Search NASA⌕ Search

SEARCH · Search NASA

Results for “Total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Total quality management - It works for aerospace information services

Today we are in the midst of information and 'total quality' revolutions. At the NASA STI Program's Center for AeroSpace Information (CASI), we are focused on using continuous improvements techniques to enrich today's services and products and to ensure that tomorrow's technology supports the TQM-based improvement of future STI program products and services. The Continuous Improvements Program at CASI is the foundation for Total Quality Management in products and services. The focus is customer-driven; its goal, to identify processes and procedures that can be improved and new technologies that can be integrated with the processes to gain efficiencies, provide effectiveness, and promote customer satisfaction. This Program seeks to establish quality through an iterative defect prevention approach that is based on the incorporation of standards and measurements into the processing cycle.

Erwin, James↗

Total electron scattering and electronic state excitations cross sections for O2, CO, and CH4

Available electron collision cross section data concerning total and elastic scattering, vibrational excitation, and ionization for O2, CO, and CH4 have been critically reviewed, and a set of cross sections for modeling of planetary atmospheric behavior is recommended. Utilizing these recommended cross sections, we derived total electronic state excitation cross sections and upper limits for dissociation cross sections, which in the case of CH4 should very closely equal the actual dissociation cross section.

Kanik, I.↗

Effects of vertical distribution of water vapor and temperature on total column water vapor retrieval error

Results are presented of a test of the physically based total column water vapor retrieval algorithm of Wentz (1992) for sensitivity to realistic vertical distributions of temperature and water vapor. The ECMWF monthly averaged temperature and humidity fields are used to simulate the spatial pattern of systematic retrieval error of total column water vapor due to this sensitivity. The estimated systematic error is within 0.1 g/sq cm over about 70 percent of the global ocean area; systematic errors greater than 0.3 g/sq cm are expected to exist only over a few well-defined regions, about 3 percent of the global oceans, assuming that the global mean value is unbiased.

Sun, Jielun↗

Tropical intercontinental optical measurement network of aerosol, precipitable water and total column ozone

A new generation of automatic sunphotometers is used to systematically monitor clear sky total column aerosol concentration and optical properties, precipitable water and total column ozone diurnally and annually in West Africa and South America. The instruments are designed to measure direct beam sun, solar aureole and sky radiances in nine narrow spectral bands from the UV to the near infrared on an hourly basis. The instrumentation and the algorithms required to reduce the data for subsequent analysis are described.

Holben, B. N.↗

Measurement of the Differential and Total Thrust and Torque of Six Full-Scale Adjustable-Pitch Propellers

Force measurements giving total thrust and torque, and propeller slip stream surveys giving differential thrust and torque were simultaneously made on each of six full-scale propellers in the 20-foot propeller-research tunnel of the National Advisory Committee for Aeronautics. They were adjustable-pitch metal propellers 9.5 feet in diameter; three had modified Clark Y blade sections and three had modified RAF-6 blade sections. This report gives the differential thrust and torque and the variation caused by changing the propeller tip speed and the pitch setting. The total thrust and torque obtained from integration of the thrust and torque distribution curves are compared with those obtained by direct force measurements.

Stickle, George W↗

Investigation at supersonic speeds of the variation with Reynolds number and Mach number of the total, base, and skin-friction drag of seven boattail bodies of revolution designed for minimum wave drag

An investigation has been conducted in the Langley 9-inch supersonic tunnel to determine the effect of the variation with Reynolds number and Mach number of the total, base, and skin-friction drag at zero lift of seven boattail bodies of revolution designed for minimum wave drag according to NACA TN 2550. The tests covered a Reynolds number range from approximately 1.0 x 10(6) to 10.0 x 10(6) at Mach numbers of 1.62, 1.93, and 2.41, respectively. The results show that base drag and, in general, the total drag increase with increasing values of the ratio of base area to maximum area B/S(sub max), although the results reported in NACA TN 3054 showed that the wave drag decreased with increasing values of B/S(sub max). The laminar skin-friction drag is in agreement with the theoretical predictions used, and, within the Mach number range of these tests, the simple Blasius incompressible theory gives a satisfactory prediction. Except for values of B/S (sub max) near 1, the Reynolds number of transition increases with increasing Mach number and as this ratio approaches 1 this variation is seen to reverse. These variations in Reynolds number of transition with Mach number appear to be associated with the changes in pressure gradient over the rear of the bodies.

