Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Arc Jet Test and Analysis of Asbestos Free Solid Rocket Motor Nozzle Dome Ablative Materials

Asbestos free solid motor internal insulation samples were recently tested at the MSFC Hyperthermal Arc Jet Facility. Objectives of the test were to gather data for solid rocket motor analog characterization of ablative and in-depth thermal performance of rubber materials subject to high enthalpy/pressure flow conditions. Tests were conducted over a range of convective heat fluxes for both inert and chemically reactive sub-sonic free stream gas flow. Active instrumentation included use of total calorimeters, in-depth thermocouples, and a surface pyrometer for in-situ surface temperature measurement. Post-test sample forensics involved determination of eroded depth, charred depth, total sample weight loss, and documentation of the general condition of the eroded profile. A complete Charring Material Ablator (CMA) style aero thermal analysis was conducted for the test matrix and results compared to the measured data. In general, comparisons were possible for a number of the cases and the results show a limited predictive ability to model accurately both the ablative response and the in-depth temperature profiles. Lessons learned and modeling recommendations are made regarding future testing and modeling improvements that will increase understanding of the basic chemistry/physics associated with the complicated material ablation process of rubber materials.

Clayton, J. Louie↗

Thermal Testing of Ablators in the NASA Johnson Space Center Radiant Heat Test Facility

A spacecraft's thermal protection system (TPS) is required to survive the harsh environment experienced during reentry. Accurate thermal modeling of the TPS is required to since uncertainties in the thermal response result in higher design margins and an increase in mass. The Radiant Heat Test Facility (RHTF) located at the NASA Johnson Space Center (JSC) replicates the reentry temperatures and pressures on system level full scale TPS test models for the validation of thermal math models. Reusable TPS, i.e. tile or reinforced carbon-carbon (RCC), have been the primary materials tested in the past. However, current capsule designs for MPCV and commercial programs have required the use of an ablator TPS. The RHTF has successfully completed a pathfinder program on avcoat ablator material to demonstrate the feasibility of ablator testing. The test results and corresponding ablation analysis results are presented in this paper.

Del Papa, Steven↗

Arcjet Ablation of Stony and Iron Meteorites

A test campaign was conducted placing meteorites in the 60 MW plasma Arcjet Interaction Heating Facility at NASA Ames Research Center, with the aim to achieve flight-relevant conditions for asteroid impacts in Earth's atmosphere and to provide insight into how meteoritic materials respond to extreme entry heating environments. The test conditions at heat flux of 4000 W/m2 and 140 kPa stagnation pressure are comparable to those experienced by a 30-meter diameter asteroid moving at 20 km/s velocity at 65 km altitude in the Earth's atmosphere. Test objects were a stony type H5 ordinary chondrite (Tamdakht) and an iron type IAB-MG meteorite (Campo Del Cielo), and included the terrestrial analogs Dense Flood Basalt and Fused Silica. All samples were exposed for only a few seconds in the plasma stream. Significant melt flow and vaporization was observed for both the stony and iron meteorites during exposure. Mass loss from spallation of fragments was also observed. Vapor emitted atomic lines from alkali metals and iron, but did not emit the expected MgO molecular band emissions. The meteoritic melts flowed more rapidly, indicating lower viscosity, than those of Fused Silica. The surface recession was mapped. The effective heat of ablation derived from this showed that ablation under these conditions occurred in the melt-dominated regime. Ablation parameters have an effect on ground damage estimates. A bias in ablation parameters towards the melt-dominated regime would imply that impacting asteroids survive to lower altitude, and therefore could possibly have airbursts with a larger ground damage footprint.

Asteroid↗

Arcjet Ablation of Stony and Iron Meteorites

A test campaign was conducted placing meteorites in the 60 MW plasma Arcjet Interaction Heating Facility at NASA Ames Research Center, with the aim to achieve flight-relevant conditions for asteroid impacts in Earth's atmosphere and to provide insight into how meteoritic materials respond to extreme entry heating environments. The test conditions at heat flux of 4000 W/m2 and 140 kPa stagnation pressure are comparable to those experienced by a 30-meter diameter asteroid moving at 20 km/s velocity at 65 km altitude in the Earth's atmosphere. Test objects were a stony type H5 ordinary chondrite (Tamdakht) and an iron type IAB-MG meteorite (Campo Del Cielo), and included the terrestrial analogs Dense Flood Basalt and Fused Silica. All samples were exposed for only a few seconds in the plasma stream. Significant melt flow and vaporization was observed for both the stony and iron meteorites during exposure. Mass loss from spallation of fragments was also observed. Vapor emitted atomic lines from alkali metals and iron, but did not emit the expected MgO molecular band emissions. The meteoritic melts flowed more rapidly, indicating lower viscosity, than those of Fused Silica. The surface recession was mapped. The effective heat of ablation derived from this showed that ablation under these conditions occurred in the melt-dominated regime. Ablation parameters have an effect on ground damage estimates. A bias in ablation parameters towards the melt-dominated regime would imply that impacting asteroids survive to lower altitude, and therefore could possibly have airbursts with a larger ground damage footprint.

