Search NASA⌕ Search

SEARCH · Search NASA

Results for “WALLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Evolutionary divergence of β–expansin structure and function in grasses parallels emergence of distinctive primary cell wall traits

Summary Expansins are wall‐loosening proteins that promote the extension of primary cell walls without the hydrolysis of major structural components. Previously, proteins from the EXPA (α–expansin) family were found to loosen eudicot cell walls but to be less effective on grass cell walls, whereas the reverse pattern was found for EXPB (β–expansin) proteins obtained from grass pollen. To understand the evolutionary and structural bases for the selectivity of EXPB action, we assessed the extension (creep) response of cell walls from diverse monocot families to EXPA and EXPB treatments. Cell walls from Cyperaceae and Juncaceae (families closely related to grasses) displayed a typical grass response (‘β–response’). Walls from more distant monocots, including some species that share with grasses high levels of arabinoxylan, responded preferentially to α–expansins (‘α–response’), behaving in this regard like eudicots. An expansin with selective activity for grass cell walls was detected in Cyperaceae pollen, coinciding with the expression of genes from the divergent EXPB –I branch that includes grass pollen β–expansins. The evolutionary origin of this branch was located within Poales on the basis of phylogenetic analyses and its association with the ‘sigma’ whole‐genome duplication. Accelerated evolution in this branch has remodeled the protein surface in contact with the substrate, potentially for binding highly substituted arabinoxylan. We propose that the evolution of the divergent EXPB –I group made a fundamental change in the target and mechanism of wall loosening in the grass lineage possible, involving a new structural role for xylans and the expansins that target them.

Sampedro, Javier↗

Burst Pressure Solutions of Thin and Thick-Walled Cylindrical Vessels

Pressure vessels (PVs) are widely used in the energy industry. Accurate burst pressure is critical to structural design and safe operation for both thin and thick-walled PVs. The traditional strength theories utilized a single-parameter material property, such as the yield stress or the ultimate tensile stress (UTS) to develop failure models for determining the yield or ultimate pressure carrying capacity in the PV design. The UTS-based Barlow formula is a typical burst pressure model developed from the Tresca strength theory that provides the basis for developing regulation rules and failure models for different industry design codes, such as ASME BPVC, ASME B31.3, and ASME B31G, among others. In order to reduce the conservatism of the Tresca strength model, ASME BPVC recently adapted failure models developed from the von Mises strength theory for the PV design and analysis. It has been commonly accepted that the burst pressure of pipelines depends on the UTS and strain hardening exponent, n, of the pipeline steel. An average shear stress yield theory was thus developed, and the Zhu-Leis solution of burst pressure was obtained as a function of UTS and n for thin-walled line pipes. Experiments showed that the Zhu-Leis solution provides an accurate, reliable prediction of burst pressure for defect-free thin-walled pipes. In order to extend the Zhu–Leis solution to thick-walled cylindrical PVs, this paper defined three new flow stresses, modified the traditional strength theories, and obtained three new burst pressure solutions that are valid for both thin and thick-walled cylindrical vessels. The proposed flow stresses are able to describe the tensile strength and the plastic flow response of PVs for a strain hardening steel. The associated strength theories were then developed in terms of the Tresca, von Mises, and Zhu-Leis yield criteria. From these new strength theories, three burst pressure solutions were obtained for thick-walled cylinders, where the von Mises solution is an upper bound prediction, the Tresca solution is a lower bound prediction, and the Zhu-Leis solution is an intermediate prediction of burst pressure for thick-walled cylinders. Lastly, the proposed burst pressure solutions were evaluated and validated by two large datasets of full-scale burst tests for thick-walled tubes and for thin-walled pipes.

42 ENGINEERING↗

Assessment of Machine Learning Wall Modeling Approaches for Large Eddy Simulation of Gas Turbine Film Cooling Flows: An a Priori Study

