Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

From Femtoseconds to Gigaseconds: The SolDeg Platform for the Performance Degradation Analysis of Silicon Heterojunction Solar Cells

Heterojunction Si solar cells exhibit notable performance degradation. Here, we modeled this degradation by electronic defects getting generated by thermal activation across energy barriers over time. To analyze the physics of this degradation, we developed the SolDeg platform to simulate the dynamics of electronic defect generation. First, femtosecond molecular dynamics simulations were performed to create a-Si/c-Si stacks, using the machine learning-based Gaussian approximation potential. Second, we created shocked clusters by a cluster blaster method. Third, the shocked clusters were analyzed to identify which of them supported electronic defects. Fourth, the distribution of energy barriers that control the generation of these electronic defects was determined. Fifth, an accelerated Monte Carlo method was developed to simulate the thermally activated time-dependent defect generation across the barriers. Our main conclusions are as follows. (1) The degradation of a-Si/c-Si heterojunction solar cells via defect generation is controlled by a broad distribution of energy barriers. (2) We developed the SolDeg platform to track the microscopic dynamics of defect generation across this wide barrier distribution and determined the time-dependent defect density N(t) from femtoseconds to gigaseconds, over 24 orders of magnitude in time. (3) We have shown that a stretched exponential analytical form can successfully describe the defect generation N(t) over at least 10 orders of magnitude in time. (4) We found that in relative terms, Voc degrades at a rate of 0.2%/year over the first year, slowing with advancing time. (5) We developed the time correspondence curve to calibrate and validate the accelerated testing of solar cells. We found a compellingly simple scaling relationship between accelerated and normal times t normal ∝ t accel T(accel)/T(normal) . (6) We also carried out experimental studies of defect generation in a-Si:H/c-Si stacks. We found a relatively high degradation rate at early times that slowed considerably at longer time scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hot Spot Evolution Measured by High-Resolution X-Ray Spectroscopy at the National Ignition Facility

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He β spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. Here these advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MSTAR: an absolute metrology system with submicrometer accuracy

Laser metrology systems are a key component of stellar interferometers, used to monitor path lengths and dimensions internal to the instrument. Most interferometers use ‘relative’ metrology, in which the integer number of wavelengths along the path is unknown, and the measurement of length is ambiguous. Changes in the path length can be measured relative to an initial calibration point, but interruption of the metrology beam at any time requires a re-calibration of the system. The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. We describe the design of the system, show results for target distances up to 1 meter, and demonstrate how the system can be scaled to kilometer-scale distances. In recent experiments, we have used white light interferometry to augment the ‘truth’ measurements and validate the zero-point of the system. MSTAR is a general-purpose tool for conveniently measuring length with much greater accuracy than was previously possible, and has a wide range of possible applications

Fetterman, Harrold R.↗

The connection between forest degradation and urban energy demand in sub-Saharan Africa: a characterization based on high-resolution remote sensing data

Charcoal is a key energy source for urban households in sub-Saharan Africa and charcoal production is the main cause of forest degradation across the region. We used multitemporal high-resolution remote sensing optical imagery to quantify the extent and intensity of forest degradation associated with charcoal production and its impact on forest carbon stocks for the main supplying area of an African capital. This analysis documents the advance of forest degradation and quantifies its aboveground biomass removals over a seven-year period, registering that, between 2013 and 2016, the average annual area under charcoal production was 103 sq.km and the annual aboveground biomass removals reached 1081 000 (SD = 2461) Mg. Kiln densities in the study area rose to 2 kilns-ha, with an average of 90.7 Mg ha^(−1) of extracted aboveground biomass. Charcoal production was responsible for the degradation of 55.5% of the mopane woodlands in the study area between 2013 and 2019. We estimated post-disturbance recovery times using an ecosystem model calibrated for the study area. The simulations showed that recovery times could require up to 150 years for current aboveground biomass extraction rates. The results of the remote sensing analysis and the simulations of the ecosystem model corroborate the unsustainability of the present patterns of charcoal production. The detailed characterization of the spatial and temporal patterns of charcoal production was combined with household survey information to quantify the impact of the urban energy demand of the Maputo urban area on forest carbon stocks. The analysis shows that Maputo charcoal demand was responsible for the annual degradation of up to 175.3 sq.km and that the contribution of the study area to this demand fluctuated between 75% and 33% over the study period. The extent, advance pace and distance from urban centers documented in this study support the idea that forest degradation from charcoal production cannot merely be considered a peri-urban process. The intensity of the aboveground biomass (AGB) removals and its contribution to forest carbon stocks changes is significant at the national and regional levels.