Bromm, August F , Jr↗

The power of cross-functional teams in driving total quality

Garrett Canada, a Division of Allied-Signal Aerospace Canada, has been a member of the Canadian aerospace industry for 40 years. Although Garrett Canada has always been a profitable division with a solid market share, the changing and turbulent business environment and globalization of the aerospace industry has created new demands and challenges. The marketplace is demanding faster introduction of new products, as well as shorter leadtimes for repairs and spares. It was recognized that reducing cycle times for new products and for ongoing production would not only satisfy our customers, it would also enhance our business performance through reduced inventories, lower past due, and more responsiveness to change. It was evident that drastic function changes were required if we were to maintain our position as a premier aerospace supplier. The challenge was to convert a stable, somewhat slow-paced work environment with strong functional boundaries into a boundaryless world class team functioning in a total quality environment and focused on customer satisfaction. Complete and uncompromised customer satisfaction has become our driving force, with Total Quality being our engine to continuously improve our processes and increase our speed. The way in which this transition has been brought about is the subject of this presentation.

Mcclung, Tim M.↗

The application of total quality management principles to spacecraft mission operations

By now, the philosophies of Total Quality Management have had an impact on every aspect of American industrial life. The trail-blazing work of Deming, Juran, and Crosby, first implemented in Japan, has 're-migrated' across the Pacific and now plays a growing role in America's management culture. While initially considered suited only for a manufacturing environment, TQM has moved rapidly into the 'service' areas of offices, sales forces, and even fast-food restaurants. The next logical step has also been taken - TQM has found its way into virtually all departments of the Federal Government, including NASA. Because of this widespread success, it seems fair to ask whether this new discipline is directly applicable to the profession of spacecraft operations. The results of quality emphasis on OAO Corporation's contract at JPL provide strong support for Total Quality Management as a useful tool in spacecraft operations.

Sweetin, Maury↗

TOTAL user manual

Semi-Markov models can be used to analyze the reliability of virtually any fault-tolerant system. However, the process of delineating all of the states and transitions in the model of a complex system can be devastatingly tedious and error-prone. Even with tools such as the Abstract Semi-Markov Specification Interface to the SURE Tool (ASSIST), the user must describe a system by specifying the rules governing the behavior of the system in order to generate the model. With the Table Oriented Translator to the ASSIST Language (TOTAL), the user can specify the components of a typical system and their attributes in the form of a table. The conditions that lead to system failure are also listed in a tabular form. The user can also abstractly specify dependencies with causes and effects. The level of information required is appropriate for system designers with little or no background in the details of reliability calculations. A menu-driven interface guides the user through the system description process, and the program updates the tables as new information is entered. The TOTAL program automatically generates an ASSIST input description to match the system description.

Johnson, Sally C.↗

Modelling time variable and total eclipses of the millisecond pulsar PSR 1744-24A

The 11 ms pulsar PSR 1744-24A in the globular clusters Terzan 5 is the first and only known example of a binary eclipsing pulsar showing time-variable eclipses with irregular and nonsymmetric eclipse patterns. Occasionally, the pulsar eclipse becomes total, and no radio emission is detected for an extended period of time. We present here numerical results of a hydrodynamical model aimed at explaining the remarkable eclipse properties of PSR 1744-24A. We show that the hydrodynamic time scale for the partial or total pulsar enshrouding is of order of the orbital period for a relatively large mass loss rate, in agreement with observations. The time-variable eclipse egress positions imply that the mass loss rate from the companion varies within one orbital period. Hydrodynamic modelling of the mass outflow of PSR 1744-24A is of crucial importance for the understanding of a class of millisecond pulsars whose radio emission might be occasionally or permanently quenched by mass outflows from their companions. The properties of PSR 1744-24A suggest a new way of studying millisecond pulsars involving radio, X-ray, gamma-ray, and optical observations.