Here, in this work, a priori analysis of machine learning (ML) strategies is carried out with the goal of data-driven wall modeling for large eddy simulation (LES) of gas turbine film cooling flows. High-fidelity flow datasets are extracted from wall-resolved LES (WRLES) of flow over a flat plate interacting with the coolant flow supplied by a single row of 7-7-7 shaped cooling holes inclined at 30 degrees with the flat plate at different blowing ratios (BR). The WRLES are performed using the high-order Nek5000 spectral element computational fluid dynamics (CFD) solver. Light gradient boosting machine (LightGBM) is employed as the ML algorithm for the data-driven wall model. Parametric tests are conducted to systematically assess the influence of a wide range of input flow features (velocity components, velocity gradients, pressure gradients, and fluid properties) on the accuracy of ML wall model with respect to prediction of wall shear stress. In addition, the use of spatial stencil and time delay is also explored within the ML wall modeling framework. It is shown that features associated with gradients of the streamwise and spanwise velocity components have a major impact on the prediction fidelity of wall model, while the effect of gradients of wall-normal velocity component is found to be negligible. Moreover, adding flow feature information from an x-y-z spatial stencil significantly improves the ML model accuracy and generalizability compared to just using local flow features from the matching location. Overall, highest prediction accuracy is achieved when both spatial stencil and time delay features are incorporated within the data-driven wall modeling paradigm.

33 ADVANCED PROPULSION SYSTEMS↗

Cylinder Test Wall Velocity: Experimental and Simulated Data

The cylinder test consists of a cylinder of high explosives (HE) within a thin walled copper tube. A detonation wave is initiated at one end of the cylinder. After propagating a few tube diameters, the flow behind the detonation wave approaches a steady state and the outward wall motion is measured; either using a streak camera to record the radial expansion of the wall (from which a wall velocity can be inferred) or a VISAR or PDV probe to measure a component of the wall velocity. The wall acceleration is related to the pressure along the release isentrope from the detonation state. Consequently, cylinder test data are used to calibrate equation of state (EOS) models for HE products. Model EOS parameters are fit by comparing the experimental data to simulated data from hydro codes. The simulated data consists of the particle velocity along a Lagrangian trajectory originating on the surface of the wall. The purpose of this note is to describe what the experiments actually measure, and to relate the experimental wall velocity to the physical velocity along a particle trajectory. Data for PBX 9501 is used to illustrate the differences among the experimental wall velocities and the particle velocity obtain from a simulation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Moisture Management for High R-Value Walls

The following report explains the moisture-related concerns for High R-value wall assemblies and discusses past Building America research work that informs this study. Hygrothermal simulations were prepared for several common approaches to High R-value wall construction in six cities (Houston, Atlanta, Seattle, St. Louis, Chicago, and International Falls) representing a range of climate zones (2, 3, 4C, 4, 5A, and 7, respectively). The simulations are informed by experience gained from past research in this area and validated by field measurement and forensic experience. The modeling program was developed to assess the moisture durability of the wall assemblies based on three primary sources of moisture: construction moisture, air leakage condensation, and bulk water leakage. The peak annual moisture content of the wood based exterior sheathing was used to comparatively analyze the response to the moisture loads for each of the walls in each given city. Walls which experienced sheathing moisture contents between 20% and 28% were identified as risky, whereas those exceeding 28% were identified as very high risk. All of the wall assemblies perform well under idealized conditions. However, only the walls with exterior insulation, or cavity insulation which provides a hygrothermal function similar to exterior insulation, perform adequately when exposed to moisture loads. Walls with only cavity insulation are particularly susceptible to air leakage condensation. None of the walls performed well when a precipitation based bulk water leak was introduced to the backside of the sheathing, emphasizing the importance of proper flashing details.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Management of High-R Walls (Fact Sheet)

The following report explains the moisture-related concerns for High R-value wall assemblies and discusses past Building America research work that informs this study. Hygrothermal simulations were prepared for several common approaches to High R-value wall construction in six cities (Houston, Atlanta, Seattle, St. Louis, Chicago, and International Falls) representing a range of climate zones (2, 3, 4C, 4, 5A, and 7, respectively). The simulations are informed by experience gained from past research in this area and validated by field measurement and forensic experience. The modeling program was developed to assess the moisture durability of the wall assemblies based on three primary sources of moisture: construction moisture, air leakage condensation, and bulk water leakage. The peak annual moisture content of the wood based exterior sheathing was used to comparatively analyze the response to the moisture loads for each of the walls in each given city. Walls which experienced sheathing moisture contents between 20% and 28% were identified as risky, whereas those exceeding 28% were identified as very high risk. All of the wall assemblies perform well under idealized conditions. However, only the walls with exterior insulation, or cavity insulation which provides a hygrothermal function similar to exterior insulation, perform adequately when exposed to moisture loads. Walls with only cavity insulation are particularly susceptible to air leakage condensation. None of the walls performed well when a precipitation based bulk water leak was introduced to the backside of the sheathing, emphasizing the importance of proper flashing details.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Downregulation of a UDP-Arabinomutase Gene in Switchgrass (Panicum virgatum L.) Results in Increased Cell Wall Lignin While Reducing Arabinose-Glycans