Arcjet↗

Characterization of a Radiometer Window for Mars Aftbody Heating Including Ablation Product Deposition Using a Miniature Arc Jet

The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 mission includes a radiometer on the backshell to measure the radiative heating during entry into the Martian atmosphere. Thermal Protection System (TPS) ablation products may be deposited on the radiometer window which would degrade the transmission and thus alter the accuracy of the radiometer readings. Testing in NASA Ames Research Center's miniature arc jet (mARC) facility was conducted to deposit TPS ablation products on radiometer windows in an effort to characterize how the ablation products change the window transmission and thus alter radiometer performance. Heat flux and stagnation pressure characterization of the mARC facility in a 90 percent CO2, 10 percent N2 (by mass) Mars-like environment are presented. The spectral transmission of the radiometer windows before and after mARC testing are compared. Additionally, a discussion of how flight-like these test conditions were and future work to further characterize the effect of TPS ablation on radiometer performance are presented.

Miller, Ruth A.↗

Impulse Measurements of Electric Solid Propellant in an Electrothermal Ablation-Fed Pulsed Plasma Thruster

Electric solid propellants are advanced solid chemical rocket propellants that can be controlled (ignited, throttled and extinguished) through the application and removal of an electric current. These propellants are also being considered for use in the ablative pulsed plasma thruster. In this paper, the performance of an electric solid propellant operating in an electrothermal ablation-fed pulsed plasma thruster was investigated using an inverted pendulum micro-Newton thrust stand. The impulse bit and specific impulse of the device using the electric solid propellant were measured for short-duration test runs of 100 pulses and longer-duration runs to end-of-life, at energy levels of 5, 10, 15 and 20 J. Also, the device was operated using the current state-of-the-art ablation-fed pulsed plasma thruster propellant, polytetrafluoroethylene or PTFE. Impulse bit measurements for PTFE indicate 100±20 μN-s at an initial energy level of 5 J, which increases linearly by ~30 μN-s/J with increased initial energy. Measurements of the impulse bit for the electric solid propellant are on average lower than PTFE by 10% or less. Specific impulse for when operating on PTFE is calculated to be about 450 s compared to 225 s for the electric solid propellant. The 50% reduction in specific impulse is due to increased mass ablated during operation with the electric solid propellant relative to PTFE.

Glascock, Matthew S.↗

Modeling Snow Ablation over the Western United States Mountains: Patterns and Controlling Factors

When compared with differences in snow accumulation predicted by widely used hydrological models, there is a much greater divergence among otherwise “good” models in their simulation of the snow ablation process. Here, we explore differences in the performance of the Variable Infiltration Capacity model (VIC), Noah land surface model with multiparameterization options (Noah-MP), the Catchment model, and the third-generation Simplified Simple Biosphere model (SiB3) in their ability to reproduce observed snow water equivalent (SWE) during the ablation season at 10 Snowpack Telemetry (SNOTEL) stations over 1992–2012. During the ablation period, net radiation generally has stronger correlations with observed melt rates than does air temperature. Average ablation rates tend to be higher (in both model predictions and observations) at stations with a large accumulation of SWE. The differences in the dates of last snow between models and observations range from several days to approximately a month (on average 5.1 days earlier than in observations). If the surface cover in the models is changed from observed vegetation to bare soil in all of the models, only the melt rate of the VIC model increases. The differences in responses of models to canopy removal are directly related to snowpack energy inputs, which are further affected by different algorithms for surface albedo and energy allocation across the models. We also find that the melt rates become higher in VIC and lower in Noah-MP if the shrub/grass present at the observation sites is switched to trees.

