Similarly, decreased aerobic capacity in-flight threatened both extravehicular activity and post-landing emergency egress. In one study, peak oxygen uptake and peak power were significantly decreased following flights. Other studies tested hardware and protocols for aerobic conditioning that undergird both current practice on long-duration International Space Station (ISS) missions and plans for interplanetary expeditions. Finally, several studies suggest that cardiac arrhythmias are of less concern during short-duration spaceflight than during long-duration spaceflight. Duration of the QT interval was unchanged and the frequency of premature atrial and ventricular contractions was actually shown to decrease during extravehicular activity. These investigations on short-duration Shuttle flights have paved the way for research aboard long-duration ISS missions and beyond. Efforts are already underway to study the effects of exploration class missions to asteroids and Mars.

Charles, John B.↗

High-Heat-Flux Cyclic Durability of Thermal and Environmental Barrier Coatings

Advanced ceramic thermal and environmental barrier coatings will play an increasingly important role in future gas turbine engines because of their ability to protect the engine components and further raise engine temperatures. For the supersonic vehicles currently envisioned in the NASA fundamental aeronautics program, advanced gas turbine engines will be used to provide high power density thrust during the extended supersonic flight of the aircraft, while meeting stringent low emission requirements. Advanced ceramic coating systems are critical to the performance, life and durability of the hot-section components of the engine systems. In this work, the laser and burner rig based high-heat-flux testing approaches were developed to investigate the coating cyclic response and failure mechanisms under simulated supersonic long-duration cruise mission. The accelerated coating cracking and delamination mechanism under the engine high-heat-flux, and extended supersonic cruise time conditions will be addressed. A coating life prediction framework may be realized by examining the crack initiation and propagation in conjunction with environmental degradation under high-heat-flux test conditions.

Zhu, Dongming↗

Vestibular-Somatosensory Convergence in Head Movement Control During Locomotion after Long-Duration Space Flight

Exposure to the microgravity conditions of space flight induces adaptive modification in the control of vestibular-mediated reflexive head movement during locomotion after space flight. Space flight causes astronauts to be exposed to somatosensory adaptation in both the vestibular and body load-sensing (BLS) systems. The goal of these studies was to examine the contributions of vestibular and BLS-mediated somatosensory influences on head movement control during locomotion after long-duration space flight. Subjects were asked to walk on a treadmill driven at 1.8 m/s while performing a visual acuity task. Data were collected using the same testing protocol from three independent subject groups; 1) normal subjects before and after exposure to 30 minutes of 40% bodyweight unloaded treadmill walking, 2) bilateral labyrinthine deficient (LD) patients and 3) astronauts who performed the protocol before and after long duration space flight. Motion data from head and trunk segmental motion data were obtained to calculate the angular head pitch (HP) movements during walking trials while subjects performed the visual task, to estimate the contributions of vestibular reflexive mechanisms in HP movements. Results showed that exposure to unloaded locomotion caused a significant increase in HP movements, whereas in the LD patients the HP movements were significantly decreased. Astronaut subjects results showed a heterogeneous response of both increases and decreases in the amplitude of HP movement. We infer that BLS-mediated somatosensory input centrally modulates vestibular input and can adaptively modify head-movement control during locomotion. Thus, space flight may cause a central adaptation mediated by the converging vestibular and body load-sensing somatosensory systems.

Mulavara, Ajitkumar↗

VEG-04 PICK-AND-EAT CROP PRODUCTION AND HUMAN RESEARCH ON THE INTERNATIONAL SPACE STATION

Growing fresh, nutritious, palatable produce for crew consumption during spaceflight may provide health-promoting, bioavailable nutrients and enhance the astronaut dietary experience as we move toward longer-duration missions. Tending plants may also serve as a countermeasure for crew psychological stresses associated with spaceflight. However, requirements to support consistent growth of a variety of nutritious crops under spaceflight environmental conditions remain unclear. This study explores the potential to grow crops for consumption on the International Space Station (ISS) using the Veggie vegetable-production system. VEG-04A and B were two flight tests conducted in 2019 with the leafy green crop Mizuna mustard. Mizuna was grown in two Veggie chambers simultaneously, with the chambers set to different red-to-blue light formulations; one Veggie was programmed as “red-rich” and the second as “blue-rich.” Light quality is known to impact plant growth, nutrition, microbiology, and organoleptic characteristics on Earth, and the Veggie flight tests examined how these impacts might differ in microgravity. VEG-04A was a 35-day growth test with a single harvest. VEG-04B, a 58-day test with harvests at four, six, and eight weeks from the same plants, assessed sustained productivity. Challenges with the watering program occurred early during VEG-04A, and several plants failed to survive in both the flight and ground control operations. Thus, prior to VEG-04B, an extra test was conducted to tailor water timing and volumes. This test allowed a fine tuning of methods for VEG-04B, and generally plant survival was better in that experiment. At each harvest, the astronauts froze half of the edible plant tissue to return to Earth and weighed the remaining half using the ISS Mass Measurement Device (MMD). Weighed samples were then cleaned with produce-sanitizing wipes, and consenting crew members participated in organoleptic evaluation of the fresh produce. Organoleptic evaluations were conducted on the Mizuna crops grown in both light treatments, and data from these tests are compared to ground data collected at JSC. The remaining sanitized produce was available for crew consumption as desired. Frozen flight samples were returned for microbial and chemical analyses to assess food safety and nutritional quality. Microbial assessments included culturing and identifying aerobic bacteria, yeasts, and molds, and screening for specific human pathogens. Chemical nutrient analyses included assessing elements, antioxidants, and phenolics in plant tissues. Crew members involved in plant operations completed behavioral health surveys pre-flight, in-flight associated with plant growth and harvest activities, and post-flight. Surveys captured the amount of time spent on different plant-related operations, enjoyment of the different activities, engagement with Veggie, experience interacting with Veggie, and sensory stimulation associated with growing plants in Veggie. Within each study, plant growth did not differ across light treatment or location (flight versus ground). In general, more biomass was produced in most treatments during the longer study, but growth of this crop declined over time with the repeated harvests. On average, bacterial and fungal counts were significantly lower on ground control samples than flight samples, and microbial counts increased with repeated harvests. Light treatment did not influence any elements in tissues tested; however, the growth duration did impact levels of several elements. Organoleptic scores were generally higher in flight, and ground tasters considered samples more bitter. Amount of interaction and responses to Veggie varied widely by individual. Enjoyable tasks had higher impact than non-enjoyable tasks and interacting with Veggie was generally viewed as positive. These tests on ISS are helping to mitigate the risk of an inadequate food supply for long-duration missions by adding fresh vegetables and key nutrients to the crew diet, and indicating which plant care activities are providing behavioral health benefits for the crew. This research was co-funded by the Human Research Program and Space Biology (MTL#1075) in the ILSRA 2015 NRA call. Videos due Jan. 25th.

Veggie↗

Simulated Weightlessness Alters Cardiomyocyte Structure and Transcriptional Regulation of Mediators Related to Immunity and Cardiovascular Disease

Spaceflight and the ensuing fluid shifts, together with an overall reduction in physical activity, lead to acute and latent effects on the cardiovascular system. This current study makes use of the rodent hindlimb unloading (HU) model to determine how factors such as sex, age, and duration of exposure impact cardiac responses to weightlessness. We hypothesize that extended exposure to simulated weightlessness and the ensuing recovery alters cardiac structure and expression of select genes, including those involved in redox signaling which together, negatively impact long-term cardiac tissue health. To begin to test this hypothesis, male and female rats underwent HU at various durations up to 90 days, with a subset reambulated after 90 days of HU. Physiological stress or contractility changes lead to alterations in ventricular cardiomyocyte size and ventricular wall thickness to adapt to greater functional demand and mitigate mechanical stress to ventricular tissue; under certain conditions, these changes also may mark progression to cardiac failure. Hence, left ventricular cardiomyocyte size (cardiomyocyte cross sectional area, CSA) was quantified to determine if HU leads to structural adaptation responses in cardiac tissue and if age and sex had any impact on this outcome. Cardiomyocyte CSA of older males (9 months) were altered by HU in a time-dependent manner, where HU led to decreases in CSA at 14 days and increases at 90 days. In contrast, younger males (3 months) did not show any changes at day 14 of HU. CSA of females (3 months) was increased in response to short-term HU (14 days) suggesting sex-dependence of structural changes. In older HU males, cardiomyocyte CSA was comparable to controls after 90 days of re-ambulation. Levels of the DNA oxidative damage marker, 8-hydroxydeoxyguanosine (8-OHdG) were greater in left ventricular tissue of females that underwent HU compared to sex-matched controls, while there were no such differences in older or younger males. To gain insight into the signals that drive cardiac adaptations to HU, global transcriptomic analysis (RNAseq) was performed on left ventricular tissue of older males that underwent 14 days of HU. Short-term simulated weightlessness led to differential expression of genes involved in immune and pro-inflammatory signaling. A subset of these genes play a role in autoimmune and cardiovascular disease and are targets of current drugs used to treat bradycardia, hypertension, atherosclerosis and rheumatoid arthritis, amongst others. Oxidative damage/redox signaling pathways were not enriched at the timepoint tested in older males. Since young females displayed greater oxidative damage to DNA, activation of oxidative stress responses at earlier or later time points cannot be ruled out. In summary, simulated weightlessness in adult rats caused changes in cardiomyocyte structure in a sex and age-dependent manner, and the transcriptional regulation of key mediators of immunity and cardiovascular disease, meriting further study to define cardiac risks for interplanetary travel of human crew. Our findings also confirm the value of the rat HU model for cardiac health and countermeasure research.

Tahimic, Candice↗