Switchgrass (Panicum virgatum L.) is a C 4 perennial prairie grass and a dedicated feedstock for lignocellulosic biofuels. Saccharification and biofuel yields are inhibited by the plant cell wall's natural recalcitrance against enzymatic degradation. Plant hemicellulose polysaccharides such as arabinoxylans structurally support and cross-link other cell wall polymers. Grasses predominately have Type II cell walls that are abundant in arabinoxylan, which comprise nearly 25% of aboveground biomass. A primary component of arabinoxylan synthesis is uridine diphosphate (UDP) linked to arabinofuranose (Araf). A family of UDP-arabinopyranose mutase (UAM)/reversible glycosylated polypeptides catalyze the interconversion between UDP-arabinopyranose (UDP-Arap) and UDP-Araf. The expression of a switchgrass arabinoxylan biosynthesis pathway gene, PvUAM1, was decreased via RNAi to investigate its role in cell wall recalcitrance in the feedstock. PvUAM1 encodes a switchgrass homolog of UDP-arabinose mutase, which converts UDP-Arap to UDP-Araf. Southern blot analysis revealed each transgenic line contained between one to at least seven T-DNA insertions, resulting in some cases, a 95% reduction of native PvUAM1 transcript in stem internodes. Transgenic plants had increased pigmentation in vascular tissues at nodes, but were otherwise similar in morphology to the non-transgenic control. Cell wall-associated arabinose was decreased in leaves and stems by over 50%, but there was an increase in cellulose. In addition, there was a commensurate change in arabinose side chain extension. Cell wall lignin composition was altered with a concurrent increase in lignin content and transcript abundance of lignin biosynthetic genes in mature tillers. Enzymatic saccharification efficiency was unchanged in the transgenic plants relative to the control. Plants with attenuated PvUAM1 transcript had increased cellulose and lignin in cell walls. A decrease in cell wall-associated arabinose was expected, which was likely caused by fewer Araf residues in the arabinoxylan. The decrease in arabinoxylan may cause a compensation response to maintain cell wall integrity by increasing cellulose and lignin biosynthesis. In cases in which increased lignin is desired, e.g., feedstocks for carbon fiber production, downregulated UAM1 coupled with altered expression of other arabinoxylan biosynthesis genes might result in even higher production of lignin in biomass.

09 BIOMASS FUELS↗

Effect of boundary layers on solid walls in three-dimensional subsonic wind tunnels

A linear method is developed which accounts for the effects of boundary layers on solid walls in subsonic three-dimensional wind tunnels. The streamwise gradient of the displacement thickness for a solid-wall boundary layer is expressed in terms of the von Karman momentum integral. The growth of the boundary layer due to the wall shearing stress is small compared to the variation caused by the model-induced pressure gradient. The viscous boundary condition can be expressed in terms of the edge velocity gradient and the gradient of the inviscid velocity potential function at the wall. Utilizing this analysis on the solid walls of several three-dimensional wind tunnel configurations shows that the most pronounced wall boundary-layer effect is on solid blockage for completely closed wind tunnels. For solid-wall tunnel configurations, the streamline curvature interference factor is reduced by a significant amount, while the lift interference factor at the model station does not depend on the boundary-layer parameter. For combination wall configurations, the slot effect of the horizontal walls dominates the viscous effect of the solid sidewalls.

Adcock, J. B.↗

Progress in wind tunnel wall interference assessment/correction procedures at the NAE

Wall corrections as a function of wall porosity in the transonic wall interference problem was assessed. Effective porosities primarily for the two dimensional case were established as follows: (1) comparison of experimental data for two geometrically similar models of different chord/height ratio, an overall value of wall porosity could be deduced; (2) theoretical development which allows for unequal porosity for the floor and ceiling and wall boundary pressure measurements, porosities for floor and ceiling could be deduced; (3) a scheme was developed which allowed unequal porosity of floor and ceiling and streamwise varying porosity. The boundary layer development along the perforated floor and ceiling under the influence of the model pressure field, variations in boundary layer thickness underlining the difficulties in deducing meaningful values of wall porosity were determined. Wall boundary pressure measurement, in combination with singularity modelling of the airfoil, was sufficient to yield required information on the wall interference flow without having to establish some value for wall porosity. The singularity modelling of the airfoil initially covered only lift and volume but was extended to include drag and pitching moment, and second order volume term. It is shown by asymptotic transonic small disturbance analysis, that the derived corrections to angle of attack and free stream Mach number are correct to the first order.