Snow↗

An Approach to Critical Ablative TPS Capabilities Sustainment for Future NASA Missions

We plan to present an approach for NASA to maintain critical ablative TPS capabilities through small, sus-tained, smart and targeted investment. Historically, we have been pound foolish and penny wise for decades and paid very little attention to sustainability of abla-tive TPS and as a result, spent couple of decades in learning what we lost and inventing newer technology solutions. NASA’s ablative TPS history has been one of in-vesting in new and unique capabilities in anticipation of needs, and once flight proven, letting the capability atrophy due to lack of subsequent near-term mission needs [1]. When the need arises, NASA has resorted to two options: (1) revive the capability at considerable cost impact, or (2) develop an alternate capability with considerable schedule impact. Both these options have had considerable mission impact. The third alternate is to maintain proven capabilities in a cost effective manner. A risk informed decision process in terms of maintaining ablative TPS capabilities is feasible with planning and sustained support. Assured TPS availa-bility will allow the science community to propose competed missions with confidence and at a lower risk for selection. We submitted a white paper to the cur-rent Decadal Survey [2] on the need for and im-portance of sustainability. Since then, we have been formulating an executable cost effective strategy. The intent of this presentation is to outline the develop-ments since the submission of the white paper. NASA and DoD have had a working group related to critical technologies to periodically assess and make recommendations on at-risk items from a national need perspective. This inter-agency working group typically focuses on raw materials availability. While we agree that at-risk raw materials are important, fo-cus solely on them is not sufficient. Instead, we advo-cate for a broader focus that includes not only raw material but also industrial manufacturing and processing, and NASA expertise in design, testing and flight hardware certification. In this proposed presentation, we will give a brief overview of NASA’s ablative TPS history along with recent examples of atrophy to highlight case studies related to the PICA and Carbon-Phenolic TPS. We will present the rationale for sustaining PICA, HEEET and 3MDCP for future NASA missions. We will present an approach for how targeted small investments could lead to maintaining mission critical capabilities over long periods.

E Venkatapathy↗

Subcellular analysis by laser ablation electrospray ionization mass spectrometry

In various embodiments, a method of laser ablation electrospray ionization mass spectrometry (LAESI-MS) may generally comprise micro-dissecting a cell comprising at least one of a cell wall and a cell membrane to expose at least one subcellular component therein, ablating the at least one subcellular component by an infrared laser pulse to form an ablation plume, intercepting the ablation plume by an electrospray plume to form ions, and detecting the ions by mass spectrometry.

47 OTHER INSTRUMENTATION↗

Microglial ablation and lipopolysaccharide preconditioning affects pilocarpine-induced seizures in mice

Activated microglia have been associated with neurodegeneration in patients and in animal models of Temporal Lobe Epilepsy (TLE), however their precise functions as neurotoxic or neuroprotective is a topic of significant investigation. To explore this, we examined the effects of pilocarpine-induced seizures in transgenic mice where microglia/macrophages were conditionally ablated. We found that unilateral ablation of microglia from the dorsal hippocampus did not alter acute seizure sensitivity. However, when this procedure was coupled with lipopolysaccharide (LPS) preconditioning (1 mg/kg given 24 h prior to acute seizure), we observed a significant pro-convulsant phenomenon. This effect was associated with lower metabolic activation in the ipsilateral hippocampus during acute seizures, and could be attributed to activity in the mossy fiber pathway. These findings reveal that preconditioning with LPS 24 h prior to seizure induction may have a protective effect which is abolished by unilateral hippocampal microglia/macrophage ablation.

59 BASIC BIOLOGICAL SCIENCES↗

Isotope Ratio Analysis on Micron-Sized Particles in Complex Matrices by Laser Ablation – Absorption Ratio Spectrometry

Laser ablation has been combined with dual tunable diode laser absorption spectrometry to measure 152 Gd: 160 Gd isotope ratios in micron-size particles. The diode lasers are tuned to specific isotopes in two different atomic transitions at 405.9 nm ( 152 Gd) and 413.4 nm ( 160 Gd) and directed collinearly through the laser ablation plume, separated on a diffraction grating, and detected with photodiodes to monitor transient absorption signals on a shot-by-shot basis. The method has been characterized first using Gd metal foil and then with particles of GdCl 3 •xH 2 0 as binary and ternary mixtures with 152Gd:160Gd isotope ratios ranging from 0.01 to 0.43. These particulate mixtures have been diluted with Columbia River sediment powder (SRM 4350B) to simulate environmental samples and we show the method is capable of detecting a few highly enriched particles in the presence of > 100-fold excess of low-enrichment particles, even when the Gd-bearing particles are a minor component (0.08%) in the SRM powder and widely dispersed (1178 particles detected in 800 000 ablation laser shots). The implications for monitoring 235 U: 238 U enrichment ratios, as related to the nuclear industry, are discussed

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Femtosecond laser ablation particle introduction to a liquid sampling-atmospheric pressure glow discharge ionization source