F Sedano↗

Frequency Domain Beamforming for a Deep Space Network Downlink Array

This paper describes a frequency domain beamformer to array up to 8 antennas of NASA's Deep Space Network currently in development. The objective of this array is to replace and enhance the capability of the DSN 70m antennas with multiple 34m antennas for telemetry, navigation and radio science use. The array will coherently combine the entire 500 MHz of usable bandwidth available to DSN receivers. A frequency domain beamforming architecture was chosen over a time domain based architecture to handle the large signal bandwidth and efficiently perform delay and phase calibration. The antennas of the DSN are spaced far enough apart that random atmospheric and phase variations between antennas need to be calibrated out on an ongoing basis in real-time. The calibration is done using measurements obtained from a correlator. This DSN Downlink Array expands upon a proof of concept breadboard array built previously to develop the technology and will become an operational asset of the Deep Space Network. Design parameters for frequency channelization, array calibration and delay corrections will be presented as well a method to efficiently calibrate the array for both wide and narrow bandwidth telemetry.

Filterbank↗

A 40 Year Time Series of SBUV Observations: the Version 8.6 Processing

Under a NASA program to produce long term data records from instruments on multiple satellites (MEaSUREs), data from a series of eight SBUV and SBUV 12 instruments have been reprocessed to create a 40 year long ozone time series. Data from the Nimbus 4 BUV, Nimbus 7 SBUV, and SBUV/2 instruments on NOAA 9, 11, 14, 16, 17, and 18 were used covering the period 1970 to 1972 and 1979 to the present. In past analyses an ozone time series was created from these instruments by adjusting ozone itself, instrument by instrument, for consistency during overlap periods. In the version 8.6 processing adjustments were made to the radiance calibration of each instrument to maintain a consistent calibration over the entire time series. Data for all eight instruments were then reprocessed using the adjusted radiances. Reprocessing is necessary to produce an accurate latitude dependence. Other improvements incorporated in version 8.6 included the use of the ozone cross sections of Brion, Daumont, and Malicet, and the use of a cloud height climatology derived from Aura OMI measurements. The new cross sections have a more accurate temperature dependence than the cross sections previously used. The OMI-based cloud heights account for the penetration of UV into the upper layers of clouds. The consistency of the version 8.6 time series was evaluated by intra-instrument comparisons during overlap periods, comparisons with ground-based instruments, and comparisons with measurements made by instruments on other satellites such as SAGE II and UARS MLS. These comparisons show that for the instruments on NOAA 16, 17 and 18, the instrument calibrations were remarkably stable and consistent from instrument to instrument. The data record from the Nimbus 7 SBUV was also very stable, and SAGE and ground-based comparisons show that the' calibration was consistent with measurements made years laterby the NOAA 16 instrument. The calibrations of the SBUV/2 instruments on NOAA 9, 11, and 14 were more of a problem. The rapidly drifting orbits of these satellites resulted in relative time and altitude dependent differences that are significant. Despite these problems, total column ozone appears to be consistent to better than 1% over the entire time series, while the ozone vertical distribution is consistent to approximately 5%.

McPeters, Richard↗

Toward a Self-calibrating, Empirical, Light-weight Model for Tellurics in High-resolution Spectra

To discover Earth analogs around other stars, next generation spectrographs must measure radial velocity with 10 cm s{sup −1} precision. Since even microtellurics can induce RV errors of up to 50 cm s{sup −1}, achieving 10 cm s{sup −1} precision requires precise modeling of telluric absorption features. The standard approaches to telluric modeling are (a) observing a standard star and (b) using a radiative transfer code. Observing standard stars, however, takes valuable observing time away from science targets. Radiative transfer codes, meanwhile, may omit microtelluric features, which are an important contributor to the RV error budget at 10 cm s{sup −1}. To address these issues, we present a telluric model of the self-calibrating, empirical, light-weight linear regression telluric (SELENITE) model for high-resolution spectra. The model exploits two simple observations: (a) water tellurics grow proportionally to precipitable water vapor and therefore proportionally to each other and (b) non-water tellurics grow proportionally to airmass. Water tellurics can be identified by looking for pixels whose growth correlates with a known calibration water telluric and modeled by regression against it, and likewise non-water tellurics with airmass. The model does not require line data, water vapor measurements, or additional observations (beyond one-time calibration observations), achieves fits with a χ{sub red}{sup 2} of 1.17 on B stars and 2.95 on K dwarfs, and leaves residuals of 1% (B stars) and 1.1% (K dwarfs) of continuum. Fitting takes seconds on laptop PCs; SELENITE is light-weight enough to guide observing runs.