Ohman, L. H.↗

Near-wall modelling of compressible turbulent flows

Work was carried out to formulate near-wall models for the equations governing the transport of the temperature-variance and its dissipation rate. With these equations properly modeled, a foundation is laid for their extension together with the heat-flux equations to compressible flows. This extension is carried out in a manner similar to that used to extend the incompressible near-wall Reynolds-stress models to compressible flows. The methodology used to accomplish the extension of the near-wall Reynolds-stress models is examined and the actual extension of the models for the Reynolds-stress equations and the near-wall dissipation-rate equation to compressible flows is given. Then the formulation of the near-wall models for the equations governing the transport of the temperature variance and its dissipation rate is discussed. Finally, a sample calculation of a flat plate compressible turbulent boundary-layer flow with adiabatic wall boundary condition and a free-stream Mach number of 2.5 using a two-equation near-wall closure is presented. The results show that the near-wall two-equation closure formulated for compressible flows is quite valid and the calculated properties are in good agreement with measurements. Furthermore, the near-wall behavior of the turbulence statistics and structure parameters is consistent with that found in incompressible flows.

So, Ronald M. C.↗

The effect of compliant walls on secondary instabilities in boundary layer transition

The effect of compliant walls on the stage of transition where three-dimensional secondary instabilities (SIs) are excited is studied. A theory developed by Herbert (1983) to represent SIs for two-dimensional primary instabilities is extended to allow for oblique waves. The effects of the variations in primary amplitude, spanwise, wavenumber, and Reynolds number on the SIs are examined. As in the rigid-wall case, the subharmonic mode of SI dominates for low-amplitude disturbances over compliant walls. Both isotropic and nonisotropic compliant walls lead to reduced SI growth rates as compared to the rigid-wall results. Calculations show that, for high frequencies, the nonisotropic wall suppresses the amplification of the SIs, while for the isotropic wall SIs grow with an explosive rate similar to the rigid-wall results. For lower frequencies, both types of compliant wall suppress the amplification of SIs.

Joslin, Ronald D.↗

The formation and evolution of domain walls

Domain walls are sheet-like defects produced when the low energy vacuum has isolated degenerate minima. The researchers' computer code follows the evolution of a scalar field, whose dynamics are determined by its Lagrangian density. The topology of the scalar field determines the evolution of the domain walls. This approach treats both wall dynamics and reconnection. The researchers investigated not only potentials that produce single domain walls, but also potentials that produce a network of walls and strings. These networks arise in axion models where the U(1) Peccei-Quinn symmetry is broken into Z sub N discrete symmetries. If N equals 1, the walls are bounded by strings and the network quickly disappears. For N greater than 1, the network of walls and strings behaved qualitatively just as the wall network shown in the figures given here. This both confirms the researchers' pessimistic view that domain walls cannot play an important role in the formation of large scale structure and implies that axion models with multiple minimum can be cosmologically disastrous.

Press, William H.↗

Two-dimensional adaptive-wall tests in the NASA Ames two- by two-foot transonic wind tunnel

The first tests conducted in the adaptive-wall test section of the Ames Research Center's 2- by 2-Foot Transonic Wind Tunnel are described. A procedure was demonstrated for reducing wall interference in transonic flow past a two-dimensional airfoil by actively controlling flow through the slotted walls of the test section. Flow through the walls was controlled by adjusting pressures in compartments of plenums above and below the test section. Wall interference was assessed by measuring (with a laser velocimeter) velocity distributions along a contour surrounding the model, and then checking those measurements for their compatibility with free-air far-field boundary conditions. Plenum pressures for minimum wall interference were determined from empirical influence coefficients. An NACA 0012 airfoil was tested at angles of attack of 0 and 2, and at Mach numbers between 0.70 and 0.85. In all cases the wall-setting procedure greatly reduced wall interference. Wall interference, however, was never completely eliminated, primarily because the effect of plenum pressure changes on the velocities along the contour could not be accurately predicted.