This work describes the use of a compact, liquid sampling – atmospheric pressure glow discharge (LS-APGD) ionization source to ionize metal particles within a laser ablation aerosol. Mass analysis was performed with a Thermo Scientific Exactive Mass Spectrometer which utilizes an orbitrap mass analyzer capable of producing mass resolution exceeding M/ΔM > 160,000. The LS-APGD source generates a low-power plasma between the surface of an electrolytic solution flowing at several µl min-1 through a fused silica capillary and a counter electrode consisting of a stainless steel capillary employed to deliver the laser ablation particles into the plasma. Sample particles of approximately 100 nm were generated with an Applied Spectra femtosecond laser located remotely and transported through 25 meters of polyurethane tubing by means of argon carrier gas. Samples consisted of an oxygen free copper shard, a disk of solder, and a one-cent U.S. coin. Analyte signal onset was readily detectable relative to the background signal produced by the carrier gas alone. The high mass resolution capability of the orbitrap mass spectrometer was demonstrated on the solder sample with resolution exceeding 90,000 for Pb and 160,000 for Cu. In addition, results from a laser ablation depth-profiling experiment of a one cent coin revealed retention of the relative locations of the ~10 µm copper cladding and zinc rich bulk layers.

36 MATERIALS SCIENCE↗

Atomic understanding of structural deformations upon ablation of graphene

We investigate the atomic rearrangement in graphene under femtosecond pulse illumination with reactive molecular dynamics simulations and compare with ultra-fast laser ablation experiments. To model the impact of the laser pulse irradiation, heat is locally applied to a selected area of the graphene layer and the resulting structural deformation is simulated as a function of time, providing a detailed understanding of the bond breaking process under laser illumination and subsequent re-equilibration afterAQ3 the pulse is turned off. Analysis of the atomic dynamics indicates that the types of defects formed depend on the pulse energy and exposure duration. By varying the exposed area, we determine that the shape of the ablated area is not only a function of the pulse energy, but also of the beam spot size and pulse repetition. Furthermore, we apply a machine learning approach to extrapolate our simulated data to experimental length scales and reproduce the trends in ablated area as a function of temperature. Furthermore, our study provides a first step towards understanding the design parameters for graphene nano-patterning.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Combining Transmission Geometry Laser Ablation and a Non Contact Continuous Flow Surface Sampling Probe/Electrospray Emitter for Mass Spectrometry-Based Chemical Imaging

This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection into a continuous flow surface sampling probe/electrospray emitter for mass spectrometry based chemical imaging. The flow probe/emitter device was placed in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collected was immediately aspirated into the probe and on to the electrospray emitter, ionized and detected with the mass spectrometer. Freehand drawn ink lines and letters and an inked fingerprint on microscope slides were analyzed. The circular laser ablation area was about 210 m in diameter and under the conditions used in these experiments the spatial resolution, as determined by the size of the surface features distinguished in the chemical images, was about 100 m.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of Pleural Temperature During Radiofrequency Ablation of Lung Tumors to Investigate Its Relationship to Occurrence of Pneumothorax or Pleural Effusion

The purpose of this study was to investigate the relationship between pleural temperature and pneumothorax or pleural effusion after radiofrequency (RF) ablation of lung tumors. The pleural temperature was measured immediately outside the lung surface nearest to the tumor with a fiber-type thermocouple during 25 ablation procedures for 34 tumors in 22 patients. The procedures were divided into two groups depending on the highest pleural temperature: P-group I and P-group II, with highest pleural temperatures of <40 deg. C and {>=}40 deg. C, respectively. The incidence of pneumothorax or pleural effusion was compared between the groups. Multiple variables were compared between the groups to determine the factors that affect the pleural temperature. The overall incidence of pneumothorax and pleural effusion was 56% (14/25) and 20% (5/25), respectively. Temperature data in five ablation procedures were excluded from the analyses because these were affected by the pneumothorax. P-group I and P-group II comprised 10 procedures and 10 procedures, respectively. The incidence of pleural effusion was significantly higher in P-group II (4/10) than in P-group I (0/10) (p = 0.043). However, the incidence of pneumothorax did not differ significantly (p = 0.50) between P-group I (4/10) and P-group II (5/10). Factors significantly affecting the pleural temperature were distance between the electrode and the pleura (p < 0.001) and length of the lung parenchyma between the electrode and the pleura (p < 0.001). We conclude that higher pleural temperature appeared to be associated with the occurrence of pleural effusion and not with that of pneumothorax.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Radiofrequency Ablation of Painful Spinal Tumors Adjacent to the Spinal Cord with Real-Time Monitoring of Spinal Canal Temperature: A Prospective Study