79 ASTRONOMY AND ASTROPHYSICS↗

Metafitting: Weight optimization for least-squares fitting of PTTI data

For precise time intercomparisons between a master frequency standard and a slave time scale, we have found it useful to quantitatively compare different fitting strategies by examining the standard uncertainty in time or average frequency. It is particularly useful when designing procedures which use intermittent intercomparisons, with some parameterized fit used to interpolate or extrapolate from the calibrating intercomparisons. We use the term 'metafitting' for the choices that are made before a fitting procedure is operationally adopted. We present methods for calculating the standard uncertainty for general, weighted least-squares fits and a method for optimizing these weights for a general noise model suitable for many PTTI applications. We present the results of the metafitting of procedures for the use of a regular schedule of (hypothetical) high-accuracy frequency calibration of a maser time scale. We have identified a cumulative series of improvements that give a significant reduction of the expected standard uncertainty, compared to the simplest procedure of resetting the maser synthesizer after each calibration. The metafitting improvements presented include the optimum choice of weights for the calibration runs, optimized over a period of a week or 10 days.

Douglas, Rob J.↗

Goal-oriented a-posteriori estimation of model error as an aid to parameter estimation

In this work, a Bayesian model calibration framework is presented that utilizes goal-oriented a-posterior error estimates in quantities of interest (QoIs) for classes of high-fidelity models characterized by PDEs. It is shown that for a large class of computational models, it is possible to develop a computationally inexpensive procedure for calibrating parameters of high-fidelity models of physical events when the parameters of low-fidelity (surrogate) models are known with acceptable accuracy. The main ingredients in the proposed model calibration scheme are goal-oriented a-posteriori estimates of error in QoIs computed using a so-called lower fidelity model compared to those of an uncalibrated higher fidelity model. The estimates of error in QoIs are used to define likelihood functions in Bayesian inversion analysis. A standard Bayesian approach is employed to compute the posterior distribution of model parameters of high-fidelity models. As applications, parameters in a quasi-linear second-order elliptic boundary-value problem (BVP) are calibrated using a second-order linear elliptic BVP. In a second application, parameters of a tumor growth model involving nonlinear time-dependent PDEs are calibrated using a lower fidelity linear tumor growth model with known parameter values.

A-posterior estimates↗

The Magnetospheric Multiscale Magnetometers

The success of the Magnetospheric Multiscale mission depends on the accurate measurement of the magnetic field on all four spacecraft. To ensure this success, two independently designed and built fluxgate magnetometers were developed, avoiding single-point failures. The magnetometers were dubbed the digital fluxgate (DFG), which uses an ASIC implementation and was supplied by the Space Research Institute of the Austrian Academy of Sciences and the analogue magnetometer (AFG) with a more traditional circuit board design supplied by the University of California, Los Angeles. A stringent magnetic cleanliness program was executed under the supervision of the Johns Hopkins University,s Applied Physics Laboratory. To achieve mission objectives, the calibration determined on the ground will be refined in space to ensure all eight magnetometers are precisely inter-calibrated. Near real-time data plays a key role in the transmission of high-resolution observations stored onboard so rapid processing of the low-resolution data is required. This article describes these instruments, the magnetic cleanliness program, and the instrument pre-launch calibrations, the planned in-flight calibration program, and the information flow that provides the data on the rapid time scale needed for mission success.

Magnetosphere↗

LONG-TERM CALIBRATION STABILITY OF A RADIO ASTRONOMICAL PHASED ARRAY FEED

There are many challenges associated with the implementation of a phased array feed for radio astronomy applications. Among these is the need to have an adequate set of calibration measurements so that reliable beamformers can be computed. Changes in the operating environment and temporal gain drift in the electronics contribute to calibration drift, which affects the beamformer performance. We will show that calibration measurements are relatively stable over a 5 day period and may remain so for up to 70 days or longer. We have incorporated the use of a calibration update system that has the potential to refresh a set of old calibrators, specifically correcting for electronic gain drift. However, the long-term variations that are present with fresh, current calibrators are greater than the degradation due to using an old calibration set, suggesting that, at this time, there is not a need for sophisticated calibration update systems or algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental calibration procedures for rotating Lorentz-force flowmeters

Rotating Lorentz-force flowmeters are a novel and useful technology with a range ofapplications in a variety of different industries. However, calibrating these flowmeters canbe challenging, time-consuming, and expensive. In this paper, simple calibration proceduresfor rotating Lorentz-force flowmeters are presented. These procedures eliminate the need forexpensive equipment, numerical modeling, redundant flowmeters, and system down-time.The calibration processes are explained in a step-by-step manner and compared to experimental results.