Tavani, Marco↗

TOMS total ozone data compared with northern latitude Dobson ground stations

Ozone measurements from the Total Ozone Mapping Spectrometer on the Nimbus 7 satellite are compared with ground-based measurements from five Dobson stations at northern latitudes to evaluate the accuracy of the TOMS data, particularly in regions north of 50 deg N. The measurements from the individual stations show mean differences from -2.5 percent up to plus 8.3 percent relative to TOMS measurements and two of the ground stations, Oslo and Longyearbyen, show a significant drift of plus 1.2 percent and plus 3.7 percent per year, respectively. It can be shown from nearly simultaneous measurements in two different wavelength double pairs at Oslo that at least 2 percent of the differences result from the use of the CC' wavelength double pair instead of the standard AD wavelength double pair. Since all Norwegian stations used the CC' wavelength double pair exclusively a similar error can be assumed for Tromso and Longyearbyren. A comparison between the tropospheric ozone content in TOMS data and from ECC ozonesonde measurements at Ny-Alesund and Bear Island shows that the amount of tropospheric ozone in the standard profiles used in the TOMS algorithm is too low, which leads to an error of about 2 percent in total ozone. Particularly at high solar zenith angles (greater than 80 deg), Dobson measurements become unreliable. They are up to 20 percent lower than TOMS measurements averaged over solar zenith angles of 88 deg to 89 deg.

Heese, B.↗

Depletions in winter total ozone values over southern England

A study has been made of the recently re-evaluated time series of daily total ozone values for the period 1979 to 1992 for southern England. The series consists of measurements made at two stations, Bracknell and Camborne. The series shows a steady decline in ozone values in the spring months over the period, and this is consistent with data from an earlier decade that has been published but not re-evaluated. Of exceptional note is the monthly mean for January 1992 which was very significantly reduced from the normal value, and was the lowest so far measured for this month. This winter was also noteworthy for a prolonged period during which a blocking anticyclone dominated the region, and the possibility existed that this was related to the ozone anomaly. It was possible to determine whether the origin of the low ozone value lay in ascending stratospheric motions. A linear regression analysis of ozone value deviation against 100hPa temperature deviations was used to reduce ozone values to those expected in the absence of high pressure. The assumption was made that the normal regression relation was not affected by atmospheric anomalies during the winter. This showed that vertical motions in the stratosphere only accounted for part of the ozone anomaly and that the main cause of the ozone deficit lay either in a reduced stratospheric circulation to which the anticyclone may be related or in chemical effects in the reduced stratospheric temperatures above the high pressure area. A study of the ozone time series adjusted to remove variations correlated with meteorological quantities, showed that during the period since 1979, one other winter, that of 1982/3, showed a similar although less well defined deficit in total ozone values.

Lapworth, A.↗

Total ozone trend over Cairo

A world wide interest in protecting ozone layer against manmade effects is now increasing. Assessment of the ozone depletion due to these activities depends on how successfully we can separate the natural variabilities from the data. The monthly mean values of total ozone over Cairo (30 05N) for the period 1968-1988, have been analyzed using the power spectral analysis technique. The technique used in this analysis does not depend on a pre-understanding of the natural fluctuations in the ozone data. The method depends on increasing the resolution of the spectral peaks in order to obtain the more accurate sinusoidal fluctuations with wavelength equal to or less than record length. Also it handles the possible sinusoidal fluctuations with wavelength equal to or less than record length. The results show that it is possible to detect some of the well known national fluctuations in the ozone record such as annual, semiannual, quasi-biennial and quasi-quadrennial oscillations. After separating the natural fluctuations from the ozone record, the trend analysis of total ozone over Cairo showed that a decrease of about -1.2% per decade has occurred since 1979.

Hassan, G. K. Y.↗

Airmass dependence of the Dobson total ozone measurements

For many years the airmass dependence of total ozone measurements at Belsk has been observed to vary noticeably from one day to another. Series of AD wavelength pairs measurements taken out to high airmass were analyzed and compared with the two parameter stray light model presented by Basher. The analysis extended to the series of CD measurements indicates the role of atmospheric attenuation in appearing the airmass dependence. The minor noon decline of total ozone has been observed in the CD measurement series similarly as in those of the AD wavelength pairs. Such errors may seriously affect the accuracy of CD measurements at high latitude stations and the observations derived in winter at middle latitude stations.

Degorska, M.↗

Profile shape dependence in backscattered ultraviolet satellite retrievals of total ozone

Total ozone operational algorithms use climatological mean ozone profiles. When the actual ozone profiles have significantly different shapes versus the climatology and the solar zenith angles are large, retrieved total ozone will have an error. Recalibrated SBUV profiles are used to estimate this error. Preliminary results suggest that, on the average, the change and variation in significant profiles shapes can to a large degree be estimated by the SBUV derived profiles. Preliminary results suggest the average error in the report algorithm ozone trend (trend in reported ozone) from profile shape is relatively small during the north hemisphere winter (less than 2 percent) for solar zenith angles less than 82 degrees (for 60 degrees North Latitude).

Taylor, S. L.↗

A new model for estimating total body water from bioelectrical resistance

Estimation of total body water (T) from bioelectrical resistance (R) is commonly done by stepwise regression models with height squared over R, H(exp 2)/R, age, sex, and weight (W). Polynomials of H(exp 2)/R have not been included in these models. We examined the validity of a model with third order polynomials and W. Methods: T was measured with oxygen-18 labled water in 27 subjects. R at 50 kHz was obtained from electrodes placed on the hand and foot while subjects were in the supine position. A stepwise regression equation was developed with 13 subjects (age 31.5 plus or minus 6.2 years, T 38.2 plus or minus 6.6 L, W 65.2 plus or minus 12.0 kg). Correlations, standard error of estimates and mean differences were computed between T and estimated T's from the new (N) model and other models. Evaluations were completed with the remaining 14 subjects (age 32.4 plus or minus 6.3 years, T 40.3 plus or minus 8 L, W 70.2 plus or minus 12.3 kg) and two of its subgroups (high and low) Results: A regression equation was developed from the model. The only significant mean difference was between T and one of the earlier models. Conclusion: Third order polynomials in regression models may increase the accuracy of estimating total body water. Evaluating the model with a larger population is needed.

Siconolfi, S. F.↗

Effect of heavy rain to the total received power

If the average power at the receiver is substantially reduced by heavy rain, the AGC (automatic gain control) circuit of the rain gauge will try to compensate this reduction by increasing the gain. If this happens, then the pulses created by rain drops are amplified more than they should be and the rainfall rate may be overestimated. If the effective diameter (blocking efficiency) of a particle is 2 mm and if the beam width is 2 cm, each particle will reduce the received power by 10 percent when it crosses the beam. Since the beam is blocked by water drops 75 percent of the total time according to the above calculation, the total received power may be reduced by 7.5 percent. To compensate this reduction to the reference value, the gain of amplifier will be increased by 8.1 percent. This increase of gain will increase all pulse sizes by the same fraction and result in the overestimate of the rainfall rate.

Iguchi, Toshio↗

Contingency maneuver strategies for the Total Ozone Mapping Spectrometer-Earth Probe (TOMS-EP)

The Total Ozone Mapping Spectrometer-Earth Probe (TOMS-EP) is a polar-orbiting spacecraft designed to measure total ozone levels in the Earth's atmosphere. The nominal mission orbit is a 955-kilometer circular Sun-synchronous orbit with an ascending node mean local crossing time (MLT) between 11:02 a.m. and 11:25 a.m. These two mean local ascending node times constitute the boundaries of the MLT box for this mission. The MLT boundaries were chosen to maintain the Sun-to-Earth-to-vehicle orbit-normal (SVN) angle within a preselected set of seasonally independent boundaries. Because the SVN angle is seasonally dependent, but the MLT is not, contingency options for correcting the MLT of orbital states that fall outside of the required MLT range become time dependent. This paper focuses on contingency orbit adjustment strategies developed at the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) during the mission planning phase of TOMS-EP. Time-dependent delta-V strategies are presented for correcting mission orbit states lying outside of the MLT range. Typically, passive control of the MLT drift rate can be used to restore the orbit state to the required MLT before a seasonal violation of SVN angle constraints can occur. Passive control of the MLT drift rate is obtained through adjustment of the semimajor axis and/or the inclination. The time between initial arrival on orbit at an 'out-of-the box' MLT state and violation of the SVN angle constraints is always less than or equal to 1 year. The choice of which parameter(s) to adjust is dictated by the duration of this time period, the desired mission lifetime, the delta-V cost, and operational constraints.

Kestler, James↗