PurposeTo prospectively evaluate the feasibility, safety, and clinical utility of bone radiofrequency (RF) ablation with real-time monitoring of the spinal canal temperature for the treatment of spinal tumors adjacent to the spinal cord.Materials and MethodsOur Institutional Review Board approved this study. Patients gave informed consent. The inclusion criteria were (a) a painful spinal metastasis and (b) a distance of 1 cm or less between the metastasis and the spinal cord. The thermocouple was placed in the spinal canal under CT fluoroscopic guidance. When the spinal canal temperature reached 45{sup o}C, RF application was immediately stopped. RF ablation was considered technically successful when the procedure was performed without major complications. Clinical success was defined as a fall in the visual analogue scale score of at least 2 points.ResultsTen patients with spinal tumors measuring 3-8 cm (mean, 4.9 {+-} 1.5 cm) were enrolled. The distance between the tumor and the spinal cord was 1-6 mm (mean, 2.4 {+-} 1.6 mm). All procedures were judged technically successful (100%). The spinal canal temperature did not exceed 45{sup o}C in 9 of the 10 patients (90%). In the remaining patient, the temperature rose to 48{sup o}C, resulting in transient neural damage, although RF application was immediately stopped when the temperature reached 45{sup o}C. Clinical success was achieved within 1 week in all patients (100%).ConclusionBone RF ablation with real-time monitoring of the spinal canal temperature is feasible, safe, and clinically useful for the treatment of painful spinal metastases adjacent to the spinal cord.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous RF Thermal Ablation of Renal Tumors: Is US Guidance Really Less Favorable Than Other Imaging Guidance Techniques?

The purpose of this study was to compare our experience with ultrasound (US)-guided percutaneous radiofrequency thermal ablation (RFA) of renal tumors with results of CT-guided and MRI-guided series in the current literature. Of 90 consecutive renal tumors treated with RFA in 71 patients, 87 lesions were ablated under US guidance. We performed a retrospective analysis of clinical outcome and safety. Results were then compared to published case series where CT and MRI guidances were used exclusively. In our series we had a major complication rate of 4.6%, whereas in CT- and MRI-based series it was 0-12% (mean, 2.2%) and 0-8.3% (mean, 4.1%), respectively. During follow-up (1-68 months; mean, 24 months) technical effectiveness was 89.7%, while it was between 89.5% and 96% in CT-guided series and between 91.7% and 100% in MRI-guided series. The size of successfully treated lesions (28 mm) was lower than that of partially-ablated lesions (36 mm; p = 0.004) and only central lesion location proved to be a negative prognostic factor (p = 0.009); in CT-guided series, positive prognostic factors were exophytic growth and size {<=}3 cm. 'Tumor-specific' 2-year survival was 92% in our series, 90-96% in CT-guided series, and not reported in MRI-guided series. In conclusion, despite common beliefs, US guidance in RFA of renal tumors is not less favorable than other guidance techniques. Thus the interventional radiologist can choose his or her preferred technique taking into account personal experience and available equipment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation Assisted by Real-Time Virtual Sonography and CT for Hepatocellular Carcinoma Undetectable by Conventional Sonography

Real-time virtual sonography (RVS) is a diagnostic imaging support system, which provides the same cross-sectional multiplanar reconstruction images as ultrasound images on the same monitor screen in real time. The purpose of this study was to evaluate radiofrequency ablation (RFA) assisted by RVS and CT for hepatocellular carcinoma (HCC) undetectable with conventional sonography. Subjects were 20 patients with 20 HCC nodules not detected by conventional sonography but detectable by CT or MRI. All patients had hepatitis C-induced liver cirrhosis; there were 13 males and 7 females aged 55-81 years (mean, 69.3 years). RFA was performed in the CT room, and the tumor was punctured with the assistance of RVS. CT was performed immediately after puncture, and ablation was performed after confirming that the needle had been inserted into the tumor precisely. The mean number of punctures and success rates of the first puncture were evaluated. Treatment effects were evaluated with dynamic CT every 3 months after RFA. RFA was technically feasible and local tumor control was achieved in all patients. The mean number of punctures was 1.1, and the success rate of the first puncture was 90.0%. This method enabled safe ablation without complications. The mean follow-up period was 13.5 month (range, 9-18 months). No local recurrence was observed at the follow-up points. In conclusion, RFA assisted by RVS and CT is a safe and efficacious method of treatment for HCC undetectable by conventional sonography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