Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Impact Testing and Simulation of a Sinusoid Foam Sandwich Energy Absorber

A sinusoidal-shaped foam sandwich energy absorber was developed and evaluated at NASA Langley Research Center through multi-level testing and simulation performed under the Transport Rotorcraft Airframe Crash Testbed (TRACT) research project. The energy absorber, designated the "sinusoid," consisted of hybrid carbon- Kevlar® plain weave fabric face sheets, two layers for each face sheet oriented at +/-45deg with respect to the vertical or crush direction, and a closed-cell ELFOAM(TradeMark) P200 polyisocyanurate (2.0-lb/ft3) foam core. The design goal for the energy absorber was to achieve an average floor-level acceleration of between 25- and 40-g during the full-scale crash test of a retrofitted CH-46E helicopter airframe, designated TRACT 2. Variations in the design were assessed through quasi-static and dynamic crush testing of component specimens. Once the design was finalized, a 5-ft-long subfloor beam was fabricated and retrofitted into a barrel section of a CH-46E helicopter. A vertical drop test of the barrel section was conducted onto concrete to evaluate the performance of the energy absorber prior to retrofit into TRACT 2. Finite element models were developed of all test articles and simulations were performed using LSDYNA ®, a commercial nonlinear explicit transient dynamic finite element code. Test analysis results are presented for the sinusoid foam sandwich energy absorber as comparisons of load-displacement and acceleration-time-history responses, as well as predicted and experimental structural deformations and progressive damage for each evaluation level (component testing through barrel section drop testing).

Jackson, Karen E.↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Effect of transient winds on the flow quality of an open-circuit wind-tunnel model

The effect of a transient wind on the test-section flow quality of an open-circuit wind tunnel was investigated experimentally. The investigation was restricted to transient wind effects associated with the inlet. A small open-circuit wind tunnel was placed outside in the real wind environment. Test-section speed and angularity as well as wind speed and direction was measured by high-response instrumentation. The inlet configuration was varied with a set of screens, a removable honeycomb, and a removable inlet lip. Acceptable flow was obtained at all wind angles and for wind- to test-section-velocity ratios up to 0.4 with an inlet configuration having five screens, a honeycomb, and a lip. With inlet configurations sensitive to winds, a transient wind parallel to the tunnel axis produced local fluctuations in test-section speed and angularity; however, oscillation of the average test-section speed was not evident. The effect of wind direction was negligible up to wind angles of 45 deg relative to the tunnel axis. At larger wind angles, flow distortions occurred primarily on the windward side of the test section.

Breunlin, D. C.↗

Tundra SGS – Critical Importance of Site-Specific Injectivity Testing for Carbon Dioxide Injection Well Simulation Calibration

Paper presented at 16th International Conference on Greenhouse Gas Control Technologies (GHGT-16), October 23–27, 2022, Lyon, France. Brine injectivity tests were conducted on both the Broom Creek (BC) and Deadwood (DW) storage formations in one of the cored stratigraphic test wells prior to finalized simulations. The injectivity tests entailed injection of brine into the formations, followed by shutting in the wells. The shut-in duration represents the fall-off period which was used to carry out pressure transient analyses of the tests. The analysis of injectivity tests indicated that core-indicated and modeled permeability distributions should be conservatively multiplied by 2.5× and 5× in the BC and DW geologic models, respectively, prior to numerical simulations of CO 2 injection using Computer Modelling Group’s (CMG’s) GEM equation-of-state reservoir simulator. The scaler permeability multipliers allowed the fluid flow simulations to fully represent well test-measured injection well rates in the respective formations.

20 FOSSIL-FUELED POWER PLANTS↗

Failure Modes in Capacitors When Tested Under a Time-Varying Stress

Steady step surge testing (SSST) is widely applied to screen out potential power-on failures in solid tantalum capacitors. The test simulates the power supply's on and off characteristics. Power-on failure has been the prevalent failure mechanism for solid tantalum capacitors for decoupling applications. On the other hand, the SSST can also be reviewed as an electrically destructive test under a time-varying stress. It consists of rapidly charging the capacitor with incremental voltage increases, through a low resistance in series, until the capacitor under test is electrically shorted. Highly accelerated life testing (HALT) is usually a time-efficient method for determining the failure mechanism in capacitors; however, a destructive test under a time-varying stress like SSST is even more effective. It normally takes days to complete a HALT test, but it only takes minutes for a time-varying stress test to produce failures. The advantage of incorporating specific time-varying stress into a statistical model is significant in providing an alternative life test method for quickly revealing the failure modes in capacitors. In this paper, a time-varying stress has been incorporated into the Weibull model to characterize the failure modes. The SSST circuit and transient conditions to correctly test the capacitors is discussed. Finally, the SSST was applied for testing polymer aluminum capacitors (PA capacitors), Ta capacitors, and multi-layer ceramic capacitors with both precious metal electrode (PME) and base-metal-electrodes (BME). It appears that testing results are directly associated to the dielectric layer breakdown in PA and Ta capacitors and are independent on the capacitor values, the way the capacitors being built, and the manufactures. The testing results also reveal that ceramic capacitors exhibit breakdown voltages more than 20 times the rated voltage, and the breakdown voltages are inverse proportional to the dielectric layer thickness. The possibility of ceramic capacitors in front-end decoupling applications to block the surge noise from a power supply is also discussed.

Liu, David (Donhang)↗

Functional fiber-optic sensors embedded in stainless steel components using ultrasonic additive manufacturing for distributed temperature and strain measurements

The nuclear industry is progressing toward microreactors that can be factory assembled and deployed to remote regions for reliable, scalable power generation. However, the reduced power output requires enhanced monitoring capabilities to reduce staffing and eventually move toward autonomous control to improve the economics of microreactors. The ability to embed sensors such as fiber-optics, which can provide spatially distributed temperature and strain measurements, within microreactor components for real-time health monitoring would be particularly advantageous. Recent advances in ultrasonic additive manufacturing (UAM) have demonstrated the successful embedding of fiber-optics in soft materials such as Al and Cu by placing the sensors in machined cavities and ultrasonically welding over the top with thin foils. This article reports the first successful embedment of fiber-optic sensors and thermocouples within a common nuclear reactor material, SS304, via UAM. UAM parameters were first explored with simple plate geometries before moving to more complex geometries, such as pipes and other test articles for heat pipe–based microreactors. Select samples were sectioned for microscopy to evaluate the sensor/foil and foil/foil interfaces from samples fabricated by using 100% SS304 foils vs. foils plated with a Ni coating to improve UAM bonding. Furthermore, embedding metal-coated, low-bend loss fibers resulted in greatly reduced signal attenuation and adequate compressive residual strain in the embedded region to ensure successful strain coupling. Pipe specimen functional testing was performed by monitoring temperature and strain during transient and steady-state thermal testing.

36 MATERIALS SCIENCE↗

Hybrid bearings for LH2 and LO2 turbopumps

Hybrid combinations of hydrostatic and ball bearings can improve bearing performance for liquid hydrogen and liquid oxygen turbopumps. Analytic studies were conducted to optimize hybrid bearing designs for the SSME-type turbopump conditions. A method to empirically determine damping coefficients was devised. Four hybrid bearing configurations were designed, and three were fabricated. Six hybrid and hydrostatic-only bearing configurations will be tested for steady-state and transient performance, and quantification of damping coefficients. The initial tests were conducted with the liquid hydrogen bearing.

Butner, M. F.↗

Artemis IV Docking in Radiation Belt Charging Environment

NASA’s Artemis IV mission is planned to deliver the International Habitation Module (I-Hab) to the Gateway space station in lunar orbit. The I-Hab will be launched aboard the Space Launch System (SLS) vehicle as a co-manifested payload with the Orion spacecraft. After translunar injection begins, the Orion spacecraft will separate from the SLS Exploration Upper Stage (EUS) and then dock with the I-Hab to extract it from the EUS. Because of the altitude, orientation, and time for this to occur, the vehicle-to-vehicle potential between the I-Hab/EUS vehicle and Orion spacecraft could exceed several thousand volts. The docking of these two spacecrafts with such large differential potentials presents a challenge for the vehicles. This presentation describes the space environments at the docking altitude, the calculated vehicle-to-vehicle potential, and the possible impacts of the resulting voltage and current transients occurring at first contact. Additionally, possible risk mitigation tests to demonstrate compatibility with the transient current and voltages will be presented.

Matthew Mccollum↗

Numerical analysis of pulse facility transient flow through a supersonic combustion model

The supersonic high enthalpy flow from a shock tunnel facility flowing through a two-dimensional duct simulating a combustor has been computed for two test conditions for both steady and transient inflow. The nominal test conditions had stagnation enthalpies of 4.3 and 12.1 MJ/kg, with corresponding flight Mach numbers of 9 and 16, respectively. A full Navier-Stokes code (SPARK) was used to compute the flow development and the mixing of a hydrogen jet injected from the base of a central strut. Results of the calculations are presented and compared with wall pressure data. Additional comparisons of the transient and steady inflow results are presented to assess the effect of transient flow on the data. This paper presents a status of the progress in applying CFD codes to analyze the transient flow from a pulse facility.

Rogers, R. Clayton↗

Development of an Aeroelastic Modeling Capability for Transient Nozzle Side Load Analysis

Lateral nozzle forces are known to cause severe structural damage to any new rocket engine in development during test. While three-dimensional, transient, turbulent, chemically reacting computational fluid dynamics methodology has been demonstrated to capture major side load physics with rigid nozzles, hot-fire tests often show nozzle structure deformation during major side load events, leading to structural damages if structural strengthening measures were not taken. The modeling picture is incomplete without the capability to address the two-way responses between the structure and fluid. The objective of this study is to develop a coupled aeroelastic modeling capability by implementing the necessary structural dynamics component into an anchored computational fluid dynamics methodology. The computational fluid dynamics component is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, while the computational structural dynamics component is developed in the framework of modal analysis. Transient aeroelastic nozzle startup analyses of the Block I Space Shuttle Main Engine at sea level were performed. The computed results from the aeroelastic nozzle modeling are presented.

Wang, Ten-See↗

Development of an Aeroelastic Modeling Capability for Transient Nozzle Side Load Analysis

Lateral nozzle forces are known to cause severe structural damage to any new rocket engine in development during test. While three-dimensional, transient, turbulent, chemically reacting computational fluid dynamics methodology has been demonstrated to capture major side load physics with rigid nozzles, hot-fire tests often show nozzle structure deformation during major side load events, leading to structural damages if structural strengthening measures were not taken. The modeling picture is incomplete without the capability to address the two-way responses between the structure and fluid. The objective of this study is to develop a coupled aeroelastic modeling capability by implementing the necessary structural dynamics component into an anchored computational fluid dynamics methodology. The computational fluid dynamics component is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, while the computational structural dynamics component is developed in the framework of modal analysis. Transient aeroelastic nozzle startup analyses of the Block I Space Shuttle Main Engine at sea level were performed. The computed results from the aeroelastic nozzle modeling are presented.

Wang, Ten-See↗

Development and Standup Testing of a System to Observe Fission Gas Release During Transient Heating of Nuclear Fuel Element Segments

As part of an effort to increase the burnup of nuclear fuels used in Light Water Reactors, the mechanisms and timing of fission gas release during high temperature transients must be studied. In this work, a system was built to observe fission gas release of fuel element sections under evacuated conditions, at temperatures up to 800 °C. System capabilities and limitations are overviewed in this report. The system was further tested with a hydrogen-infused titanium foils and gas release was observed in agreement with literature observations. Pressure was monitored with two sensors, and temperature was monitored using a thermocouple and a pyrometer with continuous visual imaging.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diesel Oxidation Catalyst Performance with Biodiesel Formulations

Biodiesel (i.e., mono-alkyl esters of long chain fatty acids derived from vegetable oils and animal fats) is a renewable diesel fuel providing life-cycle greenhouse gas emission reductions relative to petroleum-derived diesel. With the expectation that there would be widespread use of biodiesel as a substitute for ultra-low sulfur diesel (ULSD), there have been many studies looking into the effects of biodiesel on engine and aftertreatment, particularly its compatibility to the current aftertreatment technologies. The objective of this study was to generate experimental data to measure the effectiveness of a current technology diesel oxidation catalysts (DOC) to oxidize soy-based biodiesel at various blend levels with ULSD. Biodiesel blends from 0 to 100% were evaluated on an engine using a conventional DOC. In the steady-state performance test where fuel dosing rate was increased at fixed DOC inlet temperature, B20 performed similarly to ULSD at the lowest flow rate or exhaust temperature over 340 degrees C for medium and high flows. B50 blends performed nearly as well under most conditions. Higher blends exhibited reduced thermal efficiency and DOC outlet temperature with increasing dosing rate under most conditions and required exhaust temperatures over 400 degrees C to achieve or nearly achieve performance similar to ULSD. In the steady-state light of test where fuel dosing rate is fixed but exhaust temperature is increased incrementally, B20 generally performed similarly to ULSD at the highest inlet temperature, with only minor deficiencies at lower temperatures. Higher blends exhibited lower thermal efficiency and did not achieve as high DOC outlet temperatures. In the transient light-off test light-off temperature for ULSD was typically less than 225 degrees C, while for B100 it ranged from 290 degrees C to 330 degrees C. Based on the data set, it can be concluded that biodiesel fuels have a higher light-off temperature primarily because of their higher boiling points, with a minor secondary impact of their lower energy content.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Testing of the NASA Hypersonics Project Combined Cycle Engine Large Scale Inlet Mode Transition Experiment (CCE LlMX)

Status on an effort to develop Turbine Based Combined Cycle (TBCC) propulsion is described. This propulsion technology can enable reliable and reusable space launch systems. TBCC propulsion offers improved performance and safety over rocket propulsion. The potential to realize aircraft-like operations and reduced maintenance are additional benefits. Among most the critical TBCC enabling technologies are: 1) mode transition from turbine to scramjet propulsion, 2) high Mach turbine engines and 3) TBCC integration. To address these TBCC challenges, the effort is centered on a propulsion mode transition experiment and includes analytical research. The test program, the Combined-Cycle Engine Large Scale Inlet Mode Transition Experiment (CCE LIMX), was conceived to integrate TBCC propulsion with proposed hypersonic vehicles. The goals address: (1) dual inlet operability and performance, (2) mode-transition sequences enabling a switch between turbine and scramjet flow paths, and (3) turbine engine transients during transition. Four test phases are planned from which a database can be used to both validate design and analysis codes and characterize operability and integration issues for TBCC propulsion. In this paper we discuss the research objectives, features of the CCE hardware and test plans, and status of the parametric inlet characterization testing which began in 2011. This effort is sponsored by the NASA Fundamental Aeronautics Hypersonics project

Saunders, J. D.↗

Single event induced transients in I/O devices - A characterization

The results of single-event upset (SEU) testing performed to evaluate the parametric transients, i.e., amplitude and duration, in several I/O devices, and the impact of these transients are discussed. The failure rate of these devices is dependent on the susceptibility of interconnected devices to the resulting transient change in the output of the I/O device. This failure rate, which is a function of the susceptibility of the interconnected device as well as the SEU response of the I/O device itself, may be significantly different from an upset rate calculated without taking these factors into account. The impact at the system level is discussed by way of an example.

Newberry, D. M.↗