Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Determination of GPS orbits to submeter accuracy

Orbits for satellites of the Global Positioning System (GPS) were determined with submeter accuracy. Tests used to assess orbital accuracy include orbit comparisons from independent data sets, orbit prediction, ground baseline determination, and formal errors. One satellite tracked 8 hours each day shows rms error below 1 m even when predicted more than 3 days outside of a 1-week data arc. Differential tracking of the GPS satellites in high Earth orbit provides a powerful relative positioning capability, even when a relatively small continental U.S. fiducial tracking network is used with less than one-third of the full GPS constellation. To demonstrate this capability, baselines of up to 2000 km in North America were also determined with the GPS orbits. The 2000 km baselines show rms daily repeatability of 0.3 to 2 parts in 10 to the 8th power and agree with very long base interferometry (VLBI) solutions at the level of 1.5 parts in 10 to the 8th power. This GPS demonstration provides an opportunity to test different techniques for high-accuracy orbit determination for high Earth orbiters. The best GPS orbit strategies included data arcs of at least 1 week, process noise models for tropospheric fluctuations, estimation of GPS solar pressure coefficients, and combine processing of GPS carrier phase and pseudorange data. For data arc of 2 weeks, constrained process noise models for GPS dynamic parameters significantly improved the situation.

Bertiger, W. I.↗

Directional errors of movements and their correction in a discrete tracking task

Subjects can correct their own errors of movement more quickly than they can react to external stimuli by using three general categories of feedback: (1) knowledge of results, primarily visually mediated; (2) proprioceptive or kinaesthetic such as from muscle spindles and joint receptors, and (3) corollary discharge or efference copy within the central nervous system. The effects of these feedbacks on simple reaction time, choice reaction time, and error correction time were studied in four normal human subjects. The movement used was plantarflexion and dorsiflexion of the ankle joint. The feedback loops were modified, by changing the sign of the visual display to alter the subject's perception of results, and by applying vibration at 100 Hz simultaneously to both the agonist and antagonist muscles of the ankle joint. The central processing was interfered with when the subjects were given moderate doses of alcohol (blood alcohol concentration levels of up to 0.07%). Vibration and alcohol increase both the simple and choice reaction times but not the error correction time.

Jaeger, R. J.↗

An error analysis of the recovery capability of the relative sea-surface profile over the Puerto Rican trench from multi-station and ship tracking of GEOS-2

Error analyses were performed to examine the height error in a relative sea-surface profile as determined by a combination of land-based multistation C-band radars and optical lasers and one ship-based radar tracking the GEOS 2 satellite. It was shown that two relative profiles can be obtained: one using available south-to-north passes of the satellite and one using available north-to-south type passes. An analysis of multi-station tracking capability determined that only Antigua and Grand Turk radars are required to provide satisfactory orbits for south-to-north type satellite passes, while a combination of Merritt Island, Bermuda, and Wallops radars provide secondary orbits for north-to-south passes. Analysis of ship tracking capabilities shows that high elevation single pass range-only solutions are necessary to give only moderate sensitivity to systematic error effects.

Stanley, H. R.↗

Accuracy of Robotic Radiosurgical Liver Treatment Throughout the Respiratory Cycle

Purpose: To quantify random uncertainties in robotic radiosurgical treatment of liver lesions with real-time respiratory motion management. Methods and Materials: We conducted a retrospective analysis of 27 liver cancer patients treated with robotic radiosurgery over 118 fractions. The robotic radiosurgical system uses orthogonal x-ray images to determine internal target position and correlates this position with an external surrogate to provide robotic corrections of linear accelerator positioning. Verification and update of this internal–external correlation model was achieved using periodic x-ray images collected throughout treatment. To quantify random uncertainties in targeting, we analyzed logged tracking information and isolated x-ray images collected immediately before beam delivery. For translational correlation errors, we quantified the difference between correlation model–estimated target position and actual position determined by periodic x-ray imaging. To quantify prediction errors, we computed the mean absolute difference between the predicted coordinates and actual modeled position calculated 115 milliseconds later. We estimated overall random uncertainty by quadratically summing correlation, prediction, and end-to-end targeting errors. We also investigated relationships between tracking errors and motion amplitude using linear regression. Results: The 95th percentile absolute correlation errors in each direction were 2.1 mm left–right, 1.8 mm anterior–posterior, 3.3 mm cranio–caudal, and 3.9 mm 3-dimensional radial, whereas 95th percentile absolute radial prediction errors were 0.5 mm. Overall 95th percentile random uncertainty was 4 mm in the radial direction. Prediction errors were strongly correlated with modeled target amplitude (r=0.53-0.66, P<.001), whereas only weak correlations existed for correlation errors. Conclusions: Study results demonstrate that model correlation errors are the primary random source of uncertainty in Cyberknife liver treatment and, unlike prediction errors, are not strongly correlated with target motion amplitude. Aggregate 3-dimensional radial position errors presented here suggest the target will be within 4 mm of the target volume for 95% of the beam delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of uncertainty on manual tracking performance

Transient phenomena and target acquisition modes associated with interrupted observations during ground-to-air AA tracking were investigated. Using a two-axes control stick, the subjects tracked a computer-generated airplane image on a CRT display. The airplane image excuted a low-level straight pass. At certain pseudo-random times during each 25-second run, the screen was blanked for a period of one second. When the target image reappeared, the subjects reacquired it and continued tracking, attempting to minimize vector RMS error for the entire run (including the blanked period). The results reveal an increase both in tracking error and in error variance during the blanked period, only when the target disappears while in the crossover region. Blanking at other times effected increased variance but had no effect on the mean error. A blanking period just before crossover produced an increase lag while a blanking just after crossover resulted in a lead and thus made the error curve more symmetric.

Ephrath, A. R.↗

Navigation analysis for Viking 1979, option B

A parametric study performed for 48 trans-Mars reference missions in support of the Viking program is reported. The launch dates cover several months in the year 1979, and each launch date has multiple arrival dates in 1980. A plot of launch versus arrival dates with case numbers designated for reference purposes is included. The analysis consists of the computation of statistical covariance matrices based on certain assumptions about the ground-based tracking systems. The error model statistics are listed in tables. Tracking systems were assumed at three sites: Goldstone, California; Canberra, Australia; and Madrid, Spain. The tracking data consisted of range and Doppler measurements taken during the tracking intervals starting at E-30(d) and ending at E-10(d) for the control data and ending at E-18(h) for the knowledge data. The control and knowledge covariance matrices were delivered to the Planetary Mission Analysis Branch for inputs into a delta V dispersion analysis.

Mitchell, P. H.↗

Sensitivity of SLR baselines to errors in Earth orientation

The sensitivity of inter station distances derived from Satellite Laser Ranging (SLR) to errors in Earth orientation is discussed. An analysis experiment is performed which imposes a known polar motion error on all of the arcs used over this interval. The effect of the averaging of the errors over the tracking periods of individual sites is assessed. Baselines between stations that are supported by a global network of tracking stations are only marginally affected by errors in Earth orientation. The global network of stations retains its integrity even in the presence of systematic changes in the coordinate frame. The effect of these coordinate frame changes on the relative locations of the stations is minimal.

Smith, D. E.↗

Flight demonstrations of curved, descending approaches and automatic landings using time referenced scanning beam guidance

The Terminal Configured Vehicle (TCV) program operates a Boeing 737 modified to include a second cockpit and a large amount of experimental navigation, guidance and control equipment for research on advanced avionics systems. Demonstration flights to include curved approaches and automatic landings were tracked by a phototheodolite system. For 50 approaches during the demonstration flights, the following results were obtained: the navigation system, using TRSB guidance, delivered the aircraft onto the 3 nautical mile final approach leg with an average overshoot of 25 feet past centerline, subjet to a 2-sigma dispersion of 90 feet. Lateral tracking data showed a mean error of 4.6 feet left of centerline at the category 1 decision height (200 feet) and 2.7 feet left of centerline at the category 2 decision height (100 feet). These values were subject to a sigma dispersion of about 10 feet. Finally, the glidepath tracking errors were 2.5 feet and 3.0 feet high at the category 1 and 2 decision heights, respectively, with a 2 sigma value of 6 feet.

White, W. F.↗

On the internal target model in a tracking task

An optimal control model for predicting operator's dynamic responses and errors in target tracking ability is summarized. The model, which predicts asymmetry in the tracking data, is dependent on target maneuvers and trajectories. Gunners perception, decision making, control, and estimate of target positions and velocity related to crossover intervals are discussed. The model provides estimates for means, standard deviations, and variances for variables investigated and for operator estimates of future target positions and velocities.

Caglayan, A. K.↗

TH-AB-202-04: Auto-Adaptive Margin Generation for MLC-Tracked Radiotherapy

Purpose: To develop an auto-adaptive margin generator for MLC tracking. The generator is able to estimate errors arising in image guided radiotherapy, particularly on an MR-Linac, which depend on the latencies of machine and image processing, as well as on patient motion characteristics. From the estimated error distribution, a segment margin is generated, able to compensate errors up to a user-defined confidence. Method: In every tracking control cycle (TCC, 40ms), the desired aperture D(t) is compared to the actual aperture A(t), a delayed and imperfect representation of D(t). Thus an error e(t)=A(T)-D(T) is measured every TCC. Applying kernel-density-estimation (KDE), the cumulative distribution (CDF) of e(t) is estimated. With CDF-confidence limits, upper and lower error limits are extracted for motion axes along and perpendicular leaf-travel direction and applied as margins. To test the dosimetric impact, two representative motion traces were extracted from fast liver-MRI (10Hz). The traces were applied onto a 4D-motion platform and continuously tracked by an Elekta Agility 160 MLC using an artificially imposed tracking delay. Gafchromic film was used to detect dose exposition for static, tracked, and error-compensated tracking cases. The margin generator was parameterized to cover 90% of all tracking errors. Dosimetric impact was rated by calculating the ratio between underexposed points (>5% underdosage) to the total number of points inside FWHM of static exposure. Results: Without imposing adaptive margins, tracking experiments showed a ratio of underexposed points of 17.5% and 14.3% for two motion cases with imaging delays of 200ms and 300ms, respectively. Activating the margin generated yielded total suppression (<1%) of underdosed points. Conclusion: We showed that auto-adaptive error compensation using machine error statistics is possible for MLC tracking. The error compensation margins are calculated on-line, without the need of assuming motion or machine models. Further strategies to reduce consequential overdosages are currently under investigation. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.

60 APPLIED LIFE SCIENCES↗

Soft-error generation due to heavy-ion tracks in bipolar integrated circuits

Both bipolar and MOS integrated circuits have been empirically demonstrated to be susceptible to single-particle soft-error generation, commonly referred to as single-event upset (SEU), which is manifested in a bit-flip in a latch-circuit construction. Here, the intrinsic characteristics of SEU in bipolar (static) RAM's are demonstrated through results obtained from the modeling of this effect using computer circuit-simulation techniques. It is shown that as the dimensions of the devices decrease, the critical charge required to cause SEU decreases in proportion to the device cross-section. The overall results of the simulations are applicable to most integrated circuit designs.

Zoutendyk, J. A.↗

Preliminary Error Characterization and Parametric Error Model for the Automatic Dependent Surveillance - Contract Extended Projected Profile Message

A critical component of Trajectory-Based Operations (TBO) is the ability for a consistent and accurate 4-dimensional trajectory (4DT) to be shared and synchronized between airborne and ground systems as well as amongst various ground automation systems. The Aeronautical Telecommunication Network—Baseline 2 (ATN-B2) standard defines the Extended Projected Profile (EPP) trajectory that can be sent via Automatic Dependent Surveillance-Contract (ADS-C) from an aircraft to ground automation. The EPP trajectory message contains a representation of the reference trajectory from an aircraft’s Flight Management System (FMS). In this work, a set of scenarios were run in a high-fidelity aircraft and FMS simulation to perform an initial characterization of EPP trajectory errors under a given set of conditions. The parameters investigated were the route length, route type, wind magnitude error, wind direction error, and with and without a required time-of-arrival (RTA) constraint. In addition, linear regression was used to identify a set of EPP error models for the cross-track, vertical, and time errors.

Guerreiro, Nelson M.↗