Lorentz force↗

A Quick Summary of IMERG Versions and Features

This talk will summarize the shifts in IMERG (Integrated Multi-satellitE Retrievals for GPM (Global Precipitation Measurement)) from Version 03 to 04 in early Spring 2016, and to Version 05 in late Summer 2017. For example, Version 04 replaced approximate pre-launch calibrations with GPM Core Observatory-based calibrations, while Version 05 introduced improved estimates for the primary GPM instrument products (DPR, GMI, and Combined Instrument). In Version 04 the IR estimates were routinely calibrated to the passive microwave estimates. As analysis showed that the Combined Instrument estimates (the IMERG calibration standard) tend to be biased high over land and low over ocean at higher latitudes, in Version 04 we climatologically calibrated IMERG to the Global Precipitation Climatology Project (GPCP) monthly Satellite-Gauge product, except in low- and mid-latitude ocean regions. This calibration leaves the relative time series intact, and only adjusts the mean of the entire series. In Version 05 the primary GPM instrument products have reduced biases, but calibration to GPCP continues to be necessary to achieve the most realistic estimates. Finally, retrospective processing back into the TRMM (Tropical Rainfall Measuring Mission) era is expected in early 2018, after which the legacy TMPA (TRMM Multi-satellite Precipitation Analysis) dataset will be retired.

Huffman, George J.↗

Innovative Imaging Spectrometer Calibration Techniques

A laboratory calibration of the Airborne Visible Infrared Imaging Spectrometer (AVIRIS) allowed experimentation with several innovative calibration techniques that would improve calibration accuracy, provide independent checks for systematic errors, and reduce the time required to collect a calibration data set.

remote sensing AVIRIS Airborne Visible Infrared Im↗

Urban and regional land use analysis: CARETS and census cities experiment package

The author has identified the following significant results. Successful tentative calibration permits computer programs to be written to convert Skylab thermal tapes into line-printed graymaps showing actual surface radiation temperature distributions at the time of imaging. The calibrations will be further checked when atmospheric soundings are available. Success of Skylab calibration suggests that satellite are feasible platforms for thermal scanning and provide a much broader geographical field of view than is possible with airborne platforms.

Alexander, R.↗

The Optical Field Angle Distortion Calibration of HST Fine Guidance Sensors 1R and 3

To date five OFAD (Optical Field Angle Distortion) calibrations have been performed with a star field in M35, four on FGS3 and one on FGS1, all analyzed by the Astrometry Science Team. We have recently completed an improved FGS1R OFAD calibration. The ongoing Long Term Stability Tests have also been analyzed and incorporated into these calibrations, which are time-dependent due to on-orbit changes in the FGS. Descriptions of these tests and the results of our OFAD modeling are given. Because all OFAD calibrations use the same star field, we calibrate FGS 1 and FGS 3 simultaneously. This increases the precision of our input catalog,resulting in an improvement in both the FGS 1 and FGS 3 calibrations. A redetermination of the proper motions,using 12 years of HST data has significantly improved our calibration. Residuals to our OFAD modeling indicate that FGS 1 will provide astrometry superior to FGS 3 by approx. 20%. Past and future FGS astrometric science supported by these calibrations is briefly reviewed.

McArthur, B.↗

Analyzing Non Stationary Processes in Radiometers

The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory for many scientific and engineering applications. Non linear effects of the observation methodology is one of the most perplexing aspects to modeling non stationary processes. This perplexing problem was encountered when modeling the effect of non stationary receiver fluctuations on the performance of radiometer calibration architectures. Existing modeling approaches were found not applicable; particularly problematic is modeling processes across scales over which they begin to exhibit non stationary behavior within the time interval of the calibration algorithm. Alternatively, the radiometer output is modeled as samples from a sequence random variables; the random variables are treated using a conditional probability distribution function conditioned on the use of the variable in the calibration algorithm. This approach of treating a process as a sequence of random variables with non stationary stochastic moments produce sensible predictions of temporal effects of calibration algorithms. To test these model predictions, an experiment using the Millimeter wave Imaging Radiometer (MIR) was conducted. The MIR with its two black body calibration references was configured in a laboratory setting to observe a third ultra-stable reference (CryoTarget). The MIR was programmed to sequentially sample each of the three references in approximately a 1 second cycle. Data were collected over a six-hour interval. The sequence of reference measurements form an ensemble sample set comprised of a series of three reference measurements. Two references are required to estimate the receiver response. A third reference is used to estimate the uncertainty in the estimate. Typically, calibration algorithms are designed to suppress the non stationary effects of receiver fluctuations. By treating the data sequence as an ensemble collection, it is possible to apply temporal algorithms which exacerbate the non stationary effects. By varying the algorithm, information about the properties of the non stationary receiver fluctuations is obtained. Comparisons of analytical calculations and statistical analysis of data demonstrate impressive agreement.

Racette, Paul↗