Schairer, Edward T.↗

A wall interference assessment/correction system

A Wall Signature method, the Hackett method, has been selected to be adapted for the 12-ft Wind Tunnel wall interference assessment/correction (WIAC) system in the present phase. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interferences at the model location. The Wall Signature method will be formulated for application to the unique geometry of the 12-ft Tunnel. The development and implementation of a working prototype will be completed, delivered and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method-Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. Each set of wind tunnel/test article numerical simulations provides data to validate the WIAC method. A numerical wind tunnel test simulation is initiated to validate the WIAC methods developed in the project. In the present reported period, the blockage correction has been developed and implemented for a rectangular tunnel as well as the 12-ft Pressure Tunnel. An improved wall interference assessment and correction method for three-dimensional wind tunnel testing is presented in the appendix.

Lo, Ching F.↗

Large-eddy simulations with wall models

The near-wall viscous and buffer regions of wall-bounded flows generally require a large expenditure of computational resources to be resolved adequately, even in large-eddy simulation (LES). Often as much as 50% of the grid points in a computational domain are devoted to these regions. The dense grids that this implies also generally require small time steps for numerical stability and/or accuracy. It is commonly assumed that the inner wall layers are near equilibrium, so that the standard logarithmic law can be applied as the boundary condition for the wall stress well away from the wall, for example, in the logarithmic region, obviating the need to expend large amounts of grid points and computational time in this region. This approach is commonly employed in LES of planetary boundary layers, and it has also been used for some simple engineering flows. In order to calculate accurately a wall-bounded flow with coarse wall resolution, one requires the wall stress as a boundary condition. The goal of this work is to determine the extent to which equilibrium and boundary layer assumptions are valid in the near-wall regions, to develop models for the inner layer based on such assumptions, and to test these modeling ideas in some relatively simple flows with different pressure gradients, such as channel flow and flow over a backward-facing step. Ultimately, models that perform adequately in these situations will be applied to more complex flow configurations, such as an airfoil.

Cabot, W.↗

Analytical Modeling of Pressure Wall Hole Size and Maximum Tip-to-Tip Crack Length for Perforating Normal and Oblique Orbital Debris Impacts

This report presents the results of a study whose objective was to develop first-principles-based models of hole size and maximum tip-to-tip crack length for a spacecraft module pressure wall that has been perforated in an orbital debris particle impact. The hole size and crack length models are developed by sequentially characterizing the phenomena comprising the orbital debris impact event, including the initial impact, the creation and motion of a debris cloud within the dual-wall system, the impact of the debris cloud on the pressure wall, the deformation of the pressure wall due to debris cloud impact loading prior to crack formation, pressure wall crack initiation, propagation, and arrest, and finally pressure wall deformation following crack initiation and growth. The model development has been accomplished through the application of elementary shock physics and thermodynamic theory, as well as the principles of mass, momentum, and energy conservation. The predictions of the model developed herein are compared against the predictions of empirically-based equations for hole diameters and maximum tip-to-tip crack length for three International Space Station wall configurations. The ISS wall systems considered are the baseline U.S. Lab Cylinder, the enhanced U.S. Lab Cylinder, and the U.S. Lab Endcone. The empirical predictor equations were derived from experimentally obtained hole diameters and crack length data. The original model predictions did not compare favorably with the experimental data, especially for cases in which pressure wall petalling did not occur. Several modifications were made to the original model to bring its predictions closer in line with the experimental results. Following the adjustment of several empirical constants, the predictions of the modified analytical model were in much closer agreement with the experimental results.

Schonberg, William P.↗

Use of Ultrasound to Improve the Effectiveness of a Permeable Treatment Wall

A method for increasing the effectiveness of a permeable treatment wall is described. The method includes the introduction of ultrasonic radiation in or near the wall. A permeable treatment wall is also described which has an ultrasonic radiation generating transducer in or near the wall. Permeable treatment walls are described as having either a well vertically extending into the wall, or a rod vertically extending into the treatment wall. Additionally, a method for adapting a permeable treatment wall to allow for the introduction of ultrasonic radiation in or near the wall is described.

Quinn, Jacqueline W.↗