Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Transient Heater Analysis for Orion Thermal Vacuum Testing

The Space Environments Complex (SEC) at NASA's Plum Brook Station is currently being prepared to perform thermal vacuum testing of the Orion spacecraft. This thermal vacuum, or T-VAC test will be run for a period of 60 days, which will be the longest such test ever conducted at SEC. The Orion Crew Module (CM) and Service Module (SM) will undergo T-VAC testing in SEC's Space Simulation Vacuum Chamber to ensure the functionality of these systems in a high vacuum environment at extremely cold temperatures. The T-VAC test setup in SEC was modeled and simulated in Thermal Desktop. The initial results from thermal analysis showed areas on the chamber floor to reach very low temperatures, which were below the minimum operating range of certain hardware located on or near the chamber floor. These hardware including elastomeric seals on the GN2 piping, bearing pads and O-rings are essential to both test and the operation of the SEC facility, and must be kept well above -20°F throughout the duration of the T-VAC test. Thus, further analysis was conducted to include the placement of patch heaters on the chamber floor in an effort to increase the temperature near colder areas on the floor. The results and findings from this analysis showed that using these heaters will result in a favorable temperature distribution on the chamber floor. This paper will discuss the methods used in the analysis, and the results obtained to determine the optimal configuration of these heaters on the chamber floor.

Wilhite, Jarred↗

Transient Heater Analysis for Orion Thermal Vacuum Testing

The Space Environments Complex (SEC) at NASA’s Plum Brook Station is currently being prepared to perform thermal vacuum testing of the Orion spacecraft. This thermal vacuum, or T-VAC test will be run for a period of 60 days, which will be the longest such test ever conducted at SEC. The Orion Crew Module (CM) and Service Module (SM) will undergo T-VAC testing in SEC’s Space Simulation Vacuum Chamber to ensure the functionality of these systems in a high vacuum environment at extremely cold temperatures. The T-VAC test setup in SEC was modeled and simulated in Thermal Desktop. The initial results from thermal analysis showed areas on the chamber floor to reach very low temperatures, which were below the minimum operating range of certain hardware located on or near the chamber floor. These hardware including elastomeric seals on the GN2 piping, bearing pads and O-rings are essential to both test and the operation of the SEC facility, and must be kept well above -20°F throughout the duration of the T-VAC test. Thus, further analysis was conducted to include the placement of patch heaters on the chamber floor in an effort to increase the temperature near colder areas on the floor. The results and findings from this analysis showed that using these heaters will result in a favorable temperature distribution on the chamber floor. This paper will discuss the methods used in the analysis, and the results obtained to determine the optimal configuration of these heaters on the chamber floor.

Wilhite, Jarred↗

Thermal-Acoustic Analysis of a Metallic Integrated Thermal Protection System Structure

A study is undertaken to investigate the response of a representative integrated thermal protection system structure under combined thermal, aerodynamic pressure, and acoustic loadings. A two-step procedure is offered and consists of a heat transfer analysis followed by a nonlinear dynamic analysis under a combined loading environment. Both analyses are carried out in physical degrees-of-freedom using implicit and explicit solution techniques available in the Abaqus commercial finite-element code. The initial study is conducted on a reduced-size structure to keep the computational effort contained while validating the procedure and exploring the effects of individual loadings. An analysis of a full size integrated thermal protection system structure, which is of ultimate interest, is subsequently presented. The procedure is demonstrated to be a viable approach for analysis of spacecraft and hypersonic vehicle structures under a typical mission cycle with combined loadings characterized by largely different time-scales.

Behnke, Marlana N.↗

Improved finite element methodology for integrated thermal structural analysis

An integrated thermal-structural finite element approach for efficient coupling of thermal and structural analysis is presented. New thermal finite elements which yield exact nodal and element temperatures for one dimensional linear steady state heat transfer problems are developed. A nodeless variable formulation is used to establish improved thermal finite elements for one dimensional nonlinear transient and two dimensional linear transient heat transfer problems. The thermal finite elements provide detailed temperature distributions without using additional element nodes and permit a common discretization with lower order congruent structural finite elements. The accuracy of the integrated approach is evaluated by comparisons with analytical solutions and conventional finite element thermal structural analyses for a number of academic and more realistic problems. Results indicate that the approach provides a significant improvement in the accuracy and efficiency of thermal stress analysis for structures with complex temperature distributions.

Dechaumphai, P.↗

Thermal design analysis of shuttle cargo bay payloads

The thermal design analysis methodology, the thermal control philosophy, and preliminary thermal analysis results associated with specific shuttle payloads are presented. The payloads considered are the Get-Away Special canisters being developed by NASA Goddard, which may be flown on a variety of missions, and the six experiments which are mounted on the GSFC pallet to be flown on Operational Flight test No. 4 (OFT-4). The thermal control alternatives currently available to OFT-4 instruments are the use of pallet cold plates (if available) or operational constraints which allow passive thermal control without the use of excessive heater power. The characteristics of a completely passive thermal control design are evidenced by the results of the Get-Away Special canister analysis.

Bartoszek, J. T.↗

Transient Thermal Testing and Analysis of a Thermally Insulating Structural Sandwich Panel

A core configuration was devised for a thermally insulating structural sandwich panel. Two titanium prototype panels were constructed to illustrate the proposed sandwich panel geometry. The core of one of the titanium panels was filled with Saffil(trademark) alumina fibrous insulation and the panel was tested in a series of transient thermal tests. Finite element analysis was used to predict the thermal response of the panel using one- and two-dimensional models. Excellent agreement was obtained between predicted and measured temperature histories.

Blosser, Max L.↗

Integrated Steady-State System Package for Nuclear Thermal Propulsion Analysis Using Multi-Dimensional Thermal Hydraulics and Dimensionless Turbopump Treatment

Nuclear thermal propulsion is an evolving technology that can be utilized for long-distance space travel. This technology yields the advantage of a high thrust and specific impulse, but requires an examination of the potential design adjustments necessary to enhance its feasibility. The development of nuclear thermal propulsion requires a comprehensive understanding of the system-level behavior during transient and steady-state operation. This paper extends our previous research by including the proper handling of turbomachinery with multi-channel thermal hydraulic simulations only for steady-state solutions. The system-level approach presented here enables the treatment of the turbopump components through non-dimensional analysis that eliminates the assumption of constant efficiencies. All the other components within the system (e.g., reflector and core) can be discretized to multiple channels and layers, in which the full thermal hydraulic solution is established. The approach chosen here enables the realistic modeling of the propellant flow within the expander cycle by capturing the pressure losses, mass flow rate splits, and enthalpy gain for various operational conditions. The verification of the package is completed through point comparisons of previous investigations into similar system designs. Furthermore, sensitivity studies are used to benchmark the capabilities of the package and investigate solution variations due to the perturbation of operational conditions and regimes. The sensitivity studies performed here are important to capture variation in flow characteristics (e.g., temperature, pressure, mass flow rates) for different design objectives such as the thrust and specific impulse. This work demonstrates that system-level simulations lacking multi-channel capability and proper turbomachinery treatment may yield higher uncertainties in understanding the engine’s response and characteristics to changing various requirements. This is extremely important when screening the design space of such propulsion systems and when transient simulations are required.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bimodal Nuclear Thermal Rocket Analysis Developments

Nuclear thermal propulsion has long been considered an enabling technology for human missions to Mars and beyond. One concept of operations for these missions utilizes the nuclear reactor to generate electrical power during coast phases, known as bimodal operation. This presentation focuses on the systems modeling and analysis efforts for a NERVA derived concept. The NERVA bimodal operation derives the thermal energy from the core tie tube elements. Recent analysis has shown potential temperature distributions in the tie tube elements that may limit the thermodynamic efficiency of the closed Brayton cycle used to generate electricity with the current design. The results of this analysis are discussed as well as the potential implications to a bimodal NERVA type reactor.

Nuclear rocket engines↗

Thermal / structural analysis of the HB 650 thermal shield

Fermilab’s PIP-II project’s superconducting linear accelerator will drive the next generation of particle accelerators through a revolution in beam intensity. Key to beam intensification are the high efficiencies of niobium-tin superconducting radiofrequency (SRF) cavities operating at cryogenic temperatures near 5 Kelvin. A multifaceted approach is employed to achieve and maintain the extreme temperature. Vacuum provides the first barrier to thermal convection. Physical thermal intercept zones further isolate the exterior shell vacuum vessel at 300 Kelvin from the supercooled beamline. The first thermal intercept lies just inside the exterior vacuum vessel forming the 40 Kelvin zone. This 40K thermal shield is the focus of this investigation. In preparation for operation, the thermal shield is cooled from 300K to 40K in a slow process over 2-1/2 days. The factors limiting the cooling rate are a high thermal gradient which produces thermal strain and high mechanical stress. D ecreasing the time required to reach operational temperatures is the desired research goal. Physical testing data and finite element method (FEM) computer models from the Single Spoke Resonator – 1 (SSR1) and Linac Coherent Light Source (LCLS-II) cryomodules will be evaluated to determine needed design changes. The thermal shield design for the High Beta 650 MHz (HB650) will be modified and analyzed using FEM computer models to determine maximum cooling rate with a target of 50 thermal cycles of life. Maximum allowable stress will be determined through low cycle fatigue calculations.

43 PARTICLE ACCELERATORS↗

Micromechanics thermal stress analysis of composites for space structure applications

This paper presents results from a finite element micromechanics analysis of thermally induced stresses in composites at cryogenic temperatures typical of spacecraft operating environments. The influence of microstructural geometry, constituent and interphase properties, and laminate orientation were investigated. Stress field results indicated that significant matrix stresses occur in composites exposed to typical spacecraft thermal excursions; these stresses varied with laminate orientation and circumferential position around the fiber. The major difference in the predicted response of unidirectional and multidirectional laminates was the presence of tensile radial stresses, at the fiber/matrix interface, in multidirectional laminates with off-axis ply angles greater than 15 deg. The predicted damage initiation temperatures and modes were in good agreement with experimental data for both low (207 GPa) and high (517 GPa) modulus carbon fiber/epoxy composites.

Bowles, David E.↗

TPSAS-NF1676L-16659-DND

Heat transfer is best understood through theory and application of principles in thermal analysis. Modern thermal analysis leverages the power of computers and numerical methods to simulate heat transfer in networks representing a physical system. This lesson is an introduction to numerical methods in heat transfer.

Steven L Rickman↗

Thermal-striping analysis methodology for sodium-cooled reactor design

Computational fluid dynamics simulations have been performed to study the applicability of engineering CFD methods for thermals striping analysis. Thermal striping is the fluctuating temperature profile in a solid caused by fluctuating fluid temperature, and the resulting fluctuating thermal stresses cause high cycle fatigue and eventual material failure. Here this study presents the methodology for thermal striping analysis that including a transient conjugate heat transfer RANS model and benchmark the results against a sodium triple jet experiment. The multiphysics calculations are implemented to analyze the thermal stresses in the solid domain caused by the coupled heat transfer between the fluid and solid domains. Validation data from a liquid sodium triple jet experiment include time-averaged temperature measurements and power spectra of the temperature signal. The numerical results agree well with these experimental measures, demonstrating key features such as the dominant frequency of temperature fluctuations. The applicability of a low-cost wall treatment method is demonstrated, enabling key computational savings. Finally, the performance of two finite element stress analysis software packages is compared, and the validity of the lower-cost method is confirmed. These results demonstrate the applicability of engineering methods for computational thermal striping calculations, enabling thermal striping estimations in large fluid systems such as the core of a Sodium-cooled